937 resultados para 091301 Acoustics and Noise Control (excl. Architectural Acoustics)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a comprehensive comparison of a current-source converter and a voltage-source converter for three-phase electric vehicle (EV) fast battery chargers. Taking into account that the current-source converter (CSC) is a natural buck-type converter, the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. On the other hand, taking into account that the voltage-source converter (VSC) is a natural boost-type converter, the output voltage is always greater than the maximum instantaneous value of the power grid phase-to-phase voltage, and consequently, it is necessary to use a dc-dc buck-type converter for applications as EV fast battery chargers. Along the paper is described in detail the principle of operation of both the CSC and the VSC for EV fast chargers, as well as the main equations of the power theory and current control strategies. The comparison between both converters is mainly established in terms of the total harmonic distortion of the grid current and the estimated efficiency for a range of operation between 10 kW and 50 kW.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a multifunctional converter to interface renewable energy sources (e.g., solar photovoltaic panels) and electric vehicles (EVs) with the power grid in smart grids context. This multifunctional converter allows deliver energy from the solar photovoltaic panels to an EV or to the power grid, and exchange energy in bidirectional mode between the EV and the power grid. Using this multifunctional converter are not required multiple conversion stages, as occurs with the traditional solutions, where are necessary two power converters to integrate the solar photovoltaic system in the power grid and also two power converters to integrate an off-board EV battery charger in the power grid (dc-dc and dc-ac power converters in both cases). Taking into account that the energy provided (or delivered) from the power grid in each moment is function of the EV operation mode and also of the energy produced from the solar photovoltaic system, it is possible to define operation strategies and control algorithms in order to increase the energy efficiency of the global system and to improve the power quality of the electrical system. The proposed multifunctional converter allows the operation in four distinct cases: (a) Transfer of energy from the solar photovoltaic system to the power grid; (b) Transfer of energy from the solar photovoltaic system and from the EV to the power grid; (c) Transfer of energy from the solar photovoltaic system to the EV or to the power grid; (d) Transfer of energy between the EV and the power grid. Along the paper are described the system architecture and the control algorithms, and are also presented some computational simulation results for the four aforementioned cases. It is also presented a comparative analysis between the traditional and the proposed solution in terms of operation efficiency and estimated cost of implementation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solar photovoltaic systems are an increasing option for electricity production, since they produce electrical energy from a clean renewable energy resource, and over the years, as a result of the research, their efficiency has been increasing. For the interface between the dc photovoltaic solar array and the ac electrical grid is necessary the use of an inverter (dc-ac converter), which should be optimized to extract the maximum power from the photovoltaic solar array. In this paper is presented a solution based on a current-source inverter (CSI) using continuous control set model predictive control (CCS-MPC). All the power circuits and respective control systems are described in detail along the paper and were tested and validated performing computer simulations. The paper shows the simulation results and are drawn several conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the development of na on-board bidirectional battery charger for Electric Vehicles (EVs) targeting Grid-to-Vehicle (G2V), Vehicle-to-Grid (V2G), and Vehicle-to-Home (V2H) technologies. During the G2V operation mode the batteries are charged from the power grid with sinusoidal current and unitary power factor. During the V2G operation mode the energy stored in the batteries can be delivered back to the power grid contributing to the power system stability. In the V2H operation mode the energy stored in the batteries can be used to supply home loads during power outages, or to supply loads in places without connection to the power grid. Along the paper the hardware topology of the bidirectional battery charger is presented and the control algorithms are explained. Some considerations about the sizing of the AC side passive filter are taken into account in order to improve the performance in the three operation modes. The adopted topology and control algorithms are accessed through computer simulations and validated by experimental results achieved with a developed laboratory prototype operating in the different scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the major challenges in the development of an immersive system is handling the delay between the tracking of the user’s head position and the updated projection of a 3D image or auralised sound, also called end-to-end delay. Excessive end-to-end delay can result in the general decrement of the “feeling of presence”, the occurrence of motion sickness and poor performance in perception-action tasks. These latencies must be known in order to provide insights on the technological (hardware/software optimization) or psychophysical (recalibration sessions) strategies to deal with them. Our goal was to develop a new measurement method of end-to-end delay that is both precise and easily replicated. We used a Head and Torso simulator (HATS) as an auditory signal sensor, a fast response photo-sensor to detect a visual stimulus response from a Motion Capture System, and a voltage input trigger as real-time event. The HATS was mounted in a turntable which allowed us to precisely change the 3D sound relative to the head position. When the virtual sound source was at 90º azimuth, the correspondent HRTF would set all the intensity values to zero, at the same time a trigger would register the real-time event of turning the HATS 90º azimuth. Furthermore, with the HATS turned 90º to the left, the motion capture marker visualization would fell exactly in the photo-sensor receptor. This method allowed us to precisely measure the delay from tracking to displaying. Moreover, our results show that the method of tracking, its tracking frequency, and the rendering of the sound reflections are the main predictors of end-to-end delay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Arquitectura

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the effects of in-hospital reocclusion of reperfused AMI culprit coronary arteries in mortality and to identify the predictors. METHODS: The present study comprises a sample of 155 patients with AMI who underwent successful mechanical reperfusion by direct coronary angioplasty and angiographic control during hospitalization or before discharge. Patients were classified into group A: reoccluded patients (n=30) and group B: non-reoccluded patients (n=125). RESULTS: We identified in-hospital reocclusion predictors and found a greater significance in mortality among reoccluded patients (23,3% x 1.6%; p=0.00004). Silent reocclusion or typical angina at reocclusion had a good prognosis. The independent predictors of in-hospital mortality were hypertension, multiarterial lesions, totally occluded AMI culprit lesions, failed redilatation, failed redilatation in comparison with no intention to redilate, no redilatation in comparison with no atempt to redilate, and reocclusion within the first 48 to 72 hours. The decision to redilate, independently of the result, led to a 50.0% reduction in hospital mortality (p=0.0366). CONCLUSION: In-hospital AMI culprit coronary artery reocclusion had an adverse effect similar to that reported in clinical studies with high mortality rates (23.3% x 1.6%; p=0.00004). The major contribution of this study is to recommend the reopening of reoccluded AMI culprit coronary arteries as a means for the management of coronary artery reocclusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Series Title: IFIP - The International Federation for Information Processing, ISSN 1868-4238"

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate cardiac arrhythmias during and after pregnancy in women with Chagas' disease without apparent heart disease using dynamic electrocardiography. METHODS: Twenty pregnant women with Chagas' disease without apparent heart disease aged 19 to 42 years (26.96 ± 3.6) and a control group of 20 non-chagasic pregnant patients aged 16 to 34 years (22.5 ± 4.8). The patients were submitted to passive hemagglutination and indirect immunofluorescence for the detection of Trypanosoma cruzi evaluation, and electrocardiography, echocardiography and 24-h dynamic electrocardiography. RESULTS: Supraventricular premature depolarizations were observed in 18 (90%) patients and ventricular premature depolarization in 11 (55%) patients of both groups during pregnancy. After delivery, supraventricular premature depolarizations were present in 13 (60%) chagasic patients and in 16 (89.4%) control patients (P<=0.05). Ventricular premature depolarization were observed in 9 (45%) chagasic patients and 11 (57.8%) control patients. CONCLUSION: The prevalence of ventricular premature depolarization was similar for the chagasic and control groups during and after pregnancy. The incidence of supraventricular premature depolarizations was similar in the two groups during pregnancy, while after delivery a predominance was observed in the control group compared to the chagasic group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biofilm adhesion to metals (copper, aluminium and brass) was studied at two different velocities and pH values of 7 and 9. Both bacteria and metals showed negative surface charges at those values of pH, which tends to slow down adhesion. Film densities increased with the fluid velocity and were also affected by the pH and by the growth rate of the bacteria. Long duration tests based on heat transfer measurements were run at five different fluid velocities and at pH = 7, showing in general an asymptotic behaviour and a control of deposition by adhesion and growth phenomena.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Lupus anticoagulant and anticardiolipin antibodies (aCL) have been associated with thrombosis, recurrent abortion, and thrombocytopenia in patients with systemic lupus erythematosus (SLE), but their relationship with cardiac disease is less clear. The purpose of this study was to evaluate the association between antiphospholipid antibodies (aPL) and echocardiographic abnormalities in patients with SLE. METHODS: A total of 70 consecutive patients and 42 control subjects underwent M-mode, 2-dimensional and Doppler echocardiography and tests for lupus anticoagulant, aCL IgG, IgM, and IgA. Lupus anticoagulant was assayed with the dilute Russell viper venom time, and aCL IgG, IgM, and IgA were measured by an enzyme-linked immunosorbent assay (ELISA). RESULTS: Lupus anticoagulant showed a prevalence of 10%. As a whole, aCL had a prevalence of 44.3% and aPL had a prevalence of 50%. Patients with echocardiographic abnormalities had a prevalence of 54.3% and showed a trend towards an association with aCL IgG (P=0.06). The presence of pulmonary hypertension (PH) was significantly associated with aCL IgG (p=0.02). CONCLUSION: aCL IgG was significantly associated with PH and showed a strong trend towards an association with echocardiographic abnormalities taken together. These findings suggest a role for aCL IgG in the development of lupus cardiovascular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the main operation modes for an electric vehicle (EV) battery charger framed in smart grids and smart homes, i.e., are discussed the present-day and are proposed new operation modes that can represent an asset towards EV adoption. Besides the well-known grid to vehicle (G2V) and vehicle to grid (V2G), this paper proposes two new operation modes: Home-to-vehicle (H2V), where the EV battery charger current is controlled according to the current consumption of the electrical appliances of the home (this operation mode is combined with the G2V and V2G); Vehicle-for-grid (V4G), where the EV battery charger is used for compensating current harmonics or reactive power, simultaneously with the G2V and V2G operation modes. The vehicle-to-home (V2H) operation mode, where the EV can operate as a power source in isolated systems or as an off-line uninterruptible power supply to feed priority appliances of the home during power outages of the electrical grid is presented in this paper framed with the other operation modes. These five operation modes were validated through experimental results using a developed 3.6 kW bidirectional EV battery charger prototype, which was specially designed for these operation modes. The paper describes the developed EV battery charger prototype, detailing the power theory and the voltage and current control strategies used in the control system. The paper presents experimental results for the various operation modes, both in steady-state and during transients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether the intima-media thickness of the common carotid artery of patients with coronary artery disease is greater than that of individuals without that disease. METHODS: Case-control prospective study of prevalence assessing the thickness of the intima and media layers of 29 patients with coronary artery disease and 29 individuals without that disease by using ultrasonography of the carotid arteries. Diabetic patients and those with peripheral artery and cerebral vasculopathies were excluded from the study. RESULTS: The mean age was 51±7.5 years. Fifty-five per cent of the patients were males. Acute myocardial infarction was present in 62%; cardiac catheterization in 72%; saphenous bypass in 5%; and coronary angioplasty in 24%. The intima-media thickness of the common carotid artery in case patients and in control patients was, respectively, 0.81±0.25 mm and 0.62±0.18 mm (P=0.001). CONCLUSION: Intima-media thickness of the common carotid artery was significantly greater in patients with coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La producción de leche de cabra es considerada en nuestro país, y en la provincia de Córdoba, una alternativa productiva para el desarrollo sustentable y socio – económico de la población. Por otra parte, existe una mayor demanda del mercado nacional e internacional de esta leche, por lo que los productores deben garantizar la seguridad y calidad de la misma de acuerdo a las normas vigentes. Es por ello que el control y tratamiento de las diferentes enfermedades es de vital importancia tanto para maximizar la producción del hato como para cumplir con los cánones de seguridad exigidos. En este contexto la mastitis caprina es una de las enfermedades que afecta la productividad del sector, y para controlarla una de las medidas a emplear es la terapéutica con antimicrobianos. Se trabajará en este proyecto con marbofloxacina y cefquinoma, estableciendo pautas racionales (eficaces y seguras) para su empleo en la afección a nivel regional. Los indicadores de eficacia estarán fijados de acuerdo a los parámetros integrados de farmacocinética (FC) y farmacodinamia (FD). Estos últimos (FD) serán calculados a través de la determinación concentraciones inhibitorias mínimas de cepas bacterianas aisladas de mastitis caprinas en Córdoba. Se establecerán los parámetros farmacocinéticos a dosis únicas y múltiples para la marbofloxacina (5 mg/kg IV, IM) y cefquinoma (2 mg/kg IV, IM e IMM) a partir de muestras de suero y leche de cabras Anglo Nubian (n = 6 por antimicrobiano; diseño cruzado en función de la ruta de administración). Se determinarán sus concentraciones en dichos fluidos, por cromatografía líquida de alta precisión. Los resultados FC/FD para ambos medicamentos se compararán con parámetros recomendados por expertos para cada tipo de antimicrobiano y se utilizarán como medida para recomendar una terapéutica racional, fundamental para optimizar la posología, garantizar la eficacia clínica, y reducir al mínimo la selección y propagación de cepas resistentes de agentes patógenos. The production of milk of goat is considered the province of Cordoba, a productive alternative for the sustainable development and partner - economically of the population. There is a major demand of the domestic and international market of this milk, for what the producers must guarantee the safety and quality of the same one of agreement to the in force procedure. It is for it that the control and treatment of the different diseases performs vital importance so much to maximize the production of the herd as to expire with the safety demanded. In this context the mastitis goat is one of the diseases that affect the productivity of the sector, and to control her one of the measures to using is the therapeutics with antimicrobial. One will be employed at this project with marbofloxacine and cefquinome, establishing rational guidelines (effective and sure) for his employment in the affection to regional level. The indicators of efficiency will be fixed in agreement to the integrated parameters of pharmacokinetics (PK) and pharmacodinamics (PD). The latter (PK) will be calculated across the determination inhibitory minimal concentrations of bacterial strains isolated of mastitis goat in Córdoba. The parameters will be established pharmacokinetics to the only and multiple doses for the marbofloxacine (5 mg/kg the IV, IM) and cefquinome (2 mg/kg the IVth, IM and IMM), From samples of whey and milk of goats Anglo Nubian (n = 6 for antimicrobial; design crossed depending on the route of administration). Its concentrations will decide in the above mentioned fluids, for liquid chromatography of high precision. The results PK/PD for both antimicrobial will be compared with parameters recommended by experts for every type of antimicrobial and will be in use as measure for recommending a rational, fundamental therapeutics for optimizing the dosage, for guaranteeing the clinical efficiency, and to reduce to the minimum the selection and spread of resistant of pathogenic agents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chemical structure of lipoprotein (a) is similar to that of LDL, from which it differs due to the presence of apolipoprotein (a) bound to apo B100 via one disulfide bridge. Lipoprotein (a) is synthesized in the liver and its plasma concentration, which can be determined by use of monoclonal antibody-based methods, ranges from < 1 mg to > 1,000 mg/dL. Lipoprotein (a) levels over 20-30 mg/dL are associated with a two-fold risk of developing coronary artery disease. Usually, black subjects have higher lipoprotein (a) levels that, differently from Caucasians and Orientals, are not related to coronary artery disease. However, the risk of black subjects must be considered. Sex and age have little influence on lipoprotein (a) levels. Lipoprotein (a) homology with plasminogen might lead to interference with the fibrinolytic cascade, accounting for an atherogenic mechanism of that lipoprotein. Nevertheless, direct deposition of lipoprotein (a) on arterial wall is also a possible mechanism, lipoprotein (a) being more prone to oxidation than LDL. Most prospective studies have confirmed lipoprotein (a) as a predisposing factor to atherosclerosis. Statin treatment does not lower lipoprotein (a) levels, differently from niacin and ezetimibe, which tend to reduce lipoprotein (a), although confirmation of ezetimibe effects is pending. The reduction in lipoprotein (a) concentrations has not been demonstrated to reduce the risk for coronary artery disease. Whenever higher lipoprotein (a) concentrations are found, and in the absence of more effective and well-tolerated drugs, a more strict and vigorous control of the other coronary artery disease risk factors should be sought.