946 resultados para power, politics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the era of fast product development and customized product requirements, the concept of product platform has proven its power in practice. The product platform approach has enabledcompanies to increase the speed of product introductions while simultaneously benefit from efficiency and effectiveness in the development and production activities. The product platforms are technological bases, which can be used to develop several derivative products, and hence, the differentiation can be pushed closer to the product introduction. The product platform development has some specific features, which differ somewhat from the product development of single products. The time horizon is longer, since the product platform¿slife cycle is longer than individual product's. The long time-horizon also proposes higher market risks and the use of new technologies increases the technological risks involved. The end-customer interface might be far away, but there is not a lack of needs aimed at the product platforms ¿ in fact, the product platform development is very much balancing between the varying needs set to it by thederivative products. This dissertation concentrated on product platform development from the internal product lines' perspective of a singlecase. Altogether six product platform development factors were identified: 'Strategic and business fit of product platform', 'Project communication and deliverables', 'Cooperation with product platform development', 'Innovativeness of product platform architecture and features', 'Reliability and quality of product platform', and 'Promised schedules and final product platform meeting the needs'. From the six factors, three were found to influence quite strongly the overall satisfaction, namely 'Strategic and business fit of product platform', 'Reliability and quality of product platform', and 'Promised schedules and final product platform meeting the needs'. Hence, these three factors might be the ones a new product platform development unit should concentrate first in order to satisfy their closest customers, the product lines. The 'Project communication and deliverables' and 'Innovativeness of product platform architecture and features' were weaker contributors to the overall satisfaction. Overall, the factors explained quite well the satisfaction of the product lines with product platform development. Along the research, several interesting aspects about the very basic nature of the product platform development were found. The long time horizon of the product platform development caused challenges in the area of strategic fIT - a conflict between the short-term requirements and long term needs. The fact that a product platform was used as basis of several derivative products resulted into varying needs, and hence the match with the needs and the strategies. The opinions, that the releases of the larger product lines were given higher priorities, give an interesting contribution to the strategy theory of powerand politics. The varying needs of the product lines, the strengths of them as well as large number of concurrent releases set requirements to prioritization. Hence, the research showed the complicated nature of the product platform development in the case unIT - the very basic nature of the product platform development might be its strength (gaining efficiency and effectiveness in product development and product launches) but also the biggest challenge (developing products to meet several needs). As a single case study, the results of this research are not directly generalizable to all the product platform development activities. Instead, the research serves best as a starting point for additional research as well as gives some insights about the factors and challengesof one product development unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Design of newly engineered microbial strains for biotechnological purposes would greatly benefit from the development of realistic mathematical models for the processes to be optimized. Such models can then be analyzed and, with the development and application of appropriate optimization techniques, one could identify the modifications that need to be made to the organism in order to achieve the desired biotechnological goal. As appropriate models to perform such an analysis are necessarily non-linear and typically non-convex, finding their global optimum is a challenging task. Canonical modeling techniques, such as Generalized Mass Action (GMA) models based on the power-law formalism, offer a possible solution to this problem because they have a mathematical structure that enables the development of specific algorithms for global optimization. Results: Based on the GMA canonical representation, we have developed in previous works a highly efficient optimization algorithm and a set of related strategies for understanding the evolution of adaptive responses in cellular metabolism. Here, we explore the possibility of recasting kinetic non-linear models into an equivalent GMA model, so that global optimization on the recast GMA model can be performed. With this technique, optimization is greatly facilitated and the results are transposable to the original non-linear problem. This procedure is straightforward for a particular class of non-linear models known as Saturable and Cooperative (SC) models that extend the power-law formalism to deal with saturation and cooperativity. Conclusions: Our results show that recasting non-linear kinetic models into GMA models is indeed an appropriate strategy that helps overcoming some of the numerical difficulties that arise during the global optimization task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study deals with the statistical properties of a randomization test applied to an ABAB design in cases where the desirable random assignment of the points of change in phase is not possible. In order to obtain information about each possible data division we carried out a conditional Monte Carlo simulation with 100,000 samples for each systematically chosen triplet. Robustness and power are studied under several experimental conditions: different autocorrelation levels and different effect sizes, as well as different phase lengths determined by the points of change. Type I error rates were distorted by the presence of autocorrelation for the majority of data divisions. Satisfactory Type II error rates were obtained only for large treatment effects. The relationship between the lengths of the four phases appeared to be an important factor for the robustness and the power of the randomization test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen tarkoituksena oli selvittää typenoksidien vähennysmahdollisuudet Stora Enson Varkauden tehtaiden sellutehtaalla ja voimalaitoksella. Tutkimuksessa käsiteltiin tehdasalueen suurimpia typenoksidien päästölähteitä: soodakattilaa, meesauunia, kuorikattilaa, öljykattilaa ja muovi-alumiinijakeen kaasutuslaitosta. Tutkimuksessa selvitettiin typenoksidipäästöjen syntymekanismit ja erilaisiin polttotekniikoihin soveltuvat typenoksidien vähennystekniikat. Varkauden tehtaiden typenoksidien vuosipäästö vuonna 2001 oli 836 tonnia. Kansallinen lainsäädäntö, kansainväliset sopimukset sekä paras käytettävissä oleva tekniikka (BAT) huomioiden selvitettiin kuhunkin kohteeseen parhaiten soveltuvat ratkaisut. Tutkimuksen perusteella laadittiin toimenpideohjelma, joka määrittelee suositeltavan toteutusjärjestyksen typenoksidien vähennystoimenpiteille. Toimenpideohjelman tärkeimpinä kriteereinä pidettiin vuonna 2004 tulevan uuden ympäristöluvan arvioituja luparajoja sekä toimenpiteiden kustannustehokkuutta. Toteutusjärjestyksessä ensimmäiseksi valittiin koeajojakson järjestäminen ajon optimoimiseksi kiertopetikattilalla ja toiseksi meesauunin ajon optimointi jatkuvatoimisen NOx-analysaattorin avulla. Seuraaviksi toimenpiteiksi ehdotettiin vertikaali-ilmajärjestelmän käyttöönottoa soodakattilalla sekä SNCR-järjestelmän asennusta kuorikattilalle. Saavutettava NOx-vähennys tulisi olemaan 10 – 45 % ja hinta 30 – 3573 EUR vähennettyä NOx-tonnia kohti. Tutkimuksen osana Ilmatieteen laitoksella teetetyn typenoksidien leviämisselvityksen mukaan Stora Enson tehtaiden NOx-päästöjen vaikutus Varkauden ilmanlaatuun on hyvin pieni. Suurin osa NOx-päästöistä aiheutuu liikenteestä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sähkönkulutuksen lyhyen aikavälin ennustamista on tutkittu jo pitkään. Pohjoismaisien sähkömarkkinoiden vapautuminen on vaikuttanut sähkönkulutuksen ennustamiseen. Aluksi työssä perehdyttiin aiheeseen liittyvään kirjallisuuteen. Sähkönkulutuksen käyttäytymistä tutkittiin eri aikoina. Lämpötila tilastojen käyttökelpoisuutta arvioitiin sähkönkulutusennustetta ajatellen. Kulutus ennusteet tehtiin tunneittain ja ennustejaksona käytettiin yhtä viikkoa. Työssä tutkittiin sähkönkulutuksen- ja lämpötiladatan saatavuutta ja laatua Nord Poolin markkina-alueelta. Syötettävien tietojen ominaisuudet vaikuttavat tunnittaiseen sähkönkulutuksen ennustamiseen. Sähkönkulutuksen ennustamista varten mallinnettiin kaksi lähestymistapaa. Testattavina malleina käytettiin regressiomallia ja autoregressiivistä mallia (autoregressive model, ARX). Mallien parametrit estimoitiin pienimmän neliösumman menetelmällä. Tulokset osoittavat että kulutus- ja lämpötiladata on tarkastettava jälkikäteen koska reaaliaikaisen syötetietojen laatu on huonoa. Lämpötila vaikuttaa kulutukseen talvella, mutta se voidaan jättää huomiotta kesäkaudella. Regressiomalli on vakaampi kuin ARX malli. Regressiomallin virhetermi voidaan mallintaa aikasarjamallia hyväksikäyttäen.