938 resultados para TANDEM MASS-SPECTROMETRY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a comparison of adaptations of the QuEChERS (quick, easy, cheap, effective, rugged and safe) approach for the determination of 14 organochlorine pesticide (OCP) residues in strawberry jam by concurrent use of gas chromatography (GC) coupled to electron capture detector (ECD) and GC tandem mass spectrometry (GC-MS/MS). Three versions were tested based on the original QuEChERS method. The results were good (overall average of 89% recoveries with 15% RSD) using the ultrasonic bath at five spiked levels. Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), were determined for each pesticide. LOD ranged from 0.8 to 8.9 microg kg-1 ; LOQ was in the range of 2.5–29.8 microg kg- 1; and calibration curves were linear (r2>0.9970) in the whole range of the explored concentrations (5–100 microg kg- 1). The LODs of these pesticides were much lower than the maximum residue levels (MRLs) allowed in Europe for strawberries. The method was successfully applied to the quantification of OCP in commercially available jams. The OCPs were detected lower than the LOD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 μg kg−1 for fluazifop-pbutyl to 50 μg kg−1 for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advanced glycation end-products are Maillard reaction products that are found in thermal processed food. This compounds are often referred as unhealthy for human diet, namely because of their capacity to form amino-acid dimers. There is a broad range of answers to get about how these products are formed, how they interact with the organism and how these reactions can be inhibited to prevent the referred effects. Some compounds from garlic are thought to be able to inhibit these reactions. This study using spectrophotometric, High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) and Fourier transformed infrared spectroscopy (FTIR) analysis, helps to understand better not only not only the effect of some compounds obtained from garlic, diallyl sulfide (DAS), diallyl disulfide (DADS) and diallyl trisulfide (DATS), on these AGEs production reaction, but also helped to understand better the reaction itself.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical methodology for the simultaneous determination of seven pharmaceuticals and two metabolites belonging to the non-steroidal anti-inflammatory drugs (NSAIDs) and analgesics therapeutic groups was developed based on off-line solid-phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry (SPE–UHPLC–MS/MS). Extraction conditions were optimized taking into account parameters like sorbent material, sample volume and sample pH. Method detection limits (MDLs) ranging from 0.02 to 8.18 ng/L were obtained. This methodology was successfully applied to the determination of the selected pharmaceuticals in seawater samples of Atlantic Ocean in the Northern Portuguese coast. All the pharmaceuticals have been detected in the seawater samples, with pharmaceuticals like ibuprofen, acetaminophen, ketoprofen and the metabolite hydroxyibuprofen being the most frequently detected at concentrations that can reach some hundreds of ng/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atazanavir inhibits UDP-glucuronyl-transferase-1A1 (UGT1A1), which metabolizes raltegravir, but the magnitude of steady-state inhibition and role of the UGT1A1 genotype are unknown. Sufficient inhibition could lead to reduced-dose and -cost raltegravir regimens. Nineteen healthy volunteers, age 24 to 51 years, took raltegravir 400 mg twice daily (arm A) and 400 mg plus atazanavir 400 mg once daily (arm B), separated by ?3 days, in a crossover design. After 1 week on each regimen, raltegravir and raltegravir-glucuronide plasma and urine concentrations were measured by liquid chromatography-tandem mass spectrometry in multiple samples obtained over 12 h (arm A) or 24 h (arm B) and analyzed by noncompartmental methods. UGT1A1 promoter variants were detected with a commercially available kit and published primers. The primary outcome was the ratio of plasma raltegravir C(tau), or concentration at the end of the dosing interval, for arm B (24 h) versus arm A (12 h). The arm B-to-arm A geometric mean ratios (95% confidence interval, P value) for plasma raltegravir C(tau), area under the concentration-time curve from 0 to 12 h (AUC(0-12)), and raltegravir-glucuronide/raltegravir AUC(0-12) were 0.38 (0.22 to 0.65, 0.001), 1.32 (0.62 to 2.81, 0.45), and 0.47 (0.38 to 0.59, <0.001), respectively. Nine volunteers were heterozygous and one was homozygous for a UGT1A1 reduction-of-function allele, but these were not associated with metabolite formation. Although atazanavir significantly reduced the formation of the glucuronide metabolite, its steady-state boosting of plasma raltegravir did not render the C(tau) with a once-daily raltegravir dose of 400 mg similar to the C(tau) with the standard twice-daily dose. UGT1A1 promoter variants did not significantly influence this interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eukaryotic cells generate energy in the form of ATP, through a network of mitochondrial complexes and electron carriers known as the oxidative phosphorylation system. In mammals, mitochondrial complex I (CI) is the largest component of this system, comprising 45 different subunits encoded by mitochondrial and nuclear DNA. Humans diagnosed with mutations in the gene NDUFS4, encoding a nuclear DNA-encoded subunit of CI (NADH dehydrogenase ubiquinone Fe-S protein 4), typically suffer from Leigh syndrome, a neurodegenerative disease with onset in infancy or early childhood. Mitochondria from NDUFS4 patients usually lack detectable NDUFS4 protein and show a CI stability/assembly defect. Here, we describe a recessive mouse phenotype caused by the insertion of a transposable element into Ndufs4, identified by a novel combined linkage and expression analysis. Designated Ndufs4(fky), the mutation leads to aberrant transcript splicing and absence of NDUFS4 protein in all tissues tested of homozygous mice. Physical and behavioral symptoms displayed by Ndufs4(fky/fky) mice include temporary fur loss, growth retardation, unsteady gait, and abnormal body posture when suspended by the tail. Analysis of CI in Ndufs4(fky/fky) mice using blue native PAGE revealed the presence of a faster migrating crippled complex. This crippled CI was shown to lack subunits of the "N assembly module", which contains the NADH binding site, but contained two assembly factors not present in intact CI. Metabolomic analysis of the blood by tandem mass spectrometry showed increased hydroxyacylcarnitine species, implying that the CI defect leads to an imbalanced NADH/NAD(+) ratio that inhibits mitochondrial fatty acid β-oxidation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: To update the prevalence of vitamin D insufficiency and to identify factors associated with vitamin D status in the Swiss adult population. METHODS: Data from the 2010-2011 Swiss Study on Salt intake, a population-based study in the Swiss population, was used. Vitamin D concentration in serum was measured by liquid chromatography- tandem mass spectrometry. Major factors that influence vitamin D levels were taken into account. Survey statistical procedures were used to estimate means and prevalences of vitamin D levels and status. Monthly-specific tertiles of vitamin D and ordinal logistic regression were used to determine the associations of covariates of interest with vitamin D status. RESULTS: The prevalences of vitamin D insufficiency (serum 25-hydroxyvitamin D: 20-29.9 ng/ml) and deficiency (<20 ng/ml) were the highest in the January-March period; 26.4% (95%CI: 21.6-31.7) and 61.6% (95%CI: 56.0-67.0), respectively. In the same period, more than 9 of ten men were vitamin D insufficient or deficient. Each unit increase of Body Mass Index was associated with an 8% decreased likelihood of being in a higher vitamin D tertiles. Oral contraceptive, altitude, urinary excretion of calcium, use of vitamin D supplement or treatment, high wine consumption, physical activity were associated with vitamin D tertiles. Compared to the French-speaking region, the Italian-speaking region was independently associated with a higher likelihood of being in higher vitamin D tertiles (OR: 1.66, 95%CI: 1.14-2.43). CONCLUSIONS: Low levels of vitamin D are common among Swiss adults, in particular during winter months and outside the Italian-speaking region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Repeated antimalarial treatment for febrile episodes and self-treatment are common in malaria-endemic areas. The intake of antimalarials prior to participating in an in vivo study may alter treatment outcome and affect the interpretation of both efficacy and safety outcomes. We report the findings from baseline plasma sampling of malaria patients prior to inclusion into an in vivo study in Tanzania and discuss the implications of residual concentrations of antimalarials in this setting. In an in vivo study conducted in a rural area of Tanzania in 2008, baseline plasma samples from patients reporting no antimalarial intake within the last 28 days were screened for the presence of 14 antimalarials (parent drugs or metabolites) using liquid chromatography-tandem mass spectrometry. Among the 148 patients enrolled, 110 (74.3%) had at least one antimalarial in their plasma: 80 (54.1%) had lumefantrine above the lower limit of calibration (LLC = 4 ng/mL), 7 (4.7%) desbutyl-lumefantrine (4 ng/mL), 77 (52.0%) sulfadoxine (0.5 ng/mL), 15 (10.1%) pyrimethamine (0.5 ng/mL), 16 (10.8%) quinine (2.5 ng/mL) and none chloroquine (2.5 ng/mL). The proportion of patients with detectable antimalarial drug levels prior to enrollment into the study is worrying. Indeed artemether-lumefantrine was supposed to be available only at government health facilities. Although sulfadoxine-pyrimethamine is only recommended for intermittent preventive treatment in pregnancy (IPTp), it was still widely used in public and private health facilities and sold in drug shops. Self-reporting of previous drug intake is unreliable and thus screening for the presence of antimalarial drug levels should be considered in future in vivo studies to allow for accurate assessment of treatment outcome. Furthermore, persisting sub-therapeutic drug levels of antimalarials in a population could promote the spread of drug resistance. The knowledge on drug pressure in a given population is important to monitor standard treatment policy implementation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecular evidence suggests that levels of vitamin D are associated with kidney function loss. Still, population-based studies are limited and few have considered the potential confounding effect of baseline kidney function. This study evaluated the association of serum 25-hydroxyvitamin D with change in eGFR, rapid eGFR decline, and incidence of CKD and albuminuria. Baseline (2003-2006) and 5.5-year follow-up data from a Swiss adult general population were used to evaluate the association of serum 25-hydroxyvitamin D with change in eGFR, rapid eGFR decline (annual loss >3 ml/min per 1.73 m(2)), and incidence of CKD and albuminuria. Serum 25-hydroxyvitamin D was measured at baseline using liquid chromatography-tandem mass spectrometry. eGFR and albuminuria were collected at baseline and follow-up. Multivariate linear and logistic regression models were used considering potential confounding factors. Among the 4280 people included in the analysis, the mean±SD annual eGFR change was -0.57±1.78 ml/min per 1.73 m(2), and 287 (6.7%) participants presented rapid eGFR decline. Before adjustment for baseline eGFR, baseline 25-hydroxyvitamin D level was associated with both mean annual eGFR change and risk of rapid eGFR decline, independently of baseline albuminuria. Once adjusted for baseline eGFR, associations were no longer significant. For every 10 ng/ml higher baseline 25-hydroxyvitamin D, the adjusted mean annual eGFR change was -0.005 ml/min per 1.73 m(2) (95% confidence interval, -0.063 to 0.053; P=0.87) and the risk of rapid eGFR decline was null (odds ratio, 0.93; 95% confidence interval, 0.79 to 1.08; P=0.33). Baseline 25-hydroxyvitamin D level was not associated with incidence of CKD or albuminuria. The association of 25-hydroxyvitamin D with eGFR decline is confounded by baseline eGFR. Sufficient 25-hydroxyvitamin D levels do not seem to protect from eGFR decline independently from baseline eGFR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatocellular Carcinoma (HCC) is a major healthcare problem, representing the third most common cause of cancer-related mortality worldwide. Chronic infections with Hepatitis B virus (HBV) and/or Hepatitis C virus (HCV) are the major risk factors for the development of HCC. The incidence of HBV -associated HCC is in decline as a result of an effective HBV vaccine; however, since an equally effective HCV vaccine has not yet been developed, there are 130 million HCV infected patients worldwide who are at a high-risk for developing HCC. Because reliable parameters and/or tools for the early detection of HCC among high-risk individuals are severely lacking, HCC patients are always diagnosed at a late stage where surgical solutions or effective treatment are not possible. Using urine as a non-invasive sample source, two different approaches (proteomic-based and genomic-based approaches) were pursued with the common goal of discovering potential biomarker candidates for the early detection of HCC among high-risk chronic HCV infected patients. Urine was collected from 106 HCV infected Egyptian patients, 32 of whom had already developed HCC and 74 patients who were diagnosed as HCC-free at the time of initial sample collection. In addition to these patients, urine samples were also collected from 12 healthy control individuals. Total urinary proteins, Trans-renal nucleic acid (Tr-NA) and microRNA (miRNA) were isolated from urine using novel methodologies and silicon carbide-loaded spin columns. In the first, "proteomic-based", approach, liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was used to identify potential candidates from pooled urine samples. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR (qRT-PCR). This approach revealed that significant over-expression of three proteins: DJ-1, Chromatin Assembly Factor-1 (CAF-1) and 11 Moemen Abdalla HCC Biomarkers Heat Shock Protein 60 (HSP60), were characteristic events among HCC-post HCV infected patients. As a single-based HCC biomarker, CAF-1 over-expression identified HCC among HCV infected patients with a specificity of 90%, sensitivity of 66% and with an overall diagnostic accuracy of 78%. Moreover, the CAF-lIHSP60 tandem identified HCC among HCV infected patients with a specificity of 92%, sensitivity of 61 % and with an overall diagnostic accuracy of 77%. In the second genomic-based approach, two different approaches were processed. The first approach was the miRNA-based approach. The expression levels of miRNAs isolated from urine were studied using the Illumina MicroRNA Expression Profiling Assay. This was followed by qRT-PCR-based validation of deregulated expression of identified miRNA candidates among all the patients. This approach shed the light on the deregulated expression of a number of miRNAs, which may have a role in either the development of HCC among HCV infected patients (i.e. miR-640, miR-765, miR-200a, miR-521 and miR-520) or may allow for a better understanding of the viral-host interaction (miR-152, miR-486, miR-219, miR452, miR-425, miR-154 and miR-31). Moreover, the deregulated expression of both miR-618 and miR-650 appeared to be a common event among HCC-post HCV infected patients. The results of the search for putative targets of these two miRNA suggested that miR-618 may be a potent oncogene, as it targets the tumor-suppressor gene Low density lipoprotein-related protein 12 (LPR12), while miR-650 may be a potent tumor-suppressor gene, as it is supposed to downregulate the TNF receptor-associated factor-4 (TRAF4) oncogene. The specificity of miR-618 and miR-650 deregulated expression patterns for the early detection of HCC among HCV infected patients was 68% and 58%, respectively, whereas the sensitivity was 64% and 72%, respectively. When the deregulated expression of both miRNAs was combined as a tandem biomarker, the specificity and the sensitivity were 75% and 58% respectively. 111 Moemen Abdalla HCC Biomarkers In the second, "Trans-renal nucleic acid-based", approach, the urinary apoptotic nucleic acid (uaNA) levels of 70ng/mL or more were found to be a good predictor of HCC among chronic HCV infected patients. The specificity and the sensitivity of this diagnostic approach were 76% and 86%, respectively, with an overall diagnostic value of 81 %. The uaNA levels positively correlated to HCC disease progression as monitored by epigenetic changes of a panel of eight tumor-suppressor genes (TSGs) using methylation-sensitive PCR. Moreover, the pairing of high uaNA levels (:::: 70 ng/mL) and CAF-1 over-expreSSIOn produced a highly specific (l 00%) multiple-based HCC biomarker with an acceptable sensitivity of 64%, and with a diagnostic accuracy of 82%. In comparison to the previous pairing, the uaNA levels (:::: 70 ng/mL) in tandem with HSP60 over-expression was less specific (89%) but highly sensitive (72%), resulting in a diagnostic accuracy of 64%. The specificities of miR-650 deregulated expression in combination with either high uaNA content or HSP 60 over-expression were 82% and 79%, respectively, whereas, the sensitivities of these combinations were 64% and 58%, respectively. The potential biomarkers identified in this study compare favorably with the diagnostic accuracy of the a-fetoprotein levels test, which has a specificity of 75%, sensitivity of 68% and an overall diagnostic accuracy of 70%. Here we present an intriguing study which shows the significance of using urine as a noninvasive sample source for the identification of promising HCC biomarkers. We have also introduced new techniques for the isolation of different urinary macromolecules, especially miRNA, from urine. Furthermore, we strongly recommend the potential biomarkers indentified in this study as focal points of any future research on HCC diagnosis. A larger testing pool will determine if their use is practical for mass population screening. This explorative study identified potential targets that merit further investigation for the development of diagnostically accurate biomarkers isolated from 1-2 mL urine samples that were acquired in a non-invasive manner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il est reconnu que le benzène, le toluène, l’éthylbenzène et les isomères du xylène, composés organiques volatils (COVs) communément désignés BTEX, produisent des effets nocifs sur la santé humaine et sur les végétaux dépendamment de la durée et des niveaux d’exposition. Le benzène en particulier est classé cancérogène et une exposition à des concentrations supérieures à 64 g/m3 de benzène peut être fatale en 5–10 minutes. Par conséquent, la mesure en temps réel des BTEX dans l’air ambiant est essentielle pour détecter rapidement un danger associé à leur émission dans l’air et pour estimer les risques potentiels pour les êtres vivants et pour l’environnement. Dans cette thèse, une méthode d’analyse en temps réel des BTEX dans l’air ambiant a été développée et validée. La méthode est basée sur la technique d’échantillonnage direct de l’air couplée avec la spectrométrie de masse en tandem utilisant une source d’ionisation chimique à pression atmosphérique (APCI-MS/MS directe). La validation analytique a démontré la sensibilité (limite de détection LDM 1–2 μg/m3), la précision (coefficient de variation CV < 10%), l’exactitude (exactitude > 95%) et la sélectivité de la méthode. Des échantillons d’air ambiant provenant d’un site d’enfouissement de déchets industriels et de divers garages d’entretien automobile ont été analysés par la méthode développée. La comparaison des résultats avec ceux obtenus par la technique de chromatographie gazeuse on-line couplée avec un détecteur à ionisation de flamme (GC-FID) a donné des résultats similaires. La capacité de la méthode pour l’évaluation rapide des risques potentiels associés à une exposition aux BTEX a été prouvée à travers une étude de terrain avec analyse de risque pour la santé des travailleurs dans trois garages d’entretien automobile et par des expériences sous atmosphères simulées. Les concentrations mesurées dans l’air ambiant des garages étaient de 8,9–25 µg/m3 pour le benzène, 119–1156 µg/m3 pour le toluène, 9–70 µg/m3 pour l’éthylbenzène et 45–347 µg/m3 pour les xylènes. Une dose quotidienne environnementale totale entre 1,46 10-3 et 2,52 10-3 mg/kg/jour a été déterminée pour le benzène. Le risque de cancer lié à l’exposition environnementale totale au benzène estimé pour les travailleurs étudiés se situait entre 1,1 10-5 et 1,8 10-5. Une nouvelle méthode APCI-MS/MS a été également développée et validée pour l’analyse directe de l’octaméthylcyclotétrasiloxane (D4) et le décaméthylcyclopentasiloxane (D5) dans l’air et les biogaz. Le D4 et le D5 sont des siloxanes cycliques volatils largement utilisés comme solvants dans les processus industriels et les produits de consommation à la place des COVs précurseurs d’ozone troposphérique tels que les BTEX. Leur présence ubiquitaire dans les échantillons d’air ambiant, due à l’utilisation massive, suscite un besoin d’études de toxicité. De telles études requièrent des analyses qualitatives et quantitatives de traces de ces composés. Par ailleurs, la présence de traces de ces substances dans un biogaz entrave son utilisation comme source d’énergie renouvelable en causant des dommages coûteux à l’équipement. L’analyse des siloxanes dans un biogaz s’avère donc essentielle pour déterminer si le biogaz nécessite une purification avant son utilisation pour la production d’énergie. La méthode développée dans cette étude possède une bonne sensibilité (LDM 4–6 μg/m3), une bonne précision (CV < 10%), une bonne exactitude (> 93%) et une grande sélectivité. Il a été également démontré qu’en utilisant cette méthode avec l’hexaméthyl-d18-disiloxane comme étalon interne, la détection et la quantification du D4 et du D5 dans des échantillons réels de biogaz peuvent être accomplies avec une meilleure sensibilité (LDM ~ 2 μg/m3), une grande précision (CV < 5%) et une grande exactitude (> 97%). Une variété d’échantillons de biogaz prélevés au site d’enfouissement sanitaire du Complexe Environnemental de Saint-Michel à Montréal a été analysée avec succès par cette nouvelle méthode. Les concentrations mesurées étaient de 131–1275 µg/m3 pour le D4 et 250–6226 µg/m3 pour le D5. Ces résultats représentent les premières données rapportées dans la littérature sur la concentration des siloxanes D4 et D5 dans les biogaz d’enfouissement en fonction de l’âge des déchets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les phytochélatines (PC) sont des polypeptides ayant la structure générale, (alpha-Glu-Cys)n-Gly, où n = 2 à 11. Leur synthèse est induite par un grand nombre de végétaux en réponse à une élévation de la concentration du milieu en métaux, en particulier le cadmium (ci-après, Cd). Le but de cette étude a été de développer un outil pour évaluer la biodisponibilité du Cd dans les eaux douces. Pour ce faire, une méthode analytique a été réalisée afin de déterminer les phytochélatines induites dans les algues C. reinhardtii. Celle-ci consiste à utiliser la chromatographie liquide couplée à la spectrométrie de masse en tandem (LCHP-SM/SM) "on-line". L’ionisation des molécules est celle faite par électronébulisation (IEN) (traduction de electrospray ionisation). L’objectif principal de ce mémoire est la validation de cette méthode : la détermination des courbes de calibration et des limites de détection et l'identification d'interférences potentielles. L’utilisation de dithiothreitol (DTT) à une concentration de 25 mM a été nécessaire à la conservation de la forme réduite des phytochélatines. En effet, suite à la validation de la méthode d’analyse des phytochélatines il a été démontré qu’elle représente un potentiel d’application. Ceci dans la mesure où l’induction des phytochélatines (PC2, PC3 et PC4) dans les algues C. reinhardtii a été possible à deux concentrations de Cd (1 x 10-7 M et 1 x 10 6 M) et ce, après plusieurs temps d'induction (1, 2, 4, et 6 h). Ainsi, l’étude de la stabilité des phytochélatines a été réalisée et toutes les températures examinées ont démontré une diminution des phytochélatines analysées par HPLC-ESI-MS/MS. Il se pourrait que la cause de la dégradation des phytochélatines soit physique ou chimique plutôt que bactérienne. Toutefois, un approfondissement au niveau de la purification de la solution d’extraction serait nécessaire à la mise au point de la dite méthode analytique afin de quantifier les phytochélatines dans l’algue C. reinhardtii.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les biomarqueurs plasmatiques constituent des outils essentiels, mais rares, utilisés pour diagnostiquer les maladies, comme les maladies cardiovasculaires (MCV), et stratifier le niveau de risque associé. L’identification de nouveaux biomarqueurs plasmatiques susceptibles d’améliorer le dépistage et le suivi des MCV représente ainsi un enjeu majeur en termes d’économie et de santé publique. Le projet vise à identifier de nouveaux biomarqueurs plasmatiques prédictifs ou diagnostiques des MCV, à déterminer le profil protéomique plasmatique de patients atteints de MCV et à développer des méthodes innovantes d’analyse d’échantillon plasmatique. L’étude a été effectuée sur une large banque de plasma provenant de 1006 individus de souche Canadienne-Française recrutés à différents stades de la MCV et qui ont été suivis sur une période de 5 ans. Des séries de déplétions ont été réalisées afin de dépléter les 14 protéines majoritaires (colonne IgY14TM) de l’échantillon avant son analyse par trois approches effectuées en parallèle: 1) Une chromatographie liquide (LC) en 2 dimensions qui fractionne les protéines selon le point isoélectrique puis selon le degré d’hydrophobicité, via le système PF2D, suivie par une chromatographie liquide couplée avec une spectrométrie de masse en tandem (LC-MS/MS). 2) Une séparation classique sur gel 1D-SDS-PAGE suivie d’une LC-MS/MS; 3) Par une déplétion plus poussée du plasma avec l’utilisation en tandem avec la colonne IgY14TM d’une colonne SupermixTM permettant de dépléter également les protéines de moyenne abondance, suivie d’une séparation sur gel 1D-SDS-PAGE et d’une analyse LC-MS/MS de la portion déplétée (3a) et de la portion liée à la SupermixTM (3b). Les résultats montrent que le système PF2D permet d’identifier plusieurs profils protéiques spécifiques au groupe MCV. Sur un total de 1156 fractions (équivalent à 1172 pics protéiques pour le groupe contrôle et 926 pics pour le groupe MCV) recueillies, 15 fractions (23 pics protéiques) présentaient des différences quantitativement significatives (p<0,05) entre les 2 groupes. De plus, 6 fractions (9 pics) sont uniquement présentes dans un groupe, représentant d’autres signatures protéomiques et biomarqueurs potentiellement intéressants. Les méthodes 2, 3a et 3b ont permis l’identification de 108, 125 et 91 protéines respectivement avec des chevauchements partiels (31% entre la méthode 2 et 3a, 61% entre 2 et 3b et 19% entre 3a et 3b). Les méthodes 2 et 3 ont permis l’identification de 12 protéines qui présentaient des différences quantitatives significatives entre les 2 groupes. L’utilisation de plusieurs approches protéomiques complémentaires nous ont d’ores et déjà permis d’identifier des candidats biomarqueurs des angines instables avec récidive d’infarctus du myocarde (IM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avec la hausse mondiale de la fréquence des floraisons de cyanobactéries (CB), dont certaines produisent des cyanotoxines (CT), le développement d’une méthode de détection/quantification rapide d’un maximum de CT s’impose. Cette méthode permettrait de faire un suivi quotidien de la toxicité de plans d’eau contaminés par des CB et ainsi d’émettre rapidement des avis d’alerte appropriés afin de protéger la santé publique. Une nouvelle technologie utilisant la désorption thermique induite par diode laser (LDTD) couplée à l’ionisation chimique sous pression atmosphérique (APCI) et reliée à la spectrométrie de masse en tandem (MS/MS) a déjà fait ses preuves avec des temps d'analyse de l’ordre de quelques secondes. Les analytes sont désorbés par la LDTD, ionisés en phase gazeuse par APCI et détectés par la MS/MS. Il n’y a donc pas de séparation chromatographique, et la préparation de l’échantillon avant l’analyse est minimale selon la complexité de la matrice contenant les analytes. Parmi les quatre CT testées (microcystine-LR, cylindrospermopsine, saxitoxine et anatoxine-a (ANA-a)), seule l’ANA-a a généré une désorption significative nécessaire au développement d’une méthode analytique avec l’interface LDTD-APCI. La forte polarité ou le poids moléculaire élevé des autres CT empêche probablement leur désorption. L’optimisation des paramètres instrumentaux, tout en tenant compte de l’interférence isobarique de l’acide aminé phénylalanine (PHE) lors de la détection de l’ANA-a par MS/MS, a généré une limite de détection d’ANA-a de l’ordre de 1 ug/L. Celle-ci a été évaluée à partir d’une matrice apparentée à une matrice réelle, démontrant qu’il serait possible d’utiliser la LDTD pour effectuer le suivi de l’ANA-a dans les eaux naturelles selon les normes environnementales applicables (1 à 12 ug/L). Il a été possible d’éviter l’interférence isobarique de la PHE en raison de sa très faible désorption avec l’interface LDTD-APCI. En effet, il a été démontré qu’une concentration aussi élevée que 500 ug/L de PHE ne causait aucune interférence sur le signal de l’ANA-a.