971 resultados para Trussed beams


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the influence of both characteristics of the lens and misalignment of the incident beams on roughness measurement is presented. To investigate how the focal length and diameter affect the degree of correlation between the speckle patterns, a set of experiments with different lenses is performed. On the other hand, the roughness when the beams separated by an amount are non-coincident at the same point on the sample is measured. To conclude the study, the uncertainty of the method is calculated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methods for predicting the shear capacity of FRP shear strengthened RC beams assume the traditional approach of superimposing the contribution of the FRP reinforcing to the contributions from the reinforcing steel and the concrete. These methods become the basis for most guides for the design of externally bonded FRP systems for strengthening concrete structures. The variations among them come from the way they account for the effect of basic shear design parameters on shear capacity. This paper presents a simple method for defining improved equations to calculate the shear capacity of reinforced concrete beams externally shear strengthened with FRP. For the first time, the equations are obtained in a multiobjective optimization framework solved by using genetic algorithms, resulting from considering simultaneously the experimental results of beams with and without FRP external reinforcement. The performance of the new proposed equations is compared to the predictions with some of the current shear design guidelines for strengthening concrete structures using FRPs. The proposed procedure is also reformulated as a constrained optimization problem to provide more conservative shear predictions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of a conductive bare tape electrically floating in low Earth orbit as an effective electron beam source to produce artificial auroral effects, free of problems that mard tandard beams, is considered. Ambient ions impacting the tape with keV energies over most of its length liberate secondary electrons that race down the magnetic field, excite neutrals in the E layer, and result in auroral emissions. The tether would operate with both a power supply and a plasma contactor off at nighttime; power and contactor would be on at daytime for reboost. Tomographic analysis of auroral emissions from the footprint of the beam, as observed from the spacecraft, can provide density profiles of dominant neutral species in the E layer. A characteristic tether system, at altitude 300 km and moderate orbital inclination, would involve an aluminum tape with a length of 20 km, a width of 15 mm, and a thickness of 0.2 mm for a full-system mass around 1200 kg, with two thirds going into the power subsystem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo trata de elementos reforzados con barras de armadura y Fibras Metálicas Recicladas (FMR). El objetivo principal es mejorar el comportamiento a fisuración de elementos sometidos a flexión pura y a flexión compuesta, aumentando en consecuencia las prestaciones en servicio de aquellas estructuras con requerimientos estrictos con respecto al control de fisuración. Entre éstas últimas se encuentran las estructuras integrales, es decir aquellas estructuras sin juntas (puentes o edificios), sometidas a cargas gravitatorias y deformaciones impuestas en los elementos horizontales debidas a retracción, fluencia y temperatura. Las FMR son obtenidas a partir de los neumáticos fuera de uso, y puesto que el procedimiento de reciclado se centra en el caucho en vez que en el acero, su forma es aleatoria y con longitud variable. A pesar de que la eficacia del fibrorefuerzo mediante FMR ha sido demostrada en investigaciones anteriores, la innovación que representa este trabajo consiste en proponer la acción combinada de barras convencionales y FMR en la mejora del comportamiento a fisuración. El objetivo es por tanto mejorar la sostenibilidad del proyecto de la estructura en HA al utilizar materiales reciclados por un lado, y aumentando por el otro la durabilidad. En primer lugar, se presenta el estado del arte con respecto a la fisuración en elementos de HA, que sucesivamente se amplía a elementos reforzados con barras y fibras. Asimismo, se resume el método simplificado para el análisis de columnas de estructuras sin juntas ya propuesto por Pérez et al., con particular énfasis en aquellos aspectos que son incompatibles con la acción de las fibras a nivel seccional. A continuación, se presenta un modelo para describir la deformabilidad seccional y la fisuración en elementos en HA, que luego se amplía a aquellos elementos reforzados con barras y fibras, teniendo en cuenta también los efectos debidos a la retracción (tension stiffening negativo). El modelo es luego empleado para ampliar el método simplificado para el análisis de columnas. La aportación consiste por tanto en contar con una metodología amplia de análisis para este tipo de elementos. Seguidamente, se presenta la campaña experimental preliminar que ha involucrado vigas a escala reducida sometidas a flexión simple, con el objetivo de validar la eficiencia y la usabilidad en el hormigón de las FMR de dos diferentes tipos, y su comportamiento con respecto a fibras de acero comerciales. Se describe a continuación la campaña principal, consistente en ensayos sobre ocho vigas en flexión simple a escala 1:1 (variando contenido en FRM, Ø/s,eff y recubrimiento) y doce columnas a flexión compuesta (variando contenido en FMR, Ø/s,eff y nivel de fuerza axil). Los resultados obtenidos en la campaña principal son presentados y comentados, resaltando las mejoras obtenidas en el comportamiento a fisuración de las vigas y columnas, y la rigidez estructural de las columnas. Estos resultados se comparan con las predicciones del modelo propuesto. Los principales parámetros estudiados para describir la fisuración y el comportamiento seccional de las vigas son: la separación entre fisuras, el alargamiento medio de las armaduras y la abertura de fisura, mientras que en los ensayos de las columnas se ha contrastado las leyes momento/curvatura, la tensión en las barras de armadura y la abertura de fisura en el empotramiento en la base. La comparación muestra un buen acuerdo entre las predicciones y los resultados experimentales. Asimismo, se nota la mejora en el comportamiento a fisuración debido a la incorporación de FMR en aquellos elementos con cuantías de armadura bajas en flexión simple, en elementos con axiles bajos y para el control de la fisuración en elementos con grandes recubrimientos, siendo por tanto resultados de inmediato impacto en la práctica ingenieril (diseño de losas, tanques, estructuras integrales, etc.). VIIIComo punto final, se presentan aplicaciones de las FMR en estructuras reales. Se discuten dos casos de elementos sometidos a flexión pura, en particular una viga simplemente apoyada y un tanque para el tratamiento de agua. En ambos casos la adicción de FMR al hormigón lleva a mejoras en el comportamiento a fisuración. Luego, utilizando el método simplificado para el análisis en servicio de columnas de estructuras sin juntas, se calcula la máxima longitud admisible en casos típicos de puentes y edificación. En particular, se demuestra que las limitaciones de la práctica ingenieril actual (sobre todo en edificación) pueden ser aumentadas considerando el comportamiento real de las columnas en HA. Finalmente, los mismos casos son modificados para considerar el uso de MFR, y se presentan las mejoras tanto en la máxima longitud admisible como en la abertura de fisura para una longitud y deformación impuesta. This work deals with elements reinforced with both rebars and Recycled Steel Fibres (RSFs). Its main objective is to improve cracking behaviour of elements subjected to pure bending and bending and axial force, resulting in better serviceability conditions for these structures demanding keen crack width control. Among these structures a particularly interesting type are the so-called integral structures, i.e. long jointless structures (bridges and buildings) subjected to gravitational loads and imposed deformations due to shrinkage, creep and temperature. RSFs are obtained from End of Life Tyres, and due to the recycling process that is focused on the rubber rather than on the steel they come out crooked and with variable length. Although the effectiveness of RSFs had already been proven by previous research, the innovation of this work consists in the proposing the combined action of conventional rebars and RSFs to improve cracking behaviour. Therefore, the objective is to improve the sustainability of RC structures by, on the one hand, using recycled materials, and on the other improving their durability. A state of the art on cracking in RC elements is firstly drawn. It is then expanded to elements reinforced with both rebars and fibres (R/FRC elements). Finally, the simplified method for analysis of columns of long jointless structures already proposed by Pérez et al. is resumed, with a special focus on the points that conflict when taking into account the action of fibres. Afterwards, a model to describe sectional deformability and cracking of R/FRC elements is presented, taking also into account the effect of shrinkage (negative tension stiffening). The model is then used to implement the simplified method for columns. The novelty represented by this is that a comprehensive methodology to analyse this type of elements is presented. A preliminary experimental campaign consisting in small beams subjected to pure bending is described, with the objective of validating the effectiveness and usability in concrete of RSFs of two different types, and their behaviour when compared with commercial steel fibres. With the results and lessons learnt from this campaign in mind, the main experimental campaign is then described, consisting in cracking tests of eight unscaled beams in pure bending (varying RSF content, Ø/s,eff and concrete cover) and twelve columns subjected to imposed displacement and axial force (varying RSF content, Ø/s,eff and squashing load ratio). The results obtained from the main campaign are presented and discussed, with particular focus on the improvement in cracking behaviour for the beams and columns, and structural stiffness for the columns. They are then compared with the proposed model. The main parameters studied to describe cracking and sectional behaviours of the beam tests are crack spacing, mean steel strain and crack width, while for the column tests these were moment/curvature, stress in rebars and crack with at column embedment. The comparison showed satisfactory agreement between experimental results and model predictions. Moreover, it is pointed out the improvement in cracking behaviour due to the addition of RSF for elements with low reinforcement ratios, elements with low squashing load ratios and for crack width control of elements with large concrete covers, thus representing results with a immediate impact in engineering practice (slab design, tanks, integral structures, etc.). Applications of RSF to actual structures are finally presented. Two cases of elements in pure bending are presented, namely a simple supported beam and a water treatment tank. In both cases the addition of RSF to concrete leads to improvements in cracking behaviour. Then, using the simplified model for the serviceability analysis of columns of jointless structures, the maximum achievable jointless length of typical cases of a bridge and building is obtained. In XIIparticular, it is shown how the limitations of current engineering practice (this is especially the case of buildings) can be increased by considering the actual behaviour of RC supports. Then, the same cases are modified considering the use of RSF, and the improvements both in maximum achievable length and in crack width for a given length and imposed strain at the deck/first floor are shown.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electrically floating bare tether in LEO orbit may serve as upper atmospheric probe. Ambient ions bombard the negatively biased tether and liberate secondary electrons, which accelerate through the same voltage to form a magnetically guided planar e-beam resulting in auroral effects at the E-layer. This beam is free from the S/C charging and plasma interaction problems of standard e-beams. The energy flux is weak but varies accross the large beam cross section, allowing continuous observation from the S/C. A brightness scan of line-integrated emissions, that mix emitting altitudes and tether points originating the electrons, is analysed. The tether is magnetically dragged at nighttime operation, when power supply and plasma contactor at the S/C are off for electrical floating; power and contactor are on at daytime for partial current reversal, resulting in thrust. System requirements for keeping average orbital height are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ESS-Bilbao facility, hosted by the University of the Basque Country (UPV/EHU), envisages the operation of a high-current proton accelerator delivering beams with energies up to 50 MeV. The time-averaged proton current will be 2.25 mA, delivered by 1.5 ms proton pulses with a repetition rate of 20 Hz. This beam will feed a neutron source based upon the Be (p,n) reaction, which will enable the provision of relevant neutron experimentation capabilities. The neutron source baseline concept consists in a rotating beryllium target cooled by water. The target structure will comprise a rotatable disk made of 6061-T6 aluminium alloy holding 20 beryllium plates. Heat dissipation from the target relies upon a distribution of coolant-flow channels. The practical implementation of such a concept is here described with emphasis put on the beryllium plates thermo-mechanical optimization, the chosen coolant distribution system as well as the mechanical behavior of the assembly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The European Spallation Source-Bilbao (ESS-Bilbao) project plans to build an accelerator facility compliant with the ESS-AB requirements which will be able to drive several experimental stations for research purposes involving intense proton beams with currents up to 75 mA, 50 MeV of final energy, 1.5 ms of pulse length and up to 50 Hz repetition rate. The accelerator will also drive a compact neutron source which will provide useful neutron beams to carry out experiments on moderator optimization, neutron optics devices and general neutron instrumentation as well as preparation work for experiments to be carried out by neutron beam users at the large facilities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High Intensity Lasers Application to Advanced Materials Processing: Laser Peening and Related

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ion beam therapy is a valuable method for the treatment of deep-seated and radio-resistant tumors thanks to the favorable depth-dose distribution characterized by the Bragg peak. Hadrontherapy facilities take advantage of the specific ion range, resulting in a highly conformal dose in the target volume, while the dose in critical organs is reduced as compared to photon therapy. The necessity to monitor the delivery precision, i.e. the ion range, is unquestionable, thus different approaches have been investigated, such as the detection of prompt photons or annihilation photons of positron emitter nuclei created during the therapeutic treatment. Based on the measurement of the induced β+ activity, our group has developed various in-beam PET prototypes: the one under test is composed by two planar detector heads, each one consisting of four modules with a total active area of 10 × 10 cm2. A single detector module is made of a LYSO crystal matrix coupled to a position sensitive photomultiplier and is read-out by dedicated frontend electronics. A preliminary data taking was performed at the Italian National Centre for Oncological Hadron Therapy (CNAO, Pavia), using proton beams in the energy range of 93–112 MeV impinging on a plastic phantom. The measured activity profiles are presented and compared with the simulated ones based on the Monte Carlo FLUKA package.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One presents in this work the study of the interaction between a focused laser beam and Si nanowires (NWs). The NWs heating induced by the laser beam is studied by solving the heat transfer equation by finite element methods (FEM). This analysis permits to establish the temperature distribution inside the NW when it is excited by the laser beam. The overheating is dependent on the dimensions of the NW, both the diameter and the length. When performing optical characterisation of NWs using focused laser beams, one has to consider the temperature increase introduced by the laser beam. An important issue concerns the fact that the NW's diameter has subwavelength dimensions, and is also smaller than the focused laser beam. The analysis of the thermal behaviour of the NWs under the excitation with the laser beam permits the interpretation of the Raman spectrum of Si NWs. It is demonstrated that the temperature increase induced by the laser beam plays a major role in shaping the Raman spectrum of Si NWs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of a (bare) conductive tape electrically floating in LEO as an effective e-beam source that produces artificial auroras, and is free of problems that have marred standard beams, is considered. Ambient ions impacting the tape with KeV energies over most of its length liberate secondary electrons, which race down the magnetic field and excite neutrals in the E-layer, resulting in auroral emissions. The tether would operate at night-time with both a power supply and a plasma contactor off; power and contactor would be on at daytime for reboost. The optimal tape thickness yielding a minimum mass for an autonomous system is determined; the alternative use of an electric thruster for day reboost, depending on mission duration, is discussed. Measurements of emission brightness from the spacecraft could allow determination of the (neutral) density vertical profile in the critical E-layer; the flux and energy in the beam, varying along the tether, allow imaging line-of-sight integrated emissions that mix effects with altitude-dependent neutral density and lead to a brightness peak in the beam footprint at the E-layer. Difficulties in tomographic inversion, to determine the density profile, result from beam broadening, due to elastic collisions, which flattens the peak, and to the highly nonlinear functional dependency of line-of-sight brightness. Some dynamical issues are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las estructuras de hormigón son susceptibles de sufrir los efectos asociados a las acciones de fatiga cuando estas se ven sometidas a un elevado número de cargas repetidas. Muchas de estas estructuras no requieren armadura transversal para cumplir los condicionantes de dimensionamiento estático como por ejemplo las losas superiores de tableros de puentes, los muros de contención, las losas de transición de puentes, las torres eólicas o las estructuras marítimas. La mayor parte de los códigos de diseño vigentes no incluyen una comprobación específica del nivel de seguridad a cortante de estas estructuras para acciones de fatiga, y aquellas que lo hacen prefieren utilizar expresiones de tipo empírico basadas en curvas S-N que relacionan el número de ciclos resistentes con el valor de la carga aplicada. A pesar de que el empleo de curvas S-N es de gran utilidad desde un punto de vista práctico, estas curvas no permiten comprender el proceso de rotura por cortante para cargas repetidas. El objetivo principal de esta Tesis es el de estudiar el comportamiento a cortante de elementos de hormigón armado sin cercos sometidos a fatiga. Además, el análisis es ampliado al estudio del comportamiento transversal de los voladizos de las losas superiores de tableros de puentes de hormigón que de forma habitual son diseñados sin armadura de cortante. De forma habitual estos elementos se diseñan atendiendo a criterios de dimensionamiento estáticos sin tener en cuenta la resistencia a cortante cuando se ven sometidos a cargas cíclicas. A pesar de que las cargas de fatiga son inferiores a aquellas que producen el fallo estático, es importante tener en cuenta el comportamiento de estos elementos ante cargas repetidas. Los trabajos experimentales existentes en vigas de hormigón armado sin cercos evidenciaron diferencias significativas entre los modos de fallo ante cargas estáticas y cíclicas. Estos trabajos llegaron a la conclusión de que estos elementos diseñados para tener un fallo dúctil por flexión pueden llegar a desarrollar un tipo de fallo frágil por cortante cuando se ven sometidos a cargas repetidas. El proceso de rotura por cortante en elementos de hormigón armado sin cercos sometidos a fatiga es un proceso complejo que debe ser estudiado en profundidad debido al carácter frágil de este tipo de fallo. Los trabajos experimentales permitieron comprobar que el origen de este fallo tiene lugar tras la formación de una fisura de cortante a partir de una fisura de flexión formada durante los primeros ciclos en el vano de cortante. Tras la formación de esta fisura, esta se va propagando hacia la cabeza de compresión hasta que finalmente se produce el fallo como consecuencia de la destrucción de la cabeza de compresión cuando la altura alcanzada por esta es insuficiente para resistir la fuerza de compresión aplicada en esta zona. Por otra parte, la propagación de esta fisura diagonal puede desarrollarse por completo en el instante en el que esta se forma derivando en un tipo de fallo por cortante más frágil que el anterior. El proceso de fatiga es estudiado en esta Tesis mediante un modelo mecánico. Por una parte, se propone un modelo predictivo para determinar el número de ciclos acumulados hasta que se forma la fisura diagonal en función del estado tensional que se tiene en la punta de una fisura crítica de flexión formada en los primeros ciclos. Por otra parte, la resistencia a fatiga tras la formación de la fisura diagonal se analiza teniendo en cuenta el daño por fatiga acumulado en la cabeza de compresión y las variables que afectan a la propagación de esta fisura de cortante. Para la evaluación de la resistencia a fatiga tras la formación de la fisura crítica de cortante en este tipo de elementos, se plantea un modelo teórico basado en conceptos de Mecánica de la Fractura adaptados al hormigón. Este modelo puede ser aplicado a vigas de hormigón armado sin cercos de canto constante o variable siguiendo diferentes procedimientos. Una campaña experimental ha sido llevada a cabo con el objetivo de estudiar el comportamiento a cortante de vigas de hormigón armado sin cercos de canto variable sometidas a cargas estáticas y de fatiga. Se han desarrollado un total de diez ensayos estáticos y de fatiga para diferentes niveles de carga y esbelteces de cortante, teniendo lugar diferentes modos de fallo. Estos elementos fueron diseñados para reproducir, a escala real y de forma simplificada, los voladizos laterales de las losas superiores de tableros de puentes de carretera de hormigón. Los resultados experimentales demostraron que el tipo de fallo desarrollado depende de varios parámetros como por ejemplo el nivel de carga máxima, el nivel de oscilación de tensiones en la armadura longitudinal, la esbeltez de cortante o la calidad del hormigón utilizado entre otros. Para valores similares de esbeltez de cortante, los ensayos de fatiga realizados permitieron comprobar que la rotura por cortante de estos elementos está asociada a niveles de carga máxima elevados, mientras que el fallo por fatiga de la armadura longitudinal tiene mayor probabilidad de ocurrir en elementos sometidos a elevados niveles de oscilación de tensiones en esta armadura. Además, estos ensayos han sido analizados a través del modelo propuesto para tratar de comprender el comportamiento resistente de estos elementos sometidos a cargas de fatiga. Concrete structures are able to suffer fatigue when they are subjected to high number of cyclic loads. Many of these need not shear reinforcement to satisfy static design requirements, such as bridge deck slabs, retaining walls, bridge approach slabs, wind towers or maritime structures among others. Many codes of practice do not include a verification of the shear fatigue safety. Moreover, those which include it still prefer empirical S-N-based approaches that provide the number of cycles as a function of applied forces. S-N models are practical but they do not provide information to understand the shear fatigue process. The main objective of this Thesis is to study shear behaviour of reinforced concrete elements without stirrups subjected to fatigue loads. In addition, the analysis is extended in order to study the transverse behaviour of cantilever slabs of concrete bridges that traditionally are designed without shear reinforcement. These elements usually are designed on the basis of static strength and it is unusual that codes consider fatigue strength of concrete in shear. Accordingly, it is important to take into account the fatigue behaviour of structural members subjected to cyclic loads although these loads are lower than those which produce the static failure. Existing experimental works show important differences between the static and cyclic failure modes of reinforced concrete beams without stirrups. These works concluded that beams without transverse reinforcement, designed to have a ductile failure mode in flexure, can submit a brittle shear failure mode when they are subjected to repeated loads. Shear fatigue failure of reinforced concrete beams without stirrups is a rather complex process from the mechanical viewpoint. Since it leads to a brittle failure mode it should be better understood. Experimental evidence indicates that a diagonal crack first develops from the inclination of flexural cracks in the shear span. Thereafter, the diagonal crack propagates into the compression zone. Failure normally takes place by the destruction of the compression zone when its depth is too small to resist the applied force. The propagation of the diagonal crack can also be instantaneous, leading to sudden diagonal cracking fatigue failure rather than shear-compression failure. Fatigue process is studied in this Thesis on a mechanical basis. On the one hand, a predictive model is derived to obtain the number of cycles up to diagonal cracking, as a function of the stress state at the tip of a critical flexural crack. On the other hand, the residual fatigue strength after diagonal cracking is analyzed taking into account the fatigue damage accumulated by the compression zone and the variables affecting the propagation of the diagonal crack. In order to assess the residual fatigue strength after diagonal cracking of such elements, a theoretical model is proposed based on concepts from fracture mechanics adapted to concrete. This model can be successfully applied for straight or haunched reinforced concrete beams without stirrups following different procedures. In order to achieve a more advanced knowledge in this subject, an experimental campaign has been carried out with the aim of study the shear behaviour of reinforced concrete haunched beams without stirrups subjected to static and fatigue loads. A total of ten static and fatigue tests have been performed with distinct load levels and shear span-to-depth ratios, presenting different failures modes. These elements were designed to reproduce in a simplified form the cantilever slab of concrete bridges at real scale. Experimental results showed that the type of failure depends on several parameters as for example the maximum load level, the stress oscillation level on the longitudinal reinforcement, the shear span-to-depth ratio or the quality of the concrete used among others. For a similar value of the shear span-to-depth ratio, tests evidenced that shear fatigue failure is related to high maximum load levels, while steel fatigue failure is easier to occur in elements subjected to high stress oscillation level on the reinforcement bars. Besides, these tests have been analyzed through the proposed model in order to clarify the structural behaviour of such elements subjected to fatigue loads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Space applications of electrodynamic tethers, and basic issues and constraints on their operation are reviewed. The status of the bare-tether solution to the problem of effective electron collection from a rarefied magnetized plasma is revisited. Basic modes of tether operation are analyzed; design parameters and parametric domains where a bare electrodynamic tether is most efficient in deorbiting, rebooking, or power generation, are determined. Use of bare tethers for Radiation Belt Remediation and generation of electron beams for ionospheric research is considered. Teiher heating, arcing, and bowing or breaking, as well deployment strategies are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bare electrodynamic tether (EDT) is a conductive thin wire or tape tens of kilometres long, which is kept taut in space by gravity gradient or spinning, and is left bare of insulation to collect (and carry) current as a cylindrical Langmuir probe in an ambient magnetized plasma. An EDT is a probe in mesothermal flow at highly positive (or negative) bias, with a large or extremely large 2D sheath, which may show effects from the magnetic self-field of its current and have electrons adiabatically trapped in its ram front. Beyond technical applications ranging from propellantless propulsion to power generation in orbit, EDTs allow broad scientific uses such as generating electron beams and artificial auroras; exciting Alfven waves and whistlers; odifying the radiation belts; and exploring interplanetary space and the Jovian magnetosphere. Asymptotic analysis, numerical simulations, laboratory tests, and planned missions on EDTs are reviewed