978 resultados para diagnostic fluorescent PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diazacoronand 2 undergoes drastic conformational switching upon binding sodium ions as demonstrated by solution- and solid-state studies, which permit the design of efficient fluorescent PET (photoinduced electron transfer) switches 3a,b.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MOLECULES that perform logic operations are prerequisites for molecular information processing and computation. We and others have previously reported receptor molecules that can be considered to perform simple logic operations by coupling ionic bonding or more complex molecular-recognition processes with photonic (fluorescence) signals: in these systems, chemical binding (the 'input') results in a change in fluorescence intensity (the 'output') from the receptor. Here we describe a receptor (molecule (1) in Fig. 1) that operates as a logic device with two input channels: the fluorescence signal depends on whether the molecule binds hydrogen ions, sodium ions or both. The input/output characteristics of this molecular device correspond to those of an AND gate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluorophore-spacer1-receptor1-spacer2-receptor2 system (where receptor2 alone is photoredox-inactive) shows ionically tunable proton-induced fluorescence off-on switching, which is reminiscent of thermionic triode behavior. This also represents a new extension to modular switch systems based on photoinduced electron transfer (PET) towards the emulation of analogue electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Recent observational studies indicate that post-diagnostic use of aspirin in breast cancer patients may protect against cancer progression perhaps by inhibiting cyclooxygenase-2 dependent mechanisms. Evidence also supports a crucial role for interactions between tumour cells and circulating platelets in cancer growth and dissemination, therefore, use of low-dose aspirin may reduce the risk of death from cancer in breast cancer patients.

METHODS: A cohort of newly diagnosed breast cancer patients (1998 to 2006) were identified in the UK Clinical Practice Research Datalink (and confirmed by cancer registry linkage). Cancer-specific deaths were identified up to 2011 from Office for National Statistics mortality data. A nested case-control analysis was conducted using conditional logistic regression to compare post-diagnostic aspirin exposure using General Practice prescription data in 1,435 cases (breast cancer deaths) with 5,697 controls (matched by age and year of diagnosis).

RESULTS: After breast cancer diagnosis, 18.3% of cancer-specific deaths and 18.5% of matched controls received at least one prescription for low-dose aspirin, corresponding to an odds ratio (OR) of 0.98 (95% CI 0.83, 1.15). Adjustment for potential confounders (including stage and grade) had little impact on this estimate. No dose response relationship was observed when the number of tablets was investigated and no associations were seen when analyses were stratified by receipt of prescriptions for aspirin in the pre-diagnostic period, by stage at diagnosis or by receipt of prescriptions for hormone therapy.

CONCLUSIONS: Overall, in this large population-based cohort of breast cancer patients, there was little evidence of an association between receipt of post-diagnostic prescriptions for low-dose aspirin and breast cancer-specific death. However, information was not available on medication compliance or over-the-counter use of aspirin, which may have contributed to the null findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Excessive use of empirical antibiotics is common in critically ill patients. Rapid biomarker-based exclusion of infection may improve antibiotic stewardship in ventilator-acquired pneumonia (VAP). However, successful validation of the usefulness of potential markers in this setting is exceptionally rare.

Objectives: We sought to validate the capacity for specific host inflammatory mediators to exclude pneumonia in patients with suspected VAP. 

Methods: A prospective, multicentre, validation study of patients with suspected VAP was conducted in 12 intensive care units. VAP was confirmed following bronchoscopy by culture of a potential pathogen in bronchoalveolar lavage fluid (BALF) at >104 colony forming units per millilitre (cfu/mL). Interleukin-1 beta (IL-1β), IL-8, matrix metalloproteinase-8 (MMP-8), MMP-9 and human neutrophil elastase (HNE) were quantified in BALF. Diagnostic utility was determined for biomarkers individually and in combination. 

Results: Paired BALF culture and biomarker results were available for 150 patients. 53 patients (35%) had VAP and 97 (65%) patients formed the non-VAP group. All biomarkers were significantly higher in the VAP group (p<0.001). The area under the receiver operator characteristic curve for IL-1β was 0.81; IL-8, 0.74; MMP-8, 0.76; MMP-9, 0.79 and HNE, 0.78. A combination of IL-1β and IL-8, at the optimal cut-point, excluded VAP with a sensitivity of 100%, a specificity of 44.3% and a post-test probability of 0% (95% CI 0% to 9.2%). 

Conclusions: Low BALF IL-1β in combination with IL-8 confidently excludes VAP and could form a rapid biomarker-based rule-out test, with the potential to improve antibiotic stewardship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photophysics of the green fluorescent protein is governed by the electronic structure of the chromophore at the heart of its β-barrel protein structure. We present the first two-color, resonance-enhanced, multiphoton ionization spectrum of the isolated neutral chromophore in vacuo with supporting electronic structure calculations. We find the absorption maximum to be 3.65 ± 0.05 eV (340 ± 5 nm), which is blue-shifted by 0.5 eV (55 nm) from the absorption maximum of the protein in its neutral form. Our results show that interactions between the chromophore and the protein have a significant influence on the electronic structure of the neutral chromophore during photoabsorption and provide a benchmark for the rational design of novel chromophores as fluorescent markers or photomanipulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a quick PCR-based method to distinguish European cryptic Myotis spp., Myotis mystacinus, Myotis brandtii and Myotis alcathoe is described. Primers were designed around species-specific single nucleotide polymorphisms (SNP's) in the ND1 mitochondrial gene, and a pair of control primers was designed in the 12S mitochondrial gene. A multiplex of seven primer combinations produces clear species-specific bands using gel electrophoresis. Robustness of the method was tested on 33 M. mystacinus, 16 M. brandtii and 15 M. alcathoe samples from across the European range of these species. The method worked well on faecal samples collected from maternity roosts of M. mystacinus. The test is intended to aid collection of data on these species through a rapid and easy identification method with the ability to use DNA obtained from a range of sources including faecal matter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: There is an urgent need to develop diagnostic tests to improve the detection of pathogens causing life-threatening infection (sepsis). SeptiFast is a CE-marked multi-pathogen real-time PCR system capable of detecting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here a systematic review and meta-analysis of diagnostic accuracy studies of SeptiFast in the setting of suspected sepsis.

Methods: A comprehensive search strategy was developed to identify studies that compared SeptiFast with blood culture in suspected sepsis. Methodological quality was assessed using QUADAS. Heterogeneity of studies was investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in receiver operator characteristic space. Bivariate model method was used to estimate summary sensitivity and specificity.

Results: From 41 phase III diagnostic accuracy studies, summary sensitivity and specificity for SeptiFast compared with blood culture were 0.68 (95 % CI 0.63–0.73) and 0.86 (95 % CI 0.84–0.89) respectively. Study quality was judged to be variable with important deficiencies overall in design and reporting that could impact on derived diagnostic accuracy metrics.

Conclusions: SeptiFast appears to have higher specificity than sensitivity, but deficiencies in study quality are likely to render this body of work unreliable. Based on the evidence presented here, it remains difficult to make firm recommendations about the likely clinical utility of SeptiFast in the setting of suspected sepsis.