996 resultados para angular displacement measurement
Resumo:
A series of three-point bend tests using single edge notched testpieces of pure polycrystalline ice have been performed at three different temperatures (–20°C, –30°C and –40°C). The displacement rate was varied from 1 mm/min to 100 mm/min, producing the crack tip strain rates from about 10–3 to 10–1 s–1. The results show that (a) the fracture toughness of pure polycrystalline ice given by the critical stress intensity factor (K IC) is much lower than that measured from the J—integral under identical conditions; (b) from the determination of K IC, the fracture toughness of pure polycrystalline ice decreases with increasing strain rate and there is good power law relationship between them; (c) from the measurement of the J—integral, a different tendency was appeared: when the crack tip strain rate exceeds a critical value of 6 × 10–3 s–1, the fracture toughness is almost constant but when the crack tip strain rate is less than this value, the fracture toughness increases with decreasing crack tip strain rate. Re-examination of the mechanisms of rate-dependent fracture toughness of pure polycrystalline ice shows that the effect of strain rate is related not only to the blunting of crack tips due to plasticity, creep and stress relaxation but also to the nucleation and growth of microcracks in the specimen.
Resumo:
There are many reports in the literature regarding the effects of ionic calcium on reactions related to casein micelle stability, such as heat stability, ethanol stability and susceptibility to gelation, sediment formation and fouling. However, experimental evidence supporting these assertions is much less readily available. This paper evaluates three selective ion electrode systems for measuring ionic calcium directly in milk as well as looking at the effects on pH reduction and addition of calcium chloride. The best electrode system was the Ciba Corning 634 system, which was designed for blood but has been modified for milk. This was found to be reproducible and stable when calibrated daily and allowed direct measurements to be taken on milk in 70 s. This has been found to perform well now for 3 years. The other systems were not so useful, as they took longer to stabilize, but may be useful for higher ionic calcium concentrations, which are found in acidified milk products. Reducing the pH increased ionic calcium and reduced ethanol stability. Calcium chloride addition reduced pH, increased ionic calcium and reduced the ethanol stability. Readjusting the pH to its value before calcium addition reduced the ionic calcium, but not back to its original value. Milks from individual cows showed wide variations in their ionic calcium concentrations. This establishes the methodology for a more detailed investigation on measurement of ionic calcium in milks from individual cows and from bulk milks, to allow a better understanding of its role in casein micelle stability.
Resumo:
The relationship between acrylamide and its precursors, namely, free asparagine and reducing sugars, was studied in cakes made from potato flake, wholemeal wheat, and wholemeal rye, cooked at 180 degreesC, from 5 to 60 min. Between 5 and 20 min, major losses of asparagine, water, and total reducing sugars were accompanied by large increases in acrylamide, which maximized in all three products between 25 and 30 min, followed by a slow linear reduction. Acrylamide formation did not occur to a large degree until the moisture contents of the cakes fell below 5%. Linear relationships were observed for acrylamide formation with the residual levels of asparagine and reducing sugars for all three food materials.
Resumo:
The measures most frequently used to assess psychotic symptoms fail to reflect important dimensions. The Psychotic Symptom Rating Scale (PSYRATS) aims to capture the multidimensional nature of auditory hallucinations and delusions. Individuals (N = 276) who had recently relapsed with positive symptoms completed the auditory hallucinations and delusions PSYRATS scales. These scores were compared with the relevant items from the SAPS and PANSS, and with measures of current mood. Total scores and distribution of items of the PSYRATS scales are presented and correlated with other measures. Positive symptom items from the SAPS and PANSS reflected the more objective aspects of PSYRATS ratings of auditory hallucinations and delusions (frequency and conviction) but were relatively poor at measuring distress. A major strength of the PSYRATS scales is the specific measurement of the distress dimension of symptoms, which is a key target of psychological intervention. It is advised that the PSYRATS should not be used as a total score alone, whilst further research is needed to clarify the best use of potential subscales. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
Visuospatial attentional bias was examined in Huntington's disease (HID) patients with mild disease, asymptomatic gene-positive patients and controls. No group differences were found on the grey scales task (which is a non-motor task of visuospatial attentional bias), although patients' trinucleotide (CAG) repeat length correlated with increasing leftward bias. On the line bisection task, symptomatic patients made significantly larger leftward bisection errors relative to controls, who showed the normal slight degree of leftward error (pseudo-neglect). The asymptomatic group showed a trend for greater leftward error than controls. A subset of participants went on to have structural MRI, which showed a correlation between increased leftward error on the line bisection task and reduced density in the angular gyrus area (BA39) bilaterally. This finding is consistent with recent literature suggesting a critical role for the angular gyrus in the lateralization of visuospatial attention.
Resumo:
Background Infant development is adversely affected in the context of postnatal depression. This relationship may be mediated by both the nature of early mother-infant interactions and the quality of the home environment. Aim To establish the usefulness of the Global Ratings Scales of Mother-Infant Interaction and the Infant-Toddler version of the Home Observation for the Measurement of the Environment (IT-HOME), and to test expected associations of the measures with characteristics of the social context and with major or minor depression. Method Both assessments were administered postnatally in four European centres; 144 mothers were assessed with the Global Ratings Scales and 114 with the IT-HOME. Affective disorder was assessed by means of the Structured Clinical Interview for DSM-IV Disorders. Results Analyses of mother-infant interaction indicated no main effect for depression but maternal sensitivity to infant behaviour was associated with better infant communication, especially for women who were not depressed. Poor overall emotional support also reduced sensitivity scores. Poor support was also related to poorer IT-HOME scores, but there was no effect of depression. Conclusions The Global Ratings Scales were effectively applied but there was less evidence of the usefulness of the IT-HOME. Declaration of interest None.
Resumo:
The perceived displacement of motion-defined contours in peripheral vision was examined in four experiments. In Experiment 1, in line with Ramachandran and Anstis' finding [Ramachandran, V. S., & Anstis, S. M. (1990). Illusory displacement of equiluminous kinetic edges. Perception, 19, 611-616], the border between a field of drifting dots and a static dot pattern was apparently displaced in the same direction as the movement of the dots. When a uniform dark area was substituted for the static dots, a similar displacement was found, but this was smaller and statistically insignificant. In Experiment 2, the border between two fields of dots moving in opposite directions was displaced in the direction of motion of the dots in the more eccentric field, so that the location of a boundary defined by a diverging pattern is perceived as more eccentric, and that defined by a converging as less eccentric. Two explanations for this effect (that the displacement reflects a greater weight given to the more eccentric motion, or that the region containing stronger centripetal motion components expands perceptually into that containing centrifugal motion) were tested in Experiment 3, by varying the velocity of the more eccentric region. The results favoured the explanation based on the expansion of an area in centripetal motion. Experiment 4 showed that the difference in perceived location was unlikely to be due to differences in the discriminability of contours in diverging and converging pattems, and confirmed that this effect is due to a difference between centripetal and centrifugal motion rather than motion components in other directions. Our result provides new evidence for a bias towards centripetal motion in human vision, and suggests that the direction of motion-induced displacement of edges is not always in the direction of an adjacent moving pattern. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
A quasi-optical technique for characterizing micromachined waveguides is demonstrated with wideband time-resolved terahertz spectroscopy. A transfer-function representation is adopted for the description of the relation between the signals in the input and output port of the waveguides. The time-domain responses were discretized, and the waveguide transfer function was obtained through a parametric approach in the z domain after describing the system with an autoregressive with exogenous input model. The a priori assumption of the number of modes propagating in the structure was inferred from comparisons of the theoretical with the measured characteristic impedance as well as with parsimony arguments. Measurements for a precision WR-8 waveguide-adjustable short as well as for G-band reduced-height micromachined waveguides are presented. (C) 2003 Optical Society of America.
Resumo:
This paper investigates the extent to which clients were able to influence performance measurement appraisals during the downturn in commercial property markets that began in the UK during the second half of 2007. The sharp change in market sentiment produced speculation that different client categories were attempting to influence their appraisers in different ways. In particular, it was recognised that the requirement for open‐ended funds to meet redemptions gave them strong incentives to ensure that their asset values were marked down to market. Using data supplied by Investment Property Databank, we demonstrate that, indeed, unlisted open‐ended funds experienced sharper drops in capital values than other fund types in the last quarter of 2007, after the market turning point and at the time when redemptions were at their highest. These differences are statistically significant and cannot simply be explained by differences in portfolio composition. Client influence on appraisal forms one possible explanation of the results observed: the different pressures on fund managers resulting in different appraisal outcomes.