960 resultados para TWO-PHASE PARTITION
Resumo:
Aim: We have previously documented the feasibility of neoadjuvant chemotherapy and EPP in a multicenter trial of MPM (Weder, Ann Oncol 18: 1196, 2007). The objectives of the trimodality trial SAKK17/04 (NCT00334594) were to evaluate the time to loco-regional relapse with or without high dose hemithoracic radiotherapy in a prospective multicenter randomized phase II trial in patients with R0 and R1 resection after neoadjuvant chemotherapy and EPP. Methods: Eligible patients had pathologically confirmed MPM, surgically resectable TNM stage (T1-3 N0-2 M0), PS0-1, ages 18-70 years. Part 1 had a phase II design, and included neoadjuvant chemotherapy with 3 cycles of cisplatin and pemetrexed, followed by restaging and EPP. The primary endpoint of part 1 was complete macroscopic resection (R0-1). Part 2 randomized consenting patients with R0-1 resection into two parallel phase II arms (control arm A and radiotherapy arm B). The primary endpoint for part 2 was loco-regional relapse-free survival (RFS). To detect a 1 year increase with 80% power and 10% alpha, 37 patients were needed for arm B. Secondary endpoints included operability, tolerability of chemotherapy and radiotherapy, survival, and translational research Results: Because accrual of part 2 was slower than planned, the trial was stopped in 2013. Overall, 153 patients entered the trial, of whom 125 underwent surgery and 99 had a complete macroscopic resection (primary endpoint part 1). Of the later patients, 54 could be randomized 1:1 into each arm. Reasons for non-randomization included patient refusal in 24 and ineligibility or protocol deviations in 21. Of the 27 patients randomized to hemithoracic radiotherapy, 25 completed the treatment as planned. For part 1 the median RFS was 8.8 (95%CI: 7.3-10.7) and median OS was 15.0 (95% CI: 12.1-19.3) months. For part 2 the median local RFS for group A was 7.6 (95%CI: 5.5-10.7) and for group B 9.4 (95%CI: 6.5-11.9) months (primary endpoint part 2), while the overall RFS and OS for group A were 5.7 (95%CI: 3.5-8.8) and 16.9 (95%CI: 10.7-23.6) months and for group B 7.6 (95% CI:5.2-10.6) and 14.9 (95%CI: 7.0-17.6) months. Conclusions: This study did not reach the primary endpoint which was defined as one-year increase in loco-regional relapse-free survival and thus does not support the routine use of hemithoracic RT after neoadjuvant chemotherapy and EPP. Disclosure: All authors have declared no conflicts of interest.
Resumo:
Aim: One standard option in the treatment of stage IIIA/N2 NSCLC is neoadjuvant chemotherapy followed by surgery. We investigated in a randomized trial whether the addition of neoadjuvant radiotherapy would improve the outcome. Here we present the final results of this study. Methods: Patients (pts.) with pathologically proven, resectable stage IIIA/N2 NSCLC, performance status 0-1, and adequate organ function were randomized 1:1 to chemoradiation (CRT) with 3 cycles of neoadjuvant chemotherapy (cisplatin 100 mg/m2 and docetaxel 85 mg/m2 d1, q3weeks) followed by accelerated concomitant boost radiotherapy (RT) with 44 Gy in 22 fractions in 3 weeks, or neoadjuvant chemotherapy alone (CT), with subsequent surgery for all pts. The primary endpoint was event-free survival (EFS). Results: 232 pts. were randomized in 23 centers, the median follow-up was 53 months. Two thirds were men, median age was 60 years (range 37-76). Histology was squamous cell in 33%, adenocarcinoma in 43%. Response rate to CRT was 61% vs. 44% with CT. 85% of all pts. underwent surgery, 30-day postoperative mortality was 1%. The rate of complete resection was 91% (CRT) vs. 81% (CT) and the pathological complete remission (pCR) rate was 16% vs. 12%. The median EFS was 13.1 months (95% CI 9.9 - 23.5) for the CRT group vs. 11.8 months (95% CI 8.4 - 15.2) in the CT arm (p 0.665). The median overall survival (OS) with CRT was 37.1 months (95% CI 22.6 -50), with CT 26.1 months ( 95% CI 26.1 - 52.1, p 0.938). The local failure rate was 23% in both arms. In the CT arm 12 pts. were given postoperative radiotherapy (PORT) for R1 resection, 6 pts. received PORT in violation of the protocol. Pts. with a pCR, mediastinal downstaging to ypN0/1 and complete resection had a better outcome. Toxicity of chemotherapy was substantial, especially febrile neutropenia was common, whereas RT was well tolerated. Conclusions: This is the first completed phase III trial to evaluate the role of induction chemoradiotherapy and surgery, in comparison to neoadjuvant CT alone followed by surgery. RT was active, it increased response, complete resection and pCR rates. However, this failed to translate into an improvement of local control, EFS or OS. Notably, surgery after induction treatment was safe, including pneumonectomy. The overall survival rates of our neoadjuvant regimen are very encouraging, especially for a multicenter setting. Disclosure: M. Pless: Advisory Board for Sanofi; R. Cathomas: Advisory Board Sanofi D.C. Betticher: Advisory Board Sanofi. All other authors have declared no conflicts of interest.
Resumo:
BACKGROUND: Postoperative hemithoracic radiotherapy has been used to treat malignant pleural mesothelioma, but it has not been assessed in a randomised trial. We assessed high-dose hemithoracic radiotherapy after neoadjuvant chemotherapy and extrapleural pneumonectomy in patients with malignant pleural mesothelioma. METHODS: We did this phase 2 trial in two parts at 14 hospitals in Switzerland, Belgium, and Germany. We enrolled patients with pathologically confirmed malignant pleural mesothelioma; resectable TNM stages T1-3 N0-2, M0; WHO performance status 0-1; age 18-70 years. In part 1, patients were given three cycles of neoadjuvant chemotherapy (cisplatin 75 mg/m(2) and pemetrexed 500 mg/m(2) on day 1 given every 3 weeks) and extrapleural pneumonectomy; the primary endpoint was complete macroscopic resection (R0-1). In part 2, participants with complete macroscopic resection were randomly assigned (1:1) to receive high-dose radiotherapy or not. The target volume for radiotherapy encompassed the entire hemithorax, the thoracotomy channel, and mediastinal nodal stations if affected by the disease or violated surgically. A boost was given to areas at high risk for locoregional relapse. The allocation was stratified by centre, histology (sarcomatoid vs epithelioid or mixed), mediastinal lymph node involvement (N0-1 vs N2), and T stage (T1-2 vs T3). The primary endpoint of part 1 was the proportion of patients achieving complete macroscopic resection (R0 and R1). The primary endpoint in part 2 was locoregional relapse-free survival, analysed by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT00334594. FINDINGS: We enrolled patients between Dec 7, 2005, and Oct 17, 2012. Overall, we analysed 151 patients receiving neoadjuvant chemotherapy, of whom 113 (75%) had extrapleural pneumonectomy. Median follow-up was 54·2 months (IQR 32-66). 52 (34%) of 151 patients achieved an objective response. The most common grade 3 or 4 toxic effects were neutropenia (21 [14%] of 151 patients), anaemia (11 [7%]), and nausea or vomiting (eight [5%]). 113 patients had extrapleural pneumonectomy, with complete macroscopic resection achieved in 96 (64%) of 151 patients. We enrolled 54 patients in part 2; 27 in each group. The main reasons for exclusion were patient refusal (n=20) and ineligibility (n=10). 25 of 27 patients completed radiotherapy. Median total radiotherapy dose was 55·9 Gy (IQR 46·8-56·0). Median locoregional relapse-free survival from surgery, was 7·6 months (95% CI 4·5-10·7) in the no radiotherapy group and 9·4 months (6·5-11·9) in the radiotherapy group. The most common grade 3 or higher toxic effects related to radiotherapy were nausea or vomiting (three [11%] of 27 patients), oesophagitis (two [7%]), and pneumonitis (two [7%]). One patient died of pneumonitis. We recorded no toxic effects data for the control group. INTERPRETATION: Our findings do not support the routine use of hemithoracic radiotherapy for malignant pleural mesothelioma after neoadjuvant chemotherapy and extrapleural pneumonectomy. FUNDING: Swiss Group for Clinical Cancer Research, Swiss State Secretariat for Education, Research and Innovation, Eli Lilly.
Resumo:
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.
Resumo:
Lorsque de l'essence est employée pour allumer et/ou propager un incendie, l'inférence de la source de l'essence peut permettre d'établir un lien entre le sinistre et une source potentielle. Cette inférence de la source constitue une alternative intéressante pour fournir des éléments de preuve dans ce type d'événements où les preuves matérielles laissées par l'auteur sont rares. Le but principal de cette recherche était le développement d'une méthode d'analyse de spécimens d'essence par GC-IRMS, méthode pas routinière et peu étudiée en science forensique, puis l'évaluation de son potentiel à inférer la source de traces d'essence en comparaison aux performances de la GC-MS. Un appareillage permettant d'analyser simultanément les échantillons par MS et par IRMS a été utilisé dans cette recherche. Une méthode d'analyse a été développée, optimisée et validée pour cet appareillage. Par la suite, des prélèvements d'essence provenant d'un échantillonnage conséquent et représentatif du marché de la région lausannoise ont été analysés. Finalement, les données obtenues ont été traitées et interprétées à l'aide de méthodes chimiométriques. Les analyses effectuées ont permis de montrer que la méthodologie mise en place, aussi bien pour la composante MS que pour l'IRMS, permet de différencier des échantillons d'essence non altérée provenant de différentes stations-service. Il a également pu être démontré qu'à chaque nouveau remplissage des cuves d'une station-service, la composition de l'essence distribuée par cette station est quasi unique. La GC-MS permet une meilleure différenciation d'échantillons prélevés dans différentes stations, alors que la GC-IRMS est plus performante lorsqu'il s'agit de comparer des échantillons collectés après chacun des remplissages d'une cuve. Ainsi, ces résultats indiquent que les deux composantes de la méthode peuvent être complémentaires pour l'analyse d'échantillons d'essence non altérée. Les résultats obtenus ont également permis de montrer que l'évaporation des échantillons d'essence ne compromet pas la possibilité de grouper des échantillons de même source par GC-MS. Il est toutefois nécessaire d'effectuer une sélection des variables afin d'éliminer celles qui sont influencées par le phénomène d'évaporation. Par contre, les analyses effectuées ont montré que l'évaporation des échantillons d'essence a une forte influence sur la composition isotopique des échantillons. Cette influence est telle qu'il n'est pas possible, même en effectuant une sélection des variables, de grouper correctement des échantillons évaporés par GC-IRMS. Par conséquent, seule la composante MS de la méthodologie mise en place permet d'inférer la source d'échantillons d'essence évaporée. _________________________________________________________________________________________________ When gasoline is used to start and / or propagate an arson, source inference of gasoline can allow to establish a link between the fire and a potential source. This source inference is an interesting alternative to provide evidence in this type of events where physical evidence left by the author are rare. The main purpose of this research was to develop a GC-IRMS method for the analysis of gasoline samples, a non-routine method and little investigated in forensic science, and to evaluate its potential to infer the source of gasoline traces compared to the GC-MS performances. An instrument allowing to analyze simultaneously samples by MS and IRMS was used in this research. An analytical method was developed, optimized and validated for this instrument. Thereafter, gasoline samples from a large sampling and representative of the Lausanne area market were analyzed. Finally, the obtained data were processed and interpreted using chemometric methods. The analyses have shown that the methodology, both for MS and for IRMS, allow to differentiate unweathered gasoline samples from different service stations. It has also been demonstrated that each new filling of the tanks of a station generates an almost unique composition of gasoline. GC-MS achieves a better differentiation of samples coming from different stations, while GC-IRMS is more efficient to distinguish samples collected after each filling of a tank. Thus, these results indicate that the two components of the method can be complementary to the analysis of unweathered gasoline samples. The results have also shown that the evaporation of gasoline samples does not compromise the possibility to group samples coming from the same source by GC-MS. It is however necessary to make a selection of variables in order to eliminate those which are influenced by the evaporation. On the other hand, the carried out analyses have shown that the evaporation of gasoline samples has such a strong influence on the isotopic composition of the samples that it is not possible, even by performing a selection of variables, to properly group evaporated samples by GC-IRMS. Therefore, only the MS allows to infer the source of evaporated gasoline samples.
Resumo:
BACKGROUND: The ongoing Ebola outbreak led to accelerated efforts to test vaccine candidates. On the basis of a request by WHO, we aimed to assess the safety and immunogenicity of the monovalent, recombinant, chimpanzee adenovirus type-3 vector-based Ebola Zaire vaccine (ChAd3-EBO-Z). METHODS: We did this randomised, double-blind, placebo-controlled, dose-finding, phase 1/2a trial at the Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland. Participants (aged 18-65 years) were randomly assigned (2:2:1), via two computer-generated randomisation lists for individuals potentially deployed in endemic areas and those not deployed, to receive a single intramuscular dose of high-dose vaccine (5 × 10(10) viral particles), low-dose vaccine (2·5 × 10(10) viral particles), or placebo. Deployed participants were allocated to only the vaccine groups. Group allocation was concealed from non-deployed participants, investigators, and outcome assessors. The safety evaluation was not masked for potentially deployed participants, who were therefore not included in the safety analysis for comparison between the vaccine doses and placebo, but were pooled with the non-deployed group to compare immunogenicity. The main objectives were safety and immunogenicity of ChAd3-EBO-Z. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT02289027. FINDINGS: Between Oct 24, 2014, and June 22, 2015, we randomly assigned 120 participants, of whom 18 (15%) were potentially deployed and 102 (85%) were non-deployed, to receive high-dose vaccine (n=49), low-dose vaccine (n=51), or placebo (n=20). Participants were followed up for 6 months. No vaccine-related serious adverse events were reported. We recorded local adverse events in 30 (75%) of 40 participants in the high-dose group, 33 (79%) of 42 participants in the low-dose group, and five (25%) of 20 participants in the placebo group. Fatigue or malaise was the most common systemic adverse event, reported in 25 (62%) participants in the high-dose group, 25 (60%) participants in the low-dose group, and five (25%) participants in the placebo group, followed by headache, reported in 23 (57%), 25 (60%), and three (15%) participants, respectively. Fever occurred 24 h after injection in 12 (30%) participants in the high-dose group and 11 (26%) participants in the low-dose group versus one (5%) participant in the placebo group. Geometric mean concentrations of IgG antibodies against Ebola glycoprotein peaked on day 28 at 51 μg/mL (95% CI 41·1-63·3) in the high-dose group, 44·9 μg/mL (25·8-56·3) in the low-dose group, and 5·2 μg/mL (3·5-7·6) in the placebo group, with respective response rates of 96% (95% CI 85·7-99·5), 96% (86·5-99·5), and 5% (0·1-24·9). Geometric mean concentrations decreased by day 180 to 25·5 μg/mL (95% CI 20·6-31·5) in the high-dose group, 22·1 μg/mL (19·3-28·6) in the low-dose group, and 3·2 μg/mL (2·4-4·9) in the placebo group. 28 (57%) participants given high-dose vaccine and 31 (61%) participants given low-dose vaccine developed glycoprotein-specific CD4 cell responses, and 33 (67%) and 35 (69%), respectively, developed CD8 responses. INTERPRETATION: ChAd3-EBO-Z was safe and well tolerated, although mild to moderate systemic adverse events were common. A single dose was immunogenic in almost all vaccine recipients. Antibody responses were still significantly present at 6 months. There was no significant difference between doses for safety and immunogenicity outcomes. This acceptable safety profile provides a reliable basis to proceed with phase 2 and phase 3 efficacy trials in Africa. FUNDING: Swiss State Secretariat for Education, Research and Innovation (SERI), through the EU Horizon 2020 Research and Innovation Programme.
Resumo:
The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.
Resumo:
Several bioaffinity assays are based on the detection of an analyte which is bound on a solid substrate via biochemical interaction. These so called solid phase assays are based on the adhesion of the primary binding partner on a solid surface, which then binds the analyte to be detected. In this thesis work a novel solid phase based assay technology, known as spot technology, was developed. The spot technology is based on combination of high-capacity solid phases, concentrated in a spot format, utilising modified streptavidin molecules and recombinant antibody fragments. The reduction of the solid phase binding surface to a size of a spot enabled denser binding of the target molecules, providing improved signal intensities and signal-to-background ratio when applied in different solid phase immunoassays. Streptavidin-biotin interactions are commonly utilised in numerous different bioaffinity assays and the ultimate nature of streptavidin to bind biotin is among the strongest non-covalent interaction reported between two biomolecules. In this study native core streptavidin was chemically modified to provide polymerised streptavidin molecules with altered adsorption properties. These streptavidin conjugates, when coated onto polystyrene surface, provided enhanced biotin binding capacity and surface stability when compared to a reference coating constructed with native streptavidin. Furthermore, the combination of chemically modified streptavidin, sitespecifically biotinylated antibody fragments and the spot coating technology provided highly dense solid phase coating with improved binding properties. The performance of the spot assay technology was further demonstrated in different immunoassay configurations. Human thyroid stimulating hormone (TSH) and human cardiac troponin I (cTnI) were used as model analytes to show the applicability of the highly sensitive spot-based solid-phase immunoassay for detection of very low levels of analytes. It was demonstrated that the spot technology provided an assay concept with enhanced sensitivity and short turn-around times, characteristics that are highly suitable for point-of-care applications.
Resumo:
A simple and effective route has been developed for the synthesis of bimodal (3.6 and 9.4 nm) mesoporous silica materials that have two ordered interconnected pore networks. Mesostructures have been prepared through the self assembly mechanism by using a mixture of polyoxyethylene fluoroalkyl ether and triblock copolymer as building block. The investigation of the RF8(EO)9/P123/water phase diagram evidences that in the considered surfactant range of concentrations, the system is micellar (L1). DLS measurements indicate that this micellar phase is composed of two types of micelles, the size of the first one at around 7.6 nm corresponds unambiguously to the pure fluorinated micelles. The second type of micelles at higher diameter consists of fluorinated micelles which have accommodated a weak fraction of P123 molecules. Thus, in this study the bimodal mesoporous silica are really templated by two kinds of micelles.
Resumo:
The product of catalytic activity of the enzyme phospholipase A2, which resembles the core unit of animal toxins, on phospholipids is a 1:1 mixture of lysolipid and fatty acid. This mixture was studied by time-resolved simultaneous small- and wide angle x-ray diffraction over the temperature range from 23 to 53.5ºC. An unusually large lamellar structure was observed, with d = 11 nm, contradicting the complex functional dimer model between lysolipid and fatty acid. It can be explained by formation of a "double-bilayer", a new phase consisting of two different bilayers, one formed by lysophospholipid and other by fatty acid, bound together by head group interactions. Its strucutre was confirmed by simulations of the X-ray scattering pattern.
Resumo:
In the present work, the crude ethanol extract from wood of G. macrophylla was submitted to liquid/liquid partition between hexane, CH2Cl2, EtOAc and n-BuOH. Each phase was individually chromatographed over silica gel, Sephadex LH-20 or Amberlite XAD-2 to give eight terpene derivatives, such as five sesquiterpenoids (caryophyllene oxide, guai-6-en-10β-ol, spathulenol, aromadendrane-4β,10α-diol and aloaromadendrane-4α,10β-diol) as well as three triterpenoids (cicloart-24-ene-3β,23(R*)-diol, cicloart-24-ene-3β,23(S*)-diol, and cicloart-23E-ene-3β,25-diol). Additionally, were isolated three fatty acids (linolenic, linoleic and stearic), two steroids (sitosterol and stigmasterol) and sacarose. The structures of all these compounds were characterized by spectrometric analysis, mainly mass spectrometry and NMR and comparison of these data described in the literature.
Resumo:
A neural network procedure to solve inverse chemical kinetic problems is discussed in this work. Rate constants are calculated from the product concentration of an irreversible consecutive reaction: the hydrogenation of Citral molecule, a process with industrial interest. Simulated and experimental data are considered. Errors in the simulated data, up to 7% in the concentrations, were assumed to investigate the robustness of the inverse procedure. Also, the proposed method is compared with two common methods in nonlinear analysis; the Simplex and Levenberg-Marquardt approaches. In all situations investigated, the neural network approach was numerically stable and robust with respect to deviations in the initial conditions or experimental noises.
Resumo:
In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.