981 resultados para Château-Thierry (Aisne)


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report about a lung-on-chip array that mimics the pulmonary parenchymal environment, including the thin, alveolar barrier and the three-dimensional cyclic strain induced by the breathing movements. A micro-diaphragm used to stretch the alveolar barrier is inspired by the in-vivo diaphragm, the main muscle responsible for inspiration. The design of this device aims not only at best reproducing the in-vivo conditions found in the lung parenchyma, but also at making its handling easy and robust. An innovative concept, based on the reversible bonding of the device, is presented that enables to accurately control the concentration of cells cultured on the membrane by easily accessing both sides of the membranes. The functionality of the alveolar barrier could be restored by co-culturing epithelial and endothelial cells that formed tight monolayers on each side of a thin, porous and stretchable membrane. We showed that cyclic stretch significantly affects the permeability properties of epithelial cell layers. Furthermore, we could also demonstrate that the strain influences the metabolic activity and the cytokine secretion of primary human pulmonary alveolar epithelial cells obtained from patients. These results demonstrate the potential of this device and confirm the importance of the mechanical strain induced by the breathing in pulmonary research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acquired Fanconi syndrome is characterized by inappropriate urinary loss of amino acids, bicarbonate, electrolytes, and water. It has recently been described in dogs fed chicken jerky treats from China, a new differential diagnosis to the classical inciting infectious diseases (e.g. leptospirosis, pyelonephritis) and toxins. A dog fed exclusively chicken jerky treats purchased in Switzerland was presented to our clinic with severe polyuria, polydipsia and profound electrolyte and acid base disturbances. Other inciting causes of Fanconi syndrome were ruled out. The requirement of a very intensive supportive treatment in this dog stands in contrast to treatment of chronic forms of Fanconi syndrome as described in the Basenji. This intensive therapy and the associated monitoring can be a real challenge and a limiting factor for the prognosis of acquired Fanconi syndrome. Veterinarians should be aware of the risk of excessive feeding of chicken jerky treats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transapical transcatheter aortic valve implantation (TA-TAVI) is the recognized first choice surgical TAVI access. Expansion of this well-established treatment modality with subsequent broader patient inclusion has accelerated development of second-generation TA-TAVI devices. The Swiss ACURATE TA Symetis valve allows for excellent anatomical positioning, resulting in a very low incidence of paravalvular leaks. The self-expanding stent features an hourglass shape to wedge the native aortic valve annulus. A specially designed delivery system facilitates controlled release aided by tactile operator feedback. The ACURATE TA valve made of three native porcine non-coronary leaflets has received CE approval in September 2011. Since then, this valve is the third most frequently implanted TAVI device with over 1200 implants in Europe and South America. Results from the Symetis ACURATE TA™ Valve Implantation ('SAVI') Registry showed a procedural success rate of 98.0% and a survival rate of 93.2% at 30 days. This presentation provides technical considerations and detailed procedural aspects of device implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In patients with cardiogenic shock, data on the comparative safety and efficacy of drug-eluting stents (DESs) vs. bare metal stents (BMSs) are lacking. We sought to assess the performance of DESs compared with BMSs among patients with cardiogenic shock undergoing percutaneous coronary intervention (PCI). METHODS Out of 236 patients with acute coronary syndromes complicated by cardiogenic shock, 203 were included in the final analysis. The primary endpoint included death, and the secondary endpoint of major adverse cardiac and cerebrovascular events (MACCEs) included the composite of death, myocardial infarction, any repeat revascularization and stroke. Patients were followed for a minimum of 30 days and up to 4 years. As stent assignment was not random, we performed a propensity score analysis to minimize potential bias. RESULTS Among patients treated with DESs, there was a lower risk of the primary and secondary endpoints compared with BMSs at 30 days (29 vs. 56%, P < 0.001; 34 vs. 58%, P = 0.001, respectively) and during long-term follow-up [hazard ratio 0.43, 95% confidence interval (CI) 0.29-0.65, P < 0.001; hazard ratio 0.49, 95% CI 0.34-0.71, P < 0.001, respectively]. After propensity score adjustment, all-cause mortality was reduced among patients treated with DESs compared with BMSs both at 30 days [adjusted odds ratio (OR) 0.26, 95% CI 0.11-0.62; P = 0.002] and during long-term follow-up (adjusted hazard ratio 0.40, 95% CI 0.22-0.72; P = 0.002). The rate of MACCE was lower among patients treated with DESs compared with those treated with BMSs at 30 days (adjusted OR 0.42, 95% CI 0.19-0.95; P = 0.036). The difference in MACCEs between devices approached significance during long-term follow-up (adjusted hazard ratio 0.60, 95% CI 0.34-1.01; P = 0.052). CONCLUSION DESs appear to be associated with improved clinical outcomes, including a reduction in all-cause mortality compared with BMSs among patients undergoing PCI for cardiogenic shock, possibly because of a pacification of the infarct-related artery by anti-inflammatory drug. The results of this observational study require confirmation in an appropriately powered randomized trial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Acute kidney injury (AKI) is common in dogs. Few studies have assessed sequential changes in indices of kidney function in dogs with naturally occurring AKI. OBJECTIVE To document sequential changes of conventional indices of renal function, to better define the course of AKI, and to identify a candidate marker for recovery. ANIMALS Ten dogs with AKI. METHODS Dogs were prospectively enrolled and divided into surviving and nonsurviving dogs. Urine production was measured with a closed system for 7 days. One and 24-hour urinary clearances were performed daily to estimate solute excretion and glomerular filtration rate (GFR). Solute excretion was calculated as an excretion ratio (ER) and fractional clearance (FC) based on both the 1- and 24-hour urine collections. RESULTS Four dogs survived and 6 died. At presentation, GFR was not significantly different between the outcome groups, but significantly (P = .03) increased over time in the surviving, but not in the nonsurviving dogs. Fractional clearance of Na decreased significantly over time (20.2-9.4%, P < .0001) in the surviving, but not in the nonsurviving dogs. The ER and FC of solutes were highly correlated (r, 0.70-0.95). CONCLUSION AND CLINICAL IMPACT Excretion ratio might be used in the clinical setting as a surrogate marker to follow trends in solute excretion. Increased GFR, urine production, and decreased FC of Na were markers of renal recovery. The FC of Na is a simple, noninvasive, and cost-effective method that can be used to evaluate recovery of renal function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late lumen loss at 9 months. METHODS AND RESULTS A total of 452 patients were randomly assigned 2:1 to treatment with O-SES (298 patients, 332 lesions) or X-EES (154 patients, 173 lesions) in a multicenter, noninferiority trial. The primary end point was in-stent late loss at 9 months. O-SES was noninferior to X-EES for the primary end point (0.10±0.32 versus 0.11±0.29 mm; difference=0.00063 mm; 95% confidence interval, -0.06 to 0.07; Pnoninferiority<0.0001). Clinical outcome showed similar rates of target-lesion failure at 1 year (O-SES 6.5% versus X-EES 8.0%; hazard ratio=0.82; 95% confidence interval, 0.40-1.68; log-rank test: P=0.58) without cases of stent thrombosis. A subgroup of patients (n=55) underwent serial optical coherence tomography at 9 months, which demonstrated similar neointimal thickness among lesions allocated to O-SES and X-EES (0.10±0.04 mm versus 0.11±0.04 mm; -0.01 [-0.04, -0.01]; P=0.37). Another subgroup of patients (n=56) underwent serial intravascular ultrasound at baseline and 9 months indicating a potential difference in neointimal area at follow-up (O-SES, 0.16±0.33 mm(2) versus X-EES, 0.43±0.56 mm(2); P=0.04). CONCLUSIONS Compared with durable polymer X-EES, novel biodegradable polymer-based O-SES was found noninferior for the primary end point in-stent late lumen loss at 9 months. Clinical event rates were comparable without cases of stent thrombosis throughout 1 year of follow-up. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01356888.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Sporadic late-onset nemaline myopathy (SLONM) is a rare, late-onset myopathy that progresses subacutely. If associated with a monoclonal gammopathy of unknown significance (MGUS), the outcome is unfavorable: the majority of these patients die within 1 to 5 years of respiratory failure. This study aims to qualitatively assess the long-term treatment effect of high-dose melphalan (HDM) followed by autologous stem cell transplantation (SCT) in a series of 8 patients with SLONM-MGUS. METHODS We performed a retrospective case series study (n = 8) on the long-term (1-8 years) treatment effect of HDM followed by autologous SCT (HDM-SCT) on survival, muscle strength, and functional capacities. RESULTS Seven patients showed a lasting moderate-good clinical response, 2 of them after the second HDM-SCT. All of them had a complete, a very good partial, or a partial hematologic response. One patient showed no clinical or hematologic response and died. CONCLUSIONS This case series shows the positive effect of HDM-SCT in this rare disorder. Factors that may portend an unfavorable outcome are a long disease course before the hematologic treatment and a poor hematologic response. Age at onset, level and type of M protein (κ vs λ), and severity of muscle weakness were not associated with a specific outcome. CLASSIFICATION OF EVIDENCE This study provides Class IV evidence that for patients with SLONM-MGUS, HDM-SCT increases the probability of survival and functional improvement.