991 resultados para housing system
Resumo:
The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 µm-pore membranes; for mycobacteria, 0.45 µm pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.
Resumo:
In the last few years the number of systems and devices that use voice based interaction has grown significantly. For a continued use of these systems the interface must be reliable and pleasant in order to provide an optimal user experience. However there are currently very few studies that try to evaluate how good is a voice when the application is a speech based interface. In this paper we present a new automatic voice pleasantness classification system based on prosodic and acoustic patterns of voice preference. Our study is based on a multi-language database composed by female voices. In the objective performance evaluation the system achieved a 7.3% error rate.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Informática
Resumo:
OBJECTIVES: Mortality after ICU discharge accounts for approx. 20-30% of deaths. We examined whether post-ICU discharge mortality is associated with the presence and severity of organ dysfunction/failure just before ICU discharge. PATIENTS AND METHODS: The study used the database of the EURICUS-II study, with a total of 4,621 patients, including 2,958 discharged alive to the general wards (post-ICU mortality 8.6%). Over a 4-month period we collected clinical and demographic characteristics, including the Simplified Acute Physiology Score (SAPS II), Nine Equivalents of Nursing Manpower Use Score, and Sequential Organ Failure Assessment (SOFA) score. RESULTS: Those who died in the hospital after ICU discharge had a higher SAPS II score, were more frequently nonoperative, admitted from the ward, and had stayed longer in the ICU. Their degree of organ dysfunction/failure was higher (admission, maximum, and delta SOFA scores). They required more nursing workload resources while in the ICU. Both the amount of organ dysfunction/failure (especially cardiovascular, neurological, renal, and respiratory) and the amount of nursing workload that they required on the day before discharge were higher. The presence of residual CNS and renal dysfunction/failure were especially prognostic factors at ICU discharge. Multivariate analysis showed only predischarge organ dysfunction/failure to be important; thus the increased use of nursing workload resources before discharge probably reflects only the underlying organ dysfunction/failure. CONCLUSIONS: It is better to delay the discharge of a patient with organ dysfunction/failure from the ICU, unless adequate monitoring and therapeutic resources are available in the ward.
Resumo:
Involvement of the digestive system in patients with acquired immunodeficiency syndrome (AIDS) is frequent and many changes in these patients are diagnosed only at autopsy. There are few studies of autopsy with detailed analysis of this system and only one was conducted in Brazil. We evaluated each segment of the digestive system in 93 consecutive autopsies of patients infected with human immunodeficiency virus (HIV) and the importance of these lesions to death. Of these, 90 (96.8%) patients had AIDS. We reviewed medical records, autopsy reports and histological sections from tongue to rectum stained with hematoxylin-eosin. When necessary, we analyzed special stains and immunohistochemistry to investigate infections. There was damage to the digestive system in 73 (78.5%) cases. The most common infections were candidiasis (42%), cytomegalovirus (29%), histoplasmosis (11.8%), toxoplasmosis (9.7%) and mycobacterial infection (9.7%). Malignancies were rare, present in four (4.3%) cases (two Kaposi's sarcoma, one adenocarcinoma and one metastatic embryonal carcinoma). All segments showed lesions: tongue (48.6%), esophagus (44.8%), stomach (44.7%), colon (43.2%) and small intestine (28.9%). The lesions found were immediate cause of death in five (5.4%) cases. In another 36 (38.7%) cases the basic disease was systemic and also compromised the digestive system.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores
Resumo:
Assessing the safety of existing timber structures is of paramount importance for taking reliable decisions on repair actions and their extent. The results obtained through semi-probabilistic methods are unrealistic, as the partial safety factors present in codes are calibrated considering the uncertainty present in new structures. In order to overcome these limitations, and also to include the effects of decay in the safety analysis, probabilistic methods, based on Monte-Carlo simulation are applied here to assess the safety of existing timber structures. In particular, the impact of decay on structural safety is analyzed and discussed, using a simple structural model, similar to that used for current semi-probabilistic analysis.
Resumo:
Introduction: Colonic lesions are predominant in patients with schistosomiasis. However, carbohydrate alterations in colonic schistosomiasis remain unclear. Lectin-ligands allow us to identify changes in the saccharide patterns of cells. Methods: Biopsies of descending and rectosigmoid colon of patients were submitted to WGA and Con A lectin histochemistry. Results: WGA stained stroma and gland cells of descending colon and rectosigmoid tissues in a granular strong cytoplasmatic pattern in schistosomiasis specimens differing from normal control and Con A failing to recognize all samples analyzed. Conclusions: WGA ligands are expressed differently in patients with hepatosplenic schistosomiasis and no evidence of egg-granuloma system.
Resumo:
Thesis submitted to the Instituto Superior de Estatística e Gestão de Informação da Universidade Nova de Lisboa in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in Information Management – Geographic Information Systems
Resumo:
A presente dissertação tem como objetivo principal o estudo da importância que os sistemas de energias renováveis têm na obtenção da classe de eficiência energética em edifícios de habitação. Analisou-se assim, qual dos sistemas apresentados na legislação é mais vantajoso na relação entre a classe energética e o investimento necessário a efetuar. Como caso de estudo, utilizou-se um edifício de habitação em fase de projeto situada em ambiente urbano, a uma distância muito curta da costa marítima, no distrito do Porto. A primeira etapa da dissertação passou pela caracterização do edifício, determinando as suas necessidades nominais anuais de energia para aquecimento, para arrefecimento, para preparação de águas quentes sanitárias e por fim, as necessidades nominais de energia primária. Com isto, obteve-se a classe de eficiência energética da habitação sem a utilização de qualquer tipo de sistema de aproveitamento de energia renovável. Após esta obtenção, verificou-se que o edifício em análise já possuía uma classe muito eficiente, classe A, superior à classe mínima exigida pelo regulamento, B-. A desvantagem do edifício já possuir esta classe é que a implementação de sistemas de energia não iriam alterar drasticamente a classe, e por isso, não se iria conseguir retirar uma dedução correta de qual o melhor para promover a eficiência energética. De seguida, procedeu-se ao estudo dos sistemas de energia renovável, apresentando sistemas adequados para a habitação e calculando-se as novas classes de eficiência energética, com a utilização de cada sistema. Consecutivamente, começou-se a retirar ilações dos sistemas mais eficientes, ou seja, os sistemas que tem como função aquecer a moradia ou a função de preparar águas quentes sanitárias, pois, iriam mitigar necessidades nominais de energia, enquanto os sistemas de produção de energia elétrica apenas iriam contribuir para uma melhoria energética. Outra desvantagem verificada foi que, devido ao local onde a habitação se situa, não seria possível efetuar uma análise a todos os sistemas de aproveitamento de energia renovável. iv Por fim, efetuou-se uma análise dos investimentos necessários para a implementação dos sistemas de energias renováveis face às diminuições percentuais do rácio de eficiência energética. Posto isto, obteve-se os melhores sistemas a implementar na moradia, no ponto de vista de melhorar a classe de eficiência energética, seria uma caldeira a pellets com função de aquecimento e produção de águas quentes sanitárias, enquanto que, do ponto de vista financeiro obteve-se o sistema de aquecimento e produção de águas quentes sanitárias através de um recuperador de calor a lenha, que em ambos os casos a classe de eficiência energética passou de A para A+.
Resumo:
Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.