951 resultados para solid structure timber
Resumo:
PLOS ONE, 4(8):ARTe6820
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
A thesis submitted in fulfilment of the requirements for the Degree of Doctor of Philosophy in Sanitary Engineering in the Faculty of Sciences and Technology of the New University of Lisbon
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Biotecnologia
Resumo:
Dissertação de Mestrado em Gestão Integrada de Qualidade, Ambiente e Segurança
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.
Resumo:
The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.
Resumo:
We are presenting a simple, low-cost and rapid solid-state optical probe for screening chlorpromazine (CPZ) in aquacultures. The method exploits the colourimetric reaction between CPZ and Fe(III) ion that occurs at a solid/liquid interface, the solid layer consisting of ferric iron entrapped in a layer of plasticized PVC. If solutions containing CPZ are dropped onto such a layer, a colour change occurs from light yellow to dark pink or even light blue, depending on the concentration of CPZ. Visual inspection enables the concentration of CPZ to be estimated. The resulting colouration was also monitored by digital image collection for a more accurate quantification. The three coordinates of the hue, saturation and lightness system were obtained by standard image processing along with mathematical data treatment. The parameters affecting colour were assessed and optimized. Studies were conducted by visible spectrophotometry and digital image acquisition, respectively. The response of the optimized probe towards the concentration of CPZ was tested for several mathematical transformations of the colour coordinates, and a linear relation was found for the sum of hue and luminosity. The limit of detection is 50 μM (corresponding to about 16 μg per mL). The probe enables quick screening for CPZ in real water samples with prior sample treatment.
Resumo:
This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
Dissertação para Obtenção de Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
RESUMO:Staphylococcus aureus é um dos principais agentes patogénicos humanos, sendo frequentemente associado a infecções nosocomiais e infecções na comunidade. A prevalência de S. aureus resistentes à meticilina (MRSA) em hospitais portugueses é uma das mais elevadas da Europa e tem sido caracterizada extensivamente; contrariamente, a prevalência e epidemiologia de MRSA na comunidade em Portugal não tem sido devidamente seguida. Com o objectivo de compreender as causas possíveis do aumento na frequência de MRSA num dos maiores hospitais centrais portugueses (HSM) ao longo de 17 anos, isolados de MRSA recolhidos em 1993 (n=54) e 2010 (n=180) de pus, sangue e urina foram analisados por PFGE, MLST, tipagem do spa e tipagem de SCCmec. Os resultados mostraram que ocorreu uma mudança global nos tipos clonais predominantes, onde o clone ST22-IVh substituiu os clones, ST239-IIIvar e ST247-I, representando mais de 70% da população actual. Além disso, entre 1993 e 2010 verificou-se um aumento na diversidade genética dos tipos clonais de MRSA. Para determinar a frequência e a natureza clonal de MRSA e S. aureus sensíveis à meticilina (MSSA) isolados de infecções de pele e tecidos moles (SSTI) em pessoas que frequentam centros de saúde em Portugal, 73 amostras foram recolhidas em nove centros de saúde (Rede Médicos Sentinela). Isolou-se um total de 40 S. aureus (55%), dos quais 17,5% eram MRSA. Os isolados de MRSA pertenciam aos clones ST22-IVh (n=4), ST5-IVc (n=2) e ST105-II (n=1), que foram descritos neste estudo como sendo clones de origem hospitalar. Os nossos resultados sugerem que o aumento da frequência de MRSA no HSM pode estar associado à emergência de um clone de MRSA com maior capacidade epidémica. Além disso, verificámos que a principal causa de SSTI em pessoas que frequentam centros de saúde em Portugal são MRSA de origem hospitalar e não MRSA associados à comunidade.------ABSTRACT: Staphylococcus aureus is one of the most important human pathogens, being a major cause of infections worldwide both in the hospital and in the community. In Portugal, the prevalence of methicillin resistant S. aureus (MRSA) in hospitals is one of the highest in Europe and has been characterized extensively; contrarily the prevalence and epidemiology of MRSA in the community has not been followed in a meaningful way. To understand the epidemiological events that could explain a steep increase in MRSA frequency in a major Portuguese central hospital (HSM) within a 17 year period, two MRSA collections recovered in 1993 (n=54) and 2010 (n=180) from pus, blood and urine were analyzed by PFGE, MLST, spa and SCCmec typing. The results showed that a major clonal shift occurred, wherein ST22-IVh clone has replaced the previous ST239-IIIvar and ST247-I clones and accounts for more than 70% of the present population. Moreover, an increase in genetic diversity of MRSA clonal types was observed between the two study periods. With the aim of determining the frequency and clonal nature of MRSA and methicillin-susceptible S. aureus (MSSA) causing skin and soft tissue infections (SSTI) in patients attending healthcare centers in Portugal, 73 samples were collected from nine healthcare centers (Medicos Sentinela Network). A total of 40 S. aureus were isolated, accounting for 55% of the SSTI, of which 17.5% were MRSA. MRSA isolates belonged to ST22-IVh (n=4), ST5-IVc (n=2) and ST105-II (n=1) that have also been described in the hospital in an equivalent period. Our results suggest that the increase in MRSA frequency in HSM may be associated to the emergence of a MRSA clone with higher epidemic potential. Moreover, we propose that the spillover of MRSA from the hospital rather than community-associated-MRSA was the main cause of SSTI in persons attending healthcare centers in Portugal.
Resumo:
Robotics research in Portugal is increasing every year, but few students embrace it as one of their first choices for study. Until recently, job offers for engineers were plentiful, and those looking for a degree in science and technology would avoid areas considered to be demanding, like robotics. At the undergraduate level, robotics programs are still competing for a place in the classical engineering graduate curricula. Innovative and dynamic Master's programs may offer the solution to this gap. The Master's degree in autonomous systems at the Instituto Superior de Engenharia do Porto (ISEP), Porto, Portugal, was designed to provide a solid training in robotics and has been showing interesting results, mainly due to differences in course structure and the context in which students are welcomed to study and work.