985 resultados para Reliability index
Resumo:
Invokaatio: In nomine Jesu!
Resumo:
Invokaatio: In nomine Jesu!
Resumo:
The objective of the present study was to evaluate the risk factors associated with the presence of coronary artery calcification (CAC) in patients with type 1 diabetes (T1D). A cross-sectional study was conducted on 100 consecutive T1D patients without coronary artery disease, with at least 5 years of diabetes and absence of end-stage renal disease. Mean age was 38 ± 10 years and 57% were males. CAC score was measured by multidetector computed tomography (Siemens Sensation 64 Cardiac). The insulin resistance index was measured using the estimated glucose disposal rate (eGDR). The eGDR was lower among CAC-positive patients than among CAC-negative patients, suggesting an increased insulin resistance. In a logistic regression model adjusted for age (at 10-year intervals), eGDR, diabetic nephropathy and gender, CAC was associated with age [OR = 2.73 (95%CI = 1.53-4.86), P = 0.001] and with eGDR [OR = 0.08 (95%CI = 0.02-0.21), P = 0.004]. In T1D subjects, insulin resistance is one of the most important risk factors for subclinical atherosclerosis.
Resumo:
The objective of the present study was to explore the factors related to the prognosis of colorectal cancer (CRC) and to establish a prognostic model for the selection of patients who might benefit from hepatic resection for metastatic CRC. A total of 293 patients undergoing liver resection for metastatic CRC (172 males and 80 females ranging in age from 26 to 80 years) were selected and clinical, pathological and outcome data were examined in this retrospective study. The prognostic index (PI) of the patients was calculated on the basis of results of multivariate analysis. Patients were stratified into different groups, with survival curves projected according to PI. The 1-, 3-, and 5-year overall survival rates were 58.3, 26.4, and 11.3%, respectively. Univariate analysis indicated that degree of primary tumor differentiation, resection margin, preoperative carcinoembryonic antigen (CEA) level, number of liver metastases, and resection of liver metastases were associated with prognosis (P < 0.05). In multivariate analysis, the last three factors were found to be independent prognostic factors. The resection of liver metastases was a favorable factor. Patients were classified into three groups according to PI, which differed significantly in survival rate (P < 0.05). The individual survival rate was evaluated based on PI. Resection of hepatic colorectal metastases may produce long-term survival and cure. The proposed PI was easy to use, was highly predictive of patient outcome, and permitted categorization of patients into treatment groups.
Resumo:
The objective of this study was to determine the effect of maternal hydration with oral isotonic solution and water on the amniotic fluid (AF) index of women with normohydramnios. Women with a normal AF index and gestational age between 33 and 36 weeks without maternal complications were randomized into three groups [isotonic solution (Gatorade®), water, control]. The isotonic solution and water groups were instructed to drink 1.5 L of the respective solution and the control group was instructed to drink 200 mL water over a period of 2 to 4 h. AF index was measured before and after hydration by Doppler ultrasonography. The investigator performing the AF index measurement was blind to the subject’s group. Ninety-nine women completed the study without any adverse maternal effects. The median increase in AF index after hydration was significantly greater for the isotonic solution and water groups than for the control group. There was no significant difference between the isotonic solution and water groups. Hydration with isotonic solution and water caused a 10-fold (95%CI: 2.09-49.89) and 6-fold (95%CI: 1.16-30.95) increase in the chance of a 20% increase of AF index, respectively. Maternal hydration with isotonic solution or water increased the AF index in women with normohydramnios.
Severity score system for progressive myelopathy: development and validation of a new clinical scale
Resumo:
Progressive myelopathies can be secondary to inborn errors of metabolism (IEM) such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA) score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM), covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS), the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1)-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001) and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001) were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.
Resumo:
The objective of the present study was to evaluate the predictive values of percent body fat (PBF) and body mass index (BMI) for cardiovascular risk factors, especially when PBF and BMI are conflicting. BMI was calculated by the standard formula and PBF was determined by bioelectrical impedance analysis. A total of 3859 ambulatory adult Han Chinese subjects (2173 males and 1686 females, age range: 18-85 years) without a history of cardiovascular diseases were recruited from February to September 2009. Based on BMI and PBF, they were classified into group 1 (normal BMI and PBF, N = 1961), group 2 (normal BMI, but abnormal PBF, N = 381), group 3 (abnormal BMI, but normal PBF, N = 681), and group 4 (abnormal BMI and PBF, N = 836). When age, gender, lifestyle, and family history of obesity were adjusted, PBF, but not BMI, was correlated with blood glucose and lipid levels. The odds ratio (OR) and 95% confidence interval (CI) for cardiovascular risk factors in groups 2 and 4 were 1.88 (1.45-2.45) and 2.06 (1.26-3.35) times those in group 1, respectively, but remained unchanged in group 3 (OR = 1.32, 95%CI = 0.92-1.89). Logistic regression models also demonstrated that PBF, rather than BMI, was independently associated with cardiovascular risk factors. In conclusion, PBF, and not BMI, is independently associated with cardiovascular risk factors, indicating that PBF is a better predictor.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
In numerous motor tasks, muscles around a joint act coactively to generate opposite torques. A variety of indexes based on electromyography signals have been presented in the literature to quantify muscle coactivation. However, it is not known how to estimate it reliably using such indexes. The goal of this study was to test the reliability of the estimation of muscle coactivation using electromyography. Isometric coactivation was obtained at various muscle activation levels. For this task, any coactivation measurement/index should present the maximal score (100% of coactivation). Two coactivation indexes were applied. In the first, the antagonistic muscle activity (the lower electromyographic signal between two muscles that generate opposite joint torques) is divided by the mean between the agonistic and antagonistic muscle activations. In the second, the ratio between antagonistic and agonistic muscle activation is calculated. Moreover, we computed these indexes considering different electromyographic amplitude normalization procedures. It was found that the first algorithm, with all signals normalized by their respective maximal voluntary coactivation, generates the index closest to the true value (100%), reaching 92 ± 6%. In contrast, the coactivation index value was 82 ± 12% when the second algorithm was applied and the electromyographic signal was not normalized (P < 0.04). The new finding of the present study is that muscle coactivation is more reliably estimated if the EMG signals are normalized by their respective maximal voluntary contraction obtained during maximal coactivation prior to dividing the antagonistic muscle activity by the mean between the agonistic and antagonistic muscle activations.
Resumo:
Polymorphisms of the p53 gene, which participates in DNA repair, can affect the functioning of the p53 protein. The Arg and Pro variants in p53 codon 72 were shown to have different regulation properties of p53-dependent DNA repair target genes that can affect various levels of cytogenetic aberrations in chronic hepatitis B patients. The present study aimed to examine the frequency of chromosomal aberrations and the mitotic index in patients with chronic hepatitis B and their possible association with p53 gene exon 4 codon 72 Arg72Pro (Ex4+119 G>C; rs1042522) polymorphism. Fifty-eight patients with chronic hepatitis B and 30 healthy individuals were genotyped in terms of the p53 gene codon 72 Arg72Pro polymorphism by PCR-RFLP. A 72-h cell culture was performed on the same individuals and evaluated in terms of chromosomal aberrations and mitotic index. A high frequency of chromosomal aberrations and low mitotic index were detected in the patient group compared to the control group. A higher frequency of chromosomal aberrations was detected in both the patient and the control groups with a homozygous proline genotype (13 patients, 3 control subjects) compared to patients and controls with other genotypes [Arg/Pro (38 patients, 20 control subjects) and Arg/Arg (7 patients, 7 control subjects)]. We observed an increased frequency of cytogenetic aberrations in patients with chronic hepatitis B. In addition, a higher frequency of cytogenetic aberrations was observed in p53 variants having the homozygous proline genotype compared to variants having other genotypes both in patients and healthy individuals.
Resumo:
Studies on the assessment of heart rate variability threshold (HRVT) during walking are scarce. We determined the reliability and validity of HRVT assessment during the incremental shuttle walk test (ISWT) in healthy subjects. Thirty-one participants aged 57 ± 9 years (17 females) performed 3 ISWTs. During the 1st and 2nd ISWTs, instantaneous heart rate variability was calculated every 30 s and HRVT was measured. Walking velocity at HRVT in these tests (WV-HRVT1 and WV-HRVT2) was registered. During the 3rd ISWT, physiological responses were assessed. The ventilatory equivalents were used to determine ventilatory threshold (VT) and the WV at VT (WV-VT) was recorded. The difference between WV-HRVT1 and WV-HRVT2 was not statistically significant (median and interquartile range = 4.8; 4.8 to 5.4 vs4.8; 4.2 to 5.4 km/h); the correlation between WV-HRVT1 and WV-HRVT2 was significant (r = 0.84); the intraclass correlation coefficient was high (0.92; 0.82 to 0.96), and the agreement was acceptable (-0.08 km/h; -0.92 to 0.87). The difference between WV-VT and WV-HRVT2 was not statistically significant (4.8; 4.8 to 5.4 vs 4.8; 4.2 to 5.4 km/h) and the agreement was acceptable (0.04 km/h; -1.28 to 1.36). HRVT assessment during walking is a reliable measure and permits the estimation of VT in adults. We suggest the use of the ISWT for the assessment of exercise capacity in middle-aged and older adults.
Resumo:
The objective of this observational, multicenter study was to evaluate the association of body mass index (BMI) with disease severity and prognosis in patients with non-cystic fibrosis bronchiectasis. A total of 339 patients (197 females, 142 males) diagnosed with non-cystic fibrosis bronchiectasis by high-resolution computed tomography were classified into four groups: underweight (BMI<18.5 kg/m2), normal weight (18.5≤BMI<25.0 kg/m2), overweight (25.0≤BMI<30.0 kg/m2), and obese (BMI≥30.0 kg/m2). Clinical variables expressing disease severity were recorded, and acute exacerbations, hospitalizations, and survival rates were estimated during the follow-up period. The mean BMI was 21.90 kg/m2. The underweight group comprised 28.61% of all patients. BMI was negatively correlated with acute exacerbations, C-reactive protein, erythrocyte sedimentation rate, radiographic extent of bronchiectasis, and chronic colonization by P. aeruginosa and positively correlated with pulmonary function indices. BMI was a significant predictor of hospitalization risk independent of relevant covariates. The 1-, 2-, 3-, and 4-year cumulative survival rates were 94%, 86%, 81%, and 73%, respectively. Survival rates decreased with decreasing BMI (χ2=35.16, P<0.001). The arterial carbon dioxide partial pressure, inspiratory capacity, age, BMI, and predicted percentage of forced expiratory volume in 1 s independently predicted survival in the Cox proportional hazard model. In conclusion, an underweight status was highly prevalent among patients with non-cystic fibrosis bronchiectasis. Patients with a lower BMI were prone to developing more acute exacerbations, worse pulmonary function, amplified systemic inflammation, and chronic colonization by P. aeruginosa. BMI was a major determinant of hospitalization and death risks. BMI should be considered in the routine assessment of patients with non-cystic fibrosis bronchiectasis.
Electromagnetic and thermal design of a multilevel converter with high power density and reliability
Resumo:
Electric energy demand has been growing constantly as the global population increases. To avoid electric energy shortage, renewable energy sources and energy conservation are emphasized all over the world. The role of power electronics in energy saving and development of renewable energy systems is significant. Power electronics is applied in wind, solar, fuel cell, and micro turbine energy systems for the energy conversion and control. The use of power electronics introduces an energy saving potential in such applications as motors, lighting, home appliances, and consumer electronics. Despite the advantages of power converters, their penetration into the market requires that they have a set of characteristics such as high reliability and power density, cost effectiveness, and low weight, which are dictated by the emerging applications. In association with the increasing requirements, the design of the power converter is becoming more complicated, and thus, a multidisciplinary approach to the modelling of the converter is required. In this doctoral dissertation, methods and models are developed for the design of a multilevel power converter and the analysis of the related electromagnetic, thermal, and reliability issues. The focus is on the design of the main circuit. The electromagnetic model of the laminated busbar system and the IGBT modules is established with the aim of minimizing the stray inductance of the commutation loops that degrade the converter power capability. The circular busbar system is proposed to achieve equal current sharing among parallel-connected devices and implemented in the non-destructive test set-up. In addition to the electromagnetic model, a thermal model of the laminated busbar system is developed based on a lumped parameter thermal model. The temperature and temperature-dependent power losses of the busbars are estimated by the proposed algorithm. The Joule losses produced by non-sinusoidal currents flowing through the busbars in the converter are estimated taking into account the skin and proximity effects, which have a strong influence on the AC resistance of the busbars. The lifetime estimation algorithm was implemented to investigate the influence of the cooling solution on the reliability of the IGBT modules. As efficient cooling solutions have a low thermal inertia, they cause excessive temperature cycling of the IGBTs. Thus, a reliability analysis is required when selecting the cooling solutions for a particular application. The control of the cooling solution based on the use of a heat flux sensor is proposed to reduce the amplitude of the temperature cycles. The developed methods and models are verified experimentally by a laboratory prototype.
Resumo:
Volatility has a central role in various theoretical and practical applications in financial markets. These include the applications related to portfolio theory, derivatives pricing and financial risk management. Both theoretical and practical applications require good estimates and forecasts for the asset return volatility. The goal of this study is to examine the forecast performance of one of the more recent volatility measures, model-free implied volatility. Model-free implied volatility is extracted from the prices in the option markets, and it aims to provide an unbiased estimate for the market’s expectation on the future level of volatility. Since it is extracted from the option prices, model-free implied volatility should contain all the relevant information that the market participants have. Moreover, model-free implied volatility requires less restrictive assumptions than the commonly used Black-Scholes implied volatility, which means that it should be less biased estimate for the market’s expectations. Therefore, it should also be a better forecast for the future volatility. The forecast performance of model-free implied volatility is evaluated by comparing it to the forecast performance of Black-Scholes implied volatility and GARCH(1,1) forecast. Weekly forecasts for six years period were calculated for the forecasted variable, German stock market index DAX. The data consisted of price observations for DAX index options. The forecast performance was measured using econometric methods, which aimed to capture the biasedness, accuracy and the information content of the forecasts. The results of the study suggest that the forecast performance of model-free implied volatility is superior to forecast performance of GARCH(1,1) forecast. However, the results also suggest that the forecast performance of model-free implied volatility is not as good as the forecast performance of Black-Scholes implied volatility, which is against the hypotheses based on theory. The results of this study are consistent with the majority of prior research on the subject.