949 resultados para CONVENTIONAL ANTIPSYCHOTICS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemotropic mycoplasmas, epicellular erythrocytic bacterial parasites lacking a cell wall, are the causative agents of infectious anemia in numerous mammalian species. The presence of hemotropic mycoplasmas in blood samples of neotropical and exotic wild canids and felids from Brazilian zoos were recorded using molecular techniques. Blood samples were collected from 146 Brazilian wild felids, 19 exotic felids, 3 European wolves (Canis lupus), and from 97 Brazilian wild canids from zoos in the Brazilian states of Sao Paulo and Mato Grosso and the Federal District. Using conventional polymerase chain reaction (PCR), this work found 22 (13%) wild felids positive to Candidatus Mycoplasma haemominutum [4 jaguars (Panthera onca); 3 pumas (Puma concolor); 10 ocelots (Leopardus pardalis); 2 jaguarondis (Puma yagouaroundi); and 3 little spotted cats (Leopardus tigrinus)]. Only one little spotted cat (Leopardus tigrinus) was positive to Mycoplasma haemofelis, and none was positive to Candidatus Mycoplasma turicensis. Two bush dogs (Speothos venaticus) were positive for a Mycoplasma sp. closely related to Candidatus Mycoplasma haematoparvum, and two European wolves were positive for a Mycoplasma sp. closely related to candidatus Mycoplasma haemominutum. This is the first study regarding the molecular detection of hemotropic mycoplasmas in wild canids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study we establish the concept of functionally graded fiber cement. We discuss the use of statistical mixture designs to choose formulations and present ideas for the production of functionally graded fiber cement components for Hatschek machines. The feasibility of producing functionally graded fiber cement by grading PVA fiber content has been experimentally evaluated. Thermogravimetric analysis (TG) was employed to assess fiber distribution profiles and four-point bending tests were applied to evaluate the mechanical performance of both conventional and graded composites. The results show that grading PVA fiber content is an effective way to produce functionally graded fiber cement, which allows for a reduction of the total fiber volume without a significant reduction on modulus of rupture of composite. TG tests were found adequate to assess the fiber content at different points in functionally graded fiber cements. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study is to investigate the thermal performance of cool colored acrylic paints containing infrared reflective pigments in comparison to conventional colored acrylic paints of similar colors (white, brown and yellow) applied on sheets of corrugated fiber cement roofing. Evaluated properties are: color according to ASTM D 2244-89, the UV/VIS/NIR reflectance according to ASTM E 90396, and thermal performance by exposure to infrared radiation emitted from a lamp with the measurement of surface temperatures of the specimens with thermocouples connected to a data logging system. Results demonstrated that the cool colored paint formulations produced significantly higher NIR reflectance than conventional paints of similar colors, and that the surface temperatures were more than 10 degrees C lower than those of conventional paints when exposed to infrared radiation. The study shows that cool paints enhance thermal comfort inside buildings, which can reduce air conditioning costs. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a simple high-level programming language, endowed with resources that help encoding self-modifying programs. With this purpose, a conventional imperative language syntax (not explicitly stated in this paper) is incremented with special commands and statements forming an adaptive layer specially designed with focus on the dynamical changes to be applied to the code at run-time. The resulting language allows programmers to easily specify dynamic changes to their own program`s code. Such a language succeeds to allow programmers to effortless describe the dynamic logic of their adaptive applications. In this paper, we describe the most important aspects of the design and implementation of such a language. A small example is finally presented for illustration purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new methodology to estimate unbalanced harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The problem solving algorithm herein proposed makes use of data from various power quality meters, which can either be synchronized by high technology GPS devices or by using information from a fundamental frequency load flow, what makes the overall power quality monitoring system much less costly. The ES based harmonic estimation model is applied to a 14 bus network to compare its performance to a conventional Monte Carlo approach. It is also applied to a 50 bus subtransmission network in order to compare the three-phase and single-phase approaches as well as the robustness of the proposed method. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the need to simultaneously monitor voltage unbalance and harmonic distortions in addition to root-mean-square voltage values. An alternative way to obtain the parameters related to voltage unbalance at fundamental frequency as well as voltage harmonic distortions is here proposed, which is based on the representation of instantaneous values at the axes and at the instantaneous Euclidean norm. A new power-quality (PQ) index is then proposed to combine the effects of voltage unbalance and harmonic distortions. This new index is easily implemented into existing electronic power meters. This PQ index is determined from the analysis of temperature rise in induction motor windings, which were tested for long periods of time. This paper also shows that these voltage disturbances, which are harmful to the lifetime expectancy of motors, can be measured by alternative ways in relation to conventional methods. Although this paper deals with induction motors only, the results show the relevance for further studies on other pieces of equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes ail alternative configuration to conventional reverse osmosis (RO) desalination systems by incorporating the use of gravitational potential energy. The proposal suggests a model that can be viewed as the energy station of a RO desalination plant. Conventionally, RO plants use a high-pressure pump, powered by electricity or fossil fuel. The function of the pump is to send a flux of saline water to a group of semi-permeable membrane modules, capable of ""filtering"" the dissolved salts. In this proposed model, we intend to achieve a flux at the inlet of the membrane modules with a pressure high enough for the desalination process, without using, either electricity or fossil fuels. To do this we divised a hybrid system that uses both gravitational potential energy and wind energy. The technical viability of the alternative was theoretically proven by deductions based on physics and mathematics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the development of a prototype of a tubular linear induction motor applied to onshore oil exploitation, named MAT AE OS (which is the Portuguese acronym for Tubular Asynchronous Motor for Onshore Oil Exploitation). The function of this motor is to directly drive the sucker-rod pump installed in the down hole of the oil well. Considering the drawbacks and operational costs of the conventional oil extraction method, which is based on the walking beam and rod, string system, the developed prototype is intended to become a feasible alternative from both technical and economic points of view. At the present time, the MAT AE OS prototype is installed in a test bench at the Applied Electromagnetism Laboratory at the Escola Politecnica da Universidade de Sao Paulo. The complete testing system is controlled and supervised by special software, enabling good flexibility in operation, data acquisition, and performance analysis. The test results indicate that the motor develops a constant lift force along the pumping cycle, as shown by the measured dynamometric charts. Also, the evaluated electromechanical performance seems to be superior to that obtained by the traditional method. The system utilizing the MAT AE OS prototype allows the complete elimination of the rod string sets required by the conventional equipment, indicating that the new system may advantageously replace the surface mechanical components presently utilized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most post-processors for boundary element (BE) analysis use an auxiliary domain mesh to display domain results, working against the profitable modelling process of a pure boundary discretization. This paper introduces a novel visualization technique which preserves the basic properties of the boundary element methods. The proposed algorithm does not require any domain discretization and is based on the direct and automatic identification of isolines. Another critical aspect of the visualization of domain results in BE analysis is the effort required to evaluate results in interior points. In order to tackle this issue, the present article also provides a comparison between the performance of two different BE formulations (conventional and hybrid). In addition, this paper presents an overview of the most common post-processing and visualization techniques in BE analysis, such as the classical algorithms of scan line and the interpolation over a domain discretization. The results presented herein show that the proposed algorithm offers a very high performance compared with other visualization procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is well established, the importance of the measurement of soil suction for the assessment of mechanical and hydraulic behavior of unsaturated soils. Among the methods to obtain the soil suction, the tensiometer is one of the most convenient and reliable. However conventional tensiometer has a limitation related to the maximum suction it is capable of measure. This limitation was overcome by Ridley and Burland (1993), with the development of a high capacity tensiometer, which is capable of measure suction well above 100 kPa. The equipment has a quick response time, allowing the determination of suction in minutes. This paper presents a study about the factors that affect the equilibrium time for high capacity tensiometers in the laboratory. Soil specimens were prepared at three different conditions, creating different soil structures. In addition to that an investigation about the characteristic of the interface that is required between the soil sample and the porous ceramic of the tensiometer was carried out; showing the role of the paste on the technique. The results also suggested that it is possible to infer the hydraulic conductivity function using the equilibrium curve obtained during the measurement of the soil suction using the high capacity tensiometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of absorption refrigeration systems has had increasing importance in recent years due to the fact that the primary energy that is used in an absorption system can be heat available from a residual source or even a renewable one. Therefore, these systems not only use energy that would be rejected by the environment, but also they avoid the consumption of expensive fossil or electrical energies. The production cost of the mechanical work necessary to obtain a kW of refrigeration for mechanical compression cycle is normally higher than the cost for recovering the needed heat to obtain the same kW in an absorption cycle. Also, the use of these systems reduces impact on the environment by decreasing the emission of CO(2). We intend to show the performance of a hybrid absorption-ejecto compression chiller compared to conventional double- and single-effect water/lithium bromide systems, by means of an exergetic and exergoeconomic analysis of these configurations in order to calculate the exergy-based cost of a final product. The vapor compression refrigeration system is included in the results, as a comparisson to the performance of the absorption refrigeration systems analyzed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present work is to elucidate the influence of lubricants on the friction behavior of zinc phosphated coatings and provide an explanation for the results in terms of physical-chemical interactions between lubricant and phosphate. The friction behavior was studied through a sliding wear test, with a conventional ball-on-disc configuration. Discs, made of AISI 1006 low carbon steel. uncoated and coated with zinc phosphate, were tested against bearing steel balls. A stearate sodium soap, paraffinic oil and both soap and oil were used as lubricants. The sodium stearate soap was found to have the best seizure resistance. The nature of the interfacial forces between the lubricant and surface has an important role in determining the friction behavior. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A methodology for rock-excavation structural-reliability analysis that uses Distinct Element Method numerical models is presented. The methodology solves the problem of the conventional numerical models that supply only punctual results and use fixed input parameters, without considering its statistical errors. The analysis of rock-excavation stability must consider uncertainties from geological variability, from uncertainty in the choice of mechanical behaviour hypothesis, and from uncertainties in parameters adopted in numerical model construction. These uncertainties can be analyzed in simple deterministic models, but a new methodology was developed for numerical models with results of several natures. The methodology is based on Monte Carlo simulations and uses principles of Paraconsistent Logic. It will be presented in the analysis of a final slope of a large-dimensioned surface mine.