943 resultados para epoxy resin-based root canal sealer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The purpose of this in vivo study was to compare the effectiveness of a new light cured resin based dicalcium/tricalcium silicate pulp capping material (TheraCal LC, Bisco), pure Portland cement, resin based calcium hydroxide or glass ionomer in the healing of bacterially contaminated primate pulps. Study design: The experiment required four primates each having 12 teeth prepared with buccal penetrations into the pulpal tissues with an exposure of approximately 1.0 mm. The exposed pulps of the primate teeth were covered with cotton pellets soaked in a bacterial mixture consisting of microorganisms normally found in human pulpal abscesses. After removal of the pellet, hemostasis was obtained and the pulp capping agents applied. The light cured resin based pulp capping material (TheraCal LC) was applied to the pulpal tissue of twelve teeth with a needle tip syringe and light cured for 15 seconds. Pure Portland cement mixed with a 2% Chlorhexidine solution was placed on the exposed pulpal tissues of another twelve teeth. Twelve additional teeth had a base of GIC applied (Triage, Fuji VII GC America) and another twelve had a pulp cap with VLC DYCAL (Dentsply), a light cured calcium hydroxide resin based material. The pulp capping bases were then covered with a RMGI (Fuji II LC GC America). The tissue samples were collected at 4 weeks. The samples were deminerilized, sectioned, stained and histologically graded. Results: There were no statistically significant differences between the groups in regard to pulpal inflammation (H= 0.679, P=1.00). However, both the Portland cement and light cured TheraCal LC groups had significantly more frequent hard tissue bridge formation at 28 days than the GIC and VLC Dycal groups (H= 11.989, P=0.009). The measured thickness of the hard tissue bridges with the pure Portland and light cured TheraCal LC groups were statistically greater than that of the other two groups (H= 15.849, P=0.002). In addition, the occurrence of pulpal necrosis was greater with the GIC group than the others. Four premolars, one each treated according to the protocols were analyzed with a microCT machine. The premolar treated with the light cured TheraCal LC demonstrated a complete hard tissue bridge. The premolar treated with the GIC did not show a complete hard tissue bridge while the premolar treated with VLC Dycal had an incomplete bridge. The pure Portland with Chlorhexidine mixture created extensive hard tissue bridging.Conclusion: TheraCal LC applied to primate pulps created dentin bridges and mild inflammation acceptable for pulp capping.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Products derived from wood or engineered products are becoming interesting alternatives to the replacement of solid wood in various applications, from structural components to the furniture industry and packaging. Among these products, there are panels built by strands, particles and fibers, each one having their particular characteristics and potential of use. Since the different types of panels are produced, waste generation is part of the process, and that more technological it is, it still generates losses of raw materials. Based on the need for rational use of raw materials and using almost full of industrially processed wood, It arises the proposal of this work, which seeks to use waste from the lamination, like pieces of strands, broken strands, strands rough, cracked strands to produce panels with structural characteristics of the OSL panel (Oriented Strand Lumber), LSL (Laminated Strand Lumber) and OSB (Oriented Strand Lumber). Besides the use of waste, this paper seeks an alternative to the use of the adhesive, because the industry uses formaldehyde-based adhesives, which over the press, they emit large amounts of formaldehyde, which is very aggressive to humans and environment. The panels made with polyurethane resin based on castor oil and hot-pressed were characterized by physical and mechanical tests according to specifications of European Standard (EN). High values of tensile strength, elastic modulus and density were found in the results of tests. Adding to stable values of swelling and moisture content, the panel studied adds attractive features to the panel market, especially in the civil construction

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years the aeronautic industries has increased investment in areas of technological research aiming at materials that offer better performance, safety, weight reduction and fuel consumption. For this reason the most studied materials are polymeric materials, due to their higher mechanical strength and higher stiffness. This work evaluated characteristics of two composite laminates produced from the same process, but they differed only in regions where the resin was injected and the vacuum position. The composite laminates were SC-79 resin reinforced with glass fiber fabric (plain weave) processed via VARTM. For this reason the material was subjected to mechanical tests such as: tensile, and fatigue following standards ASTM D 3039 and ASTM D 3479, respectively. The latter was observed the S-N curve. It was performed the ultrassonic C-scan analysis to check impregnation of the fiber. Considering that the process was the same for the two laminates, with small variations in the injection and in vacum ports, it was expected to find similar characteristics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro antimicrobial activity of chlorhexidine gel and liquid 2%, and 2% sodium hypochlorite on Candida albicans, Enterococcus faecalis, Escherichia coli in root canals. For this, we used 40 human single-rooted teeth were divided into 4 groups (n = 10) according to assist the chemical used: 1) 2% chlorhexidine liquid, 2) 2% chlorhexidine gel, 3) sodium hypochlorite 2%, and 4) physiological saline (control). Content were collected immediately after root canal instrumentation and after 7 days of biomechanical. For the samples was conducted to evaluate the antimicrobial activity and the results were subjected to statistical analysis of Kruskal-Wallis and Dunn's test with a significance of 5%. It was found that chlorhexidine gel and liquid as well as sodium hypochlorite were effective against the microorganisms tested

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In civil engineering, a structure is the whole sustainment of a construction and, thus, it is important that it remains intact throughout its lifetime. An engineering construction must last for decades without losing its functionality. However its purpose may be altered and several times the original structure does not meet the new needs of use. Still, in new buildings, the functionality is altered due to possible flaws in execution and the structure, invariably does not reach the desired solicitation needs. In cases like this, the commonly adopted solutions are, basically, the demolishment followed by the reconstruction of the desired mold or the structural reinforcement. This second option, for long years, has not been put to practice due to certain factors such as the high costs for its implantation, use of inadequate reinforcement execution techniques, and the culture of people involved in the area regarding its use and, in this case, the option would always be the reconstruction. Thoughtout the years, some techniques were developed to allow the execution of structural reinforcements with low costs and in efficient ways. An interesting, fast, efficient and economical technique is the structural reinforcement through metal sheets put together with epoxy resin that can be applied in beams, slabs and pillars. In the present work the different behavior of beams reinforced with this technique. Steel is a very recommended material for these reinforcements due to its characteristics related to traction, compression and the effectiveness of the technique related to its cost. For the attachment the epoxy resin is recommended, since it allows the joining of two materials, in this case, steel and concrete. The efficiency of this union is so considerably high that it rarely produces any flaws in adherence and, normally, when it happens it is due to problems in the execution process, not in the union of materials

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Technology is growing interest in the use of composites, due to the requirement of lighter materials and more resistant, factors essential to meet the project specifications and reduce the operational cost. In the production of high performance structural composites, considering the aerospace criteria, the domestic industry has shown interest in the process of resin transfer molding (RTM) for reproducibility and low cost. This process is suitable for producing components of polymeric composites with relatively simple geometries, consistent thicknesses, high quality finish with no size limitations. The objective of this work was machined carbon steel to make a matched-die tooling for RTM and produce two composite plates of epoxy resin and carbon fiber fabric with and without induced discontinuities, which were compared towards their impregnation with ultrasound, their properties via tensile tests and thermal analysis. In ultrasonic inspection, it was found good impregnation of the preform of both composites. In the thermal analysis it was possible to check the degradation temperature of the composites, the glass transition temperature and it was found that the composites showed no effective cure cycles, but presented good performance in the tensile test when compared with aluminum alloy 7050 T7451 . The results showed that the injection strategy was appropriate since the laminate exhibited a good quality for the proposed application

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the increasing demand for electricity, the retraining of transmission lines is necessary despite environmental restrictions and crossings in densely populated areas to build new transmission and distribution lines. Solution is reuse the existent cables, replacing the old conductor cables for new cables with higher capacity power transmission, and control of sag installed. The increasing demand for electrical power has increased the electric current on the wires and therefore, it must bear out temperatures of 150°C or more, without the risk of the increasing sag beyond the established limits. In the case of long crossings or densely populated areas, sag is due to high weight of the cable on clearance. The cable type determines the weight, sag, height and the towers dimensions, which are the items that most influence the investment of the transmission line. Hence, to reduce both cost of investment and maintenance of the line, the use of a lighter cable can reduce both number and the height of the towers, with financial return on short and long term. Therefore, in order to increase the amount of transmitted energy and reduce the number of built towers and sag, is recommended in the current work substitute the current core material (steel or aluminium) for alternatives alloys or new materials, in this case a composite, which has low density, elevated stiffness (elasticity module), thus apply the pultruded carbon fiber with epoxy resin as matrix systems and perform the study of the kinetics of degradation by thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), according to their respective standards

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years a great worldwide interest has arisen for the development of new technologies that enable the use of products with less environmental impact. The replacement of synthetic fiber plants is a possibility very important because this fiber is renewable, biodegradable and few cost and cause less environmental impact. Given the above, this work proposes to develop polymeric composites of epoxy resin and study the behavior of these materials. Both, the epoxy resin used as matrix in the manufacture of sapegrass fiber composite, as tree composites formed by: epoxy/unidirectional sapegrass long fiber, 75% epoxy/25% short fiber, by volume, and 80% epoxy/20% short fiber, by volume, were characterized by bending, and the composites produced with short fibers random were inspected by Optical Microscopy and Acoustics Inspection (C-Scan). For the analysis of the sapegrass fiber morphology, composites 75% epoxy/25% short fiber (sheet chopped) and 80% epoxy/20% short fiber images were obtained by optical microscope and the adhesion between polymer/fiber was visualized. As results, the flexural strength of composites epoxy/unidirectional long fibers, 75% epoxy/25% short fiber and 80% epoxy/20% short fiber were 70.36 MPa, 21.26 MPa, 25.07 MPa, respectively. Being that composite showed that the best results was made up of long fibers, because it had a value of higher flexural strength than other composites analyzed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the antimicrobial activity of chlorhexidine gel 2% as auxiliary chemical substance on the biomechanical preparation (BMP) and medication intracanal (ICM) on C. albicans, E. faecalis, E. coli and their endotoxin in root canals. We used 48 single-rooted human teeth divided into four groups according to dressing ICM: 1) Ca(OH)2 + pyrogen-free saline solution; 2) 2% chlorhexidine gel (CLX); 3) Ca(OH)2 + CLX, and; 4) pyrogen-free saline solution (control group). Were collected the contents of root canals to confirm the presence of microorganisms (confirmation), immediately after instrumentation (1st collection), after 7 days of the BMP (2nd collection), after 14 days of the action of ICM (3rd Collection) and 7 days after removal of the ICM (4 th collection). Were performed: the evaluation of antimicrobial activity and the content analysis of endotoxins for all sampling tests. The results were statistically analyzed using Kruskall-Wallis and Dunn tests with a significance of 5%. It was found that the CLX as auxiliary chemical substance has significantly reduced microorganisms confirmation collection when compared. In relation to the neutralization of endotoxin, it was found that the 1st and 2nd collections presented a decrease of 92.03% and 98.10% in mean percentage respectively, when compared to the confirmation collection. In the 3rd and 4th samplings, the Ca (OH)2 + CLX group showed the best results. It was concluded that the BMP and the ICM were able to eliminate the tested microrganisms, however, they were not able to completely eliminate endotoxins root canal

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hybrid composites combining metal plates and laminates with continuous fiber reinforced polymer, called fiber-metal (CHMF), have been particularly attractive for aerospace applications, due mainly to their high mechanical strength and stiffness associated with low density. These laminates (CHMF) consist of a sandwich structure consisting of layers of polymer composites and metal plates, stacked alternately. This setting allows you to combine the best mechanical performance of polymer composites reinforced with long fibers, to the high toughness of metals. Environmental effects should always be considered in the design of structural components, because these materials in applications are submitted to the effects of moisture in the atmosphere, the large cyclical variations of temperature around 82 ° C to -56 ° C, and high effort mechanical. The specimens of fibermetal composite were prepared at EMBRAER with titanium plates and laminates of carbon fiber/epoxy resin. This study aims to evaluate the effect of different environmental conditions (water immersion, hygrothermal chamber and thermal shock) of laminate hybrid titanium/carbon fiber/epoxy resin. The effects of conditioning were evaluated by interlaminar shear tests - ILSS, tensile, and vibration free

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The maxillary lateral incisor has a very peculiar and internal morphology that can be influenced by the its external anatomy such as supernumerary roots and ruts deep root, which often hinders an effective endodontic treatment. Generally, this tooth have a single root with one root canal, but teeth with two to four channels can be found. The main canal can present ramifications such as accessory canals, laterals, collaterals, recorrents and apical deltas. All this factors interfere directally on endodonthics treatment. The objective of this work is a study of the internal anatomy of the maxillary lateral incisors by digital and conventional radiographics methods, comparing the results obteined by each method Six hundred upper lateral incisor were used in this study teeth of the collection of the Department of Anatomy ICT – UNESP. All the teeth were radiographed by vestibular face, using a digital radiographic unit(Dabi Atlante). After this step, all the teeth underwent by conventional radiographic technique(Kodak 2200) so that the results obtained were compared. To classify the channel system, it was adopted the classification of Pucci and Reig. All data obtained by digital technique were compared with those obtained in the conventional technique and were subjected to statistical analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the abrasion wear resistance and superficial roughness of different glass ionomer cements used as restorative materials, focusing on a new nanoparticulate material. Material and Method: Three glass ionomer cements were evaluated: Ketac Molar, Ketac N100 and Vitremer (3M ESPE, St. Paul, MN, USA), as well as the Filtek Z350 (3M ESPE, St. Paul, MN, USA). For each material were fabricated circular specimens (n=12), respecting the handling mode specified by the manufacturer, which were polished with sandpaper disks of decreasing grit. The wear was determined by the amount of mass (M) lost after brushing (10,000 cycles) and the roughness (Ra) using a surface roughness tester. The difference between the Minitial and Mfinal (ΔM) as well as beroughness of aesthetic restorative materials: an in vitro comparison. SADJ. 2001; 56(7): 316-20. 11. Yip HK, Peng D, Smales RJ. Effects of APF gel on the physical structure of compomers and glass ionomer cements. Oper. Dent. 2001; 26(3): 231-8. 12. Ma T, Johnson GH, Gordon GE. Effects of chemical disinfectants on the surface characteristics and color of denture resins. J Prosthet Dent 1997; 77(2): 197-204. 13. International organization for standardization. Technical specification 14569-1. Dental Materials – guidance on testing of wear resistance – PART I: wear by tooth brushing. Switzerland: ISO; 1999. 14. Bollen CML, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater.1997; 13(4): 258-9. 15. Kielbassa AM, Gillmann C, Zantner H, Meyer-Lueckel H, Hellwig E, Schulte-Mönting J. Profilometric and microradiographic studies on the effects of toothpaste and acidic gel abrasivity on sound and demineralized bovine dental enamel. Caries Res. 2005; 39(5): 380-6. 16. Tanoue N, Matsumara H, Atsuta M. Wear and surface roughness of current prosthetic composites after toothbrush/dentifrice abrasion. J Prosthet Dent. 2000; 84(1): 93-7. 17. Heath JR, Wilson HJ. Abrasion of restorative materials by toothpaste. J Oral Rehabil. 1976; 3(2): 121-38. 18. Frazier KB, Rueggeberg FA, Mettenburg DJ. Comparasion of wearresistance of class V restorative materials. J Esthet Dent. 1998; 10(6): 309-14. 19. Momoi Y, Hirosakil K, Kohmol A, McCabe JF. In vitro toothebrushdentifrrice abrasion of resin-modified glass ionomers. Dent Mater. 1997; 13(2): 82-8. 20. Turssi CP, Magalhães CS, Serra MC, Rodrigues Jr.AL. Surface roughness assessment of resin-based materials during brushing preceded by pHcycling simulations. Oper Dent. 2001; 26(6): 576-84. 21. Wang L, Cefaly DF, Dos Santos JL, Dos Santos JR, Lauris JR, Mondelli RF, et al. In vitro interactions between lactic acid solution and art glassionomer cements. J Appl Oral Sci. 2009; 17(4): 274-9. 22. Carvalho FG, Fucio SB, Paula AB, Correr GM, Sinhoreti MA, PuppinRontani RM. Child toothbrush abrasion effect on ionomeric materials. J Dent Child (Chic). 2008; 75(2): 112-6. 23. Coutinho E, Cardoso MV, De Munck J, Neves AA, Van Landuyt KL, Poitevin A, et al. Bonding effectiveness and interfacial characterization of a nano-filled resin-modified glass-ionomer. Dent Mater. 2009; 25(11): 1347-57. tween Rainitial and Rafinal (ΔRa) were also used for statistical analysis (α=0.05). Results: Except for the composite, significant loss of mass was observed for all glass ionomer cements and the ΔM was comparable for all of them. Significant increase in roughness was observed only for Vitremer and Ketac N100. At the end of the brushing cycle, just Vitremer presented surface roughness greater than the composite resin. Conclusion: All glass ionomer cements showed significant weight loss after 10,000 cycles of brushing. However, only Vitremer showed an increase of roughness greater than the Z350 resin, while the nanoparticulate cement Ketac N100 showed a smooth surface comparable to the composite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to evaluate the measurement accuracy of endodontic files obtained by digital and conventional radiographies in primary teeth. Kerr and Hedströen files (# 20), with the reference as the apparent length of tooth, were inserted in the root canal of 18 extracted primary teeth, which were x-rayed by digital and conventional techniques. Measurements from a reference point to the apical end were carried out by an experienced operator twice in a week. An electronic ruler was used for the digital method and a caliper was used for the conventional method. The data were subjected to Pearson correlation test and Student´s t test (p = 0.05). The correlation between the first and the second measurements was r = 0.99, regardless the type of file and method. Comparing the measurements within the methods, the agreement was r = 0.96 for Kerr and r = 0.95 for Hedströen files. The values of length files in the digital radiographies were statistically lower than that obtained in the conventional radiographies (p = 0.02). However, the values obtained by the two methods were statistically similar to real length of teeth for Kerr files (p = 0.29) and for Hedströen files (p = 0.18). The digital radiography was a more trustful method to obtain the lengths of endodontic files.