978 resultados para virtual models
Resumo:
Due to its ability to represent intricate systems with material nonlinearities as well as irregular loading, boundary, geometrical and material domains, the finite element (FE) method has been recognized as an important computational tool in spinal biomechanics. Current FE models generally account for a single distinct spinal geometry with one set of material properties despite inherently large inter-subject variability. The uncertainty and high variability in tissue material properties, geometry, loading and boundary conditions has cast doubt on the reliability of their predictions and comparability with reported in vitro and in vivo values. A multicenter study was undertaken to compare the results of eight well-established models of the lumbar spine that have been developed, validated and applied for many years. Models were subjected to pure and combined loading modes and their predictions were compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges; their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with previously published median in vitro values. However, the ranges of predictions were larger and exceeded the in vitro ranges, especially for facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with in vivo values. The simulations yielded median facet joint forces of 0 N in flexion, 38 N in extension, 14 N in lateral bending and 60 N in axial rotation that could not be validated due to the paucity of in vivo facet joint forces. In light of high inter-subject variability, one must be cautious when generalizing predictions obtained from one deterministic model. This study demonstrates however that the predictive power increases when FE models are combined together. The median of individual numerical results can hence be used as an improved tool in order to estimate the response of the lumbar spine.
Resumo:
Red blood cells (RBCs) are nonnucleated liquid capsules, enclosed in deformable viscoelastic membranes with complex three dimensional geometrical structures. Generally, RBC membranes are highly incompressible and resistant to areal changes. However, RBC membranes show a planar shear deformation and out of plane bending deformation. The behaviour of RBCs in blood vessels is investigated using numerical models. All the characteristics of RBC membranes should be addressed to develop a more accurate and stable model. This article presents an effective methodology to model the three dimensional geometry of the RBC membrane with the aid of commercial software COMSOL Multiphysics 4.2a and Fortran programming. Initially, a mesh is generated for a sphere using the COMSOL Multiphysics software to represent the RBC membrane. The elastic energy of the membrane is considered to determine a stable membrane shape. Then, the actual biconcave shape of the membrane is obtained based on the principle of virtual work, when the total energy is minimised. The geometry of the RBC membrane could be used with meshfree particle methods to simulate motion and deformation of RBCs in micro-capillaries
Resumo:
A mentor’s feedback can present professional insights to allow a mentee to reflect and develop practice. This paper positions two models for feedback that have emanated from empirical studies. It also demonstrates the diverse viewpoints of mentors and suggests strategies for providing quality feedback. In one qualitative study, 24 mentors observed a final-year preservice teacher through a professionally video-recorded lesson and wrote their observations towards giving feedback to the potential mentee. Tables illustrated in the paper, show that mentors’ positive feedback and constructive criticisms vary considerably on the same observed events. Data from this study were synthesised to posit a theoretical model for analysing mentor feedback in an interconnected, three-way Venn diagram, namely: visual, auditory and conceptual frames. Another study (n=28), which is a collection of mentor teachers’ work samples during the Mentoring for Effective Teaching (MET) program, provides strategies within six feedback practices, that is: (1) negotiated mentor-mentee expectations for providing feedback on practices, (2) reviewing teaching plans, (3) arranging for observations of practices, (4) providing oral feedback, (5) providing written feedback, and; (6) presenting opportunities for the mentee to evaluate teaching practices with consideration of the mentor’s feedback. For example, on the last mentioned practice (6) there were strategies such as “Plan a time for evaluation of practices (guided reflection)”, “Read the mentee’s reflection on practice and discuss how it aligns with your observations of their practices”, and “Highlight verbally and/or in writing where the mentee is perceptive about the reflection and how the reflection could be enhanced for future evaluations”. Developing a range of strategies that may assist the mentee in professional growth, include enlisting a community of mentors, ensuring mentors have a repertoire of strategies for articulating feedback, and using mentor feedback tools and models. This study has implications for the development of feedback models and strategies.
Resumo:
Using established strategic management and business model frameworks we map the evolution of universities in the context of their value proposition to students as consumers of their products. We argue that in the main universities over time have transitioned from a value-based business model through to an efficiency-based business model that for numerous reasons, is becoming rapidly unsustainable. We further argue that the future university business models would benefit with a reconfiguration towards a network value based model. This approach requires a revised set of perceived benefits, better aligned to the current and future expectations and an alternate approach to the delivery of those benefits to learner / consumers.
Resumo:
Protein molecular motors are natural nano-machines that convert the chemical energy from the hydrolysis of adenosine triphosphate into mechanical work. These efficient machines are central to many biological processes, including cellular motion, muscle contraction and cell division. The remarkable energetic efficiency of the protein molecular motors coupled with their nano-scale has prompted an increasing number of studies focusing on their integration in hybrid micro- and nanodevices, in particular using linear molecular motors. The translation of these tentative devices into technologically and economically feasible ones requires an engineering, design-orientated approach based on a structured formalism, preferably mathematical. This contribution reviews the present state of the art in the modelling of protein linear molecular motors, as relevant to the future design-orientated development of hybrid dynamic nanodevices. © 2009 The Royal Society of Chemistry.
Resumo:
Purpose: To determine the extent to which the accuracy of magnetic resonance imaging (MRI) based virtual 3-dimensional (3D) models of the intact orbit can approach that of the gold standard, computed tomography (CT) based models. The goal was to determine whether MRI is a viable alternative to CT scans in patients with isolated orbital fractures and penetrating eye injuries, pediatric patients, and patients requiring multiple scans in whom radiation exposure is ideally limited. Materials and Methods: Patients who presented with unilateral orbital fractures to the Royal Brisbane and Women’s Hospital from March 2011 to March 2012 were recruited to participate in this cross-sectional study. The primary predictor variable was the imaging technique (MRI vs CT). The outcome measurements were orbital volume (primary outcome) and geometric intraorbital surface deviations (secondary outcome)between the MRI- and CT-based 3D models. Results: Eleven subjects (9 male) were enrolled. The patients’ mean age was 30 years. On average, the MRI models underestimated the orbital volume of the CT models by 0.50 0.19 cm3 . The average intraorbital surface deviation between the MRI and CT models was 0.34 0.32 mm, with 78 2.7% of the surface within a tolerance of 0.5 mm. Conclusions: The volumetric differences of the MRI models are comparable to reported results from CT models. The intraorbital MRI surface deviations are smaller than the accepted tolerance for orbital surgical reconstructions. Therefore, the authors believe that MRI is an accurate radiation-free alternative to CT for the primary imaging and 3D reconstruction of the bony orbit. �