952 resultados para angular correlation coefficient
Resumo:
The study was arranged to manifest its objectives through preceding it with an intro-duction. Particular attention was paid in the second part to detect the physical settings of the study area, together with an attempt to show the climatic characteristics in Libya. In the third part, observed temporal and spatial climate change in Libya was investigated through the trends of temperature, precipitation, relative humidity and cloud amount over the peri-ods (1946-2000), (1946-1975), and (1976-2000), comparing the results with the global scales. The forth part detected the natural and human causes of climate change concentrat-ing on the greenhouse effect. The potential impacts of climate change on Libya were ex-amined in the fifth chapter. As a case study, desertification of Jifara Plain was studied in the sixth part. In the seventh chapter, projections and mitigations of climate change and desertification were discussed. Ultimately, the main results and recommendations of the study were summarized. In order to carry through the objectives outlined above, the following methods and approaches were used: a simple linear regression analysis was computed to detect the trends of climatic parameters over time; a trend test based on a trend-to-noise-ratio was applied for detecting linear or non-linear trends; the non-parametric Mann-Kendall test for trend was used to reveal the behavior of the trends and their significance; PCA was applied to construct the all-Libya climatic parameters trends; aridity index after Walter-Lieth was shown for computing humid respectively arid months in Libya; correlation coefficient, (after Pearson) for detecting the teleconnection between sun spot numbers, NAOI, SOI, GHGs, and global warming, climate changes in Libya; aridity index, after De Martonne, to elaborate the trends of aridity in Jifara Plain; Geographical Information System and Re-mote Sensing techniques were applied to clarify the illustrations and to monitor desertifi-cation of Jifara Plain using the available satellite images MSS, TM, ETM+ and Shuttle Radar Topography Mission (SRTM). The results are explained by 88 tables, 96 figures and 10 photos. Temporal and spatial temperature changes in Libya indicated remarkably different an-nual and seasonal trends over the long observation period 1946-2000 and the short obser-vation periods 1946-1975 and 1976-2000. Trends of mean annual temperature were posi-tive at all study stations except at one from 1946-2000, negative trends prevailed at most stations from 1946-1975, while strongly positive trends were computed at all study stations from 1976-2000 corresponding with the global warming trend. Positive trends of mean minimum temperatures were observed at all reference stations from 1946-2000 and 1976-2000, while negative trends prevailed at most stations over the period 1946-1975. For mean maximum temperature, positive trends were shown from 1946-2000 and from 1976-2000 at most stations, while most trends were negative from 1946-1975. Minimum tem-peratures increased at nearly more than twice the rate of maximum temperatures at most stations. In respect of seasonal temperature, warming mostly occurred in summer and au-tumn in contrast to the global observations identifying warming mostly in winter and spring in both study periods. Precipitation across Libya is characterized by scanty and sporadically totals, as well as high intensities and very high spatial and temporal variabilities. From 1946-2000, large inter-annual and intra-annual variabilities were observed. Positive trends of annual precipi-tation totals have been observed from 1946-2000, negative trends from 1976-2000 at most stations. Variabilities of seasonal precipitation over Libya are more strikingly experienced from 1976-2000 than from 1951-1975 indicating a growing magnitude of climate change in more recent times. Negative trends of mean annual relative humidity were computed at eight stations, while positive trends prevailed at seven stations from 1946-2000. For the short observation period 1976-2000, positive trends were computed at most stations. Annual cloud amount totals decreased at most study stations in Libya over both long and short periods. Re-markably large spatial variations of climate changes were observed from north to south over Libya. Causes of climate change were discussed showing high correlation between tempera-ture increasing over Libya and CO2 emissions; weakly positive correlation between pre-cipitation and North Atlantic Oscillation index; negative correlation between temperature and sunspot numbers; negative correlation between precipitation over Libya and Southern Oscillation Index. The years 1992 and 1993 were shown as the coldest in the 1990s result-ing from the eruption of Mount Pinatubo, 1991. Libya is affected by climate change in many ways, in particular, crop production and food security, water resources, human health, population settlement and biodiversity. But the effects of climate change depend on its magnitude and the rate with which it occurs. Jifara Plain, located in northwestern Libya, has been seriously exposed to desertifica-tion as a result of climate change, landforms, overgrazing, over-cultivation and population growth. Soils have been degraded, vegetation cover disappeared and the groundwater wells were getting dry in many parts. The effect of desertification on Jifara Plain appears through reducing soil fertility and crop productivity, leading to long-term declines in agri-cultural yields, livestock yields, plant standing biomass, and plant biodiversity. Desertifi-cation has also significant implications on livestock industry and the national economy. Desertification accelerates migration from rural and nomadic areas to urban areas as the land cannot support the original inhabitants. In the absence of major shifts in policy, economic growth, energy prices, and con-sumer trends, climate change in Libya and desertification of Jifara Plain are expected to continue in the future. Libya cooperated with United Nations and other international organizations. It has signed and ratified a number of international and regional agreements which effectively established a policy framework for actions to mitigate climate change and combat deserti-fication. Libya has implemented several laws and legislative acts, with a number of ancil-lary and supplementary rules to regulate. Despite the current efforts and ongoing projects being undertaken in Libya in the field of climate change and desertification, urgent actions and projects are needed to mitigate climate change and combat desertification in the near future.
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
In multivariate time series analysis, the equal-time cross-correlation is a classic and computationally efficient measure for quantifying linear interrelations between data channels. When the cross-correlation coefficient is estimated using a finite amount of data points, its non-random part may be strongly contaminated by a sizable random contribution, such that no reliable conclusion can be drawn about genuine mutual interdependencies. The random correlations are determined by the signals' frequency content and the amount of data points used. Here, we introduce adjusted correlation matrices that can be employed to disentangle random from non-random contributions to each matrix element independently of the signal frequencies. Extending our previous work these matrices allow analyzing spatial patterns of genuine cross-correlation in multivariate data regardless of confounding influences. The performance is illustrated by example of model systems with known interdependence patterns. Finally, we apply the methods to electroencephalographic (EEG) data with epileptic seizure activity.
Resumo:
Objective : To compare two scoring systems: the Huddart/Bodenham system (HB system) and the Bauru-BCLP yardstick (BCLP yardstick), which classify treatment outcome in terms of dental arch relationships in patients with complete bilateral cleft lip and palate (CBCLP). The predictive value of these scoring systems for treatment outcome was also evaluated. Design : Retrospective longitudinal study. Patients : Dental arch relationships of 43 CBCLP patients were evaluated at 6, 9, and 12 years. Setting : Treatment outcome in BCLP patients using two scoring systems. Main Outcome Measures : For each age group, the HB scores were correlated with the BCLP yardstick scores using Spearman's correlation coefficient. The predictive value of the two scoring systems was evaluated by backward regression analysis. Results : Intraobserver Kappa values for the BCLP yardstick scoring for the two observers were .506 and .627, respectively, and the interobserver reliability ranged from .427 and .581. The intraobserver reliability for the HB system ranged from .92 to .97 and the interobserver reliability from .88 to .96. The BCLP yardstick scores of 6 and 9 years together were predictors for the outcome at 12 years (explained variance 41.3%). Adding the incisor and lateral HB scores in the regression model increased the explained variance to 67%. Conclusions : The BCLP yardstick and the HB system are reliable scoring systems for evaluation of dental arch relationships of CBCLP patients. The HB system categorizes treatment outcome into similar categories as the BCLP yardstick. In case a more sensitive measure of treatment outcome is needed, selectively both scoring systems should be used.
Resumo:
Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.
Resumo:
This case series reports the correlation between extravascular lung water (EVLW) and the partial arterial oxygen pressure/fractional inspiratory oxygen (PaO(2)/FiO(2)) ratio in three patients with severe influenza A (H1N1)-induced respiratory failure. All patients suffered from grave hypoxia (PaO(2), 26-42 mmHg) and were mechanically ventilated using biphasic airway pressure (PEEP, 12-15 mmHg; FiO(2), 0.8-1) in combination with prone positioning at 12 hourly intervals. All patients were monitored using the PICCO system for 8-11 days. During mechanical ventilation, a total of 62 simultaneous determinations of the PaO(2)/FiO(2) ratio and EVLW were performed. A significant correlation between EVLW and the PaO(2)/FiO(2) ratio (Spearman-rho correlation coefficient, -0.852; p < 0.001) was observed. In all patients, a decrease in EVLW was accompanied by an improvement in oxygenation. Serum lactate dehydrogenase levels were elevated in all patients and significantly correlated with EVLW during the intensive care unit stay (Spearman-rho correlation coefficient, 0.786; p < 0.001). In conclusion, EVLW seems increased in patients with severe H1N1-induced respiratory failure and appears to be closely correlated with impairments of oxygenatory function.
Resumo:
Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.
Resumo:
Glycan-binding antibodies form a significant subpopulation of both natural and acquired antibodies and play an important role in various immune processes. They are for example involved in innate immune responses, cancer, autoimmune diseases, and neurological disorders. In the present study, a microsphere-based flow-cytometric immunoassay (suspension array) was applied for multiplexed detection of glycan-binding antibodies in human serum. Several approaches for immobilization of glycoconjugates onto commercially available fluorescent microspheres were compared, and as the result, the design based on coupling of end-biotinylated glycopolymers has been selected. This method requires only minute amounts of glycans, similar to a printed glycan microarray. The resulting glyco-microspheres were used for detection of IgM and IgG antibodies directed against ABO blood group antigens. The possibility of multiplexing this assay was demonstrated with mixtures of microspheres modified with six different ABO related glycans. Multiplexed detection of anti-glycan IgM and IgG correlated well with singleplex assays (Pearson's correlation coefficient r = 0.95-0.99 for sera of different blood groups). The suspension array in singleplex format for A/B trisaccharide, H(di) and Le(x) microspheres corresponded well to the standard ELISA (r > 0.94). Therefore, the described method is promising for rapid, sensitive, and reproducible detection of anti-glycan antibodies in a multiplexed format.
Resumo:
Background Existing lower-limb, region-specific, patient-reported outcome measures have clinimetric limitations, including limitations in psychometric characteristics (eg, lack of internal consistency, lack of responsiveness, measurement error) and the lack of reported practical and general characteristics. A new patient-reported outcome measure, the Lower Limb Functional Index (LLFI), was developed to address these limitations. Objective The purpose of this study was to overcome recognized deficiencies in existing lower-limb, region-specific, patient-reported outcome measures through: (1) development of a new lower-extremity outcome scale (ie, the LLFI) and (2) evaluation of the clinimetric properties of the LLFI using the Lower Extremity Functional Scale (LEFS) as a criterion measure. Design This was a prospective observational study. Methods The LLFI was developed in a 3-stage process of: (1) item generation, (2) item reduction with an expert panel, and (3) pilot field testing (n=18) for reliability, responsiveness, and sample size requirements for a larger study. The main study used a convenience sample (n=127) from 10 physical therapy clinics. Participants completed the LLFI and LEFS every 2 weeks for 6 weeks and then every 4 weeks until discharge. Data were used to assess the psychometric, practical, and general characteristics of the LLFI and the LEFS. The characteristics also were evaluated for overall performance using the Measurement of Outcome Measures and Bot clinimetric assessment scales. Results The LLFI and LEFS demonstrated a single-factor structure, comparable reliability (intraclass correlation coefficient [2,1]=.97), scale width, and high criterion validity (Pearson r=.88, with 95% confidence interval [CI]). Clinimetric performance was higher for the LLFI compared with the LEFS on the Measurement of Outcome Measures scale (96% and 95%, respectively) and the Bot scale (100% and 83%, respectively). The LLFI, compared with the LEFS, had improved responsiveness (standardized response mean=1.75 and 1.64, respectively), minimal detectable change with 90% CI (6.6% and 8.1%, respectively), and internal consistency (α=.91 and .95, respectively), as well as readability with reduced user error and completion and scoring times. Limitations Limitations of the study were that only participants recruited from outpatient physical therapy clinics were included and that no specific conditions or diagnostic subgroups were investigated. Conclusion The LLFI demonstrated sound clinimetric properties. There was lower response error, efficient completion and scoring, and improved responsiveness and overall performance compared with the LEFS. The LLFI is suitable for assessment of lower-limb function.
Resumo:
Hypersensitivity of the central nervous system is widely present in pain patients and recognized as one of the determinants of chronic pain and disability. Electronic pressure algometry is often used to explore aspects of central hypersensitivity. We hypothesized that a simple pain provocation test with a clothes peg provides information on pain sensitivity that compares meaningfully to that obtained by a well-established electronic pressure algometer. "Clinically meaningful" was defined as a medium (r = 0.3-0.5) or high (r > 0.5) correlation coefficient according to Cohen's conventions.
Resumo:
The Advanced Very High Resolution Radiometer (AVHRR) carried on board the National Oceanic and Atmospheric Administration (NOAA) and the Meteorological Operational Satellite (MetOp) polar orbiting satellites is the only instrument offering more than 25 years of satellite data to analyse aerosols on a daily basis. The present study assessed a modified AVHRR aerosol optical depth τa retrieval over land for Europe. The algorithm might also be applied to other parts of the world with similar surface characteristics like Europe, only the aerosol properties would have to be adapted to a new region. The initial approach used a relationship between Sun photometer measurements from the Aerosol Robotic Network (AERONET) and the satellite data to post-process the retrieved τa. Herein a quasi-stand-alone procedure, which is more suitable for the pre-AERONET era, is presented. In addition, the estimation of surface reflectance, the aerosol model, and other processing steps have been adapted. The method's cross-platform applicability was tested by validating τa from NOAA-17 and NOAA-18 AVHRR at 15 AERONET sites in Central Europe (40.5° N–50° N, 0° E–17° E) from August 2005 to December 2007. Furthermore, the accuracy of the AVHRR retrieval was related to products from two newer instruments, the Medium Resolution Imaging Spectrometer (MERIS) on board the Environmental Satellite (ENVISAT) and the Moderate Resolution Imaging Spectroradiometer (MODIS) on board Aqua/Terra. Considering the linear correlation coefficient R, the AVHRR results were similar to those of MERIS with even lower root mean square error RMSE. Not surprisingly, MODIS, with its high spectral coverage, gave the highest R and lowest RMSE. Regarding monthly averaged τa, the results were ambiguous. Focusing on small-scale structures, R was reduced for all sensors, whereas the RMSE solely for MERIS substantially increased. Regarding larger areas like Central Europe, the error statistics were similar to the individual match-ups. This was mainly explained with sampling issues. With the successful validation of AVHRR we are now able to concentrate on our large data archive dating back to 1985. This is a unique opportunity for both climate and air pollution studies over land surfaces.
Resumo:
In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed. First, to create a realistic working condition, the Levitronix CentriMag RBP was implanted in a sheep. All parameters from the model were physically measured and digitally acquired over a wide range of conditions, including pulsatile speed. Second, a statistical analysis of the different variables (flow, speed, and their time derivatives) based on multiple regression analysis was performed to determine the significant variables for pressure head estimation. Finally, different mathematical models were used to show the effect of time derivative terms on the performance of the models. In order to evaluate how well the estimated pressure head using different models fits the measured pressure head, root mean square error and correlation coefficient were used. The results indicate that inclusion of time derivatives of flow and speed can improve model accuracy, but only minimally.
Resumo:
OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.
Resumo:
Purpose Orthognathic surgery has the objective of altering facial balance to achieve esthetic results in patients who have severe disharmony of the jaws. The purpose was to quantify the soft tissue changes after orthognathic surgery, as well as to assess the differences in 3D soft tissue changes in the middle and lower third of the face between the 1- and 2-jaw surgery groups, in mandibular prognathism patients. Materials and Methods We assessed soft tissue changes of patients who have been diagnosed with mandibular prognathism and received either isolated mandibular surgery or bimaxillary surgery. The quantitative surface displacement was assessed by superimposing preoperative and postoperative volumetric images. An observer measured a surface-distance value that is shown as a contour line. Differences between the groups were determined by the Mann-Whitney U test. The Spearman correlation coefficient was used to evaluate a potential correlation between patients' surgical and cephalometric variables and soft tissue changes after orthognathic surgery in each group. Results There were significant differences in the middle third of the face between the 1- and 2-jaw surgery groups. Soft tissues in the lower third of the face changed in both surgery groups, but not significantly. The correlation patterns were more evident in the lower third of the face. Conclusion The overall soft tissue changes of the midfacial area were more evident in the 2-jaw surgery group. In 2-jaw surgery, significant changes would be expected in the midfacial area, but caution should be exercised in patients who have a wide alar base.
Resumo:
Tumor budding is recognized by the World Health Organization as an additional prognostic factor in colorectal cancer but remains unreported in diagnostic work due to the absence of a standardized scoring method. This study aims to assess the most prognostic and reproducible scoring systems for tumor budding in colorectal cancer. Tumor budding on pancytokeratin-stained whole tissue sections from 105 well-characterized stage II patients was scored by 3 observers using 7 methods: Hase, Nakamura, Ueno, Wang (conventional and rapid method), densest high-power field, and 10 densest high-power fields. The predictive value for clinicopathologic features, the prognostic significance, and interobserver variability of each scoring method was analyzed. Pancytokeratin staining allowed accurate evaluation of tumor buds. Interobserver agreement for 3 observers was excellent for densest high-power field (intraclass correlation coefficient, 0.83) and 10 densest high-power fields (intraclass correlation coefficient, 0.91). Agreement was moderate to substantial for the conventional Wang method (κ = 0.46-0.62) and moderate for the rapid method (κ = 0.46-0.58). For Nakamura, moderate agreement (κ = 0.41-0.52) was reached, whereas concordance was fair to moderate for Ueno (κ = 0.39-0.56) and Hase (κ = 0.29-0.51). The Hase, Ueno, densest high-power field, and 10 densest high-power field methods identified a significant association of tumor budding with tumor border configuration. In multivariate analysis, only tumor budding as evaluated in densest high-power field and 10 densest high-power fields had significant prognostic effects on patient survival (P < .01), with high prognostic accuracy over the full 10-year follow-up. Scoring tumor buds in 10 densest high-power fields is a promising method to identify stage II patients at high risk for recurrence in daily diagnostics; it is highly reproducible, accounts for heterogeneity, and has a strong predictive value for adverse outcome.