921 resultados para Automated cataloguing
Resumo:
Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.
Resumo:
Background: Conventional magnetic resonance imaging (MRI) techniques are highly sensitive to detect multiple sclerosis (MS) plaques, enabling a quantitative assessment of inflammatory activity and lesion load. In quantitative analyses of focal lesions, manual or semi-automated segmentations have been widely used to compute the total number of lesions and the total lesion volume. These techniques, however, are both challenging and time-consuming, being also prone to intra-observer and inter-observer variability.Aim: To develop an automated approach to segment brain tissues and MS lesions from brain MRI images. The goal is to reduce the user interaction and to provide an objective tool that eliminates the inter- and intra-observer variability.Methods: Based on the recent methods developed by Souplet et al. and de Boer et al., we propose a novel pipeline which includes the following steps: bias correction, skull stripping, atlas registration, tissue classification, and lesion segmentation. After the initial pre-processing steps, a MRI scan is automatically segmented into 4 classes: white matter (WM), grey matter (GM), cerebrospinal fluid (CSF) and partial volume. An expectation maximisation method which fits a multivariate Gaussian mixture model to T1-w, T2-w and PD-w images is used for this purpose. Based on the obtained tissue masks and using the estimated GM mean and variance, we apply an intensity threshold to the FLAIR image, which provides the lesion segmentation. With the aim of improving this initial result, spatial information coming from the neighbouring tissue labels is used to refine the final lesion segmentation.Results:The experimental evaluation was performed using real data sets of 1.5T and the corresponding ground truth annotations provided by expert radiologists. The following values were obtained: 64% of true positive (TP) fraction, 80% of false positive (FP) fraction, and an average surface distance of 7.89 mm. The results of our approach were quantitatively compared to our implementations of the works of Souplet et al. and de Boer et al., obtaining higher TP and lower FP values.Conclusion: Promising MS lesion segmentation results have been obtained in terms of TP. However, the high number of FP which is still a well-known problem of all the automated MS lesion segmentation approaches has to be improved in order to use them for the standard clinical practice. Our future work will focus on tackling this issue.
Resumo:
Objective: Small nodal tumor infiltrates are identified by applying multilevel sectioning and immunohistochemistry (IHC) in addition to H&E (hematoxylin and eosin) stains of resected lymph nodes. However, the use of multilevel sectioning and IHC is very time-consuming and costly. The current standard analysis of lymph nodes in colon cancer patients is based on one slide per lymph node stained by H&E. A new molecular diagnostic system called ''One tep Nucleic Acid Amplification'' (OSNA) was designed for a more accurate detection of lymph node metastases. The objective of the present investigation was to compare the performance ofOSNAto current standard histology (H&E). We hypothesize that OSNA provides a better staging than the routine use of one slide H&E per lymph node.Methods: From 22 colon cancer patients 307 frozen lymph nodes were used to compare OSNA with H&E. The lymph nodes were cut into halves. One half of the lymph node was analyzed by OSNA. The semi-automated OSNA uses amplification of reverse-transcribed cytokeratin19 (CK19) mRNA directly from the homogenate. The remaining tissue was dedicated to histology, with 5 levels of H&E and IHC staining (CK19).Results: On routine evaluation of oneH&Eslide 7 patients were nodal positive (macro-metastases). All these patients were recognized by OSNA analysis as being positive (sensitivity 100%). Two of the remaining 15 patients had lymph node micro-metastases and 9 isolated tumor cells. For the patients with micrometastases both H&E and OSNA were positive in 1 of the 2 patients. For patients with isolated tumor cells, H&E was positive in 1/9 cases whereas OSNA was positive in 3/9 patients (IHC as a reference). There was only one case to be described as IHC negative/OSNA positive. On the basis of single lymph nodes the sensitivity of OSNA and the 5 levels of H&E and IHC was 94・5%.Conclusion: OSNA is a novel molecular tool for the detection of lymph node metastases in colon cancer patients which provides better staging compared to the current standard evaluation of one slide H&E stain. Since the use of OSNA allows the analysis of the whole lymph node, sampling bias and undetected tumor deposits due to uninvestigated material will be overcome. OSNA improves staging in colon cancer patients and may replace the current standard of H&E staining in the future.
Resumo:
BACKGROUND: The activity of the renin-angiotensin system is usually evaluated as plasma renin activity (PRA, ngAI/ml per h) but the reproducibility of this enzymatic assay is notoriously scarce. We compared the inter and intralaboratory reproducibilities of PRA with those of a new automated chemiluminescent assay, which allows the direct quantification of immunoreactive renin [chemiluminescent immunoreactive renin (CLIR), microU/ml]. METHODS: Aliquots from six pool plasmas of patients with very low to very high PRA levels were measured in 12 centres with both the enzymatic and the direct assays. The same methods were applied to three control plasma preparations with known renin content. RESULTS: In pool plasmas, mean PRA values ranged from 0.14 +/- 0.08 to 18.9 +/- 4.1 ngAI/ml per h, whereas those of CLIR ranged from 4.2 +/- 1.7 to 436 +/- 47 microU/ml. In control plasmas, mean values of PRA and of CLIR were always within the expected range. Overall, there was a significant correlation between the two methods (r = 0.73, P < 0.01). Similar correlations were found in plasmas subdivided in those with low, intermediate and high PRA. However, the coefficients of variation among laboratories found for PRA were always higher than those of CLIR, ranging from 59.4 to 17.1% for PRA, and from 41.0 to 10.7% for CLIR (P < 0.01). Also, the mean intralaboratory variability was higher for PRA than for CLIR, being respectively, 8.5 and 4.5% (P < 0.01). CONCLUSION: The measurement of renin with the chemiluminescent method is a reliable alternative to PRA, having the advantage of a superior inter and intralaboratory reproducibility.
Resumo:
Aquest projecte es dirigeix a tots aquells docents que gestionen informació d'activitats dinvestigació des de diferents eines tecnològiques i que precisen de connexió a Internet i de diverses Webs. Per centralitzar aquestes dades, neix TeachPro, un software automatitzat que gestiona i emmagatzema informació sobre les activitats de gestió per tal que l'usuari en disposi de manera ràpida i organitzada. Tot això, sense connexió a Internet. Les dades són gestionades mitjançant una interfície a partir de la qual l'usuari podrà consultar, afegir, modificar, o eliminar tota aquella informació que desitgi. Totes aquestes dades seran emmagatzemades en una base de dades local.
Resumo:
Este proyecto consiste en el desarrollo de una aplicación informática que permite gestionar de forma automatizada y consistente los datos requeridos para la actividad docente de un profesor universitario. La aplicación permite gestionar: plan docente, asignaturas, horario docente, calendario de exámenes y proyectos final de carrera. Todas estas opciones tienen las funciones de, agregar, buscar, modificar y eliminar datos. Además tiene otras opciones como calendario docente y webs, cuya finalidad será consultar, de forma directa, páginas web de interés docente. Finalmente, la opción material docente tendrá como finalidad, crear, modificar y eliminar ficheros de diferente formato (word, excel, powerpoint, pdf) asociados a las asignaturas registradas en la aplicación. La aplicación se ha implementado en el sistema operativo Windows en el lenguaje de programación Java. Los datos utilizados se almacenan en la base de datos MySql Workbench. Para las validaciones de entrada de datos se ha utilizado JavaScript y JQuery. El diseño de la interfaz se ha llevado a cabo con Java Server Pages, Html, Css y framework Struts.