985 resultados para Compact- range measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

v.20:no.13(1936)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

v.7:no.6(1943)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total urinary neutral 17-steroids were determined in normal and in castrated horses. One liter of a 15-26 hours urine collection was hydrolysed by refluxing with 10% HC1 (v/v) for ten minutes and extracted with peroxyde-free ethyl ether. The extract was purified by washing with saturated NaHCO³ and KOH solutions. One half of the crude neutral fraction was fractionated with Girard's "T" reagent . The Zimmermann reaction was performed both in the ketonic and in the crude neutral extracts, using alcoholic 2.5N KOH and a 60 minutes period for the colour development in the dark. Optical density measuments were made in a grating Coleman Universal Spectrophotometer at 420 mµ and 520mµ; for the crude neutral fraction a colour correction equation was applied. The aliquot fraction used for colorimety was adjusted for keeping optical density measurements within the range 0.2 to 0.7. Androsterone (mp. 184-184.5°C) with an absorption maximum at 290.5 mµ (Beckman Model DU Spectrophotometer) was used as a reference standard. Table I, ilustrates the results obtained. At the 0.05 probability level there is a significant difference among castrated and normal group means (Fischer's "t" test.) when were used the data obtained from the ketonic fractions; in spite of the use of a colour correction applied for inespecific chromogens, the same results could not be obtained with the crude neutral fractions, Since Girard's reagent fractionation is generaly accepted as the best method for correcting the inespecific chromogen interference in the determination of the 17-ketosteroids by the Zimmermann reaction, we emphasize the value of the results obtained with the ketonic fractions. From these results it appears, as occurs in others mammals, that castrated horses show a lower level of urinary 17-ketosteroids excretion than the normal horses. The significance of the horse testis contribution for the neutral urinary steroid metabolites is discussed. Since horse urine has a low androgenic activity, the fractionation of the neutral 17-ketosteroids must be studied more accurately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study of noncompact Euclidean cone manifolds with cone angles less than c&2π and singular locus a submanifold. More precisely, we describe its structure outside a compact set. As a corol lary we classify those with cone angles & 2π/3 and those with cone angles = 2π/3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada a l’ Imperial College London, entre juliol i novembre de 2006. En aquest treball s’ha investigat la geometria més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. L’objectiu és assegurar la propagació de l’esquerda sense que la proveta falli abans per cap altre mecanisme de dany per tal de permetre la caracterització experimental de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. Amb aquesta fi, s’ha dut a terme l’anàlisi paramètrica de diferents tipus de provetes mitjançant el mètode dels elements finits (FE) combinat amb la virtual crack closure technique (VCCT). Les geometries de les provetes analitzades corresponen a la proveta de l’assaig compact tension (CT) i diferents variacions com la extended compact tension (ECT), la proveta widened compact tension (WCT), tapered compact tension (TCT) i doubly-tapered compact tension (2TCT). Com a resultat d’aquestes anàlisis s’han derivat diferents conclusions per obtenir la geometria de proveta més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. A més, també s’han dut a terme una sèrie d’assaigs experimentals per tal de validar els resultats de les anàlisis paramètriques. La concordança trobada entre els resultats numèrics i experimentals és bona tot i la presència d’efectes no previstos durant els assaigs experimentals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sample of about 70 young bulls of each of ten beef cattle breeds reared in their typical production systems has been characterised with respect to meat quality traits. Breeds included were Asturiana de los Valles, Asturiana de la Montaña, Avileña-Negra Ibérica, Bruna dels Pirineus, Morucha, Pirenaica and Retinta from Spain, and Aubrac, Gasconne and Salers from France. As was previously showed regarding carcass traits, there exist large differences both between and within breed – systems. In general, rustic breeds tended to present darker and redder meats with higher haematin contents, whereas less precocious and more specialised breeds showed brighter meats with bigger water losses. Protein content was similar, whereas intramuscular fat presented the larger variations both between and within breeds. ICDH content was higher in the more rustic breeds, showing the predominantly oxidative character of their fibres. Texture measurements showed in general large within breed-system variations, the differences between breeds being less evident. Within breed-system, daily gain weight was positively associated with brighter and tender meats. In the range studied, increasing slaughter weight within breed did not have influence on meat quality. Conformation was related to lower water holding capacity and less dry matter and intramuscular fat, as well as to a lower haematin content giving brighter meats. The increase in fatness scores was related to an augment of toughness in meat specialised breeds, although in Avileña-Negra Ibérica breed fatness carcasses were related to more tender meats. Redness parameter a* was positively related to fatter animals and opposed to conformation, the opposite being true for the L* (lightness) parameter. There was a small trend of fatter carcasses to be related to oxidative fibres, whereas the muscular fibres of the more conformed carcasses were more glycolytic. Texture measurements maximum load, maximum stress and toughness were very closely related. Shear force was opposed to tenderness. Losses at cooking were opposed to juiciness, but only in the Spanish breeds. No consistent trends regarding relationships between carcass characteristics and tenderness could be observed. Overall acceptability was primarily related with tenderness and flavour, and later on juiciness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accurate estimation of total daily energy expenditure (TEE) in chronic kidney patients is essential to allow the provision of nutritional requirements; however, it remains a challenge to collect actual physical activity and resting energy expenditure in maintenance dialysis patients. The direct measurement of TEE by direct calorimetry or doubly labeled water cannot be used easily so that, in clinical practice, TEE is usually estimated from resting energy expenditure and physical activity. Prediction equations may also be used to estimate resting energy expenditure; however, their use has been poorly documented in dialysis patients. Recently, a new system called SenseWear Armband (BodyMedia, Pittsburgh, PA) was developed to assess TEE, but so far no data have been published in chronic kidney disease patients. The aim of this review is to describe new measurements of energy expenditure and physical activity in chronic kidney disease patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For many drugs, finding the balance between efficacy and toxicity requires monitoring their concentrations in the patient's blood. Quantifying drug levels at the bedside or at home would have advantages in terms of therapeutic outcome and convenience, but current techniques require the setting of a diagnostic laboratory. We have developed semisynthetic bioluminescent sensors that permit precise measurements of drug concentrations in patient samples by spotting minimal volumes on paper and recording the signal using a simple point-and-shoot camera. Our sensors have a modular design consisting of a protein-based and a synthetic part and can be engineered to selectively recognize a wide range of drugs, including immunosuppressants, antiepileptics, anticancer agents and antiarrhythmics. This low-cost point-of-care method could make therapies safer, increase the convenience of doctors and patients and make therapeutic drug monitoring available in regions with poor infrastructure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Hip fractures are responsible for excessive mortality, decreasing the 5-year survival rate by about 20%. From an economic perspective, they represent a major source of expense, with direct costs in hospitalization, rehabilitation, and institutionalization. The incidence rate sharply increases after the age of 70, but it can be reduced in women aged 70-80 years by therapeutic interventions. Recent analyses suggest that the most efficient strategy is to implement such interventions in women at the age of 70 years. As several guidelines recommend bone mineral density (BMD) screening of postmenopausal women with clinical risk factors, our objective was to assess the cost-effectiveness of two screening strategies applied to elderly women aged 70 years and older. METHODS: A cost-effectiveness analysis was performed using decision-tree analysis and a Markov model. Two alternative strategies, one measuring BMD of all women, and one measuring BMD only of those having at least one risk factor, were compared with the reference strategy "no screening". Cost-effectiveness ratios were measured as cost per year gained without hip fracture. Most probabilities were based on data observed in EPIDOS, SEMOF and OFELY cohorts. RESULTS: In this model, which is mostly based on observed data, the strategy "screen all" was more cost effective than "screen women at risk." For one woman screened at the age of 70 and followed for 10 years, the incremental (additional) cost-effectiveness ratio of these two strategies compared with the reference was 4,235 euros and 8,290 euros, respectively. CONCLUSION: The results of this model, under the assumptions described in the paper, suggest that in women aged 70-80 years, screening all women with dual-energy X-ray absorptiometry (DXA) would be more effective than no screening or screening only women with at least one risk factor. Cost-effectiveness studies based on decision-analysis trees maybe useful tools for helping decision makers, and further models based on different assumptions should be performed to improve the level of evidence on cost-effectiveness ratios of the usual screening strategies for osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mont Collon mafic complex is one of the best preserved examples of the Early Permian magmatism in the Central Alps, related to the intra-continental collapse of the Variscan belt. It mostly consists (> 95 vol.%) of ol+hy-nonnative plagioclase-wehrlites, olivine- and cpx-gabbros with cumulitic structures, crosscut by acid dikes. Pegmatitic gabbros, troctolites and anorthosites outcrop locally. A well-preserved cumulative, sequence is exposed in the Dents de Bertol area (center of intrusion). PT-calculations indicate that this layered magma chamber emplaced at mid-crustal levels at about 0.5 GPa and 1100 degrees C. The Mont Collon cumulitic rocks record little magmatic differentiation, as illustrated by the restricted range of clinopyroxene mg-number (Mg#(cpx)=83-89). Whole-rock incompatible trace-element contents (e.g. Nb, Zr, Ba) vary largely and without correlation with major-element composition. These features are characteristic of an in-situ crystallization process with variable amounts of interstitial liquid L trapped between the cumulus mineral phases. LA-ICPMS measurements show that trace-element distribution in the latter is homogeneous, pointing to subsolidus re-equilibration between crystals and interstitial melts. A quantitative modeling based on Langmuir's in-situ crystallization equation successfully duplicated the REE concentrations in cumulitic minerals of all rock facies of the intrusion. The calculated amounts of interstitial liquid L vary between 0 and 35% for degrees of differentiation F of 0 to 20%, relative to the least evolved facies of the intrusion. L values are well correlated with the modal proportions of interstitial amphibole and whole-rock incompatible trace-element concentrations (e.g. Zr, Nb) of the tested samples. However, the in-situ crystallization model reaches its limitations with rock containing high modal content of REE-bearing minerals (i.e. zircon), such as pegmatitic gabbros. Dikes of anorthositic composition, locally crosscutting the layered lithologies, evidence that the Mont Collon rocks evolved in open system with mixing of intercumulus liquids of different origins and possibly contrasting compositions. The proposed model is not able to resolve these complex open systems, but migrating liquids could be partly responsible for the observed dispersion of points in some correlation diagrams. Absence of significant differentiation with recurrent lithologies in the cumulitic pile of Dents de Bertol points to an efficiently convective magma chamber, with possible periodic replenishment, (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: In patients with septic shock, circulating monocytes become refractory to stimulation with microbial products. Whether this hyporesponsive state is induced by infection or is related to shock is unknown. To address this question, we measured TNF alpha production by monocytes or by whole blood obtained from healthy volunteers (controls), from patients with septic shock, from patients with severe infection (bacterial pneumonia) without shock, and from patients with cardiogenic shock without infection. MEASUREMENTS: The numbers of circulating monocytes, of CD14+ monocytes, and the expression of monocyte CD14 and the LPS receptor, were assessed by flow cytometry. Monocytes or whole blood were stimulated with lipopolysaccharide endotoxin (LPS), heat-killed Escherichia coli or Staphylococcus aureus, and TNF alpha production was measured by bioassay. RESULTS: The number of circulating monocytes, of CD14+ monocytes, and the monocyte CD14 expression were significantly lower in patients with septic shock than in controls, in patients with bacterial pneumonia or in those with cardiogenic shock (p < 0.001). Monocytes or whole blood of patients with septic shock exhibited a profound deficiency of TNF alpha production in response to all stimuli (p < 0.05 compared to controls). Whole blood of patients with cardiogenic shock also exhibited this defect (p < 0.05 compared to controls), although to a lesser extent, despite normal monocyte counts and normal CD14 expression. CONCLUSIONS: Unlike patients with bacterial pneumonia, patients with septic or cardiogenic shock display profoundly defective TNF alpha production in response to a broad range of infectious stimuli. Thus, down-regulation of cytokine production appears to occur in patients with systemic, but not localised, albeit severe, infections and also in patients with non-infectious circulatory failure. Whilst depletion of monocytes and reduced monocyte CD14 expression are likely to be critical components of the hyporesponsiveness observed in patients with septic shock, other as yet unidentified factors are at work in this group and in patients with cardiogenic shock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:: To examine the accuracy of brain multimodal monitoring-consisting of intracranial pressure, brain tissue PO2, and cerebral microdialysis-in detecting cerebral hypoperfusion in patients with severe traumatic brain injury. DESIGN:: Prospective single-center study. PATIENTS:: Patients with severe traumatic brain injury. SETTING:: Medico-surgical ICU, university hospital. INTERVENTION:: Intracranial pressure, brain tissue PO2, and cerebral microdialysis monitoring (right frontal lobe, apparently normal tissue) combined with cerebral blood flow measurements using perfusion CT. MEASUREMENTS AND MAIN RESULTS:: Cerebral blood flow was measured using perfusion CT in tissue area around intracranial monitoring (regional cerebral blood flow) and in bilateral supra-ventricular brain areas (global cerebral blood flow) and was matched to cerebral physiologic variables. The accuracy of intracranial monitoring to predict cerebral hypoperfusion (defined as an oligemic regional cerebral blood flow < 35 mL/100 g/min) was examined using area under the receiver-operating characteristic curves. Thirty perfusion CT scans (median, 27 hr [interquartile range, 20-45] after traumatic brain injury) were performed on 27 patients (age, 39 yr [24-54 yr]; Glasgow Coma Scale, 7 [6-8]; 24/27 [89%] with diffuse injury). Regional cerebral blood flow correlated significantly with global cerebral blood flow (Pearson r = 0.70, p < 0.01). Compared with normal regional cerebral blood flow (n = 16), low regional cerebral blood flow (n = 14) measurements had a higher proportion of samples with intracranial pressure more than 20 mm Hg (13% vs 30%), brain tissue PO2 less than 20 mm Hg (9% vs 20%), cerebral microdialysis glucose less than 1 mmol/L (22% vs 57%), and lactate/pyruvate ratio more than 40 (4% vs 14%; all p < 0.05). Compared with intracranial pressure monitoring alone (area under the receiver-operating characteristic curve, 0.74 [95% CI, 0.61-0.87]), monitoring intracranial pressure + brain tissue PO2 (area under the receiver-operating characteristic curve, 0.84 [0.74-0.93]) or intracranial pressure + brain tissue PO2+ cerebral microdialysis (area under the receiver-operating characteristic curve, 0.88 [0.79-0.96]) was significantly more accurate in predicting low regional cerebral blood flow (both p < 0.05). CONCLUSION:: Brain multimodal monitoring-including intracranial pressure, brain tissue PO2, and cerebral microdialysis-is more accurate than intracranial pressure monitoring alone in detecting cerebral hypoperfusion at the bedside in patients with severe traumatic brain injury and predominantly diffuse injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recommended oral voriconazole (VRC) doses are lower than intravenous doses. Because plasma concentrations impact efficacy and safety of therapy, optimizing individual drug exposure may improve these outcomes. METHODS: A population pharmacokinetic analysis (NONMEM) was performed on 505 plasma concentration measurements involving 55 patients with invasive mycoses who received recommended VRC doses. RESULTS: A 1-compartment model with first-order absorption and elimination best fitted the data. VRC clearance was 5.2 L/h, the volume of distribution was 92 L, the absorption rate constant was 1.1 hour(-1), and oral bioavailability was 0.63. Severe cholestasis decreased VRC elimination by 52%. A large interpatient variability was observed on clearance (coefficient of variation [CV], 40%) and bioavailability (CV 84%), and an interoccasion variability was observed on bioavailability (CV, 93%). Lack of response to therapy occurred in 12 of 55 patients (22%), and grade 3 neurotoxicity occurred in 5 of 55 patients (9%). A logistic multivariate regression analysis revealed an independent association between VRC trough concentrations and probability of response or neurotoxicity by identifying a therapeutic range of 1.5 mg/L (>85% probability of response) to 4.5 mg/L (<15% probability of neurotoxicity). Population-based simulations with the recommended 200 mg oral or 300 mg intravenous twice-daily regimens predicted probabilities of 49% and 87%, respectively, for achievement of 1.5 mg/L and of 8% and 37%, respectively, for achievement of 4.5 mg/L. With 300-400 mg twice-daily oral doses and 200-300 mg twice-daily intravenous doses, the predicted probabilities of achieving the lower target concentration were 68%-78% for the oral regimen and 70%-87% for the intravenous regimen, and the predicted probabilities of achieving the upper target concentration were 19%-29% for the oral regimen and 18%-37% for the intravenous regimen. CONCLUSIONS: Higher oral than intravenous VRC doses, followed by individualized adjustments based on measured plasma concentrations, improve achievement of the therapeutic target that maximizes the probability of therapeutic response and minimizes the probability of neurotoxicity. These findings challenge dose recommendations for VRC.