949 resultados para non-parametric technique


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the main features of finite element FE numerical model developed using the computer code FEMIX to predict the near-surface mounted NSM carbon-fiber-reinforced polymer CFRP rods shear repair contribution to corroded reinforced concrete RC beams. In the RC beams shear repaired with NSM technique, the Carbon Fibre Reinforced Polymer (CFRP) rods are placed inside pre-cut grooves onto the concrete cover of the RC beam’s lateral faces and are bonded to the concrete with high epoxy adhesive. Experimental and 3D numerical modelling results are presented in this paper in terms of load-deflection curves, failure modes and slip information of the tensile steel bars for 4 short corroded beams: two corroded beams (A1CL3-B and A1CL3-SB) and two control beams (A1T-B and A1T-SB), the beams noted with B were let repaired in bending only with NSM CFRP rods while the ones noted with SB were repaired in both bending and shear with NSM technique. The corrosion of the tensile steel bars and its effect on the shear capacity of the RC beams was discussed. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for non-shear repaired beams which failed in diagonal tension mode of failure and for shear-repaired beams which failed due to large flexural crack at the middle of the beams along with the concrete crushing, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents an experimental program to assess the tensile strain distribution along prestressed carbon fiber reinforced polymer (CFRP) reinforcement flexurally applied on the tensile surface of RC beams according to near surface mounted (NSM) technique. Moreover, the current study aims to propose an analytical formulation, with a design framework, for the prediction of distribution of CFRP tensile strain and bond shear stress and, additionally, the prestress transfer length. After demonstration the good predictive performance of the proposed analytical approach, parametric studies were carried out to analytically evaluate the influence of the main material properties, and CFRP and groove cross section on the distribution of the CFRP tensile strain and bond shear stress, and on the prestress transfer length. The proposed analytical approach can also predict the evolution of the prestress transfer length during the curing time of the adhesive by considering the variation of its elasticity modulus during this period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, hafnium aluminum oxide (HfAlO) thin films were deposited by ion beam sputtering deposition technique on Si substrate. The presence of oxygen vacancies in the HfAlOx layer deposited in oxygen deficient environment is evidenced from the photoluminescence spectra. Furthermore, HfAlO(oxygen rich)/HfAlOx(oxygen poor) bilayer structures exhibit multilevel resistive switching (RS), and the switching ratio becomes more prominent with increasing the HfAlO layer thickness. The bilayer structure with HfAlO/HfAlOx thickness of 30/40 nm displays the enhanced multilevel resistive switching characteristics, where the high resistance state/ intermediate resistance state (IRS) and IRS/low resistance state resistance ratios are 102 and 5 105 , respectively. The switching mechanisms in the bilayer structures were investigated by the temperature dependence of the three resistance states. This study revealed that the multilevel RS is attributed to the coupling of ionic conduction and the metallic conduction, being the first associated to the formation and rupture of conductive filaments related to oxygen vacancies and the second with the formation of a metallic filament. Moreover, the bilayer structures exhibit good endurance and stability in time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Boundary equilibrium bifurcations in piecewise smooth discontinuous systems are characterized by the collision of an equilibrium point with the discontinuity surface. Generically, these bifurcations are of codimension one, but there are scenarios where the phenomenon can be of higher codimension. Here, the possible collision of a non-hyperbolic equilibrium with the boundary in a two-parameter framework and the nonlinear phenomena associated with such collision are considered. By dealing with planar discontinuous (Filippov) systems, some of such phenomena are pointed out through specific representative cases. A methodology for obtaining the corresponding bi-parametric bifurcation sets is developed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La douleur est fréquente en milieu de soins intensifs et sa gestion est l'une des missions des infirmières. Son évaluation est une prémisse indispensable à son soulagement. Cependant lorsque le patient est incapable de signaler sa douleur, les infirmières doivent se baser sur des signes externes pour l'évaluer. Les guides de bonne pratique recommandent chez les personnes non communicantes l'usage d'un instrument validé pour la population donnée et basé sur l'observation des comportements. A l'heure actuelle, les instruments d'évaluation de la douleur disponibles ne sont que partiellement adaptés aux personnes cérébrolésées dans la mesure où ces personnes présentent des comportements qui leur sont spécifiques. C'est pourquoi, cette étude vise à identifier, décrire et valider des indicateurs, et des descripteurs, de la douleur chez les personnes cérébrolésées. Un devis d'étude mixte multiphase avec une dominante quantitative a été choisi pour cette étude. Une première phase consistait à identifier des indicateurs et des descripteurs de la douleur chez les personnes cérébrolésées non communicantes aux soins intensifs en combinant trois sources de données : une revue intégrative des écrits, une démarche consultative utilisant la technique du groupe nominal auprès de 18 cliniciens expérimentés (6 médecins et 12 infirmières) et les résultats d'une étude pilote observationnelle réalisée auprès de 10 traumatisés crâniens. Les résultats ont permis d'identifier 6 indicateurs et 47 descripteurs comportementaux, vocaux et physiologiques susceptibles d'être inclus dans un instrument d'évaluation de la douleur destiné aux personnes cérébrolésées non- communicantes aux soins intensifs. Une deuxième phase séquentielle vérifiait les propriétés psychométriques des indicateurs et des descripteurs préalablement identifiés. La validation de contenu a été testée auprès de 10 experts cliniques et 4 experts scientifiques à l'aide d'un questionnaire structuré qui cherchait à évaluer la pertinence et la clarté/compréhensibilité de chaque descripteur. Cette démarche a permis de sélectionner 33 des 47 descripteurs et valider 6 indicateurs. Dans un deuxième temps, les propriétés psychométriques de ces indicateurs et descripteurs ont été étudiés au repos, lors de stimulation non nociceptive et lors d'une stimulation nociceptive (la latéralisation du patient) auprès de 116 personnes cérébrolésées aux soins intensifs hospitalisées dans deux centres hospitaliers universitaires. Les résultats montrent d'importantes variations dans les descripteurs observés lors de stimulation nociceptive probablement dues à l'hétérogénéité des patients au niveau de leur état de conscience. Dix descripteurs ont été éliminés, car leur fréquence lors de la stimulation nociceptive était inférieure à 5% ou leur fiabilité insuffisante. Les descripteurs physiologiques ont tous été supprimés en raison de leur faible variabilité et d'une fiabilité inter juge problématique. Les résultats montrent que la validité concomitante, c'est-à-dire la corrélation entre l'auto- évaluation du patient et les mesures réalisées avec les descripteurs, est satisfaisante lors de stimulation nociceptive {rs=0,527, p=0,003, n=30). Par contre la validité convergente, qui vérifiait l'association entre l'évaluation de la douleur par l'infirmière en charge du patient et les mesures réalisés avec les descripteurs, ainsi que la validité divergente, qui vérifiait si les indicateurs discriminent entre la stimulation nociceptive et le repos, mettent en évidence des résultats variables en fonction de l'état de conscience des patients. Ces résultats soulignent la nécessité d'étudier les descripteurs de la douleur chez des patients cérébrolésés en fonction du niveau de conscience et de considérer l'hétérogénéité de cette population dans la conception d'un instrument d'évaluation de la douleur pour les personnes cérébrolésées non communicantes aux soins intensifs. - Pain is frequent in the intensive care unit (ICU) and its management is a major issue for nurses. The assessment of pain is a prerequisite for appropriate pain management. However, pain assessment is difficult when patients are unable to communicate about their experience and nurses have to base their evaluation on external signs. Clinical practice guidelines highlight the need to use behavioral scales that have been validated for nonverbal patients. Current behavioral pain tools for ICU patients unable to communicate may not be appropriate for nonverbal brain-injured ICU patients, as they demonstrate specific responses to pain. This study aimed to identify, describe and validate pain indicators and descriptors in brain-injured ICU patients. A mixed multiphase method design with a quantitative dominant was chosen for this study. The first phase aimed to identify indicators and descriptors of pain for nonverbal brain- injured ICU patients using data from three sources: an integrative literature review, a consultation using the nominal group technique with 18 experienced clinicians (12 nurses and 6 physicians) and the results of an observational pilot study with 10 traumatic brain injured patients. The results of this first phase identified 6 indicators and 47 behavioral, vocal and physiological descriptors of pain that could be included in a pain assessment tool for this population. The sequential phase two tested the psychometric properties of the list of previously identified indicators and descriptors. Content validity was tested with 10 clinical and 4 scientific experts for pertinence and comprehensibility using a structured questionnaire. This process resulted in 33 descriptors to be selected out of 47 previously identified, and six validated indicators. Then, the psychometric properties of the descriptors and indicators were tested at rest, during non nociceptive stimulation and nociceptive stimulation (turning) in a sample of 116 brain-injured ICLI patients who were hospitalized in two university centers. Results showed important variations in the descriptors observed during the nociceptive stimulation, probably due to the heterogeneity of patients' level of consciousness. Ten descriptors were excluded, as they were observed less than 5% of the time or their reliability was insufficient. All physiologic descriptors were deleted as they showed little variability and inter observer reliability was lacking. Concomitant validity, testing the association between patients' self report of pain and measures performed using the descriptors, was acceptable during nociceptive stimulation (rs=0,527, p=0,003, n=30). However, convergent validity ( testing for an association between the nurses' pain assessment and measures done with descriptors) and divergent validity (testing for the ability of the indicators to discriminate between rest and a nociceptive stimulation) varied according to the level of consciousness These results highlight the need to study pain descriptors in brain-injured patients with different level of consciousness and to take into account the heterogeneity of this population forthe conception of a pain assessment tool for nonverbal brain-injured ICU patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Accurate placement of an external ventricular drain (EVD) for the treatment of hydrocephalus is of paramount importance for its functionality and in order to minimize morbidity and complications. The aim of this study was to compare two different drain insertion assistance tools with the traditional free-hand anatomical landmark method, and to measure efficacy, safety and precision. METHODS: Ten cadaver heads were prepared by opening large bone windows centered on Kocher's points on both sides. Nineteen physicians, divided in two groups (trainees and board certified neurosurgeons) performed EVD insertions. The target for the ventricular drain tip was the ipsilateral foramen of Monro. Each participant inserted the external ventricular catheter in three different ways: 1) free-hand by anatomical landmarks, 2) neuronavigation-assisted (NN), and 3) XperCT-guided (XCT). The number of ventricular hits and dangerous trajectories; time to proceed; radiation exposure of patients and physicians; distance of the catheter tip to target and size of deviations projected in the orthogonal plans were measured and compared. RESULTS: Insertion using XCT increased the probability of ventricular puncture from 69.2 to 90.2 % (p = 0.02). Non-assisted placements were significantly less precise (catheter tip to target distance 14.3 ± 7.4 mm versus 9.6 ± 7.2 mm, p = 0.0003). The insertion time to proceed increased from 3.04 ± 2.06 min. to 7.3 ± 3.6 min. (p < 0.001). The X-ray exposure for XCT was 32.23 mSv, but could be reduced to 13.9 mSv if patients were initially imaged in the hybrid-operating suite. No supplementary radiation exposure is needed for NN if patients are imaged according to a navigation protocol initially. CONCLUSION: This ex vivo study demonstrates a significantly improved accuracy and safety using either NN or XCT-assisted methods. Therefore, efforts should be undertaken to implement these new technologies into daily clinical practice. However, the accuracy versus urgency of an EVD placement has to be balanced, as the image-guided insertion technique will implicate a longer preparation time due to a specific image acquisition and trajectory planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, a number of cases of smuggling dissolved cocaine in wine bottles have been reported. The aim of the present study was to determine whether cocaine dissolved in wine can be detected by proton magnetic resonance spectroscopy ((1) H MRS) on a standard clinical MR scanner, in intact (i.e. unopened) wine bottles. (1) H MRS experiments were performed with a 3 Tesla clinical scanner on wine phantoms with or without cocaine contamination. The aromatic protons of cocaine displayed resonance peaks in the 7-8 ppm region of the spectrum, where no overlapping resonances of wine were present. Additional cocaine resonances were detected in the 2-3 ppm region of the spectrum, between the resonances of ethanol and other wine constituents. Detection of cocaine in wine (at 5 mM, i.e. ∼1.5 g/L) was feasible in a scan time of 1 min. We conclude that dissolved cocaine can be detected in intact wine bottles, on a standard clinical MR scanner. Thus, (1) H MRS is the technique of choice to examine this type of suspicious cargo, since it allows for a non-destructive and rapid content characterization. Copyright © 2010 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Mediastinal lymph-node dissection was compared to systematic mediastinal lymph-node sampling in patients undergoing complete resection for non-small cell lung cancer with respect to morbidity, duration of chest tube drainage and hospitalization, survival, disease-free survival, and site of recurrence. METHODS: A consecutive series of one hundred patients with non-small-cell lung cancer, clinical stage T1-3 N0-1 after standardized staging, was divided into two groups of 50 patients each, according to the technique of intraoperative mediastinal lymph-node assessment (dissection versus sampling). Mediastinal lymph-node dissection consisted of removal of all lymphatic tissues within defined anatomic landmarks of stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side according to the classification of the American Thoracic Society. Systematic mediastinal lymph-node sampling consisted of harvesting of one or more representative lymph nodes from stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side. RESULTS: All patients had complete resection. A mean follow-up time of 89 months was achieved in 92 patients. The two groups of patients were comparable with respect to age, gender, performance status, tumor stage, histology, extent of lung resection, and follow-up time. No significant difference was found between both groups regarding the duration of chest tube drainage, hospitalization, and morbidity. However, dissection required a longer operation time than sampling (179 +/- 38 min versus 149 +/- 37 min, p < 0.001). There was no significant difference in overall survival between the two groups; however, patients with stage I disease had a significantly longer disease-free survival after dissection than after sampling (60.2 +/- 7 versus 44.8 +/- 8 months, p < 0.03). Local recurrence was significantly higher after sampling than after dissection in patients with stage I tumor (12.5% versus 45%, p = 0.02) and in patients with nodal tumor negative mediastinum (N0/N1 disease) (46% versus 13%, p = 0.004). CONCLUSION: Our results suggest that mediastinal lymph-node dissection may provide a longer disease-free survival in stage I non-small cell lung cancer and, most importantly, a better local tumor control than mediastinal lymph-node sampling after complete resection for N0/N1 disease without leading to increased morbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Hirschsprung disease (HSCR) is a congenital malformation of the hindgut produced by a disruption in neural crest cell migration during embryonic development. HSCR has a complex genetic etiology and mutations in several genes, mainly the RET proto-oncogene, have been related to the disease. There is a clear predominance of missense/nonsense mutations in these genes whereas copy number variations (CNVs) have been seldom described, probably due to the limitations of conventional techniques usually employed for mutational analysis. METHODS In this study we have aimed to analyze the presence of CNVs in some HSCR genes (RET, EDN3, GDNF and ZFHX1B) using the Multiple Ligation-dependent Probe Amplification (MLPA) approach. RESULTS Two alterations in the MLPA profiles of RET and EDN3 were detected, but a detailed inspection showed that the decrease in the corresponding dosages were due to point mutations affecting the hybridization probes regions. CONCLUSION Our results indicate that CNVs of the gene coding regions analyzed here are not a common molecular cause of Hirschsprung disease. However, further studies are required to determine the presence of CNVs affecting non-coding regulatory regions, as well as other candidate genes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Non cephalic presentation in childbirth involves various risks to both the mother and the foetus. The incidence in Spain is 3.8% of all full-term pregnancies. The most common technique used to end the gestation in cases of non cephalic presentation is that of caesarian section, and although it provokes a lower rate of morbi-mortality than does vaginal delivery in such situations, there remains the possibility of traumatic injury to the foetal head and neck, while maternal morbidity is also increased. The application of heat (moxibustion) to an acupuncture point, in order to correct non cephalic presentation, has been practised in China since ancient times, but as yet there is insufficient evidence of its real effectiveness. METHODS/DESIGN The experimental design consists of a multi-centre randomised controlled trial with three parallel arms, used to compare real moxibustion, sham moxibustion and the natural course of events, among pregnant women with a non cephalic presentation and a gestational duration of 33-35 weeks (estimated by echography). The participants in the trial will be blinded to both interventions. The results obtained will be analyzed by professionals, blinded with respect to the allocation to the different types of intervention. In addition, we intend to carry out a economic analysis. DISCUSSION This trial will contribute to the development of evidence concerning moxibustion in the correction of non cephalic presentations. The primary outcome variable is the proportion of cephalic presentations at term. As secondary outcomes, we will evaluate the proportion of cephalic presentations at week 38 of gestation, determined by echography, together with the safety of the technique, the specificity of moxibustion and the control of the blinding process. This study has been funded by the Health Ministry of the Andalusian Regional Government. TRIAL REGISTRATION Current Controlled Trials ISRCTN10634508.