915 resultados para tangential vibration
Resumo:
Grinding is a precision machining process which is widely used in the manufacture of components requiring fine tolerances and smooth surfaces. There are several imput parameters (cutting conditions, cutting fluid and grinding wheel type used, dressing conditions etc.) which can affect the process variables (tangential and normal cutting forces, roughness, grinding temperatures, G ratio, etc.) leading to differences in the roughness, in the surface integrity and in the mechanical strength of the ground component. Consequently, the imput parameters must be controlled in order to insure the workpiece final quality. This paper presents a comparative evaluation of the performance of two types of grinding wheels [a conventional (Al2O3) and a superabrasive (CBN)] when grinding a VC131 steel, by the analysis of specific process variables when varying the cutting conditions. Highest values of G ratio and lowest workpiece roughness was observed when using CBN grinding wheels. This confirms the global trend of replacement of alumina grinding wheels by CBN, when grinding DTG (difficult to grind) materials.
Resumo:
Contracted GTF basis sets designed with aid of the Generator Coordinate Hartree-Fock (GCHF) method for H(2S), O2-(1S), and Cr3+(4F) atomic species are applied to perform theoretical interpretation of the Raman spectrum of hexaaquachromium(III) ion. The 16s, 16s 10p, and 24s17p13d GTF basis sets were contracted to [4s] for H atom, [6s4p], and [9s6p3d] for O2- and Cr3+, respectively, by Dunning's scheme. For Cr3+, the [9s6p3d] basis set was enriched with f polarization function and used in combination com [4s] and [6s4p] in the study of our interest. The results obtained in this report show that the contracted GTF basis sets used are a useful alternative for the theoretical interpretation of Raman spectrum of hexaaquachromium(III) ion and that GCHF method is an effective alternative to selection of GTF basis sets for theoretical study of vibrational properties of poliatomic species. © 2003 Elsevier Science B.V. All rights reserved.
Resumo:
This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.
Resumo:
This paper had the objective of studying variability of radial, tangential, longitudinal and volumetric shrinkage between the juvenile and mature wood, from a 35 year-old Pinus taeda L., from Horto Florestal of Manduri at São Paulo State, Brazil. First of all the experimental program determinations were related to the juvenile wood, region of the transition and region of the mature wood, using anatomical analysis (length of the axial tracheids), according to ABNT and IAWA codes. Results had shown that the area of juvenile wood of this species occurs approximately until the 20th growth ring, being more representative until the 12th ring. The transition area of this wood occurs between the 12th and 20th growth ring. In the second part of the work the shrinkage of the juvenile and mature wood were evaluated. Values of the radial, tangential and volumetric shrinkage were smaller and more variable on the juvenile wood. The longitudinal shrinkage did not present significant differences between the two wood types; medium values were slightly inferior and very variable on juvenile wood related to mature wood.
Resumo:
It had been studied the dimensional variations Pinus caribæa var. hondurensis and Eucalyptus grandiswood, emphasizing the axial, radial, tangential and volumetric shrinkage. The results had shown that the volumetric shrinkage of Pinus and Eucalyptus varied according to an exponential curve, R V=R Vmaxe -ku. The total or maximum volumetric shrinkage showed a linear behavior with the specific gravity on basis of ovendry mass and volume and the same behavior as respect of the specific gravity, where the adjusted equations were, respectively: R vmax = 3,01 + 19,15,oo e R vmax = 1,96 + 24,28,ob. It was also verified that the tangential shrinkage was 1,3 times greater than the radial one and 9,0 times greater than the axial one.
Resumo:
The aim of the present work was to carry out experimental comparison between humic substances (HS) and representative α-amino acids (methionine, methionine sulfoxide and cysteine hydrochloride) in relation to the complexation of biologically active trace elements (Al, Cu, Pb, Mn, Zn, Cd and Ni). A mobile time-controlled tangential-flow UF technique was applied to differentiate between HS-metal and α-aminoacids-metal complexes. Metal determinations were conventionally carried out using a ICP-OES. The results showed that HS may be considered as a selective complexing agents with higher metal bonding capability in relation to Al, Cu and Pb, the fact that may be clinically important.
Resumo:
One of the great challenges of structural dynamics is to ally structures lighther and stronger. The great difficulty is that light systems, in general, have a low inherent damping. Besides, they contain resonance frequencies in the low frequency range. So, any external disturbance can excite the system in some resonance and the resulting effect can be drastic. The methodologies of active damping, with control algorithms and piezoelectric sensors and actuators coupled in a base structure, are attractive in current days, in order to overcome the contradictory features of these requeriments. In this sense, this article contributes with a bibliographical review of the literature on the importance of active noise and vibration control in engineering applications, models of smart structures, techniques of optimal placement of piezoelectric sensors and actuators and methodologies of structural active control. Finally, it is discussed the future perspectives in this area.
Resumo:
The behavior of the minimum quantity lubricant (MQL) technique was analyzed under different lubricating and cooling conditions when grinding ABNT 4340 steel. The comparative analysis of the residual stress values showed that residual compressive stresses were obtained under all the lubrication/cooling conditions and types of abrasive tools employed. The highest residual compressive stress obtained with the aluminum oxide grinding wheel with MQL under the condition of V= 30m/s for air and V= 40ml/h for lubricant was -376MPa against the -160MPa attained with conventional cooling, representing a 135% increase in residual compressive stress. The results show that method and quantity of lubricant and cooling are factors that influence the grinding process.
Resumo:
Successful experiments in nonlinear vibrations have been carried out with cantilever beams under harmonic base excitation. A flexible slender cantilever has been chosen as a convenient structure to exhibit modal interactions, subharmonic, superharmonic and chaotic motions, and others interesting nonlinear phenomena. The tools employed to analyze the dynamics of the beam generally include frequency- and force-response curves. To produce force-response curves, one keeps the excitation frequency constant and slowly varies the excitation amplitude, on the other hand, to produce frequency-response curves, one keeps the excitation amplitude fixed and slowly varies the excitation frequency. However, keeping the excitation amplitude constant while varying the excitation frequency is a difficult task with an open-loop measurement system. In this paper, it is proposed a closed-loop monitor vibration system available with the electromagnetic shaker in order to keep the harmonic base excitation amplitude constant. This experimental setup constitutes a significant improvement to produce frequency-response curves and the advantages of this setup are evaluated in a case study. The beam is excited with a periodic base motion transverse to the axis of the beam near the third natural frequency. Modal interactions and two-period quasi-periodic motion are observed involving the first and the third modes. Frequency-response curves, phase space and Poincaré map are used to characterize the dynamics of the beam.
Resumo:
A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.
Resumo:
In this work, the dynamic behavior of self-synchronization and synchronization through mechanical interactions between the nonlinear self-excited oscillating system and two non-ideal sources are examined by numerical simulations. The physical model of the system vibrating consists of a non-linear spring of Duffing type and a nonlinear damping described by Rayleigh's term. This system is additional forced by two unbalanced identical direct current motors with limited power (non-ideal excitations). The present work mathematically implements the parametric excitation described by two periodically changing stiffness of Mathieu type that are switched on/off. Copyright © 2005 by ASME.
Resumo:
'Profusion Cherry' is a dwarf zinnia with prospect for pot use in Brazil. The success of flowering potted plants depends on its performance during transport and on the period of time that it performs well indoors. Benzyladenine application may retard leaf and flower senescence, increasing postproduction longevity and quality. Senescent flowers removal by consumers, to give a fresh appearance to home flowering potted plant, could influence source-sink relationship and postproduction. This study evaluated the effect of benzyladenine and senescent flowers removal on postproduction performance of 'Profusion Cherry', and observed the senescence symptoms. When plants, produced in greenhouse at São Paulo State, Brazil, had 4 to 5 open flowers, they were sprayed to runoff a single time (20ml/pot) with benzyladenine (0.4, 0.6, 0.8 or 1.0 mmol) and placed into plastic trays, without sleeve. The experimental design was a randomized blocks with 6 treatments (control, four benzyladenine concentrations and senescent flowers removal), 4 replications (2 pots per experimental unit), totalising 12 potted plants in each plastic tray (block). To simulate highway transport, plants remained for 4 days in a dark chamber, at 20.0 °C without irrigation. To include vibration, each plastic tray, was placed in an incubator shaker for 3hr a day, at 60 rpm, 25°C and darkness. After simulated transport, plants remained indoors (10h.day-1 with 18 μmol.m-2.s-1 PPF, 21.5 to 27.0°C and, 14 h.day-1 at darkness, 18.5 to 24.0°C) during 21 days. Plants performed well during simulated transport, and also indoors for two weeks. For most of evaluated parameters there was not significant effect of benzyladenine concentrations by Tukey's test. Senescent flowers removal did not delayed senescence or improved plants quality. The symptoms associated with the loss of decorative life were ray florets color fading and wilting, without abscission of flowers or petals.
Resumo:
A finite element modeling of an intelligent truss structure with piezoelectric stack actuators for the purpose of active damping and structural vibration attenuation is presented. This paper concerns with the following issues aspects: the design of intelligent truss structure considering electro-mechanical coupling between the host structure and piezoelectric stack actuators; the H 2 norm approach to search for optimal placement of actuators and sensors; and finally some aspects in robust control techniques. The electro-mechanical behavior of piezoelectric elements is directly related to the successful application of the actuators in truss structures. In order to achieve the desired damping in the interested bandwidth frequency it is used the H ∞ output feedback solved by convex optimization. The constraints to be reached are written by linear matrix inequalities (LMI). The paper concludes with a numerical example, using Matlab and Simulink, in a cantilevered, 2-bay space truss structure. The results demonstrated the approach applicability.
Resumo:
Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.
Resumo:
Flutter is an in-flight vibration of flexible structures caused by energy in the airstream absorbed by the lifting surface. This aeroelastic phenomenon is a problem of considerable interest in the aeronautic industry, because flutter is a potentially destructive instability resulting from an interaction between aerodynamic, inertial, and elastic forces. To overcome this effect, it is possible to use passive or active methodologies, but passive control adds mass to the structure and it is, therefore, undesirable. Thus, in this paper, the goal is to use linear matrix inequalities (LMIs) techniques to design an active state-feedback control to suppress flutter. Due to unmeasurable aerodynamic-lag states, one needs to use a dynamic observer. So, LMIs also were applied to design a state-estimator. The simulated model, consists of a classical flat plate in a two-dimensional flow. Two regulators were designed, the first one is a non-robust design for parametric variation and the second one is a robust control design, both designed by using LMIs. The parametric uncertainties are modeled through polytopic uncertainties. The paper concludes with numerical simulations for each controller. The open-loop and closed-loop responses are also compared and the results show the flutter suppression. The perfomance for both controllers are compared and discussed. Copyright © 2006 by ABCM.