956 resultados para diagnostic and prognostic algorithms developmen
Resumo:
BACKGROUND Assessment of pre-test probability of pulmonary embolism (PE) and prognostic stratification are two widely recommended steps in the management of patients with suspected PE. Some items of the Geneva prediction rule may have a prognostic value. We analyzed whether the initial probability assessed by the Geneva rule was associated with the outcome of patients with PE. METHODS In a post-hoc analysis of a multicenter trial including 1,693 patients with suspected PE, the all-cause death or readmission rates during the 3-month follow-up of patients with confirmed PE were analyzed. PE probability group was prospectively assessed by the revised Geneva score (RGS). Similar analyses were made with the a posteriori-calculated simplified Geneva score (SGS). RESULTS PE was confirmed in 357 patients and 21 (5.9%) died during the 3-month follow-up. The mortality rate differed significantly with the initial RGS group, as with the SGS group. For the RGS, the mortality increased from 0% (95% Confidence Interval: [0-5.4%]) in the low-probability group to 14.3% (95% CI: [6.3-28.2%]) in the high-probability group, and for the SGS, from 0% (95% CI: [0-5.4%] to 17.9% (95% CI: [7.4-36%]). Readmission occurred in 58 out of the 352 patients with complete information on readmission (16.5%). No significant change of readmission rate was found among the RGS or SGS groups. CONCLUSIONS Returning to the initial PE probability evaluation may help clinicians predict 3-month mortality in patients with confirmed PE. (ClinicalTrials.gov: NCT00117169).
Resumo:
The respiratory tract is an attractive target organ for novel diagnostic and therapeutic applications with nano-sized carriers, but their immune effects and interactions with key resident antigen-presenting cells (APCs) such as dendritic cells (DCs) and alveolar macrophages (AMs) in different anatomical compartments remain poorly understood. Polystyrene particles ranging from 20 nm to 1,000 nm were instilled intranasally in BALB/c mice, and their interactions with APC populations in airways, lung parenchyma, and lung-draining lymph nodes (LDLNs) were examined after 2 and 24 hours by flow cytometry and confocal microscopy. In the main conducting airways and lung parenchyma, DC subpopulations preferentially captured 20-nm particles, compared with 1,000-nm particles that were transported to the LDLNs by migratory CD11blow DCs and that were observed in close proximity to CD3+ T cells. Generally, the uptake of particles increased the expression of CD40 and CD86 in all DC populations, independent of particle size, whereas 20-nm particles induced enhanced antigen presentation to CD4+ T cells in LDLNs in vivo. Despite measurable uptake by DCs, the majority of particles were taken up by AMs, irrespective of size. Confocal microscopy and FACS analysis showed few particles in the main conducting airways, but a homogeneous distribution of all particle sizes was evident in the lung parenchyma, mostly confined to AMs. Particulate size as a key parameter determining uptake and trafficking therefore determines the fate of inhaled particulates, and this may have important consequences in the development of novel carriers for pulmonary diagnostic or therapeutic applications.
Resumo:
A social Semantic Web empowers its users to have access to collective Web knowledge in a simple manner, and for that reason, controlling online privacy and reputation becomes increasingly important, and must be taken seriously. This chapter presents Fuzzy Cognitive Maps (FCM) as a vehicle for Web knowledge aggregation, representation, and reasoning. With this in mind, a conceptual framework for Web knowledge aggregation, representation, and reasoning is introduced along with a use case, in which the importance of investigative searching for online privacy and reputation is highlighted. Thereby it is demonstrated how a user can establish a positive online presence.
Resumo:
The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.
Resumo:
Bipolar mixed states combine depressive and manic features, presenting diagnostic and treatment challenges and reflecting a severe form of the illness. DSM-IV criteria for a mixed state require combined depressive and manic syndromes, but a range of mixed states has been described clinically. A unified definition of mixed states would be valuable in understanding their diagnosis, mechanism and treatment implications. We investigated the manner in which depressive and manic features combine to produce a continuum of mixed states. In 88 subjects with bipolar disorder (DSM-IV), we evaluated symptoms and clinical characteristics, and compared depression-based, mania-based, and other published definitions of mixed states. We developed an index of the extent to which symptoms were mixed (Mixed State Index, MSI) and characterized its relationship to clinical state. Predominately manic and depressive mixed states using criteria from recent literature, as well as Kraepelinian mixed states, had similar symptoms and MSI scores. Anxiety correlated significantly with depression scores in manic subjects and with mania scores in depressed subjects. Discriminant function analysis associated mixed states with symptoms of hyperactivity and negative cognitions, but not subjective depressive or elevated mood. High MSI scores were associated with severe course of illness. For depressive or manic episodes, characteristics of mixed states emerged with two symptoms of the opposite polarity. This was a cross-sectional study. Mixed states appear to be a continuum. An index of the degree to which depressive and manic symptoms combine appears useful in identifying and characterizing mixed states. We propose a depressive or manic episode with three or more symptoms of the opposite polarity as a parsimonious definition of a mixed state.
Resumo:
INTRODUCTION: Penile erection is a hemodynamic process, which results from increased flow and retention of blood in the penile organ due to the relaxation of smooth muscle cells. Adenosine, a physiological vasorelaxant, has been shown to be a modulator of penile erection. AIM: To summarize the research on the role of adenosine signaling in normal penile erection and erectile disorders. MAIN OUTCOME MEASURES: Evidence in the literature on the association between adenosine signaling and normal and abnormal penile erection, i.e., erectile dysfunction (ED) and priapism. METHODS: The article reviews the literature on the role of endogenous and exogenous adenosine in normal penile erection, as well as in erectile disorders namely, ED and priapism. RESULTS: Adenosine has been shown to relax corpus cavernosum from various species including human in both in vivo and in vitro studies. Neuromodulatory role of adenosine in corpus cavernosum has also been demonstrated. Impaired adenosine signaling through A(2B) receptor causes partial resistance of corpus cavernosum, from men with organic ED, to adenosine-mediated relaxation. Increased level of adenosine has been shown to be a causative factor for priapism. CONCLUSION: Overall, the research reviewed here suggests a general role of exogenous and endogenous adenosine signaling in normal penile erection. From this perspective, it is not surprising that impaired adenosine signaling is associated with ED, and excessive adenosine signaling is associated with priapism. Adenosine signaling represents a potentially important diagnostic and therapeutic target for the treatment of ED and priapism.
Resumo:
Objective: Section III of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) lists attenuated psychosis syndrome as a condition for further study. One important question is its prevalence and clinical significance in the general population. Method: Analyses involved 1229 participants (age 16-40 years) from the general population of Canton Bern, Switzerland, enrolled from June 2011 to July 2012. "Symptom," "onset/worsening," "frequency," and "distress/disability" criteria of attenuated psychosis syndrome were assessed using the structured interview for psychosis-risk syndromes. Furthermore, help-seeking, psychosocial functioning, and current nonpsychotic axis I disorders were surveyed. Well-trained psychologists performed assessments using the computer-assisted telephone interviewing technique. Results: The symptom criterion was met by 12.9% of participants, onset/worsening by 1.1%, frequency by 3.8%, and distress/disability by 7.0%. Symptom, frequency, and distress/disability were met by 3.2%. Excluding trait-like attenuated psychotic symptoms (APS) decreased the prevalence to 2.6%, while adding onset/worsening reduced it to 0.3%. APS were associated with functional impairments, current mental disorders, and help-seeking although they were not a reason for help-seeking. These associations were weaker for attenuated psychosis syndrome. Conclusions: At the population level, only 0.3% met current attenuated psychosis syndrome criteria. Particularly, the onset/worsening criterion, originally included to increase the likelihood of progression to psychosis, lowered its prevalence. Because progression is not required for a self-contained syndrome, a revision of the restrictive onset criterion is proposed to avoid the exclusion of 2.3% of persons who experience and are distressed by APS from mental health care. Secondary analyses suggest that a revised syndrome would also possess higher clinical significance than the current syndrome.
Resumo:
Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy. Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the DVHs from each plan iteration. We used a tumor control probability (TCP) model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Results: Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the target for both IMRT and RapidArc. The couch caused average dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically impactful loss of dose or coverage for IMRT but still causes an unacceptable loss for RapidArc. Conclusions: Both the imaging couch top and rails contribute to dose and coverage loss to a degree that, if included, would prevent the plan from meeting clinical planning criteria. Therefore, the imaging and mesh couch tops and rails should be accounted for in Arc Therapy and the imaging couch and rails only in IMRT treatment planning.
Resumo:
Purpose: First, to determine an average and maximum displacement of the shoulder relative to isocenter over the course of treatment. Second, to establish the dosimetric effect of shoulder displacements relative to correct isocenter alignment on the dose delivered to the target and the surrounding structures for head and neck cancer patients. Method and Materials: The frequency of shoulder shifts of various magnitudes relative to isocenter was assessed for 4 patients using image registration software. The location of the center of the right and left humeral head relative to isocenter (usually C2) was found daily from CT on rails scans, and was compared to the location of the humeral heads relative to isocenter on the initial simulation CT. Three Baseline head and neck IMRT and SmartArc plans were generated in Pinnacle based on simulation CTs. The CT datasets (external contour and boney structures) were then modified to represent shifts of the shoulder (relative to isocenter) between 3 mm and 15 mm in the SI, AP, and LR directions. The initial plans were recalculated on the image sets with shifted shoulders. Results: On average, shoulder variation was 2-5 mm in each direction, although displacements of over 1 cm in the inferior and posterior directions occurred. Shoulder shifts induced perturbations in the dose distribution, although generally only for large shifts. Most substantially, large, superior shifts resulted in coverage loss by the 95% isodose line for targets in the lower neck. Inferior shifts elevated the dose to the brachial plexus by 0.6-4.1 Gy. SmartArc plans showed similar loss of target coverage as IMRT plans. Conclusions: The position of the shoulder can have an impact on target coverage and critical structure dose. Shoulder position may need to be considered for setup of head and neck patients depending on target location.
Resumo:
Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into the phantom material. Two treatment plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility of ±3%. The hypothesis was accepted and the phantom was found to be suitable for remote audits of proton therapy treatment facilities.
Resumo:
Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.
Resumo:
Apoptosis, a form of programmed cell death, is critical to homoeostasis, normal development, and physiology. Dysregulation of apoptosis can lead to the accumulation of unwanted cells, such as occurs in cancer, and the removal of needed cells or disorders of normal tissues, such as heart, neurodegenerative, and autoimmune diseases. Noninvasive detection of apoptosis may play an important role in the evaluation of disease states and response to therapeutic intervention for a variety of diseases. It is desirable to have an imaging method to accurately detect and monitor this process in patients. In this study, we developed annexin A5-conjugated polymeric micellar nanoparticles dual-labeled with a near-infrared fluorescence fluorophores (Cy7) and a radioisotope (111In), named as 111In-labeled annexin A5-CCPM. In vitro studies demonstrated that annexin A5-CCPM could strongly and specifically bind to apoptotic cells. In vivo studies showed that apoptotic tissues could be clearly visualized by both single photon emission computed tomography (SPECT) and fluorescence molecular tomography (FMT) after intravenous injection of 111In-labeled Annexin A5-CCPM in 6 different apoptosis models. In contrast, there was little signal in respective healthy tissues. All the biodistribution data confirmed imaging results. Moreover, histological analysis revealed that radioactivity count correlated with fluorescence signal from the nanoparticles, and both signals co-localized with the region of apoptosis. In sum, 111In-labeled annexin A5-CCPM allowed visualization of apoptosis by both nuclear and optical imaging techniques. The complementary information acquired with multiple imaging techniques should be advantageous in improving diagnostics and management of patients.
Resumo:
Background and purpose. Sialyl-Tn(STn) represents an aberrantly glycosylated mucin epitope which is expressed in breast cancer and other adenocarcinomas and is an important target for the development of novel immunotherapeutic approaches. It is a marker of adverse prognosis in colon and ovarian cancer, but information about its prognostic impact in breast cancer is limited. The primary aim of the present study was to investigate the influence of STn expression on outcome of invasive breast cancer in 207 women who received anthracyline-containing adjuvant chemotherapy in a prospective clinical trial.^ Methods. Expression of STn was determined by an immunohistochemical procedure using the B72.3 monoclonal antibody. The extent of staining was determined by two observers using a 0 through 4 point scale, with 0 representing $<$5% of cells staining; 1: 5-25%; 2: 26-50%; 3: 51-75%; and 4: $>$75%. Intraobserver and interobserver agreement was.78-.92 (kappa). Kaplan-Meier and Cox proportional regression survival analyses were used to compare STn-negative and STn-positive patients.^ Results. Forty-eight (23%) of the 207 specimens demonstrated positive staining of STn. With a median follow-up of five years, STn-positivity was associated with a higher 5-year recurrence-free survival time than STn-negativity (67% vs. 80%, respectively; p = 0.03). STn expression was significantly associated with menopausal status (p = 0.04) but not other conventional prognostic markers. The risk of breast cancer recurrence and death was assessed by multivariate Cox regression analyses with adjustment for lymph node status, tumor size, menopausal status, hormone receptor status, nuclear grade, S-phase fraction and ploidy. In the final multivariate model for recurrence-free survival, the three factors that showed prognostic significance were: lymph node status (hazard ratio (HR) 3.04, 95% confidence interval (CI) 1.08-8.49), STn expression (HR 2.02, 95% CI 1.09-3.73), and tumor size (HR 1.96, 95% CI 1.05-3.64). STn was also associated with worse overall survival (HR 2.16, 95% CI 0.95-4.92) in multivariate analysis.^ Conclusion. STn antigen was shown to be a predictor of poor outcome in breast cancer. This tumor-associated antigen may be a valuable marker for identifying individuals at high risk of developing recurrent disease who may benefit from adjuvant therapy targeted at STn following definitive local therapy. Further study is needed to clarify the biologic and prognostic role of STn in breast cancer. ^
Resumo:
Background: One reason for the decision to delay the introduction of an Attenuated Psychosis Syndrome in the main text of the fifth edition of the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders was the concern that attenuated psychotic symptoms (APS) might in fact be common features in adolescents and young adults from the general population of no psychopathological significance in themselves. This concern was based on reports of high prevalence rates of psychotic-like experiences (PLEs) in the general population and the assumption that PLEs are a good estimate of APS. Although the criterion validity of self-reported PLEs had already been studied with respect to clinician-rated psychotic symptoms and found insufficient, it had been argued that PLEs might in fact be more comparable with mild, subclinical expressions of psychotic symptoms and, therefore, with APS. The present paper is the first to specifically study this assumption. Sampling and Methods: The sample consisted of 123 persons seeking help at a service for the early detection of psychosis, of whom 54 had an at-risk mental state or psychosis, 55 had a nonpsychotic mental disorder and 14 had no full-blown mental disorder. PLEs were assessed with the Peters Delusion Inventory and the revised Launay-Slade Hallucination Scale, and psychotic symptoms and APS were assessed with the Structured Interview for Prodromal Syndromes. Results: At a level of agreement between the presence of any PLE (in 98.4% of patients) and any APS (in 40.7%) just exceeding chance (κ = 0.022), the criterion validity of PLEs for APS was insufficient. Even if additional qualifiers (high agreement or distress, preoccupation and conviction) were considered, PLEs (in 52.8%) still tended to significantly overestimate APS, and agreement was only fair (κ = 0.340). Furthermore, the group effect on PLE prevalence was, at most, moderate (Cramer's V ≤ 0.382). Conclusions: The prevalence of APS cannot be deduced from studies of PLEs. Thus, the high population prevalence rate of PLEs does not allow the conclusion that APS are common features of no pathological significance and would lack clinical validity as an Attenuated Psychosis Syndrome in the Diagnostic and Statistical Manual of Mental Disorders, 5th edition. Rather, the population prevalence rate of APS has to be assumed to be largely unknown at present but is likely lower than indicated by epidemiological studies of PLEs. Therefore, dedicated studies are warranted, in which APS are assessed in a way that equates to their clinical evaluation.
Resumo:
BACKGROUND Disrupted sleep is a common complaint of individuals with alcohol use disorder and in abstinent alcoholics. Furthermore, among recovering alcoholics, poor sleep predicts relapse to drinking. Whether disrupted sleep in these populations results from prolonged alcohol use or precedes the onset of drinking is not known. The aim of this study was to examine the sleep electroencephalogram (EEG) in alcohol-naïve, parental history positive (PH+), and negative (PH-) boys and girls. METHODS All-night sleep EEG recordings in 2 longitudinal cohorts (child and teen) followed at 1.5 to 3 year intervals were analyzed. The child and teen participants were 9/10 and 15/16 years old at the initial assessment, respectively. Parental history status was classified by Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria applied to structured interviews (DIS-IV) resulting in 14 PH- and 10 PH+ children and 14 PH- and 10 PH+ teens. Sleep data were visually scored in 30-second epochs using standard criteria. Power spectra were calculated for EEG derivations C3/A2, C4/A1, O2/A1, O1/A2 for nonrapid eye movement (NREM) and rapid eye movement (REM) sleep. RESULTS We found no difference between PH+ and PH- individuals in either cohort for any visually scored sleep stage variable. Spectral power declined in both cohorts across assessments for NREM and REM sleep in all derivations and across frequencies independent of parental history status. With regard to parental history, NREM sleep EEG power was lower for the delta band in PH+ teens at both assessments for the central derivations. Furthermore, power in the sigma band for the right occipital derivation in both NREM and REM sleep was lower in PH+ children only at the initial assessment. CONCLUSIONS We found no gross signs of sleep disruption as a function of parental history. Modest differences in spectral EEG power between PH+ and PH- children and teens indicate that a marker of parental alcohol history may be detectable in teens at risk for problem drinking.