981 resultados para Venous Thromboembolism


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with Ebstein's anomaly can present after childhood or adolescence with cyanosis, arrhythmias, severe right ventricular dysfunction and frequently with left ventricular dysfunction secondary to the prolonged cyanosis and to the right ventricular interference. At this point conventional repair is accompanied by elevated mortality and morbidity and poor functional results. We report our experience with three patients (8, 16 and 35 years of age) with Ebstein's anomaly, very dilated right atrium, severe tricuspid valve regurgitation (4/4), bi-directional shunt through an atrial septal defect and reduced left ventricular function (mean ejection fraction = 58%, mean shortening fraction = 25%). All underwent one and a half ventricular repair consisting of closure of the atrial septal defect, tricuspid repair with reduction of the atrialised portion of the right ventricle and end-to-side anastomosis of the superior vena cava to the right pulmonary artery. All patients survived, with a mean follow-up of 33 months. In all there was complete regression of the cyanosis and of the signs of heart failure. Postoperative echocardiography showed reduced degree of tricuspid regurgitation (2/4) and improvement of the left ventricular function (mean ejection fraction = 77%, mean shortening fraction = 40%). In patients with Ebstein's anomaly referred late for surgery with severely compromised right ventricular function or even with reduced biventricular function, the presence of a relatively hypoplastic and/or malfunctioning right ventricular chamber inadequate to sustain the entire systemic venous return but capable of managing part of the systemic venous return, permits a one and a half ventricular repair with good functional results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To demonstrate successful in situ aortoiliac reconstruction of an infected infrarenal aneurysm using one single superficial femoral vein (SFV). Methods: In situ reconstruction using the right SFV sutured in end-to-end anastomosis with the aorta and distally with the right common iliac artery and in end-to-side anastomosis with the left common iliac artery. Results: The operating time was less than reported for aortic in situ reconstruction with bilateral SFV harvesting. The duplex scan 3 months postoperatively showed permeability of the bypass without any anastomotic stenosis or pseudoaneurysm. The right common femoral, popliteal, and greater saphenous veins were patent without thrombus, and the patient did not complain about peripheral edema. Conclusions: The use of only one instead of both the SFVs for aortobiiliac in situ reconstruction might be a way to reduce operating time and allow autogenous venous reconstruction even in patients with limited availability of venous material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is the most common cardiac arrhythmia. The risk of thromboembolic events is important, and at that time, there is no definite treatment for AF. Oral anticoagulation also represents a hemorrhagic risk factor. Ninety percent of atrial thrombi are located within the left atrial appendage. The percutaneous closure of this left atrial appendage with a device has been shown to decrease thromboembolic events even after interruption of oral anticoagulation as compared to warfarin in a recent randomized study. Recent data support this innovative technique as a reasonable alternative to long term anticoagulation in patients at high risk of bleeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La thrombose veineuse superficielle (TVS) se caractérise cliniquement par un cordon induré, rouge, chaud et douloureux résultant d'un processus inflammatoire et de la présence d'un thrombus entraînant l'occlusion d'une veine superficielle. La TVS des membres inférieurs est le plus souvent considérée comme relativement bénigne et habituellement traitée par antiinflammatoires et compression élastique. Cependant, la TVS peut être associée à d'autres tableaux pathologiques tels la thrombose veineuse profonde requerrant dans certains cas des investigations complémentaires. Mots-clés:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: There is a trend towards surgical treatment of acute ruptured Achilles tendon. While classical open surgical procedures have been shown to restore good functional capacity, they are potentially associated with significant complications like wound infection and paresthesia. Modern mini-invasive surgical techniques significantly reduce these complications and are also associated with good functional results so that they can be considered as the surgical treatment of choice. Nevertheless, there is still a need for conservative alternative and recent studies report good results with conservative treatment in rigid casts or braces. PATIENTS/METHOD: We report the use of a dynamic ankle brace in the conservative treatment of Achilles tendon rupture in a prospective non-randomised study of 57 consecutive patients. Patients were evaluated at an average follow-up time of 5 years using the modified Leppilahti Ankle Score, and the first 30 patients additionally underwent a clinical examination and muscular testing with a Cybex isokinetic dynamometer at 6 and 12 months. RESULTS: We found good and excellent results in most cases. We observed five complete re-ruptures, almost exclusively in case of poor patient's compliance, two partial re-ruptures and one deep venous thrombosis complicated by pulmonary embolism. CONCLUSION: Although prospective comparison with other modern treatment options is still required, the functional outcome after early ankle mobilisation in a dynamic cast is good enough to ethically propose this method as an alternative to surgical treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective.-Suspension trauma refers to the pathophysiologic syndrome that occurs when a victim is suspended motionless in a vertical position for an extended period of time. This can occur in sports that use a harness system as well as in various occupational activities including work on high wires or helicopter rescue operations. We reviewed the scientific evidence published to date in order to improve the prevention and treatment of suspension trauma.Methods.-Medline, PreMedline, the Cochrane Library, and Google Scholar were searched for relevant information about suspension trauma.Results.-Published data describing the pathophysiology of and the therapeutic approach to suspension trauma are sparse and consist mainly of case reports and a limited number of human experimental prospective studies. The pathophysiology of suspension trauma is related to hypovolemia induced by reduced venous return and by vagal stimulation. It is also influenced by the type of harness used. Chest harnesses may induce severe cardiorespiratory repercussions and have the lowest motionless suspension tolerance. Symptoms of suspension trauma include presyncope and can lead to a loss of consciousness.Conclusions.-Sports enthusiasts and workers who use a body harness system should never act alone and should not use a simple chest harness. If a victim shows symptoms of presyncope or is unconscious, he should be released from suspension as soon as is safely possible. There is no clear evidence to support the idea that the return to the horizontal position may contribute to the potential risk of rescue death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to adapt and improve a minimally invasive two-step postmortem angiographic technique for use on human cadavers. Detailed mapping of the entire vascular system is almost impossible with conventional autopsy tools. The technique described should be valuable in the diagnosis of vascular abnormalities. MATERIALS AND METHODS: Postmortem perfusion with an oily liquid is established with a circulation machine. An oily contrast agent is introduced as a bolus injection, and radiographic imaging is performed. In this pilot study, the upper or lower extremities of four human cadavers were perfused. In two cases, the vascular system of a lower extremity was visualized with anterograde perfusion of the arteries. In the other two cases, in which the suspected cause of death was drug intoxication, the veins of an upper extremity were visualized with retrograde perfusion of the venous system. RESULTS: In each case, the vascular system was visualized up to the level of the small supplying and draining vessels. In three of the four cases, vascular abnormalities were found. In one instance, a venous injection mark engendered by the self-administration of drugs was rendered visible by exudation of the contrast agent. In the other two cases, occlusion of the arteries and veins was apparent. CONCLUSION: The method described is readily applicable to human cadavers. After establishment of postmortem perfusion with paraffin oil and injection of the oily contrast agent, the vascular system can be investigated in detail and vascular abnormalities rendered visible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS: In a controlled clinical trial, 48 patients (mean age 50 ± 21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N = 24) or conventional catheter-directed thrombolysis (N = 24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55% ± 27% in the ultrasound-assisted catheter-directed thrombolysis group and 54% ± 27% in the conventional catheter-directed thrombolysis group (P = 0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P > 0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P > 0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P = 0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0 ± 3.9 [range 0-15] versus 1.9 ± 1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS: In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:: To assess the overall burden of healthcare-associated infections (HAIs) in patients exposed and nonexposed to surgery. BACKGROUND:: Targeted HAI surveillance is common in healthcare institutions, but may underestimate the overall burden of disease. METHODS:: Prevalence study among patients hospitalized in 50 acute care hospitals participating in the Swiss Nosocomial Infection Prevalence surveillance program. RESULTS:: Of 8273 patients, 3377 (40.8%) had recent surgery. Overall, HAI was present in 358 (10.6%) patients exposed to surgery, but only in 206 (4.2%) of 4896 nonexposed (P < 0.001). Prevalence of surgical site infection (SSI) was 5.4%. Healthcare-associated infections prevalence excluding SSI was 6.5% in patients with surgery and 4.7% in those without (P < 0.0001). Patients exposed to surgery carried less intrinsic risk factors for infection (age >60 years, 55.6% vs 63.0%; American Society of Anesthesiologists score >3, 5.9% vs 9.3%; McCabe for rapidly fatal disease, 3.9% vs 6.6%; Charlson comorbidity index >2, 12.3% vs 20.9%, respectively; all P < 0.001) than those nonexposed, but more extrinsic risk factors (urinary catheters, 39.6% vs 14.1%; central venous catheters, 17.8% vs 7.1%; mechanical ventilation, 4.7% vs 1.3%; intensive care stay, 18.3% vs 8.8%, respectively; all P < 0.001). Exposure to surgery independently predicted an increased risk of HAI (odds ratio 2.43; 95% CI 2.0-3.0). CONCLUSIONS:: Despite a lower intrinsic risk, patients exposed to surgery carried more than twice the overall HAI burden than those nonexposed; almost half was accountable to SSI. Extending infection control efforts beyond SSI prevention in these patients might be rewarding, especially because of the extrinsic nature of risk factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our goal was to evaluate the diagnostic utility of C-reactive protein (CRP) alone or combined with clinical probability assessment in patients with suspected pulmonary embolism (PE), and to compare its performance to a D-dimer assay. We conducted a prospective study in which we performed a common immuno-turbidimetric CRP test and a rapid enzyme-linked immunosorbent assay (ELISA) D-dimer test in 259 consecutive outpatients with suspected PE at the emergency department of a teaching hospital. We assessed clinical probability of PE by a validated prediction rule overridden by clinical judgment. Patients with D-dimer levels &gt; or = 500 microg/l underwent a work-up consisting of lower-limb venous ultrasound, spiral computerized tomography, ventilation-perfusion scan, or pulmonary angiography. Patients were followed up for three months. Seventy-seven (30%) of the patients had PE. The CRP alone had a sensitivity of 84% (95% confidence interval [CI).: 74 to 92%) and a negative predictive value (NPV) of 87% (95% CI: 78 to 93%) at a cutpoint of 5 mg/l. Overall, 61 (24%) patients with a low clinical probability of PE had a CRP &lt; 5 mg/l. Due to the low prevalence of PE (9%) in this subgroup, the NPV increased to 97% (95% CI: 89 to 100%). The D-dimer (cutpoint 500 micro g/l) showed a sensitivity of 100% (95% CI: 95 to 100%) and a NPV of 100% (95% CI: 94 to 100%) irrespective of clinical probability and accurately rule out PE in 56 (22%) patients. Standard CRP tests alone or combined with clinical probability assessment cannot safely exclude PE.