904 resultados para bioreactor chambers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to compare the efficiency of washing and trimming broiler carcasses to reduce bacterial contamination. At the poste-visceration site, 100 broiler carcasses were collected during 4 visits to a slaughterhouse in Santa Catarina State, Brazil. Birds were from the same flock, age, and approximately 2.4 kg of weight. Groups were as follows: group 1, with fecal contamination; group 2, without fecal contamination; group 3, with fecal contamination and trimmed; group 4, with fecal contamination and washed; group 5, with fecal contamination, and washed and trimmed. Carcass washings were performed with at least 1.5 L/bird of potable water (0.5 to 1 mg/kg of residual chlorine) at room temperature (20-25 degrees C) using spray cabinets with 44 spray nozzles distributed into 2 chambers (pressure of 2 kgf/cm(2) and 4 kgf/cm(2)). Washed carcasses (trimmed or not) showed significantly (P < 0.05) lower counts of aerobic mesophiles (plate count agar) on the third evaluation, and even lower (P < 0.01) counts for total coliforms (CT) and fecal coliforms (Escherichia coli). Trimmed carcasses showed significantly lower counts (P < 0.05) for plate count agar; however, we observed higher counts for E. coli (P < 0.05). The association of both treatments (washing and trimming) showed significantly higher (P < 0.05) counts for coliforms (CT and E. coli). We can conclude that the washing method is overall more efficient than the trimming method to decontaminate chicken carcasses at the postevisceration site. Hopefully, our findings can help poultry companies to minimize production costs by applying the washing method for carcass decontamination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is imortant to be able to evaluate the cardiact size . In 1995, was proposed by Buchanan and Bücheler a new way to measure the dimensions of the cardiac silhouette. This study aims to gather several studies of the cardiac dimensions by VHS method in the right lateral recumbency of of different breeds of dogs in a single work, facilitating the assess to information. Deep chest breeds have a smaller mean VHS value than the barrel chest breeds, showing that there is a variation of the VHS values acoording to the thoracic conformation of each breed, which indicates that there is a need to recognize the specific VHS values according to the breed standard to not to interpret the cardiac measurement in a wrong way through not compatible reference values for the animal. There is the individual variation that should be taken into accont at the time of measurement. The VHS is a helper method to a radiographic evaluation of the heart, and the ultrasonography remains the gold standard for the evaluation of the cardiac chambers and other changes of the heart

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public