938 resultados para ULTRASOUND-GUIDED BIOPSY
Resumo:
Abstract Background Brazilian propolis type 6 (Atlantic forest, Bahia) is distinct from the other types of propolis especially due to absence of flavonoids and presence of other non-polar, long chain compounds, but presenting good in vitro and in vivo antimicrobial activity. Several authors have suggested that fatty acids found in this propolis might be responsible for its antimicrobial activity; however, so far no evidence concerning this finding has been reported in the literature. The goals of this study were to evaluate the antibacterial activity of the main pure fatty acids in the ethanolic extract and fractions and elucidate the chemical nature of the bioactive compounds isolated from Brazilian propolis type 6. Methods Brazilian propolis type 6 ethanolic extract (EEP), hexane fraction (H-Fr), major fatty acids, and isolated sub-fractions were analyzed using high performance liquid chromatography (HPLC), high resolution gas chromatography with flame ionization detection (HRGC-FID), and gas chromatography-mass spectrometry (GC-MS). Three sub-fractions of H-Fr were obtained through preparative HPLC. Antimicrobial activity of EEP, H-Fr, sub-fractions, and fatty acids were tested against Staphyloccus aureus ATCC 25923 and Streptococcus mutans Ingbritt 1600 using minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC). Results EEP and H-Fr inhibited the growth of the microorganisms tested; nevertheless, no antimicrobial activity was found for the major fatty acids. The three sub-fractions (1, 2, and 3) were isolated from H-Fr by preparative HPLC and only sub-fraction 1 showed antimicrobial activity. Conclusion a) The major fatty acids tested were not responsible for the antimicrobial activity of propolis type 6; b) Sub-fraction 1, belonging to the benzophenone class, was responsible for the antimicrobial activity observed in the present study. The identification of the bioactive compound will improve the development of more efficient uses of this natural product.
Resumo:
Abstract Background Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.
Resumo:
There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.
Resumo:
Computed tomography (CT)-guided percutaneous drilling is an alternative for osteoid osteoma treatment. This study aims to evaluate the remodeling of the drill orifice. The success rate and complications were also recorded and compared with other treatment methods.
Resumo:
The treatment of hemorrhoidal disease (HD) by conventional hemorrhoidectomy is associated with significant morbidity, mainly represented by the postoperative pain and the late return to daily activities. Doppler-guided hemorrhoid artery ligation (DGHAL) is a minimal-invasive surgical treatment for HD that has been used as an alternative method in order to reduce these inconveniences. OBJECTIVE: To analyze the initial results of the DGHAL technique associated with rectal mucopexy in the treatment of HD. METHODS:Forty-two patients with stage I, III and IV hemorrhoids who were submitted to DGHAL were analyzed from December 2010 to August 2011. Eleven patients (26%) were stage II; 21 (50%), stage III; and 10 (24%), stage IV HD. All patients were operated by the same surgeon under spinal anesthesia and using the same equipment and technique to perform the procedure. The 42 patients underwent ligation of six arterial branches followed by rectal mucopexia by uninterrupted suture. Nine patients needed concomitant removal of perianal skin tag. In the postoperative, the following parameters were evaluated: pain, tenesmus, bleeding, itching, prolapse, mucus discharge and recurrence. The mean postoperative follow-up lasted four months (one to nine months). RESULTS: Tenesmus was the most common postoperative complaint for 85.7% of patients followed by pain, in 28.6%, perianal burning, in 12.3%, mucus discharge and perianal hematoma in 4.7%. Two patients had severe postoperative bleeding and required surgical haemostasis, one of which needed blood transfusion. Ninety-five percent of the patients declared to be satisfied with the method. CONCLUSION: Even though DGHAL has complications similar to those of other surgical methods, its results present less postoperative pain, allowing faster recovery and return to work. Studies with more cases and a longer follow-up are still necessary to assess the late recurrence.
Resumo:
Background: In the feline species, 80% to 93% of neoplasias in the mammary gland are malignant, being the majority carcinomas. Among them, there is the mammary squamous cell carcinoma, which amounts to a very rare neoplasm in the domestic cat, with considerable potential for malignancy. This study aimed to report a case of squamous cell mammary carcinoma in the feline species. Case: A female cat, mixed breed, ten years old, presented history of skin lesion. The cat had been spayed two years before, but with previous administration of contraceptives. At the physical examination, it was observed ulcer between the caudal abdominal mammary glands. The occurrence of skin or mammary neoplasia was conceived. The following complementary tests were requested: complete blood count, serum biochemical profi le (renal and hepatic), chest radiographs, abdominal ultrasound, and incisional biopsy of the ulcerated region periphery, followed by classic histopathology. The lesion histopathology was compatible with squamous cell carcinoma of the mammary gland. Due to such a diagnosis, bilateral mastectomy was recommended. The material obtained during the surgical procedure was sent for anatomopathological analysis. Microscopically, surgical margins infi ltration and a regional lymph node were verifi ed. The owner was advised of the need for complementary therapies and medical monitoring of the cat. However, there was no return. It is noteworthy that the animal’s physical and laboratory examinations showed no neoplasia in other regions, being the squamous cell carcinoma of the mammary gland considered primary. Discussion: The malignant mammary neoplasia genesis in feline species, in general, seems to be related to steroid hormones. The ovariectomized females are less likely to develop the disease when compared to intact cats, but there is no protective effect of surgery on those spayed after two years of age regarding the appearance of the neoplasia. Thus, at the time the reported patient was ovariectomized, this effect no longer occurred. The synthetic progestins regularly used to prevent estrus increase by three times the risk of breast carcinomas onset. In humans, there is no clear defi nition of the etiology and pathogenesis of mammary squamous cell carcinoma. However, it has been suggested its association with extreme forms of squamous metaplasia present in pre-existing mammary adenocarcinoma, besides cysts, chronic infl ammations, abscesses and mammary gland adenofi bromas. In a hypothetical way, this etiology could also be related to the feline mammary carcinoma, although, for the case at issue, the exogenous and endogenous hormonal infl uence should not be excluded. It has been reported that mammary squamous cell carcinomas in cats are classifi ed in grades II and III (ie, moderately and poorly differentiated, respectively). Thus, they are considered tumors with more unfavorable prognosis. However, the monitoring of the clinical course, in order to evaluate possible recurrence of the neoplasia and metastases to distant sites, was not possible as the animal under discussion did not return. The squamous cell carcinoma is the most common skin tumor in feline species, despite the primary location in the mammary gland. It is, therefore, important to differentiate squamous cell carcinoma originated in the breast from histological types derived from skin. The description of this special and rare feline mammary carcinoma is important due to its particular characteristics and potential for malignancy.
Resumo:
[EN] OBJECTIVE: To determine the value of ultrasonography in the assessment of patients with idiopathic carpal tunnel syndrome (CTS) and poor outcome after carpal tunnel release. METHODS: A total of 88 consecutive patients with CTS (104 hands) underwent open surgical release of the median nerve. Ultrasound (US) examination was performed blind to any patient's data. The median nerve area at tunnel inlet and outlet, the retinaculum distance, and the flattening ratio were measured. The main outcome variable was the patient's overall satisfaction using a five-point Likert scale (1 = worse, 2 = no change, 3 = slightly better, 4 = much better, 5 = cured) at 3 months postoperatively. Pre- and postoperative ultrasonographic findings in relation to clinical outcome were analysed. RESULTS: Improvement (scores 4 or 5 on the Likert scale) was recorded in 75 hands (72%). After carpal tunnel release, the cross-sectional area at tunnel inlet decreased from a mean of 14.2 to 13.3 mm2 in the group with clinical improvement and also from a mean of 12.5 to 11.6 mm2 in the group with no change or slight improvement. No significant changes in the cross-sectional area at tunnel outlet, retinaculum distance, and flattening ratio were observed. CONCLUSION: Reduction of the median nerve cross-sectional area at tunnel inlet at 3 months after carpal tunnel release was similar in patients reporting cure or great improvement and in those with slight or no improvement. Ultrasonography is of limited value in assessment of patients with poor outcome after median nerve release.
Resumo:
Aim of the present study was to evaluate the accuracy of transrectal ultrasound biopsy (TRUS-biopsy) directed to regions with abnormal MRI and/or MRSI (magnetic resonance spectroscopic imaging ) for both the transition (TZ) and the peripheral (PZ) zones in patients who presented with persistent suspect for prostate cancer and with prior negative biopsy. We also evaluated relationship between MRSI results and histopathological findings of biopsy. 54 patients with the aforementioned characteristics underwent MRI/MRSI at least 6 months after prior negative biopsy; interval between MRI/3D-MRSI and the further TRUS-biopsy was less than 3 months. The prostate was divided in 12 regions both for imaging interpretation and biopsy. Moreover one to three cores more were taken from each region with abnormal MRI and/or 3D-MRSI. Twenty-two out of 54 patients presented cancer at MRI/MRSI-directed-TRUS-biopsy. On a patient basis the highest accuracy was obtained by assigning malignancy on a positive finding with MRSI and MRI even though it was not significantly greater than that obtained using MRI alone (area under the ROC curve, AUC: 0.723 vs. 0.676). On a region (n=648) basis the best accuracy was also obtained by considering positive both MRSI and MRI for PZ (0.768) and TZ (0.822). Twenty-eight per cent of cores with prostatitis were false positive findings on MRSI, whereas only 2.7% of benign prostatic hyperplasia was false positive. In conclusion the accuracy of MRI/MRSI-directed biopsies in localization of prostate cancer is good in patient and region analyses. The combination of both MRI and MRSI results makes TRUS-biopsy more accurate particularly in the TZ (0.822) for patients with prior negative biopsies. Histopathological analysis showed that the main limitation of MRSI is the percentage of false positive findings due to prostatitis.
Resumo:
This thesis introduces new processing techniques for computer-aided interpretation of ultrasound images with the purpose of supporting medical diagnostic. In terms of practical application, the goal of this work is the improvement of current prostate biopsy protocols by providing physicians with a visual map overlaid over ultrasound images marking regions potentially affected by disease. As far as analysis techniques are concerned, the main contributions of this work to the state-of-the-art is the introduction of deconvolution as a pre-processing step in the standard ultrasonic tissue characterization procedure to improve the diagnostic significance of ultrasonic features. This thesis also includes some innovations in ultrasound modeling, in particular the employment of a continuous-time autoregressive moving-average (CARMA) model for ultrasound signals, a new maximum-likelihood CARMA estimator based on exponential splines and the definition of CARMA parameters as new ultrasonic features able to capture scatterers concentration. Finally, concerning the clinical usefulness of the developed techniques, the main contribution of this research is showing, through a study based on medical ground truth, that a reduction in the number of sampled cores in standard prostate biopsy is possible, preserving the same diagnostic power of the current clinical protocol.
Resumo:
Aim: To evaluate the early response to treatment to an antiangiogenetic drug (sorafenib) in a heterotopic murine model of hepatocellular carcinoma (HCC) using ultrasonographic molecular imaging. Material and Methods: the xenographt model was established injecting a suspension of HuH7 cells subcutaneously in 19 nude mice. When tumors reached a mean diameter of 5-10 mm, they were divided in two groups (treatment and vehicle). The treatment group received sorafenib (62 mg/kg) by daily oral gavage for 14 days. Molecular imaging was performed using contrast enhanced ultrasound (CEUS), by injecting into the mouse venous circulation a suspension of VEGFR-2 targeted microbubbles (BR55, kind gift of Bracco Swiss, Geneve, Switzerland). Video clips were acquired for 6 minutes, then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated software (Sonotumor, Bracco Swiss) to quantify the signal of the contrast agent. Time/intensity curves were obtained and the difference of the mean MBs signal before and after high MI impulse (Differential Targeted Enhancement-dTE) was calculated. dTE represents a numeric value in arbitrary units proportional to the amount of bound MBs. At day +14 mice were euthanized and the tumors analyzed for VEGFR-2, pERK, and CD31 tissue levels using western blot analysis. Results: dTE values decreased from day 0 to day +14 both in treatment and vehicle groups, and they were statistically higher in vehicle group than in treatment group at day +2, at day +7, and at day +14. With respect to the degree of tumor volume increase, measured as growth percentage delta (GPD), treatment group was divided in two sub-groups, non-responders (GPD>350%), and responders (GPD<200%). In the same way vehicle group was divided in slow growth group (GPD<400%), and fast growth group (GPD>900%). dTE values at day 0 (immediately before treatment start) were higher in non-responders than in responders group, with statistical difference at day 2. While dTE values were higher in the fast growth group than in the slow growth group only at day 0. A significant positive correlation was found between VEGFR-2 tissue levels and dTE values, confirming that level of BR55 tissue enhancement reflects the amount of tissue VEGF receptor. Conclusions: the present findings show that, at least in murine experimental models, CEUS with BR55 is feasable and appears to be a useful tool in the prediction of tumor growth and response to sorafenib treatment in xenograft HCC.
Resumo:
In this thesis two major topics inherent with medical ultrasound images are addressed: deconvolution and segmentation. In the first case a deconvolution algorithm is described allowing statistically consistent maximum a posteriori estimates of the tissue reflectivity to be restored. These estimates are proven to provide a reliable source of information for achieving an accurate characterization of biological tissues through the ultrasound echo. The second topic involves the definition of a semi automatic algorithm for myocardium segmentation in 2D echocardiographic images. The results show that the proposed method can reduce inter- and intra observer variability in myocardial contours delineation and is feasible and accurate even on clinical data.
Resumo:
La chirurgia con ultrasuoni focalizzati guidati da MRI (MR-g-FUS) è un trattamento di minima invasività, guidato dal più sofisticato strumento di imaging a disposizione, che utilizza a scopo diagnostico e terapeutico forme di energia non ionizzante. Le sue caratteristiche portano a pensare un suo possibile e promettente utilizzo in numerose aree della patologia umana, in particolare scheletrica. L'osteoma osteoide affligge frequentemente pazienti di giovane età, è una patologia benigna, con origine ed evoluzione non chiare, e trova nella termoablazione con radiofrequenza continua sotto guida CT (CT-g-RFA) il suo trattamento di elezione. Questo lavoro ha valutato l’efficacia, gli effetti e la sicurezza del trattamento dell’osteoma osteoide con MR-g-FUS. Sono stati presi in considerazione pazienti arruolati per MR-g-FUS e, come gruppo di controllo, pazienti sottoposti a CT-g-RFA, che hanno raggiunto un follow-up minimo di 18 mesi (rispettivamente 6 e 24 pazienti). Due pazienti erano stati esclusi dal trattamento MR-g-FUS per claustrofobia (2/8). Tutti i trattamenti sono stati portati a termine con successo tecnico e clinico. Non sono state registrate complicanze o eventi avversi correlati all’anestesia o alle procedure di trattamento, e tutti i pazienti sono stati dimessi regolarmente dopo 12-24 ore. La durata media dei trattamenti di MR-g-FUS è stata di 40±21 min. Da valori di score VAS pre-trattamento oscillanti tra 6 e 10 (su scala 0-10), i trattamenti hanno condotto tutti i pazienti a VAS 0 (senza integrazioni farmacologiche). Nessun paziente ha manifestato segni di persistenza di malattia o di recidiva al follow-up. Nonostante la neurolisi e la risoluzione dei sintomi, la perfusione del nidus è stata ritrovata ancora presente in oltre il 70% dei casi sottoposti a MR-g-FUS (4/6 pazienti). I risultati derivati da un'analisi estesa a pazienti più recentemente arruolati confermano questi dati. Il trattamento con MR-g-FUS sembra essere efficace e sicuro nel risolvere la sintomatologia dell'osteoma osteoide.
Resumo:
Ultrasound imaging is widely used in medical diagnostics as it is the fastest, least invasive, and least expensive imaging modality. However, ultrasound images are intrinsically difficult to be interpreted. In this scenario, Computer Aided Detection (CAD) systems can be used to support physicians during diagnosis providing them a second opinion. This thesis discusses efficient ultrasound processing techniques for computer aided medical diagnostics, focusing on two major topics: (i) Ultrasound Tissue Characterization (UTC), aimed at characterizing and differentiating between healthy and diseased tissue; (ii) Ultrasound Image Segmentation (UIS), aimed at detecting the boundaries of anatomical structures to automatically measure organ dimensions and compute clinically relevant functional indices. Research on UTC produced a CAD tool for Prostate Cancer detection to improve the biopsy protocol. In particular, this thesis contributes with: (i) the development of a robust classification system; (ii) the exploitation of parallel computing on GPU for real-time performance; (iii) the introduction of both an innovative Semi-Supervised Learning algorithm and a novel supervised/semi-supervised learning scheme for CAD system training that improve system performance reducing data collection effort and avoiding collected data wasting. The tool provides physicians a risk map highlighting suspect tissue areas, allowing them to perform a lesion-directed biopsy. Clinical validation demonstrated the system validity as a diagnostic support tool and its effectiveness at reducing the number of biopsy cores requested for an accurate diagnosis. For UIS the research developed a heart disease diagnostic tool based on Real-Time 3D Echocardiography. Thesis contributions to this application are: (i) the development of an automated GPU based level-set segmentation framework for 3D images; (ii) the application of this framework to the myocardium segmentation. Experimental results showed the high efficiency and flexibility of the proposed framework. Its effectiveness as a tool for quantitative analysis of 3D cardiac morphology and function was demonstrated through clinical validation.
Resumo:
The use of guided ultrasonic waves (GUW) has increased considerably in the fields of non-destructive (NDE) testing and structural health monitoring (SHM) due to their ability to perform long range inspections, to probe hidden areas as well as to provide a complete monitoring of the entire waveguide. Guided waves can be fully exploited only once their dispersive properties are known for the given waveguide. In this context, well stated analytical and numerical methods are represented by the Matrix family methods and the Semi Analytical Finite Element (SAFE) methods. However, while the former are limited to simple geometries of finite or infinite extent, the latter can model arbitrary cross-section waveguides of finite domain only. This thesis is aimed at developing three different numerical methods for modelling wave propagation in complex translational invariant systems. First, a classical SAFE formulation for viscoelastic waveguides is extended to account for a three dimensional translational invariant static prestress state. The effect of prestress, residual stress and applied loads on the dispersion properties of the guided waves is shown. Next, a two-and-a-half Boundary Element Method (2.5D BEM) for the dispersion analysis of damped guided waves in waveguides and cavities of arbitrary cross-section is proposed. The attenuation dispersive spectrum due to material damping and geometrical spreading of cavities with arbitrary shape is shown for the first time. Finally, a coupled SAFE-2.5D BEM framework is developed to study the dispersion characteristics of waves in viscoelastic waveguides of arbitrary geometry embedded in infinite solid or liquid media. Dispersion of leaky and non-leaky guided waves in terms of speed and attenuation, as well as the radiated wavefields, can be computed. The results obtained in this thesis can be helpful for the design of both actuation and sensing systems in practical application, as well as to tune experimental setup.