977 resultados para Transcatheter aortic valve replacement
Resumo:
Power transformer is the most expensive equipment on a substation. It is always necessary to get needed benefit with the lowest expenses. Producing of power transformers with reduced insulation strength is one of the possible ways to reduce expenses. Exploitation of such transformers was begun in the end of 70-th in the last century. Protection from overvoltages was done with valve-type magnetic combined surge arresters with increased blanking voltage during switching overvoltages. Nowadays there is the necessity of replacement of those devices. That’s why modernized nonlinear surge arrester was invented. This master’s thesis is focused on the use research of that modernized device in comparison with usual nonlinear surge arresters. The goal is to show the lightning overvoltages level using different types of nonlinear surge arresters and then calculations of the lightning protection reliability.
Resumo:
The treatment of abdominal aortic aneurysm (AAA) has shifted from the exposure of the aorta artery in an open repair technique to a small groin cut in an endovascular repair. Recently, a percutaneous access for endovascular repair has appeared. This new technique aims to minimize the complications of the common femoral artery exposure, the patient discomfort and the length of hospitalizationObjectives: To compare the proportion of discharged patients within the first 48 postoperative hours of two common femoral artery accesses for endovascular repair of AAA: the open exposure technique and the percutaneous technique. Secondary objectives include to evaluate the total procedure time, the femoral access complications, the need for extra analgesia and the patient satisfaction and groin discomfort of the two techniquesDesign: Randomized controlled trial conducted between 2014 and 2017Participants: Patients diagnosed with abdominal aortic aneurysm with elective endovascular repair indication
Resumo:
The objective of the work is to study fluid flow behavior through a pinch valve and to estimate the flow coefficient (KV ) at different opening positions of the valve. The flow inside a compressed valve is more complex than in a straight pipe, and it is one of main topics of interest for engineers in process industry. In the present work, we have numerically simulated compressed valve flow at different opening positions. In order to simulate the flow through pinch valve, several models of the elastomeric valve tube (pinch valve tube) at different opening positions were constructed in 2D-axisymmetric and 3D geometries. The numerical simulations were performed with the CFD packages; ANSYS FLUENT and ANSYS CFX by using parallel computing. The distributions of static pressure, velocity and turbulent kinetic energy have been studied at different opening positions of the valve in both 2D-axisymmetric and 3D experiments. The flow coefficient (KV ) values have been measured at different valve openings and are compared between 2D-axisymmetric and 3D simulation results.
Resumo:
BACKGROUND: Liver vascular isolation is essential for the treatment of the retrohepatic vena cava and hepatic veins. Triple vessel occlusion (TVO - occlusion of the portal triad, the inferior vena cava above the renal veins and within the pericardium) is the easiest isolation method for the surgeon. Unfortunately, this technique cannot be applied to hypovolemic and/or shock (cardiac arrest) patients as it compromises venous return. OBJECTIVES: Our objective is to demonstrate that in the above mentioned patients, establishing a previous hypervolemic state allows the safe use of TVO. METHODS: The method includes efficient injury tamponade with aggressive fluid replacement until normal blood volume is reached (resuscitation). Normal blood volume is recognized by a return of arterial blood pressure to normal levels, inferior vena cava filling and an increase in aortic wall tension. Following this procedure, hypervolemia is obtained by the rapid additional infusion of 1.500 to 2.000 ml of fluids. TVO in this situation does not alter the heart rhythm and maintains a clear operative field which is essential for hepatotomy, venorrhaphy and or venous ligation. RESULTS: Three patients were successfully operated.
Resumo:
Degenerative myxomatous mitral valve (DMMV) is a heart disease of high incidence in small animal clinical medicine, affecting mainly older dogs and small breeds. Thus, a scientific investigation was performed in order to evaluate the clinical use of the medicines furosemide and enalapril maleate in dogs with this disease in CHF functional class Ib before and after the treatment was established. For this purpose 16 dogs with the given valve disease were used, separated into two groups: the first received furosemide (n=8) and the second received enalapril maleate (n=8) throughout 56 days. The dogs were evaluated in four stages (T0, T14, T28 and T56 day) in relation to clinical signs, hematological, biochemical and serum assessment, which included serum angiotensin converting enzyme (ACE) and aldosterone, as well as radiography, electrocardiography, Doppler-echocardiography and blood pressure. The results regarding the clinical, hematological and serum chemistry evaluations revealed no significant changes in both groups, but significant reductions in the values of ACE and aldosterone in the group receiving enalapril maleate were verified. The radiographic examination revealed reductions of VHS values and variable Pms wave of the electrocardiogram in both groups, but no changes in blood pressure values were identified. The echocardiogram showed a significant decrease of the variables LVDd/s in the studied groups and the FS% in animals that received only enalapril. Therefore, analysis of results showed that monotherapy based on enalapril maleate showed better efficiency of symptoms control in patients with CHF functional class Ib.
Resumo:
Luettelo Kansalliskirjastossa olevan Kaarlo Väinö Valveen arkiston sisällöstä
Resumo:
Due to the increase of water deficiency in many farm regions and its meaning on weed interference, competitive interactions between soybean and three weeds were evaluated under water stress (20 to 40 days after transplanting) and no stress conditions. Three independent experiments were carried out in a growth chamber, being each one composed by the weeds Alternanthera tenella, Tridax procumbens or Digitaria ciliaris, along with the crop, in which soil water condition and plant composition effects were evaluated while in competition. A replacement series system was used, including both monoculture of each species and a mixture with a ratio of 50% between weed and soybean. A completely randomized design was used in factorial arrangement, with treatments distributed in three levels for plant composition factor (soybean and weeds monocultures, in addition to the soybean + weed mixture) and two levels for the water factor (with or without stress), amounting six treatments in each experiment. Soybean dry mass was higher than weed dry mass, when growing without water stress. However, under water stress conditions, the dry mass of soy was reduced in all experiments, mainly in the D. ciliaris comparative experiment. Water restriction was also significant in the plants' photosynthesis reduction in most of the experiments, reducing leaf area duration and efficiency of water use. Analysing all variables shows greater weed tolerance than soybean when submitted to water deficit and with distinct changes of their interactions and mechanism of competition, in each experiment.
Resumo:
Large-headed total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) with metal-on-metal (MoM) bearings became popular during the last decade. Recently, it has become evident that the large-head MoM hip implants are associated with increased revision rates despite their theoretical advantages. The purpose of this study was to evaluate the early results of primary MoM hip replacements and of acetabular revisions. I analyzed retrospectively the results of four MoM implant designs and the survival rate of acetabular revisions with impaction bone grafting, as documented in the Turku University Hospital database. Further, I evaluated the correlation between femoral head size and dislocation rate, and used the Finnish Arthroplasty Register data to compare the survival of three large-head MoM THAs to analogous HRAs. The early results for the Magnum M2A–ReCap THA were good. A larger head size decreased the risk of dislocation. Articular surface replacement (ASR) THA yielded inferior results compared to analogous HRA. For two other designs the results were similar. The R3–Synergy THA yielded inferior results compared to the reference implants. The survival of acetabular reconstructions with impaction bone grafting was inferior compared to previous reports. In conclusion, the early results of the Biomet ReCap–Magnum design were promising, and large head sizes decreased the dislocation rate. The survival of different MoM hip implant designs varied. The survival of new designs and techniques may be inferior to those reported by the clinics where implants are developed. An important caveat is that early promising results of new devices may rapidly worsen. New implants need to be introduced in a controlled fashion to the market; here, arthroplasty registers are a valuable tool that needs to be used.
Resumo:
Angiotensin II (ANG II) and vasopressin (AVP) act together with the mechanical effect of aortic constriction in the onset of acute aortic coarctation hypertension. Blockade of ANG II and AVP V1 receptors demonstrated that ANG II acts on the prompt (5 min) rise in pressure whereas AVP is responsible for the maintenance (30-45 min) of the arterial pressure elevation during aortic coarctation. Hormone assays carried out on blood collected from conscious rats submitted to aortic constriction supported a role for ANG II in the early stage and a combined role for both ANG II and AVP in the maintenance of proximal hypertension. As expected, a role for catecholamines was ruled out in this model of hypertension, presumably due to the inhibitory effect of the sinoaortic baroreceptors. The lack of afferent feedback from the kidneys for AVP release from the central nervous system in rats with previous renal denervation allowed ANG II to play the major role in the onset of the hypertensive response. Median eminence-lesioned rats exhibited a prompt increase in proximal pressure followed by a progressive decline to lower hypertensive levels, revealing a significant role for the integrity of the neuroaxis in the maintenance of the aortic coarctation hypertension through the release of AVP. In conclusion, the important issue raised by this model of hypertension is the likelihood of a link between some vascular territory - probably renal - below the coarctation triggering the release of AVP, with this vasoconstrictor hormone participating with Ang II and the mechanical effect of aortic constriction in the acute aortic coarctation hypertension
Resumo:
The present study evaluated the short-term effects of percutaneous 17ß-estradiol on blood pressure, metabolic profile and hormonal levels in postmenopausal women with systemic arterial hypertension. After a wash-out period of 15 days, 10 hypertensive patients were treated with guanabenz acetate to control blood pressure, followed by 17ß-estradiol in the form of hydroalcoholic gel administered for 21 of 28 days of each cycle, for 3 cycles. Patients were evaluated before, during and 2 months after estrogen administration. Systolic and diastolic blood pressure or heart rate did not present any significant change in any patient when compared to those periods with the antihypertensive drug only (pretreatment period and 60 days after estrogen therapy was discontinued). Plasma biological markers of hepatic estrogenic action (plasma renin activity, antithrombin III, triglycerides, total cholesterol and lipoproteins) also remained unchanged during the study. Hormone treatment was effective, as indicated by the relief of menopausal symptoms, a decrease in FSH levels (73.48 ± 27.21 to 35.09 ± 20.44 IU/l, P<0.05), and an increase in estradiol levels (15.06 ± 8.76 to 78.7 ± 44.6 pg/ml, P<0.05). There was no effect on LH (18.0 ± 9.5 to 14.05 ± 8.28 IU/l). Hormone levels returned to previous values after estrogen treatment was discontinued. The data indicate that short-term percutaneous 17ß-estradiol replacement therapy, at the dose used, seems to be a safe hormone therapy for hypertensive menopausal women. Nevertheless, a controlled, prospective, randomized clinical assay with a larger number of subjects is needed to definitely establish both the beneficial and harmful effects of hormone replacement therapy in hypertensive women
Resumo:
To determine the possible relationship between left ventricular dilatation and heart rate changes provoked by the Valsalva maneuver (Valsalva ratio), we studied 9 patients with isolated chronic aortic insufficiency. Left ventricular systolic function was assessed by two-dimensional echocardiography and cardiac catheterization. All patients were asymptomatic (functional class I of the New York Heart Association). The left ventricular internal diameters and volumes were significantly increased in all patients. The asymptomatic patients had either normal or slightly depressed ejection fraction (EF>0.40). The Valsalva ratio of these asymptomatic patients showed no significant correlation with the left ventricular volumes or with the left ventricular ejection fraction. In other words, parasympathetic heart rate control, as expressed by the Valsalva ratio, was normal in the asymptomatic patients with left ventricular dilatation and preserved left ventricular ejection fraction. Therefore, left ventricular dilatation may not be the major mechanism responsible for the abnormal parasympathetic heart rate control of patients with acquired heart disease
Resumo:
The hemodynamic responses to acute (45 min) partial aortic constriction were studied in conscious intact (N = 7) or sinoaortic denervated (SAD) adult male Wistar rats (280-350 g, N = 7) implanted with carotid and femoral arterial catheters, a pneumatic cuff around the abdominal aorta and a pulsed Doppler flow probe to measure changes in aortic resistance. In addition, the hypertensive response and the reflex bradycardia elicited by total (N = 8) vs partial (N = 7) aortic constriction (monitored by maintenance of the pressure distal to the cuff at 50 mmHg) were compared in two other groups of intact rats. Intact rats presented a smaller hypertensive response (26 to 40% above basal level) to partial aortic constriction than SAD rats (38 to 58%). The calculated change in aortic resistance imposed by constriction of the aorta increased progressively only in intact rats, but was significantly smaller (193 to 306%) than that observed (501 to 591%) in SAD rats. Intact rats showed a significant bradycardia (23 to 26% change in basal heart rate) throughout coarctation, whereas the SAD rats did not (1 to 3%). Partial or total occlusion of the aorta induced similar hypertensive responses (37-38% vs 24-30% for total constriction) as well as reflex bradycardia (-15 to -17% vs -22 to -33%) despite a greater gradient in pressure (97-98 vs 129-140 mmHg) caused by total constriction. The present data indicate that the integrity of the baroreflex in intact rats can cause the hypertensive response to level off at a lower value than in SAD rats despite a progressive increase in aortic resistance. In addition, they also indicate that the degree of partial aortic constriction by maintenance of the pressure distal to the cuff at 50 mmHg already elicits a maximal stimulation of the arterial baroreflex
Resumo:
A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.