939 resultados para poly vinyl acetate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modified microfiltration membrane has been prepared by blending a matrix polymer with a functional polymer. Cellulose acetate (CA) was blended with polyethyleneimine (PEI), which was then crosslinked by polyisocyanate, in a mixture of solvents. In the membrane, PEI can supply coupling sites for ligands in affinity separation or be used as ligands for metal chelating, removal of endotoxin or ion exchange. The effects of the time of phase inversion induced by water vapor, blended amount of PEI and amount of crosslinking agent on membrane performance were investigated. The prepared blend membranes have specific surface area of 12.04-24.11 m(2)/g and pure water flux (PWF) of 10-50 ml/cm(2) min with porosity of 63-75%. The membranes, made of 0.15 50 wt.% PEI/CA ratio and 0.5 crosslinking agent/PEI ratio, were applied to adsorbing Cu2+ and bovine serum albumin (BSA) individually. The maximum adsorption capacity of Cu2+ ion on the blend membrane is 7.42 mg/g dry membrane. The maximum adsorption capacities of BSA on the membranes with and without chelating Cu2+ ion are 86.6 and 43.8 mg/g dry membrane, respectively. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel poly-l-arginine microcapsule was prepared due to its nutritional function and pharmacological efficacy. A high-voltage electrostatic droplet generator was used to make uniform microcapsules. The results show that the membrane strength and permeating property are both remarkably affected with the changes of sodium alginate concentration. With the sodium alginate concentration increasing, gel beads sizes increase from 233 mum to 350 mum, release ratio is also higher at the same time, but the membrane strength decreases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have successfully achieved the integration of isothermal amplification and the subsequent analysis of specific gene fragments on poly(methyl methacrylate) microchips. In our experiments, loop-mediated isothermal amplification, which can offer higher specificity and efficiency than PCR, has been performed at a constant temperature (65 degreesC). After amplification, products could be either examined by the integrated microchip-based electrophoresis or directly observed by naked eye with SYBR Green I added into the reaction solution. By such an integrated microsystem, the amplification and the subsequent analysis of prostate-specific antigen gene with template concentration at 23 fg/muL could be finished within 15 min, which demonstrates its advantages of high specificity, good reproducibility, and fast speed in gene detection.