989 resultados para 359


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hearing loss is one of the most common clinical findings in subjects with malformations of the ear. Treatment consists of surgery and/or adapt a hearing aid amplification by bone (HA VO). Early intervention is critical to auditory stimulation and development of speech and language. OBJECTIVE: To characterize the audiological profile of subjects with congenital malformation of the external ear and/or middle and evaluate the benefit and satisfaction of using HA VO. METHOD: A descriptive study, subjects with bilateral congenital malformations of the external ear and/or middle, conductive or mixed hearing loss, moderate or severe and HA VO users. Evaluation of the benefit test using sentence recognition in noise and measures of functional gain and satisfaction assessment questionnaire using international IQ - HA. RESULTS: 13 subjects were evaluated, 61% were male and 80% with moderate conductive hearing loss or severe. There was better performance in the evaluation proposal, provided with HA when compared to the condition without HA. CONCLUSION: HA VO showed advantages for the population studied and should be considered as an option for intervention. Satisfaction was confirmed by elevated scores obtained in IQ - HA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maintaining the pH of urine in the ideal range (6.2 - 6.4) is of great importance for health promotion in the lower urinary tract of cats. In the economic and standard feed sector this is a major concern, given that the animal urine tends to be alkaline after food consumption of those commercial segments, which predispose to the formation of struvite urolith. Therefore, this study aimed to study the effects of increasing levels of urinary acidifiers (0.0%, 0.3%, 0.6% and 0.9%, on a dry matter base) in feed with high excess base over the acid-basic balance in the organism, apparent digestibility coefficients of nutrients, urinary pH, hydro-electrolyte balance in cats, as well as the adequacy of equations proposed in the literature to estimate the urinary pH. Twenty-four adult cats, males and females were distributed in a completely randomized design, consisting of six animals per treatment. The dry matter content of urine presented a quadratic behavior (p<0,05; y = 9.5863 + 3.2299x + 0.7871x2 R2 = 99,91%), HCO3-, total CO2 and excess blood base during the period in which the animals were fed were high when including 0.9% acidifier compared to 0.6% (p<0.05). In contrast, the use of the additive did not change the urinary pH, blood electrolyte concentration, nutrient digestibility, fecal score, food and water intake (p>0.05). The equations proposed in the literature, which use excess of base in feed to estimate urinary pH, overestimated the pH values found in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Foram avaliados e comparados os eixos mecânicos pós-operatórios de 36 artroplastias totais de joelho pelos sistemas de alinhamento navegado e mecânico feitos no mesmo período pelo mesmo cirurgião e equipe, iniciantes na técnica navegada e com experiência na técnica mecânica. MÉTODOS: Entre 2008 e 2010, 36 próteses totais de joelho foram executadas e comparadas, 25 navegadas e 11 mecânicas. Qualquer desvio de eixo medido no RX panorâmico pós-operatório foi considerado positivo. RESULTADOS: As próteses navegadas obtiveram média de desvio de eixo de 1,32 graus e desvio padrão de 1,57 graus e as mecânicas, respectivamente, 3,18 e 2,99 graus. Houve um melhor alinhamento com tendência à diferença estatística em favor da técnica navegada. CONCLUSÃO: Os casos com desvio de eixo maior que três graus foram significativamente maiores na técnica mecânica. A técnica por navegação foi incorporada por nossa equipe sem complicações adicionais e, mesmo sem experiência em cirurgia navegada, os primeiros casos obtiveram melhor alinhamento em relação à técnica mecânica e número significativamente menor de casos fora da zona de segurança de três graus em relação ao eixo mecânico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O intuito do presente artigo é analisar os resultados de uma pesquisa conduzida junto a alunos de dois cursos de alemão como língua estrangeira. A investigação se insere no marco teórico dos estudos sobre crenças. Pretende-se pôr em relevo a percepção do alunado a respeito do conteúdo programático das aulas que frequenta - e, sobretudo, os valores e pesos que deposita sobre cada elemento que integra uma aula de língua estrangeira: de um lado, que importância dedica às atividades de desenvolvimento das "quatro habilidades" (ler, escrever, falar e ouvir), ao trabalho com a gramática, com o léxico e com aspectos inter e transculturais.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper emphasizes the influence of micro mechanisms of failure of a cellular material on its phenomenological response. Most of the applications of cellular materials comprise a compression loading. Thus, the study focuses on the influence of the anisotropy in the mechanical behavior of cellular material under cyclic compression loadings. For this study, a Digital Image Correlation (DIC) technique (named Correli) was applied, as well as SEM (Scanning Electron Microscopy) images were analyzed. The experimental results are discussed in detail for a closed-cell rigid poly (vinyl chloride) (PVC) foam, showing stress-strain curves in different directions and why the material can be assumed as transversely isotropic. Besides, the present paper shows elastic and plastic Poisson's ratios measured in different planes, explaining why the plastic Poisson's ratios approach to zero. Yield fronts created by the compression loadings in different directions and the influence of spring-back phenomenon on hardening curves are commented, also.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to study the leaf temperature (LT) and leaf diffusive vapor conductance (gs) responses to temperature, humidity and incident flux density of photosynthetically active photons (PPFD) of tomato plants grown without water restriction in a plastic greenhouse in Santa Maria, RS, Brazil. The plants were grown in substrate and irrigated daily. The gs was measured using a steady-state null-balance porometer on the abaxial face of the leaves during the daytime. Both leaf surfaces were measured in one day. The PPFD and LT were measured using the porometer. Leaf temperature was determined using an infrared thermometer, and air temperature and humidity were measured using a thermohygrograph. The leaves on the upper layer of the plants had higher gs than the lower layer. The relationship between the gs and PPFD was different for the two layers in the plants. A consistent relationship between the gs and atmospheric water demand was observed only in the lower layer. The LT tended to be lower than the air temperature. The mean value for the gs was 2.88 times higher on the abaxial than adaxial leaf surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare aerobic function [anaerobic threshold (%_VVO2-AT), respiratory compensation point (%_VVO2-RCP) and peak oxygen uptake (_VVO2peak)] between physically active patients with HIV/AIDS and matched controls and to examine associations between disease status, poor muscle strength, depression (as estimated by the profile of mood states questionnaire) and the aerobic performance of patients. METHODS: Progressive treadmill test data for %_VVO2-AT (V-slope method), RCP and (_VVO2peak) were compared between 39 male patients with HIV/AIDS (age 40.6¡1.4 years) and 28 male controls (age 44.4¡2.1 years) drawn from the same community and matched for habitual physical activity. Within-patient data were also examined in relation to CD4+ counts (nadir and current data) and peak isokinetic knee torque. RESULTS: AT, RCP and (_VVO2peak) values were generally similar for patients and controls.Within the patient sample, binary classification suggested that AT, RCP and (_VVO2peak) values were not associated with either the nadir or current CD4+ count, but treadmill test variables were positively associated with peak isokinetic knee torque. CONCLUSION: The aerobic performance of physically active patients with HIV/AIDS is generally well conserved. Nevertheless, poor muscle strength is observed in some HIV/AIDS patients, which is associated with lower anaerobic power and (_VVO2peak), suggesting the possibility of enhancing the aerobic performance of patients with weak muscles through appropriate muscle-strengthening activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a imunogenicidade e segurança da vacina contra hepatite B, após o aumento na concentração do antígeno HBsAg para 25 μg, em comparação à vacina de referência. MÉTODOS: Ensaio com alocação aleatória e mascaramento simples, comparando a VrHB-IB (Instituto Butantan) com a vacina de referência (Engerix B®, Glaxo Smith Kline). Os voluntários, entre 31 e 40 anos de idade (n=419), foram alocados aleatoriamente ao grupo experimental (n=216) ou ao grupo controle (n=203), e receberam três doses de vacina. A primeira dose foi administrada no momento do recrutamento, a segunda e terceira 30 e 180 dias depois respectivamente, entre 2004 e 2005. Amostras de sangue foram colhidas para análise sorológica antes da randomização, e após a segunda e terceira doses. Foi realizada a vigilância ativa de eventos adversos durante os cinco primeiros dias após a vacinação. As diferenças foram avaliadas pelos testes do qui-quadrado e exato de Fisher, com nível de significância de 5%. RESULTADOS: Não se observaram eventos adversos graves. A soroporteção foi confirmada em 98,6% (213/216) dos voluntários do grupo experimental, em comparação a 95,6% (194/203) do grupo controle. Os títulos geométricos médios foram de 12.557 e 11.673, respectivamente. CONCLUSÕES: A vacina brasileira foi considerada equivalente à vacina de referência e seu uso recomendado para adultos.