946 resultados para medical imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Over the past decade, molecular imaging has played a key role in the progression of drug delivery platforms from concept to commercialisation. Of the molecular imaging techniques commonly utilised, positron emission tomography (PET) can yield a breadth of information not easily accessible by other methodologies and when combined with other complementary imaging modalities, is a powerful tool for pre- and clinical development of therapeutics. However, very little research has focussed on the information available from complimentary imaging modalities. This paper reports on the data-rich methodologies of contrast enhanced PET/CT and PET/MRI for probing efficacy of polymer drug delivery platforms. Results The information available from an ExiTron nano 6000 contrast enhanced PET/CT and a gadolinium (Gd) enhanced PET/MRI image of a 64Cu labeled HBP in the same mouse was qualitatively compared. Conclusions Gd contrast enhanced PET/MRI offers a powerful methodology for investigating the distribution of polymer drug delivery platforms in vivo and throughout a tumour volume. Furthermore, information about depth of penetration away from primary blood vessels can be gleaned, potentially leading to development of more efficacious delivery vehicles for clinical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular imaging is utilised in modern medicine to aid in the diagnosis and treatment of disease by allowing its spatiotemporal state to be examined in vivo. This study focuses on the development of novel multimodal molecular imaging agents based on hyperbranched polymers that combine the complementary capabilities of optical fluorescence imaging and positron emission tomography-computed tomography (PET/CT) into one construct. RAFT-mediated polymerisation was used to prepare two hydrophilic hyperbranched polymers that were differentiated by their size and level of branching. The multiple functional end-groups facilitated covalent attachment of both near infrared fluorescent dyes for optical imaging, as well as a copper chelator allowing binding of 64Cu as a PET radio nuclei. In vivo multimodal imaging of mice using PET/CT and planar optical imaging was first used to assess the biodistribution of the polymeric materials and it was shown that the larger and more branched polymer had a significantly longer circulation time. The larger constructs were also shown to exhibit enhanced accumulation in solid tumours in a murine B16 melanoma model. Importantly, it was demonstrated that the PET modality gave rise to high sensitivity immediately after injection of the agent, while the optical modality facilitated extended longitudinal studies, thus highlighting how the complementary capabilities of the molecular imaging agents can be useful for studying various diseases, including cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymers open up new possibilities in the field of molecular imaging, allowing sensitive and robust agents that can be imaged over long periods of time. This review highlights some recent advances in polymeric molecular imaging agents in both (pre)clinical and emerging applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Public submission # 247 to the McKeon Review. The submission addresses the terms of reference on: How can we optimise translation of health and medical research into better health and wellbeing? (Terms of Reference 4, 8, 9, 10 and 11)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone diseases such as rickets and osteoporosis cause significant reduction in bone quantity and quality, which leads to mechanical abnormalities. However, the precise ultrastructural mechanism by which altered bone quality affects mechanical properties is not clearly understood. Here we demonstrate the functional link between altered bone quality (reduced mineralization) and abnormal fibrillar-level mechanics using a novel, real-time synchrotron X-ray nanomechanical imaging method to study a mouse model with rickets due to reduced extrafibrillar mineralization. A previously unreported N-ethyl-N-nitrosourea (ENU) mouse model for hypophosphatemic rickets (Hpr), as a result of missense Trp314Arg mutation of the phosphate regulating gene with homologies to endopeptidase on the X chromosome (Phex) and with features consistent with X-linked hypophosphatemic rickets (XLHR) in man, was investigated using in situ synchrotron small angle X-ray scattering to measure real-time changes in axial periodicity of the nanoscale mineralized fibrils in bone during tensile loading. These determine nanomechanical parameters including fibril elastic modulus and maximum fibril strain. Mineral content was estimated using backscattered electron imaging. A significant reduction of effective fibril modulus and enhancement of maximum fibril strain was found in Hpr mice. Effective fibril modulus and maximum fibril strain in the elastic region increased consistently with age in Hpr and wild-type mice. However, the mean mineral content was ∼21% lower in Hpr mice and was more heterogeneous in its distribution. Our results are consistent with a nanostructural mechanism in which incompletely mineralized fibrils show greater extensibility and lower stiffness, leading to macroscopic outcomes such as greater bone flexibility. Our study demonstrates the value of in situ X-ray nanomechanical imaging in linking the alterations in bone nanostructure to nanoscale mechanical deterioration in a metabolic bone disease. Copyright

Relevância:

20.00% 20.00%

Publicador:

Resumo:

• As part of the 3E program, we conducted a systematic literature review and gathered consensus from 23 practising Australian rheumatologists to develop guidelines for early identification of ankylosing spondylitis and specialist referral. • In three rounds of break-out sessions followed by discussion and voting, the specialist panel addressed three questions related to diagnosis of ankylosing spondylitis: In individuals with back pain, what are the early clinical features that suggest ankylosing spondylitis? How useful is imaging in identifying early ankylosing spondylitis? Based on which clinical features should a general practitioner refer a patient to a rheumatologist for further evaluation? • The panel agreed on six recommendations related to the three questions: 1a. Early clinical features to suggest ankylosing spondylitis include inflammatory back pain and age at symptom onset < 45 years. 1b. The absence of symptomatic response to an appropriate course of non-steroidal anti-inflammatory drugs makes the diagnosis of ankylosing spondylitis less likely. 1c. Raised inflammatory markers are supportive, but their absence does not rule out the diagnosis of ankylosing spondylitis. 2a. Despite low sensitivity to detect changes of early ankylosing spondylitis, plain radiographs of the pelvis and spine are appropriate initial imaging techniques. 2b. Magnetic resonance imaging is a useful imaging modality for detecting early changes of ankylosing spondylitis. 3. Individuals with inflammatory back pain should be referred to a rheumatologist for further evaluation. • Effective dissemination and implementation of these recommendations are important to standardise the approach to early diagnosis of ankylosing spondylitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Companies such as NeuroSky and Emotiv Systems are selling non-medical EEG devices for human computer interaction. These devices are significantly more affordable than their medical counterparts, and are mainly used to measure levels of engagement, focus, relaxation and stress. This information is sought after for marketing research and games. However, these EEG devices have the potential to enable users to interact with their surrounding environment using thoughts only, without activating any muscles. In this paper, we present preliminary results that demonstrate that despite reduced voltage and time sensitivity compared to medical-grade EEG systems, the quality of the signals of the Emotiv EPOC neuroheadset is sufficiently good in allowing discrimina tion between imaging events. We collected streams of EEG raw data and trained different types of classifiers to discriminate between three states (rest and two imaging events). We achieved a generalisation error of less than 2% for two types of non-linear classifiers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under the civil liability legislation enacted in most Australian jurisdictions, factual causation will be established if, on the balance of probabilities, the claimant can prove that the defendant's negligence was 'a necessary condition of the occurrence of the [claimant's] harm'. Causation will then be satisfied by showing that the harm would not have occurred 'but for' the defendant's breach of their duty of care. However, in an exceptional or appropriate case, sub-section 2 of the legislation provides that if the 'but for' test is not met, factual causation may instead be determined in accordance with other 'established principles'. In such a case, 'the court is to consider (amongst other relevant things) whether or not and why responsibility for the harm should be imposed' on the negligent party.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a new method for the growth of reduced graphene oxide (rGO) on the 316L alloy of stainless steel (SS) and its relevance for biomedical applications. We demonstrate that electrochemical etching increases the concentration of metallic species on the surface and enables the growth of rGO. This result is supported through a combination of Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), density functional theory (DFT) calculations and static water contact angle measurements. Raman spectroscopy identifies the G and D bands for oxidized species of graphene at 1595 cm(-1) and 1350 cm(-1), respectively, and gives an ID/IG ratio of 1.2, indicating a moderate degree of oxidation. XPS shows -OH and -COOH groups in the rGO stoichiometry and static contact angle measurements confirm the wettability of rGO. SEM and AFM measurements were performed on different substrates before and after coronene treatment to confirm rGO growth. Cell viability studies reveal that these rGO coatings do not have toxic effects on mammalian cells, making this material suitable for biomedical and biotechnological applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holography is the direct recording of holograms using a CCD camera and is an alternative to the use of a film or a plate. In this communication in-line digital holographic microscopy has been explored for its application in particle imaging in 3D. Holograms of particles of about 10 mu m size have been digitally reconstructed. Digital focusing was done to image the particles in different planes along the depth of focus. Digital holographic particle imaging results were compared with conventional optical microscope imaging. A methodology for dynamic analysis of microparticles in 3D using in-line digital holography has been proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A defect-selective photothermal imaging system for the diagnostics of optical coatings is demonstrated. The instrument has been optimized for pump and probe parameters, detector performance, and signal processing algorithm. The imager is capable of mapping purely optical or thermal defects efficiently in coatings of low damage threshold and low absorbance. Detailed mapping of minor inhomogeneities at low pump power has been achieved through the simultaneous action of a low-noise fiber optic photothermal beam defection sensor and a common-mode-rejection demodulation (CMRD) technique. The linearity and sensitivity of the sensor have been examined theoretically and experimentally, and the signal to noise ratio improvement factor is found to be about 110 compared to a conventional bicell photodiode. The scanner is so designed that mapping of static or shock sensitive samples is possible. In the case of a sample with absolute absorptance of 3.8 x 10(-4), a change in absorptance of about 0.005 x 10(-4) has been detected without ambiguity, ensuring a contrast parameter of 760. This is about 1085% improvement over the conventional approach containing a bicell photodiode, at the same pump power. The merits of the system have been demonstrated by mapping two intentionally created damage sites in a MgF2 coating on fused silica at different excitation powers. Amplitude and phase maps were recorded for thermally thin and thick cases, and the results are compared to demonstrate a case which, in conventional imaging, would lead to a deceptive conclusion regarding the type and location of the damage. Also, a residual damage profile created by long term irradiation with high pump power density has been depicted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a medical negligence context, and under the causation provisions enacted pursuant to Civil Liability Legislation in most Australian jurisdictions, the normative concept of “scope of liability” requires a consideration of whether or not and why a medical practitioner should be responsible for a patient’s harm. As such, it places a limit on the extent to which practitioners are deemed liable for a breach of the duty of care owed by them, in circumstances where a legal factual connection between that breach and the causation of a patient’s harm has already been shown. It has been said that a determination of causation requires ‘the identification and articulation of an evaluative judgement by reference to “the purposes and policy of the relevant part of the law”’: Wallace v Kam (2013) 297 ALR 383, 388. Accordingly, one of the normative factors falling within scope of liability is an examination of the content and purpose of the rule or duty of care violated – that is, its underlying policy and whether this supports an attribution of legal responsibility upon a practitioner. In this context, and with reference to recent jurisprudence, this paper considers: the policy relevant to a practitioner’s duty of care in each of the areas of diagnosis, treatment and advice; how this has been used to determine an appropriate scope of liability for the purpose of the causation inquiry in medical negligence claims; and whether such an approach is problematic for medical standards or decision-making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study by means of experiments and Monte Carlo simulations, the scattering of light in random media, to determine the distance up to which photons travel along almost undeviated paths within a scattering medium, and are therefore capable of casting a shadow of an opaque inclusion embedded within the medium. Such photons are isolated by polarisation discrimination wherein the plane of linear polarisation of the input light is continuously rotated and the polarisation preserving component of the emerging light is extracted by means of a Fourier transform. This technique is a software implementation of lock-in detection. We find that images may be recovered to a depth far in excess of that predicted by the diffusion theory of photon propagation. To understand our experimental results, we perform Monte Carlo simulations to model the random walk behaviour of the multiply scattered photons. We present a. new definition of a diffusing photon in terms of the memory of its initial direction of propagation, which we then quantify in terms of an angular correlation function. This redefinition yields the penetration depth of the polarisation preserving photons. Based on these results, we have formulated a model to understand shadow formation in a turbid medium, the predictions of which are in good agreement with our experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-Raman imaging of the distribution of Te precipitates in CdZnTe crystals in different phases is reported. For the normal phase of Te precipitates, the Raman modes appear centered around 121(A1), 141(E)/TO(CdTe) cm−1 and a weak mode around 92(E) cm−1 in CdZnTe indicating the presence of trigonal lattice of Te. Under high pressure phase, the volume of Te precipitates collapses, giving more bond energy resulting in the blueshift of the corresponding Raman bands. Also, the spatial distribution of the area ratio of 121 to 141 cm−1 Raman modes is used to quantify Te precipitates. Further, near-infrared microscopy images support these results.