998 resultados para Bleaching agents - Citotoxicity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A solução cardioplégica farmacológica busca eliminar as conseqüências do dano isquêmico, que é o resultado do desbalanço entre a oferta e o consumo de energia durante a parada dos batimentos cardíacos, nas cirurgias cardíacas com circulação extracorpórea. OBJETIVO: Este trabalho avalia experimentalmente as alterações estruturais e ultra-estruturais em coração isolado de coelhos submetidos à parada protegida pela Solução para Cardioplegia de Baixo Volume (SCBV). MÉTODO: O estudo compreendeu um grupo controle e dois grupos experimentais. No grupo I, a parada cardíaca foi obtida pela infusão da SCBV por 2 horas. No grupo II, o experimento foi conduzido da mesma forma até a parada protegida pela SCBV por duas horas, imediatamente procedeu-se à reperfusão com solução oxigenada de Ringer Locke (RL) por uma hora. No grupo controle os corações foram perfundidos com solução oxigenada de RL por duas horas. Após os experimentos, oito amostras de parede lateral do ventrículo esquerdo foram fixadas em formaldeído 10% e glutaraldeído 2,5% para análises histológica e ultra-estrutural. RESULTADOS: As células do miocárdio, fibroblastos e células endoteliais, observadas nos grupos experimentais I e II, apresentaram marginalização da heterocromatina, compactação do nucléolo, alteração na forma das mitocôndrias, compactação das cristas e aumento da densidade da matriz mitocondrial, indicando que tanto a estrutura nuclear quanto a das organelas citoplasmáticas foram alteradas em relação às células do grupo controle. CONCLUSÃO: As modificações estruturais foram decorrentes de uma adaptação fisiológica da célula, não sendo indicativas de oncose ou apoptose, sugerindo, portanto, que a solução cardioplégica utilizada foi eficiente para a preservação das células.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of the xylanase in the pulp bleaching process has been shown to be effective in decreasing the amount of chlorinating agents in the process and improving the brightness of the pulp. The use of thermostable cellulase-free xylanase might enhance both the technical and economic feasibility of the process. In this work an alkalophylic strain of Bacillus sp 77-2, was isolated which showed a high production of xylanase and free cellulases. The xylanase of Bacillus sp displayed an optimum pH of 6.0 (with 70% activity at pH 9.0), all optimum temperature of 60 degrees C, pH stability in the range 5-10 and thermal stability of 50 degrees C. These characteristics are important to the kraft pulp bleaching because they are similar to those found in the industrial paper environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alkalophilic Bacillus licheniformis 77-2 produced an extracellular alkali-tolerant xylanase with negligible cellulase activity in medium containing corn straw. The effectiveness of crude xylanase on treatment of eucalyptus Kraft pulp was evaluated. A biobleaching experiment was carried out to compare the chlorine saving with pulp treated and untreated by the enzyme. Two-stage bleaching was employed, using a ClO2 chlorination and NaOH extraction (DE sequence). With the enzymatic treatment, in order to obtain the same value of Kappa number and brightness, respectively 28.5 and 30% less ClO2 was required in comparison to the enzymatically untreated samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of the elapsed time (ET) after nonvital bleaching (NVB) and sodium ascorbate application (10%) (SAA) on the shear bond strength of dentin to ceramic.Materials and Methods: Bovine incisors were selected, internally bleached (35% carbamide peroxide) for 9 days and submitted to the following treatments (n = 10): G1, G2, G3-luting after 1, 7, and 14 days; G4, G5, and G6-luting after SAA, 1, 7, and 14 days, respectively. G7 and G8 were not bleached: G7-luting 24 hours after access cavity sealing; G8-luting 24 hours after access cavity sealing after SAA. After NVB, the vestibular dentin was exposed and flattened. The SAA was applied to the dentin (G4, G5, G6, G8) for 10 minutes, and it was then washed and dried. The dentin was etched (37% phosphoric acid), and an adhesive system (Single Bond 2) was applied. Feldspathic ceramic discs (VM7; 4-mm diameter, 3-mm thick) were luted with a dual-resin agent (RelyX ARC, 3M ESPE Dental Products, St. Paul, MN). After 24 hours, specimens were submitted to shear test on a universal testing machine. The data (MPa) were submitted to ANOVA and Dunnet's test (5%).Results: The means (+/- SD) obtained were (MPa): G1 (14 +/- 4.5), G2 (14.6 +/- 3.1), G3 (14 +/- 3.7), G4 (15.5 +/- 4.6), G5 (19.87 +/- 4.5), G6 (16.5 +/- 3.7), G7 (22.8 +/- 6.2), and G8 (18.9 +/- 5.4). SAA had a significant effect on bond strength (p = 0.0054). The effect of ET was not significant (p = 0.1519). G5 and G6 presented higher values than the other bleached groups (p < 0.05) and similar to G7 and G8 (p > 0.05).Conclusions: After NVB, adhesive luting to dentin is recommended after 7 days if sodium ascorbate has been applied prior to dentin hybridization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed alterations on bovine enamel after excessive bleaching. Coronal portions of bovine teeth (n = 30) were sectioned and divided into three groups (n = 10 per group). The coronal parts were further cut incisocervically into two halves. While one half received no bleaching (control), the other half was subjected to either one (group 1), three (group 2), or five bleaching sessions (group 3) with 35% hydrogen peroxide. The enamel surfaces were then analyzed using scanning electron microscopy and energy dispersive x-ray spectroscopy (EDS). Fxcessive bleaching affected the surface morphology and chemistry of the bovine enamel. EDS analysis showed the highest decrease in calcium ion percentages in groups 2 and 3 when compared to their nonbleached halves. Oxygen and phosphorus percentages were comparable on both the control and bleached enamel, regardless of the number of bleaching sessions. Consecutive bleaching sessions with 35% hydrogen peroxide may lead to morphologic and specific elemental changes when performed in a short period of time. Calcium ion percentages may decrease when this bleaching agent is used for more than one session. Int J Prosthodontics 2010;23:29-32.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the intrapulpal temperature variation after bleaching treatment with 35% hydrogen peroxide using different sources of activation. Material and Methods: Twenty-four human teeth were sectioned in the mesiodistal direction providing 48 specimens, and were divided into 4 groups (n=12): (G1) Control - Bleaching gel without light activation, (G2) Bleaching gel + halogen light, (G3) Bleaching gel + LED, (G4) Bleaching gel + Nd: YAG Laser. The temperatures were recorded using a digital thermometer at 4 time points: before bleaching gel application, 1 min after bleaching gel application, during activation of the bleaching gel, and after the bleaching agent turned from a dark-red into a clear gel. Data were analyzed statistically by the Dunnet's test, ANOVA and Tukey's test (alpha=0.05). Results: The mean intrapulpal temperature values (degrees C) in the groups were: G1: 0.617 +/- 0.41; G2: 1.800 +/- 0.68; G3: 0.975 +/- 0.51; and G4: 4.325 +/- 1.09. The mean maximum temperature variation (MTV) values were: 1.5 degrees C (G1), 2.9 degrees C (G2), 1.7 degrees C (G3) and 6.9 degrees C (G4). When comparing the experimental groups to the control group, G3 was not statistically different from G1 (p>0.05), but G2 and G4 presented significantly higher (p<0.05) intrapulpal temperatures and MTV. The three experimental groups differed significantly (p<0.05) from each other. Conclusions: The Nd: YAG laser was the activation method that presented the highest values of intrapulpal temperature variation when compared with LED and halogen light. The group activated by LED light presented the lowest values of temperature variation, which were similar to that of the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of bleaching gel containing 10%, 15% and 20% carbamide peroxide (CP) on the bond strength of dental enamel or dentin and resin composite restorations.Methods: The buccal surfaces of 12 bovine tooth crowns were conditioned with 37% phosphoric acid, and the adhesive resin Single Bond 2 and the resin composite Filtek Z350 were used to perform the restorations. The blocks were sectioned to obtain bar specimens. Each specimen group (enamel-E, dentin-D) was divided into four subgroups (n=15): S-artificial saliva; 10-10% CP bleaching; 15-15% CP bleaching; 20-20% CP bleaching. CP was applied for six hours daily for two weeks. The specimens were submitted to the a test in a universal testing machine. The data were analyzed by one-way ANOVA and the Tukey post-hoc test and a correlation analysis (r) was performed.Results: For Group E, the mean value (+/- standard-deviation) was 21.86 (+/- 6.03)a, 18.91 (+/- 8.31)ab, 15.43 (+/- 7.44)b and 10.6 (+/- 4.94)c for ES, E10, E15 and E20, respectively. For Group D, the alpha values were 34.73 (+/- 4.68)a, 35.12 (+/- 13.43)a, 29.67 (+/- 6.84)ab and 24.56 (+/- 6.54)b for DS, D10, D15 and D20, respectively. A negative correlation between the CP concentration and mean values was observed for both the enamel (r=-0.95) and dentin (r=-0.85) groups.Conclusion: In the current study, the bond strength of the restoration to enamel and the restoration to dentin were influenced by the application of CP and was dependent on the CP concentration in the bleaching gel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o selamento de ápices radiculares tratados com diferentes agentes desmineralizantes e retrobturados com agregado de trióxido mineral (MTA), mediante infiltração marginal por corante. Cinqüenta e seis dentes unirradiculares humanos extraídos foram instrumentados, obturados e seccionados apicalmente. Os preparos cavitários apicais foram confeccionados com pontas ultra-sônicas e os agentes desmineralizantes foram aplicados previamente à retrobturação com Pro Root MTA. Os espécimes foram divididos aleatoriamente em 4 grupos (n=14): grupo 1 (sem agente desmineralizante); grupo 2 (ácido fosfórico 35% durante 15 s); grupo 3 (solução de EDTA 17%, pH 7, durante 3 min); grupo 4 (gel de EDTA 24%, pH 7, durante 4 min). A extensão da infiltração de corante (rodamina B 2% a 37°C, por 24 h) foi avaliada em milímetros utilizando-se um estereomicroscópio. Os resultados foram analisados estatisticamente por meio de análise de variância a um critério e do teste Tukey com nível de significância de 5%. Dentre os grupos experimentais, a menor extensão de infiltração do corante foi verificada no grupo 1 (1,89 mm), seguido pelos grupos 2 (2,18 mm), 4 (2,54 mm) e 3 (2,64 mm). Não houve diferenças estatisticamente significante (p>0.05) na infiltração marginal pelo corante entre os grupos 1, 2 e 4 e os grupos 2, 3 e 4. Com base nos resultados obtidos, pode-se concluir que a aplicação de agentes desmineralizantes não pode ser recomendada quando da utilização do MTA em cirurgias parendodônticas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. METODOLOGIA: Foram empregados 60 dentes incisivos bovinos, com dimensões coronárias e radiculares padronizadas a partir do limite amelo-cementário, sendo descartada a porção lingual. Os corpos-de-prova (cp) foram limpos em ultra-som por 20 min e a dentina condicionada com H3PO4 a 38% por 15 s, sendo os (cp) imersos em solução de café solúvel a 25% por duas semanas. A dentina foi impermeabilizada com esmalte e os (cp) divididos em 5 grupos, sendo a cor inicial mensurada através do espectofotômetro-EasyShade (VITA). Todos os (cp) receberam três aplicações por 10 min do gel clareador Opalescence Xtra-Boost (Ultradent) conforme segue: Grupo 1 - controle, não recebeu fotoativação, Grupo 2 - ativado com luz halôgena, Grupo 3 - ativado com LED azul/LASER, Grupo 4 - ativado com LED verde/LASER e Grupo 5 - ativado com LED vermelho. Após o clareamento foi mensurada a variação de cor E, a*, b*e L* e as referentes à escala de cor Vita Clássico. Os dados foram submetidos à análise de variância, teste de Tukey e de Dunn (α=5%). RESULTADOS: A diferença geral da cor foi reduzida quando se empregou LED Azul e Luz Halógena, sendo que o desempenho do peróxido de hidrogênio a 38% foi intensificado dependendo da fonte de luz utilizada. A avaliação quantitativa de cor, obtida por espectrofotômetro e pela escala de cor Vita Clássico, foram coincidentes. CONCLUSÃO: O tipo de fonte de luz empregada interfere na eficácia do agente clareador.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of surfactants on the effectiveness of 35% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching gels. One hundred and forty bovine teeth were used, which were stained by immersion in a coffee, red wine, and tobacco mixture for 7 days. At the end of this process, the color measurement at baseline was taken with the Vita Easyshade spectrophotometer. The teeth were divided into seven groups: (a) negative control (NC), (b) positive control for HP (PC-35), (c) HP + Tween 20 (T20-35), (d) HP + laurel sodium sulfate (LSS-35), (e) positive control for CP (PC-10), (f) CP + Tween 20 (T20-10), and (g) CP + laurel sodium sulfate (LSS-10). Group NC was kept in artificial saliva for 21 days. Groups PC-35, T20-35, and LSS 35 received three applications of bleaching gel for 10 min; the process was repeated after 7 days. Groups PC-10, T20-10, and LSS-10 received the gel for 8 h per day for 14 days. After the bleaching process, the final color was measured. The analysis of variance and Tukey tests showed statistically significant differences for the parameters of a dagger L, a dagger b, and a dagger E of the HP gels with surfactant and positive control group (PC-35). Within the limits of this in vitro study, the addition of surfactants to HP bleaching gel increased the bleaching effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)