998 resultados para Cobalt(iii)
Resumo:
We carried out an electrochemical study of the cobalt electrodeposition onto glassy carbon electrode from an aqueous solution containing 10-2 M of CoSO4 + 1 M (NH4)2SO4 at natural pH 4.5. The potentiostatic study indicated a progressive 3D nucleation and growth during the deposition process. The average diffusion coefficient calculated for this system was 2.65 X 10-6 cm² s-1 while the ΔG for the formation of stable nucleus was 6.50 X 10-20 J/nuclei. The scanning electron microscopy images indicated the formation of small and homogeneous nucleus onto GCE of approximately 300 nm.
Resumo:
Arkit: A-C4.
Resumo:
Arkit: A-B4 C2.
Resumo:
It was carried out an electrochemical study of the cobalt electrodeposition onto HOPG electrode from an aqueous solution containing 10-2 M of CoSO4 + 1M (NH4)2SO4. Nucleation parameters such as nucleation rate, density of active nucleation sites, saturation nucleus and the rate constant of the proton reduction reaction (kPR) were determined from potentiostatic studies. An increase in kPR values with the decrease in the applied potential suggested a competition between H+ and Co2+ by the active sites on the surface. The ΔG energy calculated for the formation of stable nucleus was 8.21x10-21 J/nuclei. The AFM study indicated the formation of small clusters of 50-400 nm in diameter and 2-120 nm in height.
Resumo:
This study aimed the use of coal mining waste as a new adsorbent for H3O+ and removal of Al (III), Fe (III) and Mn (II) from acid mine drainage. Data from kinetic and equilibrium of the adsorption of H3O+ followed the pseudo second-order and Langmuir isotherm models. The maximum adsorption capacity of H3O+ was 316 mmol kg-1. The adsorbent removed 100% of Al (III), 100% of Fe (III) and 89% of Mn (II), suggesting its use as an alternative for the treatment of acid mine drainage.
Resumo:
Invocatio: I.N.S.S.T.
Resumo:
The clay mineral montmorillonite-K10 (MT), treated under acidic medium and saturated with potassium ions (MTK), was employed in sorption and desorption studies aiming the preconcentration of Cr(III) and the speciation analysis of chromium. The sorption process of Cr(III) was close to 100%, suggesting that MTK was a good material for Cr(III) preconcentration, although, the maximum recovery in HNO3 solution was near 89%. On the other hand, Cr(VI) practically was not retained in MTK, suggesting this material as an appropriate mineral phase to be used in speciation analysis of chromium in aqueous medium.
Resumo:
Ajankohtaista
Resumo:
Zeolite-encapsulated complexes have been widely applied in hydrocarbon oxidation catalysis. The "ship-in-a-bottle" encapsulation of iron(III) complexes containing piperazine and piperazine-derivative ligands in zeolite-Y is described. The flexible ligand methodology was employed and the efficiency and reproducibility of the procedure was investigated. The catalysts were characterized employing several techniques and the results indicate the presence of coordinated and uncoordinated iron(III) ions inside and outside the zeolitic cage.
Resumo:
The present paper focuses on improving chromium (III) uptake capacity of sugarcane bagasse through its chemical modification with citric acid and/or sodium hydroxide. The chemical modifications were confirmed by infrared spectroscopy, with an evident peak observed at 1730 cm-1, attributed to carbonyl groups. Equilibrium was reached after 24 h, and the kinetics followed the pseudo-second-order model. The highest chromium (III) maximum adsorption capacity (MAC) value was found when using sugarcane bagasse modified with sodium hydroxide and citric acid (58.00 mg g-1) giving a MAC value about three times greater (20.34 mg g-1) than for raw sugarcane bagasse.
Resumo:
Ajankohtaista
Resumo:
A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.
Resumo:
A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.
Resumo:
Flavonoids are one of the most important compound groups applied as medicine given their antioxidant properties, but several intrinsic properties can be improved through structural modifications to their molecules. Here, the synthesis and characterization of a new gallium (III) complex with quercetin is described. Electrochemical properties, as well as antioxidant and cytotoxic activities, were investigated and compared to the free flavonoid molecule. The mononuclear complex obtained, [Ga(C15H9O7)3].2H2O.2CH3OH.CH3CH2OH, seems more active as a DPPH radical scavenger given its lower oxidation potential compared to quercetin. The new complex cytotoxic responses have shown to be more effective than those of the free flavonoid and of lapachol used as a control.
Resumo:
A sensitive spectrophotometric method was developed for sulphate determination in automotive ethanol fuel. The method based on the reaction of the analyte with barium-dibromosulphonazo(III) complex lead to a decrease in the magnitude of the absorbance signals monitored at 649 nm. No sample pretreatment is required and the proposed method allows sulphate determination in the 0.45 - 6.50 mg L-1 range with R.S.D. < 2% and limit of detection of 0.14 mg L-1. The method has been successfully applied for sulphate determination in automotive ethanol fuel and the results agreed with the reference chromatographic method.