965 resultados para The bilinear method
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.
Resumo:
The following paper introduces a new approach to the analysis of offensive game in football. Therefore, the main aim of this study was to create an instrument for collecting information for the analysis of offensive action and interactions game. The observation instrument that was used to accomplish the main objective of this work consists of a combination of format fields (FC) and systems of categories (SC). This methodology is a particular strategy of the scientific method that has as an objective to analyse the perceptible behaviour that occurs in habitual contexts, allowing them to be formally recorded and quantified and using an ad hoc instrument in order to obtain a behaviour systematic registration that, since they have been transformed in quantitative data with the necessary reliability and validity determined level, will allow analysis of the relations between these behaviours. The codifications undertaken to date in various games of football have shown that it serves the purposes for which it was developed, allowing more research into the offensive game methods in football.
Resumo:
A new method was developed for breaking high strength prestressed cable. The old method used an aluminum oxide grit packed into a special gripping jaw. The new method uses aluminum shims wrapped around the cable and then is gripped with a V-grip. The new method gives nearly 100% "good breaks" on the cable compared to approximately 10% good breaks with the old method. In addition, the new cable breaking method gives higher ultimate tensile strengths, is more reproducible, is quicker, cleaner and easier on equipment.
Resumo:
BACKGROUND AND PURPOSE: To determine whether infarct core or penumbra is the more significant predictor of outcome in acute ischemic stroke, and whether the results are affected by the statistical method used. METHODS: Clinical and imaging data were collected in 165 patients with acute ischemic stroke. We reviewed the noncontrast head computed tomography (CT) to determine the Alberta Score Program Early CT score and assess for hyperdense middle cerebral artery. We reviewed CT-angiogram for site of occlusion and collateral flow score. From perfusion-CT, we calculated the volumes of infarct core and ischemic penumbra. Recanalization status was assessed on early follow-up imaging. Clinical data included age, several time points, National Institutes of Health Stroke Scale at admission, treatment type, and modified Rankin score at 90 days. Two multivariate regression analyses were conducted to determine which variables predicted outcome best. In the first analysis, we did not include recanalization status among the potential predicting variables. In the second, we included recanalization status and its interaction between perfusion-CT variables. RESULTS: Among the 165 study patients, 76 had a good outcome (modified Rankin score ≤2) and 89 had a poor outcome (modified Rankin score >2). In our first analysis, the most important predictors were age (P<0.001) and National Institutes of Health Stroke Scale at admission (P=0.001). The imaging variables were not important predictors of outcome (P>0.05). In the second analysis, when the recanalization status and its interaction with perfusion-CT variables were included, recanalization status and perfusion-CT penumbra volume became the significant predictors (P<0.001). CONCLUSIONS: Imaging prediction of tissue fate, more specifically imaging of the ischemic penumbra, matters only if recanalization can also be predicted.
Resumo:
Purpose: Although several approaches have been already used to reduce radiation dose, CT doses are still among the high doses in radio-diagnostic. Recently, General Electric introduced a new imaging reconstruction technique, adaptive statistical iterative reconstruction (ASIR), allows to taking into account the statistical fluctuation of noise. The benefits of ASIR method were assessed through classic metrics and the evaluations of cardiac structures by radiologists. Methods and materials: A 64-row CT (MDCT) was employed. Catphan600 phantom acquisitions and 10 routine-dose CT examinations performed at 80 kVp were reconstructed with FBP and with 50% of ASIR. Six radiologists then assessed the visibility of main cardiac structures using the visual grading analysis (VGA) method. Results: On phantoms, for a constant value of SD (25 HU), CTDIvol is divided by 2 (8 mGy to 4 mGy) when 50% of ASIR is used. At constant CTDIvol, MTF medium frequencies were also significantly improved. First results indicated that clinical images reconstructed with ASIR had a better overall image quality compared with conventional reconstruction. This means that at constant image quality the radiation dose can be strongly reduced. Conclusion: The first results of this study shown that the ASIR method improves the image quality on phantoms by decreasing noise and improving resolution with respect to the classical one. Moreover, the benefit obtained is higher at lower doses. In clinical environment, a dose reduction can still be expected on 80 kVp low dose pediatric protocols using 50% of iterative reconstruction. Best ASIR percentage as a function of cardiac structures and detailed protocols will be presented for cardiac examinations.
Resumo:
The Troxler 3241-B Asphalt Content Gauge is intended for rapidly determining the bitumen content of bituminous paving mixtures. A 300 Millicurie Americuium 241: Beryllium source emitts neutrons which are affected by the hydrogen in the mix. The affected neutrons are detected by Helium 3 detectors, counted and computed into a percentage bitumen of the asphalt mix. The current methods of determining the bitumen content of bituminous paving mixtures requires the use of potentially hazardous chemicals and several hours of testing time. When extracted aggregates are not needed, determination of the bitumen content of a paving mixture by the nuclear method may be easier, quicker and potentially safer. The objective of the project is to study the accuracy of the Troxler 3241-B Nuclear Asphalt Content Gauge in measuring the asphalt cement (AC) content of asphalt concrete mixtures produced with different asphalt cements and different aggregates.
Resumo:
There has been relatively little change over recent decades in the methods used in research on self-reported delinquency. Face-to-face interviews and selfadministered interviews in the classroom are still the predominant alternatives envisaged. New methods have been brought into the picture by recent computer technology, the Internet, and an increasing availability of computer equipment and Internet access in schools. In the autumn of 2004, a controlled experiment was conducted with 1,203 students in Lausanne (Switzerland), where "paper-and-pencil" questionnaires were compared with computer-assisted interviews through the Internet. The experiment included a test of two different definitions of the (same) reference period. After the introductory question ("Did you ever..."), students were asked how many times they had done it (or experienced it), if ever, "over the last 12 months" or "since the October 2003 vacation". Few significant differences were found between the results obtained by the two methods and for the two definitions of the reference period, in the answers concerning victimisation, self-reported delinquency, drug use, failure to respond (missing data). Students were found to be more motivated to respond through the Internet, take less time for filling out the questionnaire, and were apparently more confident of privacy, while the school principals were less reluctant to allow classes to be interviewed through the Internet. The Internet method also involves considerable cost reductions, which is a critical advantage if self-reported delinquency surveys are to become a routinely applied method of evaluation, particularly so in countries with limited resources. On balance, the Internet may be instrumental in making research on self-reported delinquency far more feasible in situations where limited resources so far have prevented its implementation.
Resumo:
INTRODUCTION: The pathogenic mechanism of orthostatic proteinuria has not yet been clearly established. OBSERVATION: In a tall, thin, 21 year-old man, isolated proteinuria was discovered during an urological control conducted one year after a bilateral orchidopexy following left testicular torsion. Proteinuria was orthostatic. Doppler examination of the kidney revealed an entrapment of the left renal vein (nutcracker phenomenon-NCP). COMMENTS: An NCP was diagnosed in a young patient presenting with orthostatic proteinuria. By provoking modifications in intraglomerular haemodynamics, the NCP may, in nearly half of the cases, be at the origin of orthostatic proteinuria. Doppler examination is the diagnostic method of choice in the screening for NCP.
Resumo:
A new method was developed for breaking high strength prestressed cable. The old method used an aluminum oxide grit packed into a special gripping jaw. The new method uses aluminum shims wrapped around the cable and then is gripped with a V-grip. The new method gives nearly 100% "good breaks" on the cable compared to approximately 10% good breaks with the old method. In addition, the new cable breaking method gives higher ultimate tensile strengths, is more reproducible, is quicker, cleaner and easier on equipment.
Resumo:
BACKGROUND: The activity of the renin-angiotensin system is usually evaluated as plasma renin activity (PRA, ngAI/ml per h) but the reproducibility of this enzymatic assay is notoriously scarce. We compared the inter and intralaboratory reproducibilities of PRA with those of a new automated chemiluminescent assay, which allows the direct quantification of immunoreactive renin [chemiluminescent immunoreactive renin (CLIR), microU/ml]. METHODS: Aliquots from six pool plasmas of patients with very low to very high PRA levels were measured in 12 centres with both the enzymatic and the direct assays. The same methods were applied to three control plasma preparations with known renin content. RESULTS: In pool plasmas, mean PRA values ranged from 0.14 +/- 0.08 to 18.9 +/- 4.1 ngAI/ml per h, whereas those of CLIR ranged from 4.2 +/- 1.7 to 436 +/- 47 microU/ml. In control plasmas, mean values of PRA and of CLIR were always within the expected range. Overall, there was a significant correlation between the two methods (r = 0.73, P < 0.01). Similar correlations were found in plasmas subdivided in those with low, intermediate and high PRA. However, the coefficients of variation among laboratories found for PRA were always higher than those of CLIR, ranging from 59.4 to 17.1% for PRA, and from 41.0 to 10.7% for CLIR (P < 0.01). Also, the mean intralaboratory variability was higher for PRA than for CLIR, being respectively, 8.5 and 4.5% (P < 0.01). CONCLUSION: The measurement of renin with the chemiluminescent method is a reliable alternative to PRA, having the advantage of a superior inter and intralaboratory reproducibility.
Resumo:
Two likelihood ratio (LR) approaches are presented to evaluate the strength of evidence of MDMA tablet comparisons. The first one is based on a more 'traditional' comparison of MDMA tablets by using distance measures (e.g., Pearson correlation distance or a Euclidean distance). In this approach, LRs are calculated using the distribution of distances between tablets of the same-batch and that of different-batches. The second approach is based on methods used in some other fields of forensic comparison. Here LRs are calculated based on the distribution of values of MDMA tablet characteristics within a specific batch and from all batches. The data used in this paper must be seen as examples to illustrate both methods. In future research the methods can be applied to other and more complex data. In this paper, the methods and their results are discussed, considering their performance in evidence evaluation and several practical aspects. With respect to evidence in favor of the correct hypothesis, the second method proved to be better than the first one. It is shown that the LRs in same-batch comparisons are generally higher compared to the first method and the LRs in different-batch comparisons are generally lower. On the other hand, for operational purposes (where quick information is needed), the first method may be preferred, because it is less time consuming. With this method a model has to be estimated only once in a while, which means that only a few measurements have to be done, while with the second method more measurements are needed because each time a new model has to be estimated.
Resumo:
OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.
Resumo:
The objective of this study was to estimate the potential of method restriction as a public health strategy in suicide prevention. Data from the Swiss Federal Statistical Office and the Swiss Institutes of Forensic Medicine from 2004 were gathered and categorized into suicide submethods according to accessibility to restriction of means. Of suicides in Switzerland, 39.2% are accessible to method restriction. The highest proportions were found in private weapons (13.2%), army weapons (10.4%), and jumps from hot-spots (4.6%). The presented method permits the estimation of the suicide prevention potential of a country by method restriction and the comparison of restriction potentials between suicide methods. In Switzerland, reduction of firearm suicides has the highest potential to reduce the total number of suicides.
Resumo:
OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.