920 resultados para after heat shock
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJECTIVE: To evaluate clinical profiles, predictors of 30-day mortality, and the adherence to international recommendations for the treatment of myocardial infarction in an academic medical center hospital. METHODS: We retrospectively studied 172 patients with acute myocardial infarction, admitted in the intensive care unit from January 1992 to December 1997. RESULTS: Most patients were male (68%), white (97%), and over 60 years old (59%). The main risk factor for coronary atherosclerotic disease was systemic blood hypertension (63%). Among all the variables studied, reperfusion therapy, smoking, hypertension, cardiogenic shock, and age were the predictors of 30-day mortality. Most commonly used medications were: acetylsalicylic acid (71%), nitrates (61%), diuretics (51%), angiotensin-converting enzyme inhibitors (46%), thrombolytic therapy (39%), and beta-blockers (35%). CONCLUSION: The absence of reperfusion therapy, smoking status, hypertension, cardiogenic shock, and advanced age are predictors of 30-day mortality in patients with acute myocardial infarction. In addition, some medications that are undoubtedly beneficial have been under-used after acute myocardial infarction.
Resumo:
Heat stress has negative effects on pregnancy rates of lactating dairy cattle. There are genetic differences in tolerance to heat stress; Bos taurus indicus (B. t. indicus) cattle and embryos are more thermotolerant than Bos taurus taurus (B. t. taurus). In the present study, the effects of sire and sire breed on conception and embryonic/fetal loss rates of lactating Holstein cows during the Brazilian summer were determined. In Experiment 1, cows (n = 302) were AI after estrus detection or at a fixed-time with semen from one Gyr (B. t. indicus) or one Holstein sire (B. t. taurus). Pregnancy was diagnosed 80 days after AI. In Experiment 2, cows (n = 811) were AI with semen from three Gyr and two Holstein sires. Pregnancy was diagnosed at 30-40 and at 60-80 days after AI. Cows diagnosed pregnant at the first examination but non-pregnant at the second were considered as having lost their embryo or fetus. Data were analyzed by logistic regression. The model considered the effect of sire within breed, sire breed, days postpartum, period of lactation, and AI type (AI after estrus versus fixed-time). There was no effect of the AI type, days postpartum or milk production on conception or embryonic loss rates. The use of Gyr bulls increased pregnancy rate when compared to Holstein bulls [9.1% (60/657) versus 5.0% (23/456), respectively, P = 0.008; data from Experiments 1 and 2 combined]. Additionally, in Experiment 2, cows inseminated using semen from sire #4 (Gyr) had lower embryonic loss (10%) when compared with other B. t. indicus (35.3% and 40%) or B. t. taurus sires (18.2% and 38.5%, P = 0.03). In conclusion, the use of B. t. indicus sires may result in higher conception rates in lactating Holstein cows during summer heat stress. Moreover, sire can affect embryonic loss and selection of bulls according to this criterion may result in higher parturition rates in lactating Holstein cows. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This study evaluated the effect of heat treatment on CrNi stainless steel orthodontic archwires. Half of forty archwires of each thickness - 0.014 (0.35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) (totalling 160 archwires) - were subjected to heat treatment while the remainder were not. All of the archwires had their individual thickness measured in the anterior and posterior regions using AutoCad 2000 software before and after compressive and tensile strength testing. The data was statistically analysed utilising multivariance ANOVA at a 5% significance level. All archwires without heat treatment that were subjected to tensile strength testing presented with anterior opening, which was more accentuated in the 0.020 archwires. In the posterior region, the opening produced by the tensile force was more accentuated in the archwires without heat treatment. There was greater stability in the thermally treated archwires, especially those subjected to tensile strength testing, which indicates that the heat treatment of orthodontic archwires establishes a favourable and indispensable condition to preserve the intercanine width.
Resumo:
Objectives: This study evaluated the effect of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min) on the linear dimensional change (LDC) of four reline resins (Kooliner-K, New Truliner-N, Tokuso Rebase Fast-T, Ufi Gel Hard-U) and one heat-polymerizing denture base resin (Lucitone 550-L). Methods: Specimens (50.0 mm diameter, 0.5 mm thickness) were made using a split mold with reference points, and divided into two controls and four test groups (u = 8). The distances between the points were measured on the mold (baseline readings), and compared to those obtained from the specimens after: polymerization or immersion in water (37 degrees C) for 7 days (controls); 2 or 7 cycles of disinfection by immersion or microwave irradiation. Results: the two-way ANOVA and Tukey's test (alpha = 0.05) showed that microwave disinfection significantly increased the mean LDC of materials L (-1.43%), N (-1.27%) and K (-1.06%). Material N also exhibited a significant increase in LDC after two cycles of chemical disinfection (-0.73%). For U (-0.47%) and T (-0.21%) materials, no significant changes in LDC were found. Conclusions: Microwave disinfection increases the shrinkage of materials L, N, and K. The dimensional stability of resins U and T was not affected by the disinfection methods evaluated. (c) 2006 Wiley Periodicals, Inc.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aiming at evaluating the influence of cyclic temperatures on the performance and egg quality of Japanese quails an experiment was carried out with 480 birds after egg production peak. Birds were housed in a bioclimatic chamber with automatic temperature control that contained two rooms, one maintained at thermoneutral temperature (21 ºC) and the other adjusted for the tested cyclic temperatures (24, 27, 30, 33 and 36 ºC at a time). Each room had a battery of five floors and ten cages, with a capacity of 24 birds per cage, totaling 240 birds per battery. Birds were fed iso-nutritious and iso-caloric diets. Data obtained under the tested cyclic temperatures were compared with those obtained under thermoneutral temperature. At the end of each experimental period (14 days) performance and egg quality parameters were evaluated. A completely randomized experimental design with two treatments (thermoneutral temperature and tested temperature) and ten replicates of 24 birds each. Cyclic increases of 27 ºC and higher in environmental temperature negatively affected bird performance, with reduced feed intake and consequent reductions in egg weight and mass. A cyclic increase of the environmental temperature to 36 ºC reduced the percentage of saleable eggs and egg production.
Resumo:
A comparison of the thermal regime and oxygen distribution patterns of some Brazilian reservoirs was made. A strong latitudinal dependence of surface temperature, annual mean and annual range was found. Except for Tucurui Reservoir, a reservoir of the Equatorial zone, the lowest surface temperature of the year in the other compared reservoirs was observed from June to August while the highest extended from October to February. The decreasing trend of annual mean temperatures and thermal ranges was due to the increasing seasonal variability of insolation with the latitude. A positive relationship between the increase on thermal surface-bottom differences and the depth of water column was found for reservoirs of similar latitudes. A long thermal stratification (around four months) was evidenced in the lacustrine zone of reservoirs with a residence time higher than 40 days. Low fluctuation (<2%) of the annual variability of heat contents was observed for the Tucurui Reservoir, while in das Garcas Reservoir a manmade lake located in the frontier between tropical and temperate regions, the annual coefficient of variation attained 13%. Concerning the heat budgets, the value for the Tucurui Reservoir was two times higher than in das Garcas Reservoir. Both the morphometric and climatological factors affected the heat contents of the two compared reservoirs. In deep eutrophic reservoirs, a significant reduction on the oxygen concentrations in the hypolimnetic zone was frequently observed. In some oligotrophic stratified reservoirs, a decrease on oxygen with depth occurred when the temperature of the hypolimnion was higher than 20 degrees C and caused a biochemical oxygen demand. In das Garcas Reservoir, the actual oxygen deficits ranged from 0.40 to 1.52 mg.O-2.cm(-2) and appear to be linked to oxygen consumption after the senescence of Microcystis aeruginosa populations in the spring. But, other factors such as the allochthonous loads of organic matter also had an important role on the oxygen balance of das Garcas Reservoir.
Resumo:
Objectives. This study characterized the feldspathic ceramic surfaces after various silanization protocols.Methods. Ceramic bars (2 mm x 4 mm x 10 mm) (N = 18) of feldpathic ceramic (VM7, VITA Zahnfabrik) were manufactured and finished. Before silane application, the specimens were ultrasonically cleaned in distilled water for 10 min. The ceramic specimens were randomly divided into nine groups (N = 2 per group) and were treated with different silane protocols. MPS silane (ESPE-Sil, 3M ESPE) was applied to all specimens and left to react at 20 degrees C for 2 min (G20). After drying, the specimens were subjected to heat treatment in an oven at 38 degrees C (G38), 79 degrees C (G79) or 100 degrees C (G100) for 1 min. Half of the specimens of each group were rinsed with water at 80 degrees C for 15 s (G20B, G38B, G79B, G100B). The control group (GC) received no silane. Attenuated total reflection infrared Fourier transform analysis (ATR FT-IR) was performed using a spectrometer. Thickness of silane layer was measured using a spectroscopic ellip-someter working in the lambda = 632.8 nm (He-Ne laser) at 70 degrees incidence angle. Surface roughness was evaluated using an optical profilometer. Specimens were further analyzed under the Scanning Electron Microscopy (SEM) to observe the topographic patterns.Results. ATR FT-IR analysis showed changes in Si-O peaks with enlarged bands around 940 cm(-1). Ellipsometry measurements showed that all post-heat treatment actions reduced the silane film thickness (30.8-33.5 nm) compared to G20 (40 nm). The groups submitted to rinsing in hot water (B groups) showed thinner silane films (9.8-14.4 nm) than those of their corresponding groups (without washing) (30.8-40 nm). Profilometer analysis showed that heat treatments (Ra approximate to 0.10-0.19 mu m; Rq approximate to 0.15-0.26 mu m) provided a smoother surface than the control group (Ra approximate to 0.48 mu m; Rq approximate to 0.65 mu m). Similar patterns were also observed in SEM images.Significance. Heat treatment after MPS silane application improved the silane layer network. Rinsing with boiling water eliminated the outmost unreacted regions of the silane yielding to thinner film thicknesses. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
In this work, BSTSn powders prepared by the polymeric precursor method were heat treated in a domestic microwave oven (MW) using a SiC susceptor to absorb the microwave energy and transfer the heat to the powder. The main advantage of MW is to reduce the thermal treatment time for phase crystallization. The powders were heat treated at 300 degrees C for 20 h in conventional oven, 300 degrees C for 10 min, 20 min, and 30 min in MW and at 500 degrees C for 1 min in MW. After thermal treatment, the photoluminescent properties of powders at room temperature were analyzed. (c) 2007 Published by Elsevier B.V.
Resumo:
The influence of heat-treatments on the electrochemical behavior of thermal spray Cr3C2-NiCr coatings prepared by high velocity oxygen fuel (HVOF) was studied in NaCl solution, at 25 degrees C, using open-circuit potential (E-OC) and electrochemical impedance spectroscopy (EIS) measurements. Coating characterization were performed before and after the heat-treatments and electrochemical tests by scanning electron microscopy, X-ray diffraction, and Auger electron spectroscopy. In addition to the changes in the original powder composition occurring during HVOF process, heat-treatment performed at 450 degrees C caused no significant changes in electrochemical response compared with untreated sample, and at 760 degrees C the main difference was the formation of a thin and defective layer of Cr2O3 at the coating surface, which increased the total impedance at the first day of immersion. Higher influence on the electrochemical was noted for samples treated at 880 degrees C, which also showed higher E-OC and total impedance, and lower corrosion current. This behavior was interpreted considering the formation of a chromium oxide layer on the coating surface, dissolution and decomposition of smaller carbide particles and their surface enrichment with Cr due to C diffusion and dissolution into the matrix, and possible Ni, Cr, and Fe diffusion to coating/substrate interface. (c) 2006 the Electrochemical Society.