999 resultados para finger force


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Papoti, M., L.E.B. Martins, S.A. Cunha, A.M. Zagatto, and C.A. Gobatto. Effects of taper on swimming force and swimmer performance after an experimental ten-week training program. J. Strength Cond. Res. 21(2):538-542. 2007.- The purpose of this research was to examine how an 11-day taper after an 8.5-week experimental training cycle affected lactate levels during maximal exercise, mean force, and performance in training swimmers, independent of shaving, psychological changes, and postcompetition effects. Fourteen competition swimmers with shaved legs and torsos were recruited from the São Paulo Aquatic Federation. The training cycle consisted of a basic training period (endurance and quality phases) of 8.5 weeks, with 5,800 m·d -1 mean training volume and 6 d·wk -1 frequency; and a taper period (TP) of 1.5 weeks' duration that incorporated a 48% reduction in weekly volume without altering intensity. Attained swimming force (SF) and maximal performance over 200m maximal swim (Pmax) before and after taper were measured. After taper, SF and Pmax improved 3.6 and 1.6%, respectively (p < 0.05). There were positive correlations (p < 0.05) between SF and Pmax before (r = 0.86) and after (r = 0.83) the taper phase. Peak lactate concentrations after SF were unaltered before (6.79 ± 1.2 mM) and after (7.15 ± 1.8 mM) TP. Results showed that TP improved mean swimming velocity, but not in the same proportion as force after taper, suggesting that there are other factors influencing performance in faster swimming. © 2007 National Strength & Conditioning Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some dynamical properties of the one dimensional Fermi accelerator model, under the presence of frictional force are studied. The frictional force is assumed as being proportional to the square particle's velocity. The problem is described by use of a two dimensional non linear mapping, therefore obtained via the solution of differential equations. We confirm that the model experiences contraction of the phase space area and in special, we characterized the behavior of the particle approaching an attracting fixed point. © 2007 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Elastomeric materials are considered important sources of orthodontic forces. Objective: To assess force degradation over time of four commercially available orthodontic elastomeric chains (Morelli, Ormco, TP and Unitek). Methods: The synthetic elastics were submerged in 37 oC synthetic saliva and stretched by a force of 150 g (15 mm - Morelli and TP; 16mm - Unitek and Ormco). With a dynamometer, the delivered force was evaluated at different intervals: 30 minutes, 7 days, 14 days and 21 days. The results were subjected to ANOVA and Tukey's test. Results: There was a force decay between 19% to 26.67% after 30 minutes, and 36.67% to 57% after 21 days of activation. Conclusions: TP elastomeric chains exhibited the smallest percentage of force decay, with greater stability at all time intervals tested. Meanwhile, the Unitek chains displayed the highest percentage of force degradation, and no statically significant difference was found in force decay between Ormco and Morelli elastomeric chains during the study period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics of the AFM-atomic force microscope follows a model based in a Timoshenko cantilever beam with a tip attached at the free end and acting with the surface of a sample. General boundary conditions arise when the tip is either in contact or non-contact with the surface. The governing equations are given in matrix conservative form subject to localized loads. The eigenanalysis is done with a fundamental matrix response of a damped second-order matrix differential equation. Forced responses are found by using a Galerkin approximation of the matrix impulse response. Simulations results with harmonic and pulse forcing show the filtering character and the effects of the tip-sample interaction at the end of the beam. © 2012 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of fatigue induced by an exhaustive laboratory-based soccer-specific exercise on different hamstrings/quadriceps (H:Q) ratios of soccer players. Twenty-two male professional soccer players (23·1 ± 3·4 year) performed maximal eccentric (ecc) and concentric (con) contractions for knee extensors (KE) and flexors (KF) at 60° s-1 and 180° s-1 to assess conventional (Hcon:Qcon) and functional (Hecc:Qcon) ratios. Additionally, they performed maximal voluntary isometric contraction for KE and KF, from which the maximal muscle strength, rate of force development (RFD) and RFD H:Q strength ratio (RFDH:Q) were extracted. Thereafter, subjects were performed an exhaustive laboratory-based soccer-specific exercise and a posttest similar to the pretest. There was significant reduction in Hcon:Qcon (0·60 ± 0·06 versus 0·58 ± 0·06, P<0·05) and in Hecc:Qcon (1·29 ± 0·2 versus 1·16 ± 0·2, P<0·01) after the soccer-specific exercise. However, no significant difference between Pre and Post exercise conditions was found for RFDH:Q at 0-50 (0·53 ± 0·23 versus 0·57 ± 0·24, P>0·05) and 0-100 ms (0·53 ± 0·17 versus 0·55 ± 0·17, P>0·05). In conclusion, H:Q strength ratios based on peak force values are more affected by fatigue than RFDH:Q obtained during early contraction phase. Thus, fatigue induced by soccer-specific intermittent protocol seems not reduce the potential for knee joint stabilization during the initial phase of voluntary muscle contraction. copy; 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to determine whether: i) tethered-swimming can be used to identify the asymmetry during front crawl swimming style; ii) swimmers that perform unilateral breathing present greater asymmetry in comparison to others that use bilateral breathing; iii) swimmers of best performance present smaller asymmetry than their counterparts; iv) repeated front crawl swimming movements influence body asymmetry. 18 swimmers were assessed for propulsive force parameters (peak force, mean force, impulse and rate of force development) during a maximal front crawl tethered-swimming test lasting 2 min. A factorial analysis showed that propulsive forces decreased at the beginning, intermediate and end of the test (p<0.05), but the asymmetries were not changed at different instants of the test. When breathing preference (uni- or bilateral) was analyzed, asymmetry remained unchanged in all force parameters (p>0.05). When performance was considered (below or above mean group time), a larger asymmetry was found in the sub-group of lower performance in comparison to those of best performance (p<0.05). Therefore, the asymmetries of the propulsive forces can be detected using tethered-swimming. The propulsive forces decreased during the test but asymmetries did not change under testing conditions. Although breathing preference did not influence asymmetry, swimmers with best performance were less asymmetric than their counterparts. © Georg Thieme Verlag KG Stuttgart New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multiferroic behavior with ion modification using rare-earth cations on crystal structures, along with the insulating properties of BiFeO3 (BFO) thin films was investigated using piezoresponse force microscopy. Rare-earth-substituted BFO films with chemical compositions of (Bi 1.00-xRExFe1.00O3 (x=0; 0.15), RE=La and Nd were fabricated on Pt (111)/Ti/SiO2/Si substrates using a chemical solution deposition technique. A crystalline phase of tetragonal BFO was obtained by heat treatment in ambient atmosphere at 500 °C for 2 h. Ion modification using La3+ and Nd3+ cations lowered the leakage current density of the BFO films at room temperature from approximately 10-6 down to 10-8 A/cm2. The observed improved magnetism of the Nd3+ substituted BFO thin films can be related to the plate-like morphology in a nanometer scale. We observed that various types of domain behavior such as 71° and 180° domain switching, and pinned domain formation occurred. The maximum magnetoelectric coefficient in the longitudinal direction was close to 12 V/cm Oe. © 2012 Elsevier Ltd and Techna Group S.r.l.