991 resultados para AC Generator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromagnetic spectrum can be identified as a resource for the designer, as well as for the manufacturer, from two complementary points of view: first, because it is a good in great demand by many different kind of applications; second, because despite its scarce availability, it may be advantageous to use more spectrum than necessary. This is the case of Spread-Spectrum Systems, those systems in which the transmitted signal is spread over a wide frequency band, much wider, in fact, than the minimum bandwidth required to transmit the information being sent. Part I of this dissertation deals with Spread-Spectrum Clock Generators (SSCG) aiming at reducing Electro Magnetic Interference (EMI) of clock signals in integrated circuits (IC) design. In particular, the modulation of the clock and the consequent spreading of its spectrum are obtained through a random modulating signal outputted by a chaotic map, i.e. a discrete-time dynamical system showing chaotic behavior. The advantages offered by this kind of modulation are highlighted. Three different prototypes of chaos-based SSCG are presented in all their aspects: design, simulation, and post-fabrication measurements. The third one, operating at a frequency equal to 3GHz, aims at being applied to Serial ATA, standard de facto for fast data transmission to and from Hard Disk Drives. The most extreme example of spread-spectrum signalling is the emerging ultra-wideband (UWB) technology, which proposes the use of large sections of the radio spectrum at low amplitudes to transmit high-bandwidth digital data. In part II of the dissertation, two UWB applications are presented, both dealing with the advantages as well as with the challenges of a wide-band system, namely: a chaos-based sequence generation method for reducing Multiple Access Interference (MAI) in Direct Sequence UWB Wireless-Sensor-Networks (WSNs), and design and simulations of a Low-Noise Amplifier (LNA) for impulse radio UWB. This latter topic was studied during a study-abroad period in collaboration with Delft University of Technology, Delft, Netherlands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the framework of developing defect-based life models, in which breakdown is explicitly associated with partial discharge (PD)-induced damage growth from a defect, ageing tests and PD measurements were carried out in the lab on polyethylene (PE) layered specimens containing artificial cavities. PD activity was monitored continuously during aging. A quasi-deterministic series of stages can be observed in the behavior of the main PD parameters (i.e. discharge repetition rate and amplitude). Phase-resolved PD patterns at various ageing stages were reproduced by numerical simulation which is based on a physical discharge model devoid of adaptive parameters. The evolution of the simulation parameters provides insight into the physical-chemical changes taking place at the dielectric/cavity interface during the aging process. PD activity shows similar time behavior under constant cavity gas volume and constant cavity gas pressure conditions, suggesting that the variation of PD parameters may not be attributed to the variation of the gas pressure. Brownish PD byproducts, consisting of oxygen containing moieties, and degradation pits were found at the dielectric/cavity interface. It is speculated that the change of PD activity is related to the composition of the cavity gas, as well as to the properties of dielectric/cavity interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project concentrates on the Low Voltage Ride Through (LVRT) capability of Doubly Fed Induction Generator (DFIG) wind turbine. The main attention in the project is, therefore, drawn to the control of the DFIG wind turbine and of its power converter and to the ability to protect itself without disconnection during grid faults. It provides also an overview on the interaction between variable speed DFIG wind turbines and the power system subjected to disturbances, such as short circuit faults. The dynamic model of DFIG wind turbine includes models for both mechanical components as well as for all electrical components, controllers and for the protection device of DFIG necessary during grid faults. The viewpoint of this project is to carry out different simulations to provide insight and understanding of the grid fault impact on both DFIG wind turbines and on the power system itself. The dynamic behavior of DFIG wind turbines during grid faults is simulated and assessed by using a transmission power system generic model developed and delivered by Transmission System Operator in the power system simulation toolbox Digsilent, Matlab/Simulink and PLECS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation presents the theory and the conducted activity that lead to the construction of a high voltage high frequency arbitrary waveform voltage generator. The generator has been specifically designed to supply power to a wide range of plasma actuators. The system has been completely designed, manufactured and tested at the Department of Electrical, Electronic and Information Engineering of the University of Bologna. The generator structure is based on the single phase cascaded H-bridge multilevel topology and is comprised of 24 elementary units that are series connected in order to form the typical staircase output voltage waveform of a multilevel converter. The total number of voltage levels that can be produced by the generator is 49. Each level is 600 V making the output peak-to-peak voltage equal to 28.8 kV. The large number of levels provides high resolution with respect to the output voltage having thus the possibility to generate arbitrary waveforms. Maximum frequency of operation is 20 kHz. A study of the relevant literature shows that this is the first time that a cascaded multilevel converter of such dimensions has been constructed. Isolation and control challenges had to be solved for the realization of the system. The biggest problem of the current technology in power supplies for plasma actuators is load matching. Resonant converters are the most used power supplies and are seriously affected by this problem. The manufactured generator completely solves this issue providing consistent voltage output independently of the connected load. This fact is very important when executing tests and during the comparison of the results because all measures should be comparable and not dependent from matching issues. The use of the multilevel converter for power supplying a plasma actuator is a real technological breakthrough that has provided and will continue to provide very significant experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive molecular-imaging technologies are playing a key role in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various deceases in vivo. However, it is limited by the availability of vectors with high selectivity to the target and radionuclides with a physical half-life which matches the biological half-life of the observed process. The 68Ge/68Ga radionuclide generator makes the PET-nuclide anywhere available without an on-site cyclotron. Besides the perfect availability 68Ga shows well suited nuclide properties for PET, but it has to be co-ordinated by a chelator to introduce it in a radiopharmaceuticals.rnHowever, the physical half-life of 68Ga (67.7 min) might limit the spectrum of clinical applications of 68Ga-labelled radiodiagnostics. Furthermore, 68Ga-labelled analogues of endoradiotherapeuticals of longer biological half-live such as 90Y- or 177Lu-labeled peptides and proteins cannot be used to determine individual radiation dosimetry directly. rnThus, radionuclide generator systems providing positron emitting daughters of extended physical half-life are of renewed interest. In this context, generator-derived positron emitters with longer physical half-life are needed, such as 72As (T½ = 26 h) from the 72Se/72As generator, or 44Sc (T½ = 3.97 h) from the 44Ti/44Sc generator.rnIn this thesis the implementation of radioactive gallium-68 and scandium-44 for molecular imaging and nuclear medical diagnosis, beginning with chemical separation and purification of 44Ti as a radionuclide mother, investigation of pilot generators with different elution mode, building a prototype generator, development and investigation of post-processing of the generator eluate, its concentration and further purification, the labeling chemistry under different conditions, in vitro and in vivo studies of labeled compounds and, finally, in vivo imaging experiments are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dal punto di vista geometrico, il tracciato delle linee AV/AC è determinato in funzione delle velocità di progetto, attualmente variabili tra 250 e 300 km/h, e in modo da limitare i parametri cinematici. In questa maniera è assicurata la corretta qualità di marcia dei treni ad alta velocità. La sovrastruttura ferroviaria è realizzata in modo da sopportare i carichi dinamici trasmessi dai convogli transitanti a elevate velocità, e da garantire la sicurezza della circolazione e il comfort di marcia. In particolare, la qualità del binario ferroviario è determinata attraverso una serie di parametri geometrici fondamentali, definiti da Rete Ferroviaria Italiana. A seconda dei valori assunti da tali parametri, il binario rientra in un livello di qualità geometrica: sono definiti tre livelli per i quali la circolazione ferroviaria avviene senza limitazioni e un livello che richiede l’imposizione di vincoli all’esercizio (rallentamenti o interruzioni). L’introduzione dei parametri geometrici e dei rispettivi valori di riferimento ha lo scopo di mantenere elevati livelli qualitativi e di sicurezza per l’infrastruttura ferroviaria, in materia di geometria dell’armamento. Infatti, il superamento di certe soglie da parte dei parametri, implica l’intervento manutentivo sul binario, al fine di ripristinare la corretta geometria e di garantire così la qualità della marcia dei treni. La politica è quella d’intervento prima del raggiungimento del quarto livello di qualità, per il quale sono necessarie restrizioni alla circolazione e interventi correttivi immediati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obbiettivo: Valutazione delle eventuali differenze nel trattamento ortodontico di un gruppo di bambini con particolari necessità sanitarie (SHCN) rispetto ad un gruppo di bambini non diagnosticati con SHCN. Materiali e Metodi: Il gruppo campione (SHCN) è costituito da 50 bambini con SHCN. Il gruppo di controllo (NO SHCN) è costituito da 50 bambini non diagnosticati con SHCN pienamente corrispondenti per età, genere e tipo di apparecchio ortodontico utilizzato con i pazienti del gruppo di studio. I dati riguardanti i gruppi SHCN e NO SHCN sono stati analizzati in modo retrospettivo, valutando: - il punteggio pre- e post-trattamento e la riduzione finale dei valori dell'indice PAR (Peer Assessment Rating), della componente DHC (Dental Health Component) e della componente AC (Aesthetic Component) dell'indice IOTN (Orthodontic Treatment Need Index), - il numero di appuntamenti, - il numero di sedute semplici e complesse, - la durata complessiva del trattamento, - l'età all’inizio ed alla fine della terapia. Risultati: Non sono state rilevate differenze statisticamente significative tra i due gruppi per quanto concerne il numero di appuntamenti, la durata complessiva del trattamento, l'età all’inizio ed alla fine della terapia ortodontica (valori del p-value:0.682, 0.458, 0.535, 0.675). Sono state rilevate differenze statisticamente significative tra i due gruppi per quanto riguarda i punteggi dell’indice PAR, delle componenti DHC e AC dello IOTN pre- e post-trattamento, il numero di sedute semplici e complesse (valori del p-value:0.030, 0.000, 0.020, 0.023, 0.000, 0.000, 0.043, 0.037). Per quanto concerne la riduzione finale del valore dell’indice PAR, della componente DHC e di quella AC dello IOTN non sono state riscontrate differenze statisticamente significative tra i due gruppi (valori del p-value:0.060, 0.765, 0.825). Conclusioni: Lo studio incoraggia gli ortodontisti a trattare i bambini con SHCN nell'obiettivo di migliorarne la qualità di vita, pur evidenziando la necessità di un maggior numero di sedute complesse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel methodology to generate realistic network flow traces to enable systematic evaluation of network monitoring systems in various traffic conditions. Our technique uses a graph-based approach to model the communication structure observed in real-world traces and to extract traffic templates. By combining extracted and user-defined traffic templates, realistic network flow traces that comprise normal traffic and customized conditions are generated in a scalable manner. A proof-of-concept implementation demonstrates the utility and simplicity of our method to produce a variety of evaluation scenarios. We show that the extraction of templates from real-world traffic leads to a manageable number of templates that still enable accurate re-creation of the original communication properties on the network flow level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved chemical strategy for processing of the generator produced 68Ga was developed based on processing of the original 68Ge/68Ga generator eluate on a micro-column. Direct pre-concentration and purification of the eluted 68Ga is performed on a cation-exchange resin in hydrochloric acid/acetone media. A supplementary step based on a second micro-column filled with a second resin allows direct re-adsorption of 68Ga eluted from the cation exchanger. 68Ga is finally striped from the second resin with a small volume of pure water. For this purpose a strong anion exchanger and a novel extraction chromatographic resin based on tetraalkyldiglycolamides are characterized. The strategy allows online pre-concentration and purification of 68Ga from the original generator eluate. The supplementary column allows transferring 68Ga with high radionuclide and chemical quality in the aqueous solution with small volume and low acidity useful for direct radiolabeling reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Jing Ltd. miniature combustion aerosol standard (Mini-CAST) soot generator is a portable, commercially available burner that is widely used for laboratory measurements of soot processes. While many studies have used the Mini-CAST to generate soot with known size, concentration, and organic carbon fraction under a single or few conditions, there has been no systematic study of the burner operation over a wide range of operating conditions. Here, we present a comprehensive characterization of the microphysical, chemical, morphological, and hygroscopic properties of Mini-CAST soot over the full range of oxidation air and mixing N-2 flow rates. Very fuel-rich and fuel-lean flame conditions are found to produce organic-dominated soot with mode diameters of 10-60nm, and the highest particle number concentrations are produced under fuel-rich conditions. The lowest organic fraction and largest diameter soot (70-130nm) occur under slightly fuel-lean conditions. Moving from fuel-rich to fuel-lean conditions also increases the O:C ratio of the soot coatings from similar to 0.05 to similar to 0.25, which causes a small fraction of the particles to act as cloud condensation nuclei near the Kelvin limit (kappa similar to 0-10(-3)). Comparison of these property ranges to those reported in the literature for aircraft and diesel engine soots indicates that the Mini-CAST soot is similar to real-world primary soot particles, which lends itself to a variety of process-based soot studies. The trends in soot properties uncovered here will guide selection of burner operating conditions to achieve optimum soot properties that are most relevant to such studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 μW) and in vivo (16.7 μW)-is sufficient to power modern pacemakers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microfluidic hydrogen generator is presented in this work. Its fabrication, characterization, and integration with a micro proton exchange membrane (PEM) fuel cell are described. Hydrogen gas is generated by the hydrolysis of aqueous ammonia borane. Gas generation, as well as the circulation of ammonia borane from a rechargeable fuel reservoir, is performed without any power consumption. To achieve this, directional growth and selective venting of hydrogen gas is maintained in the microchannels, which results in the circulation of fresh reactant from the fuel reservoir. In addition to this self-circulation mechanism, the hydrogen generator has been demonstrated to self-regulate gas generation to meet demands of a connected micro fuel cell. All of this is done without parasitic power consumption from the fuel cell. Results show its feasibility in applications of high-impedance systems. Lastly, recommendations for improvements and suggestions for future work are described