929 resultados para System reliability index


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This pilot study explored the feasibility and effectiveness of an Internet-based telerehabilitation application for the assessment of motor speech disorders in adults with acquired neurological impairment. Method: Using a counterbalanced, repeated measures research design, 2 speech-language pathologists assessed 19 speakers with dysarthria on a battery of perceptual assessments. The assessments included a 19-item version of the Frenchay Dysarthria Assessment (FDA; P. Enderby, 1983), the Assessment of Intelligibility of Dysarthric Speech (K. M. Yorkston & D. R. Beukelman, 1981), perceptual analysis of a speech sample, and an overall rating of severity of the dysarthria. One assessment was conducted in the traditional face-to-face manner, whereas the other assessment was conducted using an online, custom-built telerehabilitation application. This application enabled real-time videoconferencing at 128 kb/s and the transfer of store-and-forward audio and video data between the speaker and speech-language pathologist sites. The assessment methods were compared using the J.M.Bland and D.G.Altman (1986, 1999) limits-of-agreement method and percentage level of agreement between the 2 methods. Results: Measurements of severity of dysarthria, percentage intelligibility in sentences, and most perceptual ratings made in the telerehabilitation environment were found to fall within the clinically acceptable criteria. However, several ratings on the FDA were not comparable between the environments, and explanations for these results were explored. Conclusions: The online assessment of motor speech disorders using an Internet-based telerehabilitation system is feasible. This study suggests that with additional refinement of the technology and assessment protocols, reliable assessment of motor speech disorders over the Internet is possible. Future research methods are outlined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present investigation aimed to critically examine the factor structure and psychometric properties of the Anxiety Sensitivity Index - Revised (ASI-R). Confirmatory factor analysis using a clinical sample of adults (N = 248) revealed that the ASI-R could be improved substantially through the removal of 15 problematic items in order to account for the most robust dimensions of anxiety sensitivity. This modified scale was renamed the 21-item Anxiety Sensitivity Index (21-item ASI) and reanalyzed with a large sample of normative adults (N = 435), revealing configural and metric invariance across groups. Further comparisons with other alternative models, using multi-sample analysis, indicated the 21-item ASI to be the best fitting model for both groups. There was also evidence of internal consistency, test-retest reliability, and construct validity for both samples suggesting that the 21-item ASI is a useful assessment device for investigating the construct of anxiety sensitivity in both clinical and normative populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary objectives: (1) To investigate the Nonword Repetition test (NWR) as an index of sub-vocal rehearsal deficits after mild traumatic brain injury (mTBI); (2) to assess the reliability, validity and sensitivity of the NWR; and (3) to compare the NWR to more sensitive tests of verbal memory. Research design: An independent groups design. Methods and procedures: Study 1 administered the NWR to 46 mTBI and 61 uninjured controls with the Rapid Screen of Concussion (RSC). Study 2 compared mTBI, orthopaedic and uninjured participants on the NWR and the Hopkins Verbal Learning Test (HVLT-R). Main outcomes and results: The NWR did not improve the diagnostic accuracy of the RSC. However, it is reliable and indexes sub-vocal rehearsal speed. These findings provide evidence that although the current form of the NWR lacks sensitivity to the impact of mTBI, the development of a more sensitive test of sub-vocal rehearsal deficits following mTBI is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Case linkage, the linking of crimes into series, is used in policing in the UK and other countries. Previous researchers have proposed using rapists' speech in this practice; however, researching this application requires the development of a reliable coding system for rapists' speech. A system was developed based on linguistic theories of pragmatics which allowed for the categorization of an utterance into a speech act type (e.g. directive). Following this classification, the qualitative properties of the utterances (e.g. the degree of threat it carried) could be captured through the use of rating scales. This system was tested against a previously developed system using 188 rapists' utterances taken from victims' descriptions of rape. The pragmatics-based system demonstrated higher inter-rater reliability whilst enabling the classification of a greater number of rapists' utterances. Inter-rater reliability for the subscales was also tested using a sub-sample of 50 rapists' utterances and inter-item correlations were calculated. Seventy-six per cent of the subscales had satisfactory to high inter-rater reliability. Based on these findings and the inter-item correlations, the classification system was revised. The potential use of this system for the practices of case linkage and offender profiling is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cascaded multilevel inverters-based Static Var Generators (SVGs) are FACTS equipment introduced for active and reactive power flow control. They eliminate the need for zigzag transformers and give a fast response. However, with regard to their application for flicker reduction in using Electric Arc Furnace (EAF), the existing multilevel inverter-based SVGs suffer from the following disadvantages. (1) To control the reactive power, an off-line calculation of Modulation Index (MI) is required to adjust the SVG output voltage. This slows down the transient response to the changes of reactive power; and (2) Random active power exchange may cause unbalance to the voltage of the d.c. link (HBI) capacitor when the reactive power control is done by adjusting the power angle d alone. To resolve these problems, a mathematical model of 11-level cascaded SVG, was developed. A new control strategy involving both MI (modulation index) and power angle (d) is proposed. A selected harmonics elimination method (SHEM) is taken for switching pattern calculations. To shorten the response time and simplify the controls system, feed forward neural networks are used for on-line computation of the switching patterns instead of using look-up tables. The proposed controller updates the MI and switching patterns once each line-cycle according to the sampled reactive power Qs. Meanwhile, the remainder reactive power (compensated by the MI) and the reactive power variations during the line-cycle will be continuously compensated by adjusting the power angles, d. The scheme senses both variables MI and d, and takes action through the inverter switching angle, qi. As a result, the proposed SVG is expected to give a faster and more accurate response than present designs allow. In support of the proposal there is a mathematical model for reactive powered distribution and a sensitivity matrix for voltage regulation assessment, MATLAB simulation results are provided to validate the proposed schemes. The performance with non-linear time varying loads is analysed and refers to a general review of flicker, of methods for measuring flickers due to arc furnace and means for mitigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research was concerned with identifying factors which may influence human reliability within chemical process plants - these factors are referred to as Performance Shaping Factors (PSFs). Following a period of familiarization within the industry, a number of case studies were undertaken covering a range of basic influencing factors. Plant records and site `lost time incident reports' were also used as supporting evidence for identifying and classifying PSFs. In parallel to the investigative research, the available literature appertaining to human reliability assessment and PSFs was considered in relation to the chemical process plan environment. As a direct result of this work, a PSF classification structure has been produced with an accompanying detailed listing. Phase two of the research considered the identification of important individual PSFs for specific situations. Based on the experience and data gained during phase one, it emerged that certain generic features of a task influenced PSF relevance. This led to the establishment of a finite set of generic task groups and response types. Similarly, certain PSFs influence some human errors more than others. The result was a set of error type key words, plus the identification and classification of error causes with their underlying error mechanisms. By linking all these aspects together, a comprehensive methodology has been forwarded as the basis of a computerized aid for system designers. To recapitulate, the major results of this research have been: One, the development of a comprehensive PSF listing specifically for the chemical process industries with a classification structure that facilitates future updates; and two, a model of identifying relevant SPFs and their order of priority. Future requirements are the evaluation of the PSF listing and the identification method. The latter must be considered both in terms of `useability' and its success as a design enhancer, in terms of an observable reduction in important human errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis considers the visual electrophysiological effects of vigabatrin (an anti-epileptic drug, which acts by increasing the levels of the inhibitory neurotransmitter GABA on the retina of the eye compared to the concentric visual field defects which have been found associated with the drug. Flash and pattern ERG's, EOG's multifocal ERG's (VERIS), flash and pattern VEP's and visual fields were tested. Although VEP's have been shown not to be affected by vigabatrin, these were recorded to complete the testing. Initially, of the eight vigabatrin patients with known visual field defects, 7 showed abnormally delayed 30Hz flicker a-wave latencies, 5 abnormally delayed 30Hz b-wave latencies and 6 abnormally low 30Hz amplitudes. Also 7 showed an abnormally prolonged latency of oscillatory potential 1 (OP1). The two patients taking vigabatrin at the time of testing showed low EOG Arden index values. The VERIS results correlated well with the severity of the visual field defects. Following this finding, eleven healthy subjects received vigabatrin over a 10-day period. No changes were seen in the visual fields, however, the photopic ERG b-wave latency significantly increased (although not to abnormal values). A matched pairs study with eleven vigabatrin, patients and eleven epileptic patients, who had never taken vigabatrin supported the findings of abnormal 30Hz flicker b-wave and OP latencies associated with vigabatrin, again with the VERIS results correlating to the severity of the visual field defect. The abnormal 30Hz flicker and VERIS responses indicate involvement of the cone photoreceptors and the OP's show an effect on the amacrine cells. The ERG increase in the photopic b-wave latency also suggests involvement of the bipolar cells, however, this effect and the reversible effect on the Arden index after cessation of the drug may be unrelated to the visual field defect. To conclude this thesis, a field specific VEP stimulus was developed to assess the retinal function in the peripheral field of paediatric patients. It comprises of a dartboard stimulus with a central 0-5 degree black and white chequered stimulus, a blank 5-30 degree annulus and a 30-60 degree peripheral chequered stimulus. When optimised on four vigabatrin patients it was found that no peripheral response can be evoked with a field loss exceeding 30-35 degrees. Co-operation was found to be successful in children as young as four years old.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.