994 resultados para Bai f, Lazare de, 1496?-1547.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

his paper considers a problem of identification for a high dimensional nonlinear non-parametric system when only a limited data set is available. The algorithms are proposed for this purpose which exploit the relationship between the input variables and the output and further the inter-dependence of input variables so that the importance of the input variables can be established. A key to these algorithms is the non-parametric two stage input selection algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As the relative performance of alkali activated slag (AAS) concretes in comparison to Portland cement (PC) counterparts for chloride transport and resulting corrosion of steel bars is not clear, an investigation was carried out and the results are reported in this paper. The effect of alkali concentration and modulus of sodium silicate solution used in AAS was studied. Chloride transport and corrosion properties were assessed with the help of electrical resistivity, non-steady state chloride diffusivity, onset of corrosion, rate of corrosion and pore solution chemistry. It was found that: (i) although chloride content at surface was higher for the AAS concretes, they had lower chloride diffusivity than PC concrete; (ii) pore structure, ionic exchange and interaction effect of hydrates strongly influenced the chloride transport in the AAS concretes; (iii) steel corrosion resistance of the AAS concretes was comparable to that of PC concrete under intermittent chloride ponding regime, with the exception of 6% Na2O and Ms of 1.5; (iv) the corrosion behaviour of the AAS concretes was significantly influenced by ionic exchange, carbonation and sulphide concentration; (v) the increase of alkali concentration of the activator generally increased the resistance of AAS concretes to chloride transport and reduced its resulting corrosion, and a value of 1.5 was found to be an optimum modulus for the activator for improving the chloride transport and the corrosion resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

<p>Background: Unexplained chronic cough (UCC) causes significant quality of life impairment. There is a need to identify effective assessment and treatment approaches for UCC.</p><p>Methods: This systematic review of randomized controlled clinical trials asked: What is the efficacy of treatment compared to usual care on cough severity, cough frequency, and cough-related quality of life in patients with unexplained chronic cough (UCC)? Studies of adults and adolescents &gt;12 years with a chronic cough of &gt;8 weeks duration that was unexplained after systematic investigation and treatment were included and assessed for relevance and quality. Based upon the systematic review, guideline suggestions were developed and voted upon using CHEST organization methodology.</p><p>Results: 11 RCTs and 5 systematic reviews were included. The 11 RCTs reported data on 570 participants with chronic cough who received a variety of interventions. Study quality was high in 10 RCTs. The studies used a variety of descriptors and assessments to identify unexplained chronic cough. While gabapentin and morphine showed positive effects on cough-related quality of life, only gabapentin was supported as a treatment recommendation. Studies of inhaled corticosteroids (ICS) suffered from intervention fidelity bias, and when this was addressed, ICS were not found to be effective for UCC. Esomeprazole was not effective for UCC without features of gastroesophageal acid reflux. Studies addressing non-acid gastroesophageal reflux were not identified. A multimodality speech pathology intervention improved cough severity.</p><p>Conclusions: The evidence supporting the diagnosis and management of UCC is limited. UCC requires further study to establish agreed terminology and the optimal methods of investigation using established criteria for intervention fidelity. Speech pathology based cough suppression is suggested as a treatment option for UCC. This guideline presents suggestions for diagnosis and treatment based on the best available evidence and identifies gaps in our knowledge and areas for future research.</p>

Relevância:

10.00% 10.00%

Publicador:

Resumo:

<p>This paper reports on the accuracy of new test methods developed to measure the air and water permeability of high-performance concretes (HPCs). Five representative HPC and one normal concrete (NC) mixtures were tested to estimate both repeatability and reliability of the proposed methods. Repeatability acceptance was adjudged using values of signal-noise ratio (SNR) and discrimination ratio (DR), and reliability was investigated by comparing against standard laboratory-based test methods (i.e., the RILEM gas permeability test and BS EN water penetration test). With SNR and DR values satisfying recommended criteria, it was concluded that test repeatability error has no significant influence on results. In addition, the research confirmed strong positive relationships between the proposed test methods and existing standard permeability assessment techniques. Based on these findings, the proposed test methods show strong potential to become recognized as international methods for determining the permeability of HPCs.</p>

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shape stabilised phase change materials (SSPCMs) based on a high density poly(ethylene)(hv-HDPE) with high (H-PW, Tm = 56â58 °C) and low (L-PW, Tm = 18â23 °C) melting point paraffin waxes were readily prepared using twin-screw extrusion. The thermo-physical properties of these materials were assessed using a combination of techniques and their suitability for latent heat thermal energy storage (LHTES) assessed. The melt processing temperature (160 °C) of the HDPE used was well below the onset of thermal decomposition of H-PW (220 °C), but above that for L-PW (130 °C), although the decomposition process extended over a range of 120 °C and the residence time of L-PW in the extruder was &lt;30 s. The SSPCMs prepared had latent heats up to 89 J/g and the enthalpy values for H-PW in the respective blends decreased with increasing H-PW loading, as a consequence of co-crystallisation of H-PW and hv-HDPE. Static and dynamic mechanical analysis confirmed both waxes have a plasticisation effect on this HDPE. Irrespective of the mode of deformation (tension, flexural, compression) modulus and stress decreased with increased wax loading in the blend, but the H-PW blends were mechanically superior to those with L-PW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Good Laboratory Practice has been a part of non-clinical research for over 40 years. Optimization Research, despite having many papers discussing standards being published over the same period of time, has yet to embrace standards that underpin its research. In this paper we argue the need to adopt standards in optimization research. Building on previous papers, many of which have suggested that the optimization research community should adopt certain standards, we suggest a concrete set of recommendations that the community should adopt. We also discuss how the proposals in this paper could be progressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chloride-induced corrosion of steel in reinforced concrete structures is one of the main problems affecting their durability, but most previous research projects and case studies have focused on concretes without cracks or not subjected to any structural load. Although it has been recognised that structural cracks do influence the chloride transport and chloride induced corrosion in reinforced concrete structures, there is little published work on the influence of micro-cracks due to service loads on these properties. Therefore the effect of micro-cracks caused by loading on chloride transport into concrete was studied. Four different stress levels (0%, 25%, 50% and 75% of the stress at ultimate load â fu) were applied to 100 mm diameter concrete discs and chloride migration was measured using a bespoke test setup based on the NT BUILD 492 test. The effects of replacing Portland cement CEMI by ground granulated blast-furnace slag (GGBS), pulverised fuel ash (PFA) and silica fume (SF) on chloride transport in concrete under sustained loading were studied. The results have indicated that chloride migration coefficients changed little when the stress level was below 50% of the fu; however, it is desirable to keep concrete stress less than 25% fu if this is practical. The effect of removing the load on the change of chloride migration coefficient was also studied. A recovery of around 50% of the increased chloride migration coefficient was found in the case of concretes subjected to 75% of the fu when the load was removed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the first detection of a gap and a ring in dust continuum emission from the protoplanetary disk around TW Hya, using the Atacama Large Millimeter/Submillimeter Array. The gap and ring are located at 25 and 41 AU from the central star, respectively, and are associated with the CO snowline at ~ 30AU. The gap width and depth are 15AU at the maximum and 23% at the minimum, respectively, regarding that the observations are limited to an angular resolution of ~ 15AU. In addition, we detect a decrement in CO line emission down to ~ 10AU, indicating freeze-out of gas-phase CO onto grain surfaces and possible subsequent surface reactions to form larger molecules. According to theoretical studies, the gap could be caused by gravitational interaction between the disk gas and a planet with a mass less than super-Neptune (2 Neptune mass), or result from destruction of large dust aggregates due to the sintering of CO ice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A means of encoding and decoding data using wireless orbital angular momentum (OAM) modes is proposed and analysed. Source data symbols are used to select an OAM mode, which is generated using an 8-element circular array. A 2-element array is used to detect the mode by estimating the phase gradient of the received signal, and hence identifying the transmitted data symbol. The results are presented in terms of mode estimation error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basic mechanism underlying electric field switching produced by a resonant tunneling diode (RTD) is analyzed and the theory compared with experimental results; agreement to within 12% is achieved. The electroabsorption modulator (EAM) device potential of this effect is explored in an optical waveguide configuration. It is shown that a RTD-EAM can provide significant absorption coefficient change, via the Franzâ Keldysh effect, at appropriate optical communication wavelengths around 1550 nm and can achieve up to 28-dB optical modulation in a 200- m active length device. The advantage of the RTD-EAM over the conventional reverse-biased pân junction EAM, is that the RTD-EAM has, in essence, an integrated electronic amplifier and, therefore, requires considerably less switching power.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new design approach for a rail-to-rail bulk-driven input stage using a standard single-well (n-well in this paper) CMOS technology. This input stage can provide nearly constant transconductance and constant slew rate over the entire input common-mode voltage, operating with a wide supply voltage ranging from sub 1-volt (V/sub T0/+ 3V/sub DSsat/) to the maximum allowed for the CMOS process, as well as preventing latch-up.