981 resultados para optical computed tomography


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impact of liver hypertrophy of the future liver remnant volume (FLR) induced by preoperative portal vein embolization (PVE) on the immediate postoperative complications after a standardized major liver resection. SUMMARY BACKGROUND DATA: PVE is usually indicated when FLR is estimated to be too small for major liver resection. However, few data exist regarding the exact quantification of sufficient minimal functional hepatic volume required to avoid postoperative complications in both patients with or without chronic liver disease. METHODS: All consecutive patients in whom an elective right hepatectomy was feasible and who fulfilled the inclusion and exclusion criteria between 1998 and 2000 were assigned to have alternatively either immediate surgery or surgery after PVE. Among 55 patients (25 liver metastases, 2 cholangiocarcinoma, and 28 hepatocellular carcinoma), 28 underwent right hepatectomy after PVE and 27 underwent immediate surgery. Twenty-eight patients had chronic liver disease. FLR and estimated rate of functional future liver remnant (%FFLR) volumes were assessed by computed tomography. RESULTS: The mean increase of FLR and %FFLR 4 to 8 weeks after PVE were respectively 44 +/- 19% and 16 +/- 7% for patients with normal liver and 35 +/- 28% and 9 +/- 3% for those with chronic liver disease. All patients with normal liver and 86% with chronic liver disease experienced hypertrophy after PVE. The postoperative course of patients with normal liver who underwent PVE before right hepatectomy was similar to those with immediate surgery. In contrast, PVE in patients with chronic liver disease significantly decreased the incidence of postoperative complications as well as the intensive care unit stay and total hospital stay after right hepatectomy. CONCLUSIONS: Before elective right hepatectomy, the hypertrophy of FLR induced by PVE had no beneficial effect on the postoperative course in patients with normal liver. In contrast, in patients with chronic liver disease, the hypertrophy of the FLR induced by PVE decreased significantly the rate of postoperative complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Standard chest radiographs have been shown to be insensitive for the diagnosis of morphologic abnormalities of airways. Computed tomography is the most sensitive and specific investigation to diagnose emphysema. However, as emphysema may be missed on computed tomography, this investigation cannot be used to definitely rule out the diagnosis. Computed tomography may contribute to the investigation of bronchiolitis, and it is now considered as the gold standard for establishing the diagnosis of bronchiectasis. Imaging may contribute to identify complications such as bronchopulmonary infection, pulmonary hypertension, pneumothorax, cancer of the lung, compressive bullae, and pulmonary embolism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To report a novel maculopathy in a patient with SCA1. To describe autofluorescence findings in family with SCA7 and associated cone-rod retinal dysfunction.Methods: 4 affected patients from two families were assessed to investigate a progressive loss of visual acuity (VA). Examinations included fundus photography, autofluorescence (AF) fundus fluorescein angiogragraphy (FFA) and optical coherence tomography. Electroretinogram (full-field) was performed in 2 affected patients. All patients had color vision testing using Ishihara pseudoisochromatic plates. Molecular analysis was performed in family 2.Results: The patient with known diagnosis of SCA1 had a visual acuity of 20/200 bilaterally and dyschromatopsia. He had saccadic pursuit. Fundus examination showed mild retinal pigment epithelium (RPE) changes at the macula. OCT showed bilateral macular serous detachment, which was not obvious at the FFA and explained his VA. AF imaging showed a central hyperfluorescence. The 45 year old proband from family 2 had a visual acuity of 200/20 and dyschromatopsia. ERG testing showed cone type dysfunction of photoreceptors. Her daughter affected at a younger age had the same ERGs findings. Fundus examination showed mild RPE changes in proband, normal findings in her daughter. AF imaging of both patients showed a ring of high density AF around the fovea. The ring was also obvious on near infrared AF. Later onset of gait imbalance led to the diagnosis of SCA7Conclusions: Within the group of spinocerebellar ataxias, only the type 7 is associated with retinal dysfunction. We present the first report of maculopathy associated with SCA1 causing severe vision loss. The ring of high density AF in SCA7 confirmed an early retinal photoreceptor dysfunction in patient with normal fundus.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess the safety and efficacy of treatment of macular edema secondary to central retinal vein occlusion (CRVO) with intravitreal bevacizumab. PATIENTS AND METHOD: The ongoing prospective study included 8 consecutive patients (8 eyes) with macular edema secondary to CRVO (6 non ischemic and 2 ischemic), treated with intravitreal injection of 1.25 mg (0.05 mL) of bevacizumab. Main outcome was best corrected visual acuity (BCVA) and central foveal thickness (CFT) measured by optical coherence tomography monthly during one year. Retreatment criteria include decrease of BCVA, persistence of macular edema on angiograms and increase of CFT. RESULTS: Mean age of the eight patients was 68 years (range: 50-82 years). Mean duration of symptoms before injection was 98 days (range: 3-289). Mean follow-up was 3.25 months. At baseline, mean BCVA was 0.84 logMar and mean baseline CFT was 771 microm. Mean BCVA was 0.36 and mean CFT thickness was 275 microm (n = 8) at month 1, 0.41 and 411 microm at month 2 (n = 7), 0.3 and 344 microm at month 3 (n = 6), 0.3 and 397 microm at month 4 (n = 5), respectively. In 75 % of patients, a single injection was not sufficient, and retreatment needed. No serious adverse events were observed. CONCLUSIONS: Treatment of macular edema secondary to CRVO with intravitreal bevacizumab injection of 1.25 mg was well tolerated and associated with marked macular thickness reduction and BCVA improvement in all patients. A trend towards reduction of foveal thickness and improvement of visual acuity was observed in both acute and chronic CRVO.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Multidetector row computed tomography (MDCT) is the imaging modality of reference for the diagnosis of bronchiectasis. MDCT may also detect a focal stenosis, a tumor or multiple morphologic abnormalities of the bronchial tree. It may orient the endoscopist towards the abnormal bronchi, and in all cases assess the extent of the bronchial lesions. The CT findings of bronchial abnormalities include anomalies of bronchial division and origin, bronchial stenosis, bronchial wall thickening, lumen dilatation, and mucoid impaction. The main CT features of bronchiectasis are increased bronchoarterial ratio, lack of bronchial tapering, and visibility of peripheral airways. Other bronchial abnormalities include excessive bronchial collapse at expiration, outpouchings and diverticula, dehiscence, fistulas, and calcifications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Right hemispheric stroke aphasia (RHSA) rarely occurs in right- or left-handed patients with their language representation in right hemisphere (RH). For right-handers, the term crossed aphasia is used. Single cases, multiple cases reports, and reviews suggest more variable anatomo-clinical correlations. We included retrospectively from our stroke data bank 16 patients (right- and left-handed, and ambidextrous) with aphasia after a single first-ever ischemic RH stroke. A control group was composed of 25 successive patients with left hemispheric stroke and aphasia (LHSA). For each patient, we analyzed four modalities of language (spontaneous fluency, naming, repetition, and comprehension) and recorded eventual impairment: (1) on admission (hyperacute) and (2) between day 3 and 14 (acute). Lesion volume and location as measured on computed tomography (CT) and magnetic resonance imaging (MRI) were transformed into Talairach stereotaxic space. Nonparametric statistics were used to compare impaired/nonimpaired patients. Comprehension and repetition were less frequently impaired after RHSA (respectively, 56% and 50%) than after LHSA (respectively, 84% and 80%, P = 0.05 and 0.04) only at hyperacute phase. Among RHSA, fewer left-handers/ambidextrous than right-handers had comprehension disorders at second evaluation (P = 0.013). Mean infarct size was similar in RHSA and LHSA with less posterior RHSA lesions (caudal to the posterior commissure). Comprehension and repetition impairments were more often associated with anterior lesions in RHSA (Fisher's exact test, P < 0.05). Despite the small size of the cohort, our findings suggest increased atypical anatomo-functional correlations of RH language representation, particularly in non-right-handed patients. Rapport de synthèse : Des aphasies secondaires à un accident vasculaire ischémique cérébral (AVC) hémisphérique droit sont rarement rencontrées chez des patients droitiers ou gauchers avec une représentation du langage dans l'hémisphère droit. Chez les droitiers, on parle d'aphasie croisée. Plusieurs études sur le sujet ont suggéré des corrélations anatomocliniques plus variables. Dans notre étude, nous avons inclus rétrospectivement, à partir d'une base de données de patients avec un AVC, seize patients (droitiers, gauchers et ambidextres) souffrant d'une aphasie suite à un premier et unique AVC ischémique hémisphérique droit. Un groupe contrôle est composé de vingt-cinq patients successifs avec une aphasie suite à un AVC ischémique hémisphérique gauche. Pour chaque patient, nous avons analysé quatre modalités de langage, à savoir la fluence spontanée, la dénomination, la répétition et la compréhension et leur éventuelle atteinte à deux moments distincts : 1) à l'admission (phase hyperaiguë) et 2) entre le 3e et le 14e jour (phase aiguë). Le volume et la localisation de la lésion mesurés, soit sur un CT-scanner soit sur une imagerie par résonance magnétique cérébrale, ont été analysés à l'aide de l'échelle stéréotaxique de Talairach. Des statistiques non paramétriques ont été utilisées pour comparer les patients atteints et non atteints. . La compréhension et la répétition étaient moins souvent atteintes, seulement en phase hyperaiguë, après une aphasie suite à un AVC hémisphérique droit (resp. 56% et 50%) plutôt que gauche (resp. 84 % et 80%, p= 0.05 et 0.04). Parmi les aphasies suite à un AVC ischémique hémisphérique droit, moins de gauchers et d'ambidextres que de droitiers avaient des troubles de la compréhension lors de la seconde évaluation (p=0.013}. La .taille moyenne de la zone infarcie était semblable entre les aphasies droites et gauches, avec moins de lésions postérieures (caudale à la commissure postérieure) lors des aphasies droites. Les troubles de la répétition et de la compréhension étaient plus souvent associés à des lésions antérieures lors d'aphasie droite. (Fischer's exact test, p>0.05). Malgré la petite taille de notre cohorte de patients, ces résultats suggèrent une augmentation des corrélations anatomocliniques atypiques lors d'une représentation du langage dans l'hémisphère droit, surtout chez les patients non droitiers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose of reviewIn bladder cancer, discrimination between benign and malignant tissue may remain tricky with current endoscopic tools. On the basis of our recent experience with high-magnification cystoscopy, compared with other tools such as optical coherence tomography or confocal laser endomicroscopy, it is suggested here that this discrimination may well be feasible endoscopically. The clinical potential of these systems that are being developed as complementary tools to the current endoscopic equipment is reviewed.Recent findingsAt present, white-light cystoscopy, either assisted by fluorescence cystoscopy or narrow-band imaging, is proposed for the global cystoscopic examination of bladder cancer patients. Both techniques compete to help to reduce the recurrence rate by improving exophytic tumor detection, and the extent of carcinoma in situ and high-grade dysplasia. All of which are important prognosis factors for disease progression. In addition, recent findings on neoangiogenesis that accompanies early stage bladder cancer show that this may also be an important observable switch in bladder cancerogenesis, as it is found very early in tumor development. The high magnification cystoscopy as a complementary tool to fluorescence cystoscopy allows classification of the vessel patterns on fluorescence positive sites, and thus facilitates the discrimination between cancerous and noncancerous lesions. This information may be useful to reduce the false positive rate of fluorescence cystoscopy.SummaryEmerging technologies aiming at a real-time in-situ discrimination between benign and malignant tissue during endoscopic bladder exploration is a promising development for the monitoring of bladder cancer patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Currently, the most widely used criteria for assessing response to therapy in high-grade gliomas are based on two-dimensional tumor measurements on computed tomography (CT) or magnetic resonance imaging (MRI), in conjunction with clinical assessment and corticosteroid dose (the Macdonald Criteria). It is increasingly apparent that there are significant limitations to these criteria, which only address the contrast-enhancing component of the tumor. For example, chemoradiotherapy for newly diagnosed glioblastomas results in transient increase in tumor enhancement (pseudoprogression) in 20% to 30% of patients, which is difficult to differentiate from true tumor progression. Antiangiogenic agents produce high radiographic response rates, as defined by a rapid decrease in contrast enhancement on CT/MRI that occurs within days of initiation of treatment and that is partly a result of reduced vascular permeability to contrast agents rather than a true antitumor effect. In addition, a subset of patients treated with antiangiogenic agents develop tumor recurrence characterized by an increase in the nonenhancing component depicted on T2-weighted/fluid-attenuated inversion recovery sequences. The recognition that contrast enhancement is nonspecific and may not always be a true surrogate of tumor response and the need to account for the nonenhancing component of the tumor mandate that new criteria be developed and validated to permit accurate assessment of the efficacy of novel therapies. The Response Assessment in Neuro-Oncology Working Group is an international effort to develop new standardized response criteria for clinical trials in brain tumors. In this proposal, we present the recommendations for updated response criteria for high-grade gliomas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 35-year-old drug addict was found dead in a public toilet with a ruptured groin, which was later diagnosed to be a leaking pseudo-aneurysm. Investigation at the scene revealed impressive external hemorrhage related to a groin wound. Post-mortem computed tomography angiography demonstrated an aneurysm of the right femoral artery with leak of contrast liquid. Signs of blood loss were evident at autopsy, and histological examination revealed necrosis and rupture of the pseudo-aneurysm. Toxicological analyses were positive for methadone, cocaine, citalopram, and benzodiazepines. This is the first case report in the literature of a ruptured femoral pseudo-aneurysm with a post-mortem radiological diagnosis.