935 resultados para Spontaneous-emission
Resumo:
Articular cartilage has poor reparative capacities, and once damaged cartilage lesions remain chronic and can lead to osteoarthritis. Over the last decade, several innovative therapies have been introduced to promote the regeneration of articular cartilage while sustaining sufficient mechanical stress and permitting a pain free motion. An important measure of outcome is the morphological characterization of the repair tissue in order to allow for cross-study evaluation. The International Cartilage Repair Society has developed a analogue visual scale to quantify repair tissue, which is described in this paper.
Resumo:
OBJECTIVE: Craving for alcohol is probably involved in acquisition and maintenance of alcohol dependence to a substantial degree. However, the brain substrates and mechanisms that underlie alcohol craving await more detailed elucidation. METHOD: Positron emission tomography was used to map regional cerebral blood flow (CBF) in 21 detoxified patients with alcohol dependence during exposure to alcoholic and non-alcoholic beverages. RESULTS: During the alcohol condition compared with the control condition, significantly increased CBF was found in the ventral putamen. Additionally, activated areas included insula, dorsolateral prefrontal cortex and cerebellum. Cerebral blood flow increase in these regions was related to self-reports of craving assessed in the alcoholic patients. CONCLUSIONS: In this investigation, cue-induced alcohol craving was associated with activation of brain regions particularly involved in brain reward mechanisms, memory and attentional processes. These results are consistent with studies on craving for other addictive substances and may offer strategies for more elaborate studies on the neurobiology of addiction.
Resumo:
We analyzed sex differences in 696 patients with spontaneous cervical artery dissection. There were more men (n = 399; p < 0.0001), and men showed a higher frequency of hypertension (31% vs 15%; p < 0.0001). Women were younger (42.5 +/- 9.9 vs 47.5 +/- 9.3 years; p < 0.0001), had more often multiple dissections (18 vs 10%; p = 0.001), migraine (47 vs 20%; p < 0.0001), and tinnitus (16 vs 8%; p = 0.001). Outcome and mortality were similar in both sexes.
Resumo:
We examined the seasonal variability of spontaneous cervical artery dissection (sCAD) by analysing prospectively collected data from 352 patients with 380 sCAD (361 symptomatic sCAD; 305 carotid and 75 vertebral artery dissections) admitted to two university hospitals with a catchment area of 2,200,000 inhabitants between 1985 and 2004. Presenting symptoms and signs of the 380 sCAD were ischaemic stroke in 241 (63%), transient ischaemic attack in 40 (11%), retinal ischemia in seven (2%), and non-ischaemic in 73 (19%) cases; 19 (5%) were asymptomatic sCAD. A seasonal pattern, with higher frequency of sCAD in winter (31.3%; 95% confidence interval (CI): 26.5 to 36.4; p=0.021) compared to spring (25.5%; 95% CI: 21.1 to 30.3), summer (23.5%; 95% CI: 19.3 to 28.3), and autumn (19.7%; 95% CI: 15.7 to 24.1) was observed. Although the cause of seasonality in sCAD is unclear, the winter peaks of infection, hypertension, and aortic dissection suggest common underlying mechanisms.
Resumo:
In this manuscript we are concerned with functional imaging of the colon to assess the kinetics of a microbicide lubricant. The overarching goal is to understand the distribution of the lubricant in the colon. Such information is crucial for understanding the potential impact of the microbicide on HIV viral transmission. The experiment was conducted by imaging a radiolabeled lubricant distributed in the subject’s colon. The tracer imaging was conducted via single photon emission computed tomography (SPECT), a non-invasive, in-vivo functional imaging technique. We develop a novel principal curve algorithm to construct a three dimensional curve through the colon images. The developed algorithm is tested and debugged on several difficult two dimensional images of familiar curves where the original principal curve algorithm does not apply. The final curve fit to the colon data is compared with experimental sigmoidoscope collection.
Resumo:
BACKGROUND: Peri-implantitis is associated with the presence of submarginal plaque, soft-tissue inflammation and advanced breakdown of the supporting bone. The progression of peri-implantitis following varying periods of continuing plaque accumulation has been studied in animal models. OBJECTIVE: The aim of the current experiment was to study the progression of peri-implantitis around implants with different surface roughness. MATERIAL AND METHODS: In five beagle dogs, three implants with either a sandblasted acid-etched surface (SLA) or a polished surface (P) were installed bilaterally in the edentulous premolar regions. After 3 months on a plaque control regimen, experimental peri-implantitis was induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. After this 4-month period, ligatures were removed and plaque accumulation was continued for an additional 5 months. Radiographs of all implant sites were obtained before and after 'active' experimental peri-implantitis as well as at the end of the experiment. Biopsies were harvested and the tissue samples were prepared for light microscopy. The sections were used for histometric and morphometric examinations. RESULTS: The radiographic examinations indicated that similar amounts of bone loss occurred at SLA and P sites during the active breakdown period, while the progression of bone loss was larger at SLA than at polished sites following ligature removal. The histological examination revealed that both bone loss and the size of the inflammatory lesion in the connective tissue were larger in SLA than in polished implant sites. The area of plaque was also larger at implants with an SLA surface than at implants with a polished surface. CONCLUSION: It is suggested that the progression of peri-implantitis, if left untreated, is more pronounced at implants with a moderately rough surface than at implants with a polished surface.