1000 resultados para Carcinogenicity testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbial processes in soil are moisture, nutrient and temperature dependent and, consequently, accurate calculation of soil temperature is important for modelling nitrogen processes. Microbial activity in soil occurs even at sub-zero temperatures so that, in northern latitudes, a method to calculate soil temperature under snow cover and in frozen soils is required. This paper describes a new and simple model to calculate daily values for soil temperature at various depths in both frozen and unfrozen soils. The model requires four parameters average soil thermal conductivity, specific beat capacity of soil, specific heat capacity due to freezing and thawing and an empirical snow parameter. Precipitation, air temperature and snow depth (measured or calculated) are needed as input variables. The proposed model was applied to five sites in different parts of Finland representing different climates and soil types. Observed soil temperatures at depths of 20 and 50 cm (September 1981-August 1990) were used for model calibration. The calibrated model was then tested using observed soil temperatures from September 1990 to August 2001. R-2-values of the calibration period varied between 0.87 and 0.96 at a depth of 20 cm and between 0.78 and 0.97 at 50 cm. R-2 -values of the testing period were between 0.87 and 0.94 at a depth of 20cm. and between 0.80 and 0.98 at 50cm. Thus, despite the simplifications made, the model was able to simulate soil temperature at these study sites. This simple model simulates soil temperature well in the uppermost soil layers where most of the nitrogen processes occur. The small number of parameters required means, that the model is suitable for addition to catchment scale models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report of a systematic review of Mersenne numbers 2^p-1 for p < 62982.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reports the factor-filtering and primality-testing of Mersenne Numbers Mp for p < 100000, the latter using the ICL 'DAP' Distributed Array Processor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The van der Heijden Studies Database has been reviewed to identify 'Draw Studies' with sub-7-man positions in the main line which are not draws. The data-mining method is described. Some 1,500 studies were faulted, 700 for the first time: 14 of the more interesting faults are highlighted and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compare laboratory observations of equilibrated baroclinic waves in the rotating two-layer annulus, with numerical simulations from a quasi-geostrophic model. The laboratory experiments lie well outside the quasi-geostrophic regime: the Rossby number reaches unity; the depth-to-width aspect ratio is large; and the fluid contains ageostrophic inertia–gravity waves. Despite being formally inapplicable, the quasi-geostrophic model captures the laboratory flows reasonably well. The model displays several systematic biases, which are consequences of its treatment of boundary layers and neglect of interfacial surface tension and which may be explained without invoking the dynamical effects of the moderate Rossby number, large aspect ratio or inertia–gravity waves. We conclude that quasi-geostrophic theory appears to continue to apply well outside its formal bounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The van der Heijden Studies Database (Version III) has been reviewed to identify 'Win Studies' with sub-7-man positions in the main line which are not wins for White. Some studies were faulted, A number for the first time: 21 of the more interesting escapes by Black are highlighted, themed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An eddy current testing system consists of a multi-sensor probe, a computer and a special expansion card and software for data-collection and analysis. The probe incorporates an excitation coil, and sensor coils; at least one sensor coil is a lateral current-normal coil and at least one is a current perturbation coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The principles of operation of an experimental prototype instrument known as J-SCAN are described along with the derivation of formulae for the rapid calculation of normalized impedances; the structure of the instrument; relevant probe design parameters; digital quantization errors; and approaches for the optimization of single frequency operation. An eddy current probe is used As the inductance element of a passive tuned-circuit which is repeatedly excited with short impulses. Each impulse excites an oscillation which is subject to decay dependent upon the values of the tuned-circuit components: resistance, inductance and capacitance. Changing conditions under the probe that affect the resistance and inductance of this circuit will thus be detected through changes in the transient response. These changes in transient response, oscillation frequency and rate of decay, are digitized, and then normalized values for probe resistance and inductance changes are calculated immediately in a micro processor. This approach coupled with a minimum analogue processing and maximum of digital processing has advantages compared with the conventional approaches to eddy current instruments. In particular there are: the absence of an out of balance condition and the flexibility and stability of digital data processing.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discussion of the numerical modeling of NDT methods based on the potential drop and the disruption of power lines to describe the nature, importance and application of modeling. La 1ère partie est consacrée aux applications aux contrôles par courants de Foucault. The first part is devoted to applications for inspection by eddy currents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control by voltage drop DC. Contrôle par chute de potentiel de courant alternatif. Control by voltage drop AC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An eddy current testing system consists of a multi-sensor probe, computer and a special expansion card and software for data collection and analysis. The probe incorporates an excitation coil, and sensor coils; at least one sensor coil is a lateral current-normal coil and at least one is a current perturbation coil.