Understanding the impact of political violence on child maladjustment is a matter of international concern. Recent research has advanced a social ecological explanation for relations between political violence and child adjustment. However, conclusions are qualified by the lack of longitudinal tests. Toward examining pathways longitudinally, mothers and their adolescents (M = 12.33, SD = 1.78, at Time 1) from 2-parent families in Catholic and Protestant working class neighborhoods in Belfast, Northern Ireland, completed measures assessing multiple levels of a social ecological model. Utilizing autoregressive controls, a 3-wave longitudinal model test (T1, n = 299; T2, n = 248; T3, n = 197) supported a specific pathway linking sectarian community violence, family conflict, childrens insecurity about family relationships, and adjustment problems.
Resumo:
This paper presents experimental tests carried out on steel fibre reinforced concrete samples, including mechanical tests as well as non-destructive technique (electrical resistivity) and non destructive technique on cores (X-ray). Electrical resistivity measurements are done as a blind test, to characterise the electrical anisotropy and deduce the distribution and the orientation of fibres. These results are compared to X-ray imaging to check the quality of the non destructive evaluation. Then, flexural and compressive strength are measured on specimens to assess the influence of fibre distribution on the concrete properties.
Resumo:
The results of 82 web crippling tests are presented, with 20 tests conducted on channel sections without web openings and 62 tests conducted on channel sections with web openings. The tests consider both end-two-flange and interior-two-flange loading conditions. In the case of the tests with web openings, the hole was located directly under the concentrated load. The concentrated load was applied through bearing plates; the effect of different bearing lengths is investigated. In addition, the cases of both flanges fastened and unfastened to the support is considered. A non-linear elasto-plastic finite element model is described, and the results compared against the laboratory test results; a good agreement was obtained in terms of both strength and failure modes.
Resumo:
We compared a disk diffusion antimicrobic susceptibility panel with plasmid DNA profiles as tests for identity of 106 isolates of coagulase-negative staphylococci cultured from the blood of 45 patients on multiple occasions. The antimicrobic panel included penicillin, oxacillin, clindamycin, trimethoprim-sulfamethoxazole, chloramphenicol, tetracycline, tobramycin, kanamycin, and gentamicin. Nineteen patterns of antimicrobic susceptibility were found. The most common pattern was present in 25% of the isolates, and at least one isolate from 31% of the patients had this pattern. Forty-seven distinct plasmid DNA profiles were found. The most common plasmid profile was present in 8.5% of the isolates, and at least one isolate from 15% of the patients had this profile. Twenty-eight patients had multiple isolates that were identical by plasmid profile analysis. Twenty-seven (96%) of these patients had isolates that were also identical by antimicrobic susceptibility. Nineteen patients had multiple isolates that were different by plasmid profile analysis. In 18 (95%) of these patients, the isolates were also different by antimicrobic susceptibility. Although plasmid DNA profile analysis is a more discriminating tool, these data confirm that a selected disk diffusion antimicrobic susceptibility panel may be used to screen multiple blood isolates of coagulase-negative staphylococci for identity or differences.
Resumo:
The aim of this study was to assess the reliability and feasibility of cycle ergometer tests in young children with cystic fibrosis (CF). Children with CF aged 6-11 years and with stable lung disease performed two cycle ergometry tests (intermittent sprint and continuous incremental) on two occasions 1 week apart. Reliability was assessed using repeated-measures ANOVA. Bias was considered to be significant at P?
Resumo:
A study undertaken at the University of Liverpool has investigated the potential for using construction and demolition waste (C&DW) derived aggregate in the manufacture of a range of precast concrete products, i.e. building and paving blocks and pavement flags. Phase III, which is reported here, investigated
concrete pavement flags. This was subsequent to studies on building and paving blocks. Recycled demolition aggregate can be used to replace newly quarried limestone aggregate, usually used in coarse (6 mm) and fine (4 mm-to-dust) gradings. The first objective was, as was the case with concrete building
and paving blocks, to replicate the process used by industry in fabricating concrete pavement flags in the laboratory. The ‘‘wet’’ casting technique used by industry for making concrete flags requires a very workable mix so that the concrete flows into the mould before it is compressed. Compression squeezes out water from the top as well as the bottom of the mould. This industrial casting procedure was successfully replicated in the laboratory by using an appropriately modified cube crushing machine and a special mould typical of what is used by industry. The mould could be filled outside of the cube crushing machine and then rolled onto a steel frame and into the machine for it to be compressed. The texture and mechanical properties of the laboratory concrete flags were found to be similar to the factory ones. The experimental work involved two main series of tests, i.e. concrete flags made with concrete- and
masonry-derived aggregate. Investigation of flexural strength was required for concrete paving flags. This is different from building blocks and paving blocks which required compressive and tensile splitting strength respectively. Upper levels of replacement with recycled demolition aggregate were determined
that produced similar flexural strength to paving flags made with newly quarried aggregates, without requiring an increase in the cement content. With up to 60% of the coarse or 40% of the fine fractions replaced with concrete-derived aggregates, the target mean flexural strength of 5.0 N/mm2 was still
achieved at the age of 28 days. There was similar detrimental effect by incorporating the fine masonry-derived aggregate. A replacement level of 70% for coarse was found to be satisfactory and also conservative. However, the fine fraction replacement could only be up to 30% and even reduced to 15% when used for mixes where 60% of the coarse fraction was also masonry-derived aggregate.
Resumo:
Intestinal permeability tests have been used to screen for a wide range of small intestinal diseases, including coeliac disease and enteric infections. Several probe molecules have been used to investigate intestinal permeability including monosaccharides, disaccharides, 51Cr-EDTA and polyethyleneglycol. While many factors may affect intestinal permeability tests, the use of two probe molecules, for example, lactulose and mannitol, and the expression of the result as a ratio minimises the effects of these extraneous factors. Rendering the test solution hyperosmolar was also found to increase the sensitivity of the test in detecting coeliac disease. Intestinal permeability is characteristically elevated in untreated coeliac disease, with a sensitivity of up to 96% for the dual sugar techniques. The reason for this is a consistent increase in the absorption of lactulose (via the paracellular route) due to increased "leakiness" of the intestine and a reduction in the absorption of mannitol (via the transcellular route) due to a reduction in surface area as a result of villous atrophy. The intestinal permeability test allows subjects to be selected for jejunal biopsy in whom the clinical features are compatible with coeliac disease and in timing a follow-up biopsy. It has been postulated that raised intestinal permeability may be involved in the pathogenesis of coeliac disease. Recently, serum measurements of the probe molecules may have a valuable role, particularly in paediatric patients. Sucrose permeability has also been proposed as an accurate marker of adult coeliac disease and shows promise as a noninvasive test.