Advancements in power electronic semiconductor switching devices have lead to significantly faster switching times. In motor and generator applications, the fast switching times of pulse width modulated (PWM) inverters lead to overvoltages caused by voltage reflections with shorter and shorter cables. These excessive overvoltages may lead to a failure of the electrical machine in a matter of months. In this thesis, the causes behind the overvoltage phenomenon as well as its different mitigation techniques are studied. The most suitable techniques for mitigating the overvoltage phenomenon in wind power generator applications are chosen based on both simulations and actual measurements performed on a prototype. An RC filter at the terminals of the electrical machine and an inverter output filter designed to reduce the rise and fall times of voltage pulses are presented as a solution to the overvoltage problem. The performance and losses of both filter types are analysed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis includes several thermal hydraulic analyses related to the Loviisa WER 440 nuclear power plant units. The work consists of experimental studies, analysis of the experiments, analysis of some plant transits and development of a calculational model for calculation of boric acid concentrations in the reactor. In the first part of the thesis, in the case of won of boric acid solution behaviour during long term cooling period of LOCAs, experiments were performed in scaled down test facilities. The experimental data together with the results of RELAPS/MOD3 simulations were used to develop a model for calculations of boric acid concentrations in the reactor during LOCAs. The results of calculations showed that margins to critical concentrations that would lead to boric acid crystallization were large, both in the reactor core and in the lower plenum. This was mainly caused by the fact that water in the primary cooling circuit includes borax (Na)BsO,.IOHZO), which enters the reactor when ECC water is taken from the sump and greatly increases boric acid solubility in water. In the second part, in the case of simulation of horizontal steam generators, experiments were performed with PACTEL integral test loop to simulate loss of feedwater transients. The PACTEL experiments, as well as earlier REWET III natural circulation tests, were analyzed with RELAPS/MOD3 Version Sm5 code. The analysis showed that the code was capable of simulating the main events during the experiments. However, in the case of loss of secondary side feedwater the code was not completely capable to simulate steam superheating in the secondary side of the steam generators. The third part of the work consists of simulations of Loviisa VVER reactor pump trip transients with RELAPSlMODI Eur, RELAPS/MOD3 and CATHARE codes. All three codes were capable to simulate the two selected pump trip transients and no significant differences were found between the results of different codes. Comparison of the calculated results with the data measured in the Loviisa plant also showed good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ethylbenzene dehydrogenation in the presence of steam is the main commercial route to produce styrene. The industrial catalyst is chromium and potassium-doped hematite, which easily deactivates with time due to potassium loss. In order to find non-toxic and potassium free catalysts, the promoter action of zinc on hematite was studied in this work. It was found that zinc acts as structural promoter by stabilizing the Fe3+ species (active phase) as maghemite. Although it decreases the specific surface area, it increases four times the catalytic activity as compared to hematite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biodiesel was produced by the transesterification of neutral soybean oil and anhydrous ethanol using NaOH as catalyst. Combinations of biodiesel and diesel in the proportions of 0, 5, 10, 20, 40, 60, 80 and 100% were tested, respectively, as fuel in an energy generator. The average consumption and mixture performance were analysed. The tests showed a reduction in Diesel oil consumption when mixed with up to 20% of biodiesel. The quality characteristics of these fuels were analyzed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of cobalt catalysts to produce hydrogen from ethanol is the goal of this investigation. Co/Al2O3 catalysts were prepared by impregnation and characterized by atomic absorption, nitrogen adsorption, X-ray diffraction, Raman spectroscopy, temperature programmed reduction and carbon analysis. The catalysts contained Co3O4 oxide and Co3+ and Co2+ species interacting with alumina. The cobalt load affects the crystal size and the crystalline structure and higher Co loads influence the reaction mechanism, changing the selectivity of the catalysts, decreasing the amount of CO produced and avoiding the formation of products catalyzed by the support. The ethanol conversion was 50-70% with 10-<1% of CO in the hydrogen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several extraction procedures are described for the determination of exchangeable and fixed ammonium, nitrate + nitrite, total exchangeable nitrogen and total nitrogen in certified reference soils and petroleum reservoir rock samples by steam distillation and indophenol method. After improvement of the original distillation system, an increase in worker safety, a reduction in time consumption, a decrease of 73% in blank value and an analysis without ammonia loss, which could possibly occur, were achieved. The precision (RSD < 8%, n = 3) and the detection limit (9 mg kg-1 NH4+-N) are better than those of published procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ONIOM method was used to calculate the proton affinities (PA) of n-alkylamines (CnH2n+1NH2, n = 3 to 6, 8, 10, 12, 14, 16 and 18). The calculations were carried out at several levels (HF, MP2, B3LYP, QCISD(T), ...) using Pople basis sets and at the QCISD(T) level using basis sets developed by the generator coordinate method (GCM) and adapted to effective core potentials. PAs were also obtained through the GCM and high level methods, like ONIOM[QCISD(T)/6-31+G(2df,p):MP2/6-31G+G(d,p))//ONIOM[MP2/6-31+G(d,p):HF/6-31G]. The average error using the GCM, with respect to experimental data, was 3.4 kJ mol-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityön tavoitteena on selvittää Loviisan ydinvoimalaitoksen höyryturbiinin hyötysuhteen parantamismahdollisuuksia. Työn kuvaan liittyvät oleellisesti höyryturbiinin siipivyöhykkeiden nopeuskolmioiden sekä hyötysuhteiden laskenta. Höyryturbiinien kehityskaarta sekä turbiinin häviökerrointen laskentayhtälöitä on esitetty useasta eri lähteestä ja vuosikymmeniltä. Työssä selvitettiin uusimpia ydinvoimalaitosten kostea höyryturbiinien suunnitteluperusteita lukuisista eri lähteistä. Kaikkien lähteiden mukaan kostean höyryn alueella tapahtuvaa paisuntaa on haasteellista mallintaa. Työssä on esitelty artikkeleissa tulleita eri näkökulmia höyryturbiinien suorituskyvyn parantamiseksi, sekä rakenteellisia että laskennallisia. Työssä esitellään monia turbiinin virtauksen ja suorituskyvyn laskentamenetelmiä. Esimerkiksi Baumannin säännön laskenta on yksinkertainen tapa käsitellä turbiinin suorituskykyä kostean höyryn alueella. Keskeisimpiä tehtyjä havaintoja oli se, että korkeapaineturbiinin ensimmäisestä vaiheesta löytyi mahdollista parannuspotentiaalia Loviisaan ydinvoimalaitoksen tehon lisäämiseksi. Ensimmäisessä vaiheessa on oletettu siipien olevan Laval –tyyppisiä, mutta käytännössä näin ei ole. Korkeapaineturbiinin nykyisen turbosuuttimen toimintaa voitaisiin tehostaa. Lisäksi Loviisan matalapaineturbiinin viimeisen siipivaiheen jälkeen aiheutuu suuret ulosvirtaushäviöt. Osa suurinopeuksisen virtauksen energiasta pystyttäisiin kuitenkin hyödyntämään vielä ulosvirtauskanavassa olevalla diffuusorilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis examines and explains the procedure used to redesign the attachment of permanent magnets to the surface of the rotor of a synchronous generator. The methodology followed to go from the actual assembly to converge to the final purposed innovation was based on the systematic approach design. This meant that first a series of steps had to be predefined as a frame of reference later to be used to compare and select proposals, and finally to obtain the innovation that was sought. Firstly, a series of patents was used as the background for the upcoming ideas. To this end, several different patented assemblies had been found and categorized according the main element onto which this thesis if focused, meaning the attachment element or method. After establishing the technological frame of reference, a brainstorm was performed to obtain as many ideas as possible. Then these ideas were classified, regardless of their degree of complexity or usability, since at this time the quantity of the ideas was the important issue. Subsequently, they were compared and evaluated from different points of view. The comparison and evaluation in this case was based on the use of a requirement list, which established the main needs that the design had to fulfill. Then the selection could be done by grading each idea in accordance with these requirements. In this way, one was able to obtain the idea or ideas that best fulfilled these requirements. Once all of the ideas were compared and evaluated, the best or most suitable idea or ideas were separated. Finally, the selected idea or ideas was/were analyzed in extension and a number of improvements were made. Consequently, a final idea was refined and made more suitable at its performance, manufacture, and life cycle assessment. Therefore, in the end, the design process gave a solution to the problem pointed out at the beginning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchronous motors are used mainly in large drives, for example in ship propulsion systems and in steel factories' rolling mills because of their high efficiency, high overload capacity and good performance in the field weakening range. This, however, requires an extremely good torque control system. A fast torque response and a torque accuracy are basic requirements for such a drive. For large power, high dynamic performance drives the commonly known principle of field oriented vector control has been used solely hitherto, but nowadays it is not the only way to implement such a drive. A new control method Direct Torque Control (DTC) has also emerged. The performance of such a high quality torque control as DTC in dynamically demanding industrial applications is mainly based on the accurate estimate of the various flux linkages' space vectors. Nowadays industrial motor control systems are real time applications with restricted calculation capacity. At the same time the control system requires a simple, fast calculable and reasonably accurate motor model. In this work a method to handle these problems in a Direct Torque Controlled (DTC) salient pole synchronous motor drive is proposed. A motor model which combines the induction law based "voltage model" and motor inductance parameters based "current model" is presented. The voltage model operates as a main model and is calculated at a very fast sampling rate (for example 40 kHz). The stator flux linkage calculated via integration from the stator voltages is corrected using the stator flux linkage computed from the current model. The current model acts as a supervisor that prevents only the motor stator flux linkage from drifting erroneous during longer time intervals. At very low speeds the role of the current model is emphasised but, nevertheless, the voltage model always stays the main model. At higher speeds the function of the current model correction is to act as a stabiliser of the control system. The current model contains a set of inductance parameters which must be known. The validation of the current model in steady state is not self evident. It depends on the accuracy of the saturated value of the inductances. Parameter measurement of the motor model where the supply inverter is used as a measurement signal generator is presented. This so called identification run can be performed prior to delivery or during drive commissioning. A derivation method for the inductance models used for the representation of the saturation effects is proposed. The performance of the electrically excited synchronous motor supplied with the DTC inverter is proven with experimental results. It is shown that it is possible to obtain a good static accuracy of the DTC's torque controller for an electrically excited synchronous motor. The dynamic response is fast and a new operation point is achieved without oscillation. The operation is stable throughout the speed range. The modelling of the magnetising inductance saturation is essential and cross saturation has to be considered as well. The effect of cross saturation is very significant. A DTC inverter can be used as a measuring equipment and the parameters needed for the motor model can be defined by the inverter itself. The main advantage is that the parameters defined are measured in similar magnetic operation conditions and no disagreement between the parameters will exist. The inductance models generated are adequate to meet the requirements of dynamically demanding drives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli tutkia höyrykattiloiden leijukerrosten käytettävyysongelmia ja kirjallisuudesta löytyvien diagnostiikkamenetelmien toimivuutta leijukerroksen tilan ja käytettävyysongelmien tunnistamiseksi. Diagnostiikkamenetelmien toimivuutta testattiin VTT:n kiertoleijukoelaitteen prosessimittauksiin perustuen. Analysoinnissa käytettiin prosessimittauksia, jotka ovat yleisesti käytössä energiantuotannon leijukerroskattiloissa. Analysoitavina koeajotapauksina olivat kylmäkokeet partikkelikokojakaumaltaan vaihtelevalle leijutusmateriaalille, tuhkapartikkelien aiheuttama petimateriaalin karkeneminen ja agglomeroituminen, sekä vaihtelevien ajoarvojen vaikutus leijukerroksen hydrodynaamiseen käyttäytymiseen. Kokeellisesta osiosta saaduista tuloksista selvisi leijutusilman tilavuusvirran, petimassan ja partikkelikoon vaikutus analysoitavaan prosessimittaukseen. Tuloksista oli havaittavissa myös kiertävän petimateriaalin ja pohjapedin osuuksien vaikutus mitattuun painesignaaliin. Petipartikkelien agglomeroitumisen ja karkenemisen todettiin lisäävän kiertoleijukoelaitteistossa nousuputken pohjapedin määrää suhteessa kiertävään petimateriaaliin, mikä voitiin havaita painemittauksista.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is proposed for the determination of the moisture content of aromatic plants. This method is based on the co-distillation of the starting material in a modified Clevenger apparatus with four organic solvents (toluene, cyclohexane, dichloromethane and carbon tetrachloride). The results were compared with those obtained by oven drying at 105 ºC and steam distillation of the essential oil. The efficiencies of the methods were shown to be equivalent. The solvent distillation method was more practical, especially with respect to operating time (2 h).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lignin was used as a natural adhesive to manufacture Vitis vinifera fiberboards. The fiberboards were produced at laboratory scale by adding powdered lignin to material that had previously been steam-exploded under optimized pretreatment and pressing conditions. The kraft lignin used was washed several times with an acidic solution to eliminate any contaminants and low molecular weight compounds. This research studied the effects of amounts of lignin ranging from 5% to 20% on the properties of Vitis vinifera fiberboards. The fiberboard properties evaluated were density, water resistance in terms of thickness swelling, water absorption, and the mechanical properties in terms of modulus of rupture, modulus of elasticity, and internal bond. Results showed that fiberboards made from Vitis vinifera without lignin addition had weaker mechanical properties. However, the fiberboards obtained using acid-washed kraft lignin as a natural adhesive had good mechanical and water resistance properties that fully satisfied the relevant standard specifications

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three Croton species, C. zenhtneri, C. nepetaefolius and C. argyrophylloides, were collected at two different times, 6:00 and 13:00 h, their essential oils were extracted by steam distillation and analyzed by gas Chromatography / Mass Spectrometry. The percentage yield of oil constituents changes along the day. The oils were submitted to the antioxidant test thiobarbituric acid reactive species, using BHT and a-tocoferol as the reference compounds. All oils exhibited good antioxidant activities. In general, C. zenhtneri and C. argyrophylloides essential oils showed higher antioxidant activity than C. nepetaefolius.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leaves of Lippia alba were submitted to six different drying treatments, using air at ambient temperature and heated up to 80 °C. The essential oil was extracted by steam distillation and analyzed by GC-MS. For the dried leaves, the oil content was reduced by 12 to 17% when compared with the fresh plant (0.66%). The major oil component was citral, representing 76% for the fresh plant, and varying from 82 to 84% for the dried material. These results showed that L. alba can be submitted to a drying process of up to 80 ºC without degradation and/or loss of the major, [LC1] active component.