996 resultados para Reversed Hazard Rate
Resumo:
The application of continuous positive airway pressure (CPAP) produces important hemodynamic alterations, which can influence breathing pattern (BP) and heart rate variability (HRV). The aim of this study was to evaluate the effects of different levels of CPAP on postoperative BP and HRV after coronary artery bypass grafting (CABG) surgery and the impact of CABG surgery on these variables. Eighteen patients undergoing CABG were evaluated postoperatively during spontaneous breathing (SB) and application of four levels of CPAP applied in random order: sham (3 cmH2O), 5 cmH2O, 8 cmH2O, and 12 cmH2O. HRV was analyzed in time and frequency domains and by nonlinear methods and BP was analyzed in different variables (breathing frequency, inspiratory tidal volume, inspiratory and expiratory time, total breath time, fractional inspiratory time, percent rib cage inspiratory contribution to tidal volume, phase relation during inspiration, phase relation during expiration). There was significant postoperative impairment in HRV and BP after CABG surgery compared to the preoperative period and improvement of DFAα1, DFAα2 and SD2 indexes, and ventilatory variables during postoperative CPAP application, with a greater effect when 8 and 12 cmH2O were applied. A positive correlation (P < 0.05 and r = 0.64; Spearman) was found between DFAα1 and inspiratory time to the delta of 12 cmH2O and SB of HRV and respiratory values. Acute application of CPAP was able to alter cardiac autonomic nervous system control and BP of patients undergoing CABG surgery and 8 and 12 cmH2O of CPAP provided the best performance of pulmonary and cardiac autonomic functions.
Resumo:
We determined the response characteristics and functional correlates of the dynamic relationship between the rate (Δ) of oxygen consumption ( O2) and the applied power output (work rate = WR) during ramp-incremental exercise in patients with mitochondrial myopathy (MM). Fourteen patients (7 males, age 35.4 ± 10.8 years) with biopsy-proven MM and 10 sedentary controls (6 males, age 29.0 ± 7.8 years) took a ramp-incremental cycle ergometer test for the determination of the
O2 on-exercise mean response time (MRT) and the gas exchange threshold (GET). The Δ
O2/ΔWR slope was calculated up to GET (S1), above GET (S2) and over the entire linear portion of the response (S T). Knee muscle endurance was measured by isokinetic dynamometry. As expected, peak
O2 and muscle performance were lower in patients than controls (P < 0.05). Patients had significantly lower Δ
O2/ΔWR than controls, especially the S2 component (6.8 ± 1.5 vs 10.3 ± 0.6 mL·min-1·W-1, respectively; P < 0.001). There were significant relationships between Δ
O2/ΔWR (S T) and muscle endurance, MRT-
O2, GET and peak
O2 in MM patients (P < 0.05). In fact, all patients with Δ
O2/ΔWR below 8 mL·min-1·W-1 had severely reduced peak
O2 values (<60% predicted). Moreover, patients with higher cardiopulmonary stresses during exercise (e.g., higher Δ ventilation/carbon dioxide output and Δ heart rate/Δ
O2) had lower Δ
O2/ΔWR (P < 0.05). In conclusion, a readily available, effort-independent index of aerobic dysfunction during dynamic exercise (Δ
O2/ΔWR) is typically reduced in patients with MM, being related to increased functional impairment and higher cardiopulmonary stress.
Resumo:
The objectives of this study were to evaluate and compare the use of linear and nonlinear methods for analysis of heart rate variability (HRV) in healthy subjects and in patients after acute myocardial infarction (AMI). Heart rate (HR) was recorded for 15 min in the supine position in 10 patients with AMI taking β-blockers (aged 57 ± 9 years) and in 11 healthy subjects (aged 53 ± 4 years). HRV was analyzed in the time domain (RMSSD and RMSM), the frequency domain using low- and high-frequency bands in normalized units (nu; LFnu and HFnu) and the LF/HF ratio and approximate entropy (ApEn) were determined. There was a correlation (P < 0.05) of RMSSD, RMSM, LFnu, HFnu, and the LF/HF ratio index with the ApEn of the AMI group on the 2nd (r = 0.87, 0.65, 0.72, 0.72, and 0.64) and 7th day (r = 0.88, 0.70, 0.69, 0.69, and 0.87) and of the healthy group (r = 0.63, 0.71, 0.63, 0.63, and 0.74), respectively. The median HRV indexes of the AMI group on the 2nd and 7th day differed from the healthy group (P < 0.05): RMSSD = 10.37, 19.95, 24.81; RMSM = 23.47, 31.96, 43.79; LFnu = 0.79, 0.79, 0.62; HFnu = 0.20, 0.20, 0.37; LF/HF ratio = 3.87, 3.94, 1.65; ApEn = 1.01, 1.24, 1.31, respectively. There was agreement between the methods, suggesting that these have the same power to evaluate autonomic modulation of HR in both AMI patients and healthy subjects. AMI contributed to a reduction in cardiac signal irregularity, higher sympathetic modulation and lower vagal modulation.
Resumo:
The objective was to elucidate the relationships between serum concentrations of the gut hormone peptide YY (PYY) and ghrelin and growth development in infants for potential application to the clinical observation index. Serum concentrations of PYY and ghrelin were measured using radioimmunoassay from samples collected at the clinic. For each patient, gestational age, birth weight, time required to return to birth weight, rate of weight gain, time required to achieve recommended daily intake (RDI) standards, time required for full-gastric feeding, duration of hospitalization, and time of administration of total parenteral nutrition were recorded. Serum PYY and ghrelin concentrations were significantly higher in the preterm group (N = 20) than in the full-term group (N = 20; P < 0.01). Within the preterm infant group, the serum concentrations of PYY and ghrelin on postnatal day (PND) 7 (ghrelin = 1485.38 ± 409.24; PYY = 812.37 ± 153.77 ng/L) were significantly higher than on PND 1 (ghrelin = 956.85 ± 223.09; PYY = 545.27 ± 204.51 ng/L) or PND 3 (ghrelin = 1108.44 ± 351.36; PYY = 628.96 ± 235.63 ng/L; P < 0.01). Both serum PYY and ghrelin concentrations were negatively correlated with body weight, and the degree of correlation varied with age. Serum ghrelin concentration correlated negatively with birth weight and positively with the time required to achieve RDI (P < 0.05). In conclusion, serum PYY and ghrelin concentrations reflect a negative energy balance, predict postnatal growth, and enable compensation. Further studies are required to elucidate the precise concentration and roles of PYY and ghrelin in newborns and to determine the usefulness of measuring these hormones in clinical practice.
Resumo:
This study evaluated the dynamic behavior of total and compartmental chest wall volumes [(V CW) = rib cage (V RC) + abdomen (V AB)] as measured breath-by-breath by optoelectronic plethysmography during constant-load exercise in patients with stable chronic obstructive pulmonary disease. Thirty males (GOLD stages II-III) underwent a cardiopulmonary exercise test to the limit of tolerance (Tlim) at 75% of peak work rate on an electronically braked cycle ergometer. Exercise-induced dynamic hyperinflation was considered to be present when end-expiratory (EE) V CW increased in relation to resting values. There was a noticeable heterogeneity in the patterns of V CW regulation as EEV CW increased non-linearly in 17/30 "hyperinflators" and decreased in 13/30 "non-hyperinflators" (P < 0.05). EEV AB decreased slightly in 8 of the "hyperinflators", thereby reducing and slowing the rate of increase in end-inspiratory (EI) V CW (P < 0.05). In contrast, decreases in EEV CW in the "non-hyperinflators" were due to the combination of stable EEV RC with marked reductions in EEV AB. These patients showed lower EIV CW and end-exercise dyspnea scores but longer Tlim than their counterparts (P < 0.05). Dyspnea increased and Tlim decreased non-linearly with a faster rate of increase in EIV CW regardless of the presence or absence of dynamic hyperinflation (P < 0.001). However, no significant between-group differences were observed in metabolic, pulmonary gas exchange and cardiovascular responses to exercise. Chest wall volumes are continuously regulated during exercise in order to postpone (or even avoid) their migration to higher operating volumes in patients with COPD, a dynamic process that is strongly dependent on the behavior of the abdominal compartment.
Resumo:
Studies on the assessment of heart rate variability threshold (HRVT) during walking are scarce. We determined the reliability and validity of HRVT assessment during the incremental shuttle walk test (ISWT) in healthy subjects. Thirty-one participants aged 57 ± 9 years (17 females) performed 3 ISWTs. During the 1st and 2nd ISWTs, instantaneous heart rate variability was calculated every 30 s and HRVT was measured. Walking velocity at HRVT in these tests (WV-HRVT1 and WV-HRVT2) was registered. During the 3rd ISWT, physiological responses were assessed. The ventilatory equivalents were used to determine ventilatory threshold (VT) and the WV at VT (WV-VT) was recorded. The difference between WV-HRVT1 and WV-HRVT2 was not statistically significant (median and interquartile range = 4.8; 4.8 to 5.4 vs4.8; 4.2 to 5.4 km/h); the correlation between WV-HRVT1 and WV-HRVT2 was significant (r = 0.84); the intraclass correlation coefficient was high (0.92; 0.82 to 0.96), and the agreement was acceptable (-0.08 km/h; -0.92 to 0.87). The difference between WV-VT and WV-HRVT2 was not statistically significant (4.8; 4.8 to 5.4 vs 4.8; 4.2 to 5.4 km/h) and the agreement was acceptable (0.04 km/h; -1.28 to 1.36). HRVT assessment during walking is a reliable measure and permits the estimation of VT in adults. We suggest the use of the ISWT for the assessment of exercise capacity in middle-aged and older adults.
Resumo:
The main purpose of this study was to investigate the level of agreement between the gas exchange threshold (GET) and heart rate variability threshold (HRVT) during maximal cardiopulmonary exercise testing (CPET) using three different exercise modalities. A further aim was to establish whether there was a 1:1 relationship between the percentage heart rate reserve (%HRR) and percentage oxygen uptake reserve (%V˙O2R) at intensities corresponding to GET and HRVT. Sixteen apparently healthy men 17 to 28 years of age performed three maximal CPETs (cycling, walking, and running). Mean heart rate and V˙O2 at GET and HRVT were 16 bpm (P<0.001) and 5.2 mL·kg-1·min-1 (P=0.001) higher in running than cycling, but no significant differences were observed between running and walking, or cycling and walking (P>0.05). There was a strong relationship between GET and HRVT, with R2 ranging from 0.69 to 0.90. A 1:1 relationship between %HRR and %V˙O2R was not observed at GET and HRVT. The %HRR was higher during cycling (GET mean difference=7%; HRVT mean difference=11%; both P<0.001), walking (GET mean difference=13%; HRVT mean difference=13%; both P<0.001), or running (GET mean difference=11%; HRVT mean difference=10%; both P<0.001). Therefore, using HRVT to prescribe aerobic exercise intensity appears to be valid. However, to assume a 1:1 relationship between %HRR and %V˙O2R at HRVT would probably result in overestimation of the energy expenditure during the bout of exercise.
Resumo:
In adults with non-promyelocytic acute myeloid leukemia (AML), high-dose cytarabine consolidation therapy has been shown to influence survival in selected patients, although the appropriate doses and schemes have not been defined. We evaluated survival after calculating the actual dose of cytarabine that patients received for consolidation therapy and divided them into 3 groups according to dose. We conducted a single-center, retrospective study involving 311 non-promyelocytic AML patients with a median age of 36 years (16-79 years) who received curative treatment between 1978 and 2007. The 131 patients who received cytarabine consolidation were assigned to study groups by their cytarabine dose protocol. Group 1 (n=69) received <1.5 g/m2 every 12 h on 3 alternate days for up to 4 cycles. The remaining patients received high-dose cytarabine (≥1.5 g/m2 every 12 h on 3 alternate days for up to 4 cycles). The actual dose received during the entire consolidation period in these patients was calculated, allowing us to divide these patients into 2 additional groups. Group 2 (n=27) received an intermediate-high-dose (<27 g/m2), and group 3 (n=35) received a very-high-dose (≥27 g/m2). Among the 311 patients receiving curative treatment, the 5-year survival rate was 20.2% (63 patients). The cytarabine consolidation dose was an independent determinant of survival in multivariate analysis; age, karyotype, induction protocol, French-American-British classification, and de novo leukemia were not. Comparisons showed that the risk of death was higher in the intermediate-high-dose group 2 (hazard ratio [HR]=4.51; 95% confidence interval [CI]: 1.81-11.21) and the low-dose group 1 (HR=4.43; 95% CI: 1.97-9.96) than in the very-high-dose group 3, with no significant difference between those two groups. Our findings indicated that very-high-dose cytarabine during consolidation in adults with non-promyelocytic AML may improve survival.
Resumo:
In anurans, changes in ambient temperature influence body temperature and, therefore, energy consumption. These changes ultimately affect energy supply and, consequently, heart rate (HR). Typically, anurans living in different thermal environments have different thermal sensitivities, and these cannot be distinguished by changes in HR. We hypothesized that Rhinella jimi (a toad from a xeric environment that lives in a wide range of temperatures) would have a lower thermal sensitivity regarding cardiac control than R. icterica (originally from a tropical forest environment with a more restricted range of ambient temperatures). Thermal sensitivity was assessed by comparing animals housed at 15° and 25°C. Cardiac control was estimated by heart rate variability (HRV) and heart rate complexity (HRC). Differences in HRV between the two temperatures were not significant (P=0.214 for R. icterica and P=0.328 for R. jimi), whereas HRC differences were. All specimens but one R. jimi had a lower HRC at 15°C (all P<0.01). These results indicate that R. jimi has a lower thermal sensitivity and that cardiac control is not completely dependent on the thermal environment because HRC was not consistently different between temperatures in all R. jimi specimens. This result indicates a lack of evolutive trade-offs among temperatures given that heart rate control at 25°C is potentially not a constraint to heart rate control at 15°C.
Resumo:
The objective of this observational, multicenter study was to evaluate the association of body mass index (BMI) with disease severity and prognosis in patients with non-cystic fibrosis bronchiectasis. A total of 339 patients (197 females, 142 males) diagnosed with non-cystic fibrosis bronchiectasis by high-resolution computed tomography were classified into four groups: underweight (BMI<18.5 kg/m2), normal weight (18.5≤BMI<25.0 kg/m2), overweight (25.0≤BMI<30.0 kg/m2), and obese (BMI≥30.0 kg/m2). Clinical variables expressing disease severity were recorded, and acute exacerbations, hospitalizations, and survival rates were estimated during the follow-up period. The mean BMI was 21.90 kg/m2. The underweight group comprised 28.61% of all patients. BMI was negatively correlated with acute exacerbations, C-reactive protein, erythrocyte sedimentation rate, radiographic extent of bronchiectasis, and chronic colonization by P. aeruginosa and positively correlated with pulmonary function indices. BMI was a significant predictor of hospitalization risk independent of relevant covariates. The 1-, 2-, 3-, and 4-year cumulative survival rates were 94%, 86%, 81%, and 73%, respectively. Survival rates decreased with decreasing BMI (χ2=35.16, P<0.001). The arterial carbon dioxide partial pressure, inspiratory capacity, age, BMI, and predicted percentage of forced expiratory volume in 1 s independently predicted survival in the Cox proportional hazard model. In conclusion, an underweight status was highly prevalent among patients with non-cystic fibrosis bronchiectasis. Patients with a lower BMI were prone to developing more acute exacerbations, worse pulmonary function, amplified systemic inflammation, and chronic colonization by P. aeruginosa. BMI was a major determinant of hospitalization and death risks. BMI should be considered in the routine assessment of patients with non-cystic fibrosis bronchiectasis.
Resumo:
The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.
Resumo:
Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.
Resumo:
Diplomityössä tutkitaan virtauksen kääntymistä Lappeenrannan teknillisen yliopiston PWR PACTEL –koelaitteiston pystyhöyrystimen lämmönvaihtoputkissa käyttäen APROS–prosessisimulointiohjelmaa. Työn teoriaosassa esitellään pystyhöyrystimillä varustettuja koelaitteistoja, erityisesti PWR PACTEL ja sen höyrystin. Lisäksi esitellään virtauksen kääntymisestä tehtyjä havaintoja ja käsitellään kääntymistä teoreettisesta näkökulmasta. Simulointiosan alussa esitellään työssä käytetty APROS –prosessisimulointiohjelma, sekä sen avulla höyrystimestä luodut mallit. Työssä on tutkittu virtauksen käännöstapahtumaa simuloimalla useita eri transienttitilanteita pienillä primäärimassavirroilla. Simulaatiotapauksissa havaittiin virtauksen kääntyvän höyrystimen eripituisissa lämmönvaihtoputkissa, tilanteesta riippuen pääosin lyhimmissä tai toisiksi lyhimmissä lämmönvaihtoputkissa. Transienttien eri vaiheiden, ts. primäärimassavirran muutos- ja tasaantumisvaiheiden pituuden havaittiin vaikuttavan siihen, minkä pituisissa putkissa kääntyminen tapahtuu ja missä järjestyksessä.
Resumo:
The objective of this work was to study the influence of temperature on the respiration rate of minimally processed organic carrots (Daucus Carota L. cv. Brasília) with and without the application of a gelatin film. The samples were packed in flexible bags and stored at 1, 5 and 10 °C. During the five days of storage, the CO2 and O2 concentrations in the headspace of the package were monitored by gas chromatography, and the mathematical model based on enzymatic kinetics was used to estimate the respiration rate of minimally processed organic carrots. The effect of temperature on the respiration rate was evaluated by the Arrhenius equation. The results showed that the O2 concentration decreased during the storage period and the CO2 concentration increased. The lowest O2 concentrations of 2.59 and 2.66% were found for the samples stored at 10 °C with and without the film, respectively. For the CO2 concentration, the highest concentrations of 16.25 and 16.32% were again found for the temperature of 10 °C with and without the application of the film, respectively. At the temperature of 1 °C, the maximum respiratory rates for the samples without and with the film were 10.82 and 10.44 mL CO2.kg-1/hour, respectively, after 72 hours of storage. The greatest respiratory rate was obtained at 10 °C, the maximum peak being reached after 50 hours. Activation energy values were of 50.59 kJ.mol-1, for the samples with the film, and 51.88 kJ.mol-1 for the samples without the film.