954 resultados para Computer software - Quality control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caraterização e Análise Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caracterização e Análise Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research described in this thesis has been developed as a part of the Reliability and Field Data Management for Multi-component Products (REFIDAM) Project. This project was founded under the Applied Research Grants Scheme administered by Enterprise Ireland. The project was a partnership between Galway-Mayo Institute of Technology and Thermo King Europe. The project aimed to develop a system in order to manage the information required for reliability assessment and improvement of multi-component products, by establishing information flows within the company and information exchange with fleet users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Text classification, information filtering, semi-supervised learning, quality control

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de mestrado em Biologia Humana e Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this contract was to finalise in vitro rearing on artificial diets of entomophagous insects useful to control insect pests mainly in greenhouses through an analytical and rational approach. The work focuses on the development and optimisation of artificial diets for one coccinellid (Harmonia axyridis), two heteropteran predators (Orius laevigatus, Dicyphus tamaninii), and a braconid parasitoid of aphids (Aphidius ervi). The definition of the artificial diets was based on biochemical analyses of their natural food (aphids) or substitution food for the predators (Ephestia kuehniella eggs). Reliable quality control parameters of the entomophages produced were used in order to adjust dietary composition and formulation of the different diets tested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este proyecto surge de una necesidad industrial por parte de una empresa dedicada al procesado y envasado de pescado fresco y congelado (Elaborados Freiremar S.A). Para satisfacer esta necesidad, se decidió colocar una línea de proceso totalmente automatizada. Dicha automatización, consta de 3 partes totalmente diferenciales pero relacionadas entre ellas, puesto que sin alguna de estas partes la línea no podría funcionar correctamente. El software de control (PLC) se encarga de controlar y actuar sobre la máquina con los diferentes sensores, células de carga, motores… La SCADA en Visual Basic (Pantalla táctil)se encarga de mantener una comunicación continua con el software de control, y va almacenando todos los datos referentes a la línea y sus rendimientos. El software de consultas se instala en un PC de oficinas y se utiliza para sacar informes con todos los datos obtenidos del SCADA en Visual Basic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assays that measure a patient's immune response play an increasingly important role in the development of immunotherapies. The inherent complexity of these assays and independent protocol development between laboratories result in high data variability and poor reproducibility. Quality control through harmonization--based on integration of laboratory-specific protocols with standard operating procedures and assay performance benchmarks--is one way to overcome these limitations. Harmonization guidelines can be widely implemented to address assay performance variables. This process enables objective interpretation and comparison of data across clinical trial sites and also facilitates the identification of relevant immune biomarkers, guiding the development of new therapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: As part of the MicroArray Quality Control (MAQC)-II project, this analysis examines how the choice of univariate feature-selection methods and classification algorithms may influence the performance of genomic predictors under varying degrees of prediction difficulty represented by three clinically relevant endpoints. Methods: We used gene-expression data from 230 breast cancers (grouped into training and independent validation sets), and we examined 40 predictors (five univariate feature-selection methods combined with eight different classifiers) for each of the three endpoints. Their classification performance was estimated on the training set by using two different resampling methods and compared with the accuracy observed in the independent validation set. Results: A ranking of the three classification problems was obtained, and the performance of 120 models was estimated and assessed on an independent validation set. The bootstrapping estimates were closer to the validation performance than were the cross-validation estimates. The required sample size for each endpoint was estimated, and both gene-level and pathway-level analyses were performed on the obtained models. Conclusions: We showed that genomic predictor accuracy is determined largely by an interplay between sample size and classification difficulty. Variations on univariate feature-selection methods and choice of classification algorithm have only a modest impact on predictor performance, and several statistically equally good predictors can be developed for any given classification problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and aims: Family-centred care is an expected standard in PICU and parent reported outcomes are rarely measured. The Dutch validated EMPATHIC questionnaire provides accurate measures of parental perceptions of family-centred care in PICU. A French version would provide an important resource for quality control and benchmarking with other PICUs. The study aimed to translate and to assess the French cultural adaptation of the EMPATHIC questionnaire. Methods: In September 2012, following approval from the developer, translation and cultural adaptation were performed using a structured method (Wild et al. 2005). This included forward-backward translation and reconciliation by an official translator, harmonization assessed by the research team, and cognitive debriefing with the target users' population. In this last step, a convenience sample of parents with PICU experience assessed the comprehensibility and cultural relevance of the 65-item French EMPATHIC questionnaire. The PICUs in Lausanne, Switzerland and Lille, France participated. Results: Seventeen parents, including 13 French native and 4 French as second language speakers, tested the cognitive equivalence and cultural relevance of the French EMPATHIC questionnaire. The mean agreement for comprehensibility of all 65 items reached 90.2%. Three items fell below the cut-off 80% agreement and were revised for inclusion in the final French version. Conclusions: The translation and the cultural adaptation permitted to highlight a few cultural differences that did not interfere with the main construct of the EMPATHIC questionnaire. Reliability and validity testing with a new sample of parents is needed to strengthen the psychometric properties of the French EMPATHIC questionnaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Artificial antigen-presenting cells (aAPC) are widely used for both clinical and basic research applications, as cell-based or bead-based scaffolds, combining immune synapse components of interest. Adequate and controlled preparation of aAPCs is crucial for subsequent immunoassays. We reveal that certain proteins such as activatory anti-CD3 antibody can be out-competed by other proteins (e.g. inhibitory receptor ligands such as PDL1:Fc) during the coating of aAPC beads, under the usually performed coating procedures. This may be misleading, as we found that decreased CD8 T cell activity was not due to inhibitory receptor triggering but rather because of unexpectedly low anti-CD3 antibody density on the beads upon co-incubation with inhibitory receptor ligands. We propose an optimized protocol, and emphasize the need to quality-control the coating of proteins on aAPC beads prior to their use in immunoassays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The International Molecular Exchange (IMEx) consortium is an international collaboration between major public interaction data providers to share literature-curation efforts and make a nonredundant set of protein interactions available in a single search interface on a common website (http://www.imexconsortium.org/). Common curation rules have been developed, and a central registry is used to manage the selection of articles to enter into the dataset. We discuss the advantages of such a service to the user, our quality-control measures and our data-distribution practices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Athlete Biological Passport (ABP) is an individual electronic document that collects data regarding a specific athlete that is useful in differentiating between natural physiologic variations of selected biomarkers and deviations caused by artificial manipulations. A subsidiary of the endocrine module of the ABP, that which here is called Athlete Steroidal Passport (ASP), collects data on markers of an altered metabolism of endogenous steroidal hormones measured in urine samples. The ASP aims to identify not only doping with anabolic-androgenic steroids, but also most indirect steroid doping strategies such as doping with estrogen receptor antagonists and aromatase inhibitors. Development of specific markers of steroid doping, use of the athlete's previous measurements to define individual limits, with the athlete becoming his or her own reference, the inclusion of heterogeneous factors such as the UDPglucuronosyltransferase B17 genotype of the athlete, the knowledge of potentially confounding effects such as heavy alcohol consumption, the development of an external quality control system to control analytical uncertainty, and finally the use of Bayesian inferential methods to evaluate the value of indirect evidence have made the ASP a valuable alternative to deter steroid doping in elite sports. The ASP can be used to target athletes for gas chromatography/combustion/ isotope ratio mass spectrometry (GC/C/IRMS) testing, to withdraw temporarily the athlete from competing when an abnormality has been detected, and ultimately to lead to an antidoping infraction if that abnormality cannot be explained by a medical condition. Although the ASP has been developed primarily to ensure fairness in elite sports, its application in endocrinology for clinical purposes is straightforward in an evidence-based medicine paradigm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From March 1990 to December 1992, the National Institute for Quality Control of Health-INCQS Research Collection received 1476 bacterial samples isolated from human cerebrospinal fluid of patients suspect of meningitis in Rio de Janeiro, from the São Sebastião State Institute of Infectious Diseases (IEISS). Neisseria meningitidis was found in most of these materials, followed in smaller number by Haemophilus sp. and Streptococcus pneumoniae. The great majority of N. meningitidis strains was serogroup B, followed by serogroup C and a few strains of serogroup W135. More than 50 of the isolated bacterial agents came from the predominant 0-4 years age group. The majority of the strains were from patients in the region known as "Baixada Fluminense" (Low Lands). The aim of the work presented here is to obtain samples of meningitis cases in at least 70 of the State of Rio de Janeiro and develop a collaborative research between INCQS-FIOCRUZ and the IEISS, in order to set up a collection of strains for future studies. However, despite work being carried out in a rather satisfactory way, difficulties still arise and have to be overcome, to survey data.