927 resultados para sensor nodes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0×10-6-1.0×10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PVC based membranes of a double armed crown ether, N, N'-dibenzyl, 1,4,10,13-tetraoxa-7, 16-diaza cyclooctadecane (I) as ionophore with sodium tetra phenyl borate (NaTPB) as anion excluder and with many plasticizing solvent mediators have been prepared and used for Hg(II) ion determination. The membrane with DBBP (dibutyl butyl phosphonate ) as plasticizer with various ingredients in the ratio PVC: I: NaTPB: DBBP (150: 12: 2: 100) shows the best results in terms of working concentration range (3.1x10-5-1.0x10-tM) with a Nernstian slope (29.0′0.5 mV/decade of activity). The electrode works in the pH range 2.1-4.5. The response time of the sensor is 15s and it can be used for about 4 months in aqueous as well as in non-aqueous medium. It has good stability and reproducibility. The potentiometric selectivity coefficient values for mono-, di-, and trivalent cations are tabulated. The sensor is highly selective for Hg2+ in the presence of normal interferents like cadmium, silver, sodium and iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a newly designed colormetric sensor sensitive to pH value based on a gold nanocomposite composed of gold nanoparticles and pH-sensitive polymer{dodecylthioether end functionalized poly[2-(diethlamino) ethyl methacrylate], poly(DEAEMA)-DDT}. We have shown that this design can produce stable GNP precipitate under weakly basic condition(pH=7.5) and this precipitate can be dispersed in acidic solution(pH=4.0), due to the 2-(diethylamino) ethyl methacrylate protonated by H+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The novel nanoparticles, [Ru(bPY)(3)](2)SiW12O40 center dot 2H(2)O(2) were firstly synthesized and characterized by elemental analysis, IR, and TEM. The nanoparticles were used to fabricate a chemically modified carbon paste electrode (CPE) by dispersing nanoparticles and graphite powder in silicone grease. Thus-prepared CPE shows bifunctional electrocatalytic activities towards the reduction of nitrite and the oxidation of oxalate, and exhibits sensitive electrochemiluminescence (ECL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)3" and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)3 2'-doped silica nanoparticles and Au nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative electrochemilumineseence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin-avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2'-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2'-bipyridine) ruthenium(II) label was attached to the prepared avidin surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different effects of divalent metal ions on electrochemiluminescence (ECL) sensor with Ru(bPY)(3)(2+) immobilized in Eastman-AQ membrane were investigated. Mg2+,Ca2+ and Fe2+ can elevate the ECL of Ru(bpY)(3)(2+)/proline; while metal ions that underwent redox reactions on the electrode such as Mn2+ and Co2+ presented intensive quenching effects on Ru(bpy)(3)(2+) ECL. Also, the quenching effect of Mn2+ on the ECL sensor with Ru(bpY)(3)(2+) immobilized in Eastman-AQ membrane enhanced to about 30-folds compared with the case that Ru(bpy)(3)(2+) was dissolved in phosphate buffer, and the enhanced quenching effects of Mn2+ were studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel nonenzymatic glucose sensor was developed based on the renewable Ni nanoparticle-loaded carbon nanofiber paste (NiCFP) electrode. The NiCF nanocomposite was prepared by combination of electrospinning technique with thermal treatment method. The scanning electron microscopy (SEM) and transmission electron microscopy (TEM) images showed that large amounts of spherical nanoparticles were well dispersed on the surface or embedded in the carbon nanofibers. And the nanoparticles were composed of Ni and NiO, as revealed by energy dispersive X-ray spectroscopy (EDX) and X-ray powder diffraction (XRD). In application to nonenzymatic glucose determination, the renewable NiCFP electrodes, which were constructed by simply mixing the electrospun nanocomposite with mineral oil, exhibited strong and fast amperometric response without being poisoned by chloride ions. Low detection limit of 1 mu M with wide linear range from 2 mu M to 2.5 mM (R = 0.9997) could be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new fluorescent sensor for the sensitive and selective detection of cyanide (CN-) in aqueous media was developed herein. The sensing approach is based on CN--modulated quenching behavior of Cu2+ toward the photoluminescence (PL) of CdTe quantum dots (QDs). In the presence of CN-, the PL of QDs that have been quenched by Cu2+ was found to be efficiently recovered, which then allows the detection of CN- in a very simple approach. Experimental results showed that the pH of the buffer solution, concentration of copper ions, and size of CdTe QDs all influenced the response of the sensor to CN-. Under the optimal conditions, a good linear relationship between the PL intensity and the concentration of CN- can be obtained in the range of 3.0 x 10(-7) to 1.2 x 10(-5) M, with a detection limit as low as 1.5 x 10(-7) M. In addition, the present fluorescent sensor possesses remarkable selectivity for cyanide over other anions, and negligible influences were observed on the cyanide detection by the coexistence of other anions or biological species (such as albumin and typical blood constituents).