989 resultados para magnetic aging stress
Resumo:
Exogenous administration of glucocorticoids is a widely used and efficient tool to investigate the effects of elevated concentrations of these hormones in field studies. Because the effects of corticosterone are dose and duration-dependent, the exact course of plasma corticosterone levels after exogenous administration needs to be known. We tested the performance of self-degradable corticosterone pellets (implanted under the skin) in elevating plasma corticosterone levels. We monitored baseline (sampled within 3min after capture) total corticosterone levels and investigated potential interactions with corticosteroid-binding-globulin (CBG) capacity and the endogenous corticosterone response to handling in Eurasian kestrel Falco tinnunculus and barn owl Tyto alba nestlings. Corticosterone pellets designed for a 7-day-release in rodents elevated circulating baseline total corticosterone during only 2-3 days compared to placebo-nestlings. Highest levels occurred 1-2days after implantation and levels decreased strongly thereafter. CBG capacity was also increased, resulting in a smaller, but still significant, increase in baseline free corticosterone levels. The release of endogenous corticosterone as a response to handling was strong in placebo-nestlings, but absent 2 and 8 days after corticosterone pellet implantation. This indicates a potential shut-down of the hypothalamo-pituitary-adrenal axis after the 2-3 days of elevated baseline corticosterone levels. 20 days after pellet implantation, the endogenous corticosterone response to handling of nestlings implanted with corticosterone pellets attained similar levels as in placebo-nestlings. Self-degradable pellets proved to be an efficient tool to artificially elevate circulating baseline corticosterone especially in field studies, requiring only one intervention. The resulting peak-like elevation of circulating corticosterone, the concomitant elevation of CBG capacity, and the absence of an endogenous corticosterone response to an acute stressor have to be taken into account.
Resumo:
RésuméIntroduction : Le travail de thèse est un article publié dans le journal « Fertility & Sterility » s'intitulant « Birth records from Swiss married couples analyzed over the past 35 years reveal an aging of first-time mothers by 5.1 years while the interpregnancy interval has shortened ».Méthodes : Les données concernant l'âge auquel les femmes mariées donnaient naissance ont été obtenues de l'Office fédéral de la statistique. Nous avons examiné la période allant de 1969 à 2006. Cet intervalle de temps choisi nous a permis de prendre en considération un total de 2'716'370 naissances. L'âge moyen des parturientes à la naissance de leur 1er, 2ème et 3ème enfant a été calculé pour chaque année à l'aide du logiciel Excel. Grâce à ces données on a pu obtenir les intervalles inter-gestationnels théoriques entre le 1er et 2ème enfant, ainsi qu'entre le 2ème et 3ème enfant.Résultats : Nous pouvons constater que l'intervalle inter-gestationnel théorique entre la première et la deuxième grossesse était de 23.2 mois en 1969 et passait à 13.0 mois en 2006. L'intervalle compris entre la deuxième et la troisième grossesse passait de 22.4 mois en 1969 à 7.9 mois en 2006. Notre analyse suggère donc que c'est le facteur social qui exerce un effet plus important que le facteur biologique sur les intervalles inter-gestationnels, car ces intervalles diminuaient malgré l'augmentation de l'âge des mères à la naissance.
Resumo:
Cardiovascular magnetic resonance (CMR) is a rapidly emerging non-invasive imaging technique free of X-Ray and offers higher spatial resolution than alternative forms of cardiac imaging for the assessment of left ventricular (LV) anatomy, function, and viability due to the unique capability of myocardial tissue characterization after gadolinium-chelates contrast administration. This imaging technique has clinical utility over a broad spectrum of heart diseases: ranging from ischaemic to non ischaemic aetiologies. Cardiomyopathies (CMP) are a heterogeneous group of diseases of the myocardium associated with architectural abnormalities and mechanical dysfunction. CMR can help excluding coronary artery disease and can provide positive diagnostic features for several CMP resulted in better diagnosis and management, Leading to improvements in mortality.
Resumo:
En aquest projecte es presenta la realització d’un sistema d’assaig de la corrosió sota tensió (stress corrosion cracking, SCC) i un estudi de l’efecte de l’SCC sobre dos acers d’eina per matrius d’estampació en calent. L’SCC és la formació i propagació d’esquerdes en un material degut a la interacció de tres factors: un medi corrosiu, un material susceptible i una tensió estàtica aplicada. Aquestes esquerdes són difícils de detectar i poden provocar fallades catastròfiques inesperades i, en concret, s’ha detectat aquest fenomen en matrius refrigerades d’estampació en calent. Es pretén dissenyar i construir un dispositiu d’assaig SCC per tal d’utilitzar-lo per l’estudi dels materials 1.2367 i 1.2343 en condicions d’aigua de xarxa, aigua destil·lada i inhibidor. Aquests assaigs es realitzen a les temperatures de 40 i 80ºC ja que un estudi previ ha simulat les condicions de temperatura als canals de refrigeració de les matrius d’estampació en calent i s’ha vist que aquestes són les temperatures assolides. La raó d’estudiar aquests materials és perquè són dos acers d’eina per treball en calent convencionals, usats en l’àmbit de les matrius refrigerades d’estampació en calent i en general en processos de conformat en calent (forja, moldeig). S’estudia el comportament a tracció d’aquests materials en aquestes condicions comparant-lo amb el mateix assaig però en condicions en aire, i s’avaluen les diferències en la tensió màxima, la ductilitat, el mecanisme de fractura o l’esquerdament sofert. Es fa un estudi fractogràfic de les mostres mitjançant microscòpia electrònica de rastreig (SEM) i un estudi de les superfícies laterals i del secondary cracking mitjançant microscòpia òptica. Es comparen els diferents resultats obtinguts i es determina en quines condicions s’ha desenvolupat SCC i en quines no, en quina intensitat i quines opcions hi ha per evitar-lo.
Resumo:
BACKGROUND: The purpose of this prospective study was to perform a head-to-head comparison of the two methods most frequently used for evaluation of carotid plaque characteristics: Multi-detector Computed Tomography Angiography (MDCTA) and black-blood 3 T-cardiovascular magnetic resonance (bb-CMR) with respect to their ability to identify symptomatic carotid plaques. METHODS: 22 stroke unit patients with unilateral symptomatic carotid disease and >50% stenosis by duplex ultrasound underwent MDCTA and bb-CMR (TOF, pre- and post-contrast fsT1w-, and fsT2w- sequences) within 15 days of symptom onset. Both symptomatic and contralateral asymptomatic sides were evaluated. By bb-CMR, plaque morphology, composition and prevalence of complicated AHA type VI lesions (AHA-LT6) were evaluated. By MDCTA, plaque type (non-calcified, mixed, calcified), plaque density in HU and presence of ulceration and/or thrombus were evaluated. Sensitivity (SE), specificity (SP), positive and negative predictive value (PPV, NPV) were calculated using a 2-by-2-table. RESULTS: To distinguish between symptomatic and asymptomatic plaques AHA-LT6 was the best CMR variable and presence / absence of plaque ulceration was the best CT variable, resulting in a SE, SP, PPV and NPV of 80%, 80%, 80% and 80% for AHA-LT6 as assessed by bb-CMR and 40%, 95%, 89% and 61% for plaque ulceration as assessed by MDCTA. The combined SE, SP, PPV and NPV of bb-CMR and MDCTA was 85%, 75%, 77% and 83%, respectively. CONCLUSIONS: Bb-CMR is superior to MDCTA at identifying symptomatic carotid plaques, while MDCTA offers high specificity at the cost of low sensitivity. Results were only slightly improved over bb-CMR alone when combining both techniques.
Resumo:
Despite advances in both prevention and treatment, cardiovascular disease remains the leading cause of morbidity and mortality in the United States. The current gold standard for the diagnosis of coronary artery disease is the x-ray coronary angiogram, which is both costly and associated with a small risk of morbidity. More than 1 million Americans are referred for this test annually, and despite the availability of numerous noninvasive tests to identify patients with coronary artery disease, > or =35% of patients referred for this test are found not to have disease. It therefore would be beneficial to use a noninvasive test to allow the presence of coronary atherosclerosis to be determined directly. Coronary magnetic resonance angiography, a technique that is aimed at establishing a noninvasive test for the assessment of significant coronary stenoses, obviates the risks of patient exposure to radiation of x-ray angiography and therefore represents a major step forward in diagnostic cardiology.
Resumo:
We examine whether and how main central banks responded to episodes of financial stress over the last three decades. We employ a new methodology for monetary policy rules estimation, which allows for time-varying response coefficients as well as corrects for endogeneity. This flexible framework applied to the U.S., U.K., Australia, Canada and Sweden together with a new financial stress dataset developed by the International Monetary Fund allows not only testing whether the central banks responded to financial stress but also detects the periods and type of stress that were the most worrying for monetary authorities and to quantify the intensity of policy response. Our findings suggest that central banks often change policy
Resumo:
INTRODUCTION: We set out to determine if insertion of a retropubic tension-free vaginal tape (TVT) sling at the time of pelvic organ prolapse surgery improves continence outcomes in women with pre-operative occult stress incontinence (OSI) or asymptomatic urodynamic stress incontinence (USI). METHODS: We conducted a randomised controlled study of prolapse surgery with or without a TVT midurethral sling. The pre- and post-operative assessment at 6 months included history, physical examination and urodynamic testing. Quality of life (QOL) and treatment success was assessed with the UDI-6 SF, IIQ-7 SF and a numerical success score. The primary outcome was symptomatic stress urinary incontinence (SUI) requiring continence surgery (TVT) at 6 months. Long-term follow-up continued to a minimum of 24 months. Secondary outcomes were quality of life parameters. RESULTS: Eighty women received prolapse surgery alone (n = 43) or prolapse surgery with concurrent TVT (n = 37). Six months following prolapse surgery 3 out of 43 (7 %) patients in the no TVT group requested sling surgery compared with 0 out of 37 (0 %) in the TVT group (ARR 7 % [95 %CI: 3 to 19 %], p = 0.11). After 24 months there was one further participant in the no TVT group who received a TVT for treatment of SUI compared with none in the TVT group (4 out of 43, 9.3 % versus 0 out of 37; ARR 9.3 % [95 %CI: -1 to 22 %], p = 0.06). Both groups showed improvement in QOL difference scores for within-group analysis, without difference between groups. CONCLUSION: These results support a policy that routine insertion of a sling in women with OSI at the time of prolapse repair is questionable and should be subject to shared decision-making between clinician and patient.
Resumo:
Although stress has been a longstanding issue in organizations and management studies, it has never been studied in relation to Public Service Motivation. This article therefore aims to integrate PSM into the job demands-job resources model of stress in order to determine whether PSM might contribute to stress in public organizations. Drawing upon original data from a questionnaire in a Swiss municipality, this study unsurprisingly shows that "red tape" is an antecedent of stress perception, whereas satisfaction with organizational support, positive feedback, and recognition significantly decrease the level of perceived stress. Astonishingly, the empirical results show that PSM is positively and significantly related to stress perception. By increasing individuals' expectations towards their jobs, PSM might thus contribute to increased pressure on public agents. Ultimately, this article investigates the "dark side" of PSM, which has been neglected by the literature thus far.
Resumo:
Combustion-derived and manufactured nanoparticles (NPs) are known to provoke oxidative stress and inflammatory responses in human lung cells; therefore, they play an important role during the development of adverse health effects. As the lungs are composed of more than 40 different cell types, it is of particular interest to perform toxicological studies with co-cultures systems, rather than with monocultures of only one cell type, to gain a better understanding of complex cellular reactions upon exposure to toxic substances. Monocultures of A549 human epithelial lung cells, human monocyte-derived macrophages and monocyte-derived dendritic cells (MDDCs) as well as triple cell co-cultures consisting of all three cell types were exposed to combustion-derived NPs (diesel exhaust particles) and to manufactured NPs (titanium dioxide and single-walled carbon nanotubes). The penetration of particles into cells was analysed by transmission electron microscopy. The amount of intracellular reactive oxygen species (ROS), the total antioxidant capacity (TAC) and the production of tumour necrosis factor (TNF)-a and interleukin (IL)-8 were quantified. The results of the monocultures were summed with an adjustment for the number of each single cell type in the triple cell co-culture. All three particle types were found in all cell and culture types. The production of ROS was induced by all particle types in all cell cultures except in monocultures of MDDCs. The TAC and the (pro-)inflammatory reactions were not statistically significantly increased by particle exposure in any of the cell cultures. Interestingly, in the triple cell co-cultures, the TAC and IL-8 concentrations were lower and the TNF-a concentrations were higher than the expected values calculated from the monocultures. The interplay of different lung cell types seems to substantially modulate the oxidative stress and the inflammatory responses after NP exposure. [Authors]
Resumo:
Motivation. The study of human brain development in itsearly stage is today possible thanks to in vivo fetalmagnetic resonance imaging (MRI) techniques. Aquantitative analysis of fetal cortical surfacerepresents a new approach which can be used as a markerof the cerebral maturation (as gyration) and also forstudying central nervous system pathologies [1]. However,this quantitative approach is a major challenge forseveral reasons. First, movement of the fetus inside theamniotic cavity requires very fast MRI sequences tominimize motion artifacts, resulting in a poor spatialresolution and/or lower SNR. Second, due to the ongoingmyelination and cortical maturation, the appearance ofthe developing brain differs very much from thehomogenous tissue types found in adults. Third, due tolow resolution, fetal MR images considerably suffer ofpartial volume (PV) effect, sometimes in large areas.Today extensive efforts are made to deal with thereconstruction of high resolution 3D fetal volumes[2,3,4] to cope with intra-volume motion and low SNR.However, few studies exist related to the automatedsegmentation of MR fetal imaging. [5] and [6] work on thesegmentation of specific areas of the fetal brain such asposterior fossa, brainstem or germinal matrix. Firstattempt for automated brain tissue segmentation has beenpresented in [7] and in our previous work [8]. Bothmethods apply the Expectation-Maximization Markov RandomField (EM-MRF) framework but contrary to [7] we do notneed from any anatomical atlas prior. Data set &Methods. Prenatal MR imaging was performed with a 1-Tsystem (GE Medical Systems, Milwaukee) using single shotfast spin echo (ssFSE) sequences (TR 7000 ms, TE 180 ms,FOV 40 x 40 cm, slice thickness 5.4mm, in plane spatialresolution 1.09mm). Each fetus has 6 axial volumes(around 15 slices per volume), each of them acquired inabout 1 min. Each volume is shifted by 1 mm with respectto the previous one. Gestational age (GA) ranges from 29to 32 weeks. Mother is under sedation. Each volume ismanually segmented to extract fetal brain fromsurrounding maternal tissues. Then, in-homogeneityintensity correction is performed using [9] and linearintensity normalization is performed to have intensityvalues that range from 0 to 255. Note that due tointra-tissue variability of developing brain someintensity variability still remains. For each fetus, ahigh spatial resolution image of isotropic voxel size of1.09 mm is created applying [2] and using B-splines forthe scattered data interpolation [10] (see Fig. 1). Then,basal ganglia (BS) segmentation is performed on thissuper reconstructed volume. Active contour framework witha Level Set (LS) implementation is used. Our LS follows aslightly different formulation from well-known Chan-Vese[11] formulation. In our case, the LS evolves forcing themean of the inside of the curve to be the mean intensityof basal ganglia. Moreover, we add local spatial priorthrough a probabilistic map created by fitting anellipsoid onto the basal ganglia region. Some userinteraction is needed to set the mean intensity of BG(green dots in Fig. 2) and the initial fitting points forthe probabilistic prior map (blue points in Fig. 2). Oncebasal ganglia are removed from the image, brain tissuesegmentation is performed as described in [8]. Results.The case study presented here has 29 weeks of GA. Thehigh resolution reconstructed volume is presented in Fig.1. The steps of BG segmentation are shown in Fig. 2.Overlap in comparison with manual segmentation isquantified by the Dice similarity index (DSI) equal to0.829 (values above 0.7 are considered a very goodagreement). Such BG segmentation has been applied on 3other subjects ranging for 29 to 32 GA and the DSI hasbeen of 0.856, 0.794 and 0.785. Our segmentation of theinner (red and blue contours) and outer cortical surface(green contour) is presented in Fig. 3. Finally, torefine the results we include our WM segmentation in theFreesurfer software [12] and some manual corrections toobtain Fig.4. Discussion. Precise cortical surfaceextraction of fetal brain is needed for quantitativestudies of early human brain development. Our workcombines the well known statistical classificationframework with the active contour segmentation forcentral gray mater extraction. A main advantage of thepresented procedure for fetal brain surface extraction isthat we do not include any spatial prior coming fromanatomical atlases. The results presented here arepreliminary but promising. Our efforts are now in testingsuch approach on a wider range of gestational ages thatwe will include in the final version of this work andstudying as well its generalization to different scannersand different type of MRI sequences. References. [1]Guibaud, Prenatal Diagnosis 29(4) (2009). [2] Rousseau,Acad. Rad. 13(9), 2006, [3] Jiang, IEEE TMI 2007. [4]Warfield IADB, MICCAI 2009. [5] Claude, IEEE Trans. Bio.Eng. 51(4) (2004). [6] Habas, MICCAI (Pt. 1) 2008. [7]Bertelsen, ISMRM 2009 [8] Bach Cuadra, IADB, MICCAI 2009.[9] Styner, IEEE TMI 19(39 (2000). [10] Lee, IEEE Trans.Visual. And Comp. Graph. 3(3), 1997, [11] Chan, IEEETrans. Img. Proc, 10(2), 2001 [12] Freesurfer,http://surfer.nmr.mgh.harvard.edu.
Resumo:
OBJECTIVES: The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND: For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning the 3D volume along the major axis of the coronary vessels may help to overcome such limitations. METHODS: Fifteen healthy adult volunteers and seven patients with X-ray angiographically confirmed coronary artery disease underwent free-breathing navigator-gated and corrected 3D coronary MRA. For an accurate volume targeting of the high resolution scans, a three-point planscan software tool was applied. RESULTS: The average length of contiguously visualized left main and left anterior descending coronary artery was 81.8 +/- 13.9 mm in the healthy volunteers and 76.2 +/- 16.5 mm in the patients (p = NS). For the right coronary artery, a total length of 111.7 +/- 27.7 mm was found in the healthy volunteers and 79.3 +/- 4.6 mm in the patients (p = NS). Comparing coronary MRA and X-ray angiography, a good agreement of anatomy and pathology was found in the patients. CONCLUSIONS: Double-oblique submillimeter free-breathing coronary MRA allows depiction of extensive parts of the native coronary arteries. The results obtained in patients suggest that the method has the potential to be applied in broader prospective multicenter studies where coronary MRA is compared with X-ray angiography.
Resumo:
A technique for fast imaging of regional myocardial function using a spiral acquisition in combination with strain-encoded (SENC) magnetic resonance imaging (MRI) is presented in this paper. This technique, which is termed fast-SENC, enables scan durations as short as a single heartbeat. A reduced field of view (FOV) without foldover artifacts was achieved by localized SENC, which selectively excited the region around the heart. The two images required for SENC imaging (low- and high-tuning) were acquired in an interleaved fashion throughout the cardiac cycle to further shorten the scan time. Regional circumferential contraction and longitudinal shortening of both the left ventricle (LV) and right ventricle (RV) were examined in long- and short-axis views, respectively. The in vivo results obtained from five human subjects and five infarcted dogs are presented. The results of the fast-SENC technique in a single heartbeat acquisition were comparable to those obtained by conventional SENC in a long acquisition time. Therefore, fast-SENC may prove useful for imaging during stress or arrhythmia.
Resumo:
OBJECTIVES: This study was designed to identify macrophage-rich atherosclerotic plaque noninvasively by imaging the tissue uptake of long-circulating superparamagnetic nanoparticles with a positive contrast off-resonance imaging sequence (inversion recovery with ON-resonant water suppression [IRON]). BACKGROUND: The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. METHODS: Experiments were conducted on a clinical 3-T magnetic resonance imaging (MRI) scanner in 7 heritable hyperlipidemic and 4 control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (2 doses of 250 mumol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3, and 6 days. RESULTS: After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on magnetic resonance images had a high correlation with the number of macrophages determined by histology (p < 0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (area under the curve: 0.92, SE: 0.04, 95% confidence interval: 0.84 to 0.96, p < 0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in control rabbits without atherosclerosis. CONCLUSIONS: Using IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.
Resumo:
The provenance, half-life and biological activity of malondialdehyde (MDA) were investigated in Arabidopsis thaliana. We provide genetic confirmation of the hypothesis that MDA originates from fatty acids containing more than two methylene-linked double bonds, showing that tri-unsaturated fatty acids are the in vivo source of up to 75% of MDA. The abundance of the combined pool of free and reversibly bound MDA did not change dramatically in stress, although a significant increase in the free MDA pool under oxidative conditions was observed. The half-life of infiltrated MDA indicated rapid metabolic turnover/sequestration. Exposure of plants to low levels of MDA using a recently developed protocol powerfully upregulated many genes on a cDNA microarray with a bias towards those implicated in abiotic/environmental stress (e.g. ROF1 and XERO2). Remarkably, and in contrast to the activities of other reactive electrophile species (i.e. small vinyl ketones), none of the pathogenesis-related (PR) genes tested responded to MDA. The use of structural mimics of MDA isomers suggested that the propensity of the molecule to act as a cross-linking/modifying reagent might contribute to the activation of gene expression. Changes in the concentration/localisation of unbound MDA in vivo could strongly affect stress-related transcription.