914 resultados para Reagent Kits
Resumo:
The biosphere emits copiously volatile organic compounds (VOCs) into the atmosphere, which are removed again depending on the oxidative capacity of the atmosphere and physical processes such as mixing, transport and deposition. Biogenic VOCs react with the primary oxidant of the atmosphere, the hydroxyl radical (OH), and potentially lead to the formation tropospheric ozone and aerosol, which impact regional climate and air quality. The rate of OH decay in the atmosphere, the total OH reactivity is a function of the atmospheric, reactive compound's concentration and reaction velocity with OH. One way to measure the total OH reactivity, the total OH sink, is with the Comparative Reactivity Method - CRM. Basically, the reaction of OH with a reagent (here pyrrole) in clean air and in the presence of atmospheric, reactive molecules is compared. This thesis presents measurements of the total OH reactivity at the biosphere-atmosphere interface to analyze various influences and driving forces. For measurements in natural environment the instrument was automated and a direct, undisturbed sampling method developed. Additionally, an alternative detection system was tested and compared to the originally used detector (Proton Transfer Reaction-Mass Spectrometer, PTR-MS). The GC-PID (Gas Chromatographic Photo-Ionization Detector) was found as a smaller, less expensive, and robust alternative for total OH reactivity measurements. The HUMPPA-COPEC 2010 measurement campaign in the Finish forest was impacted by normal boreal forest emissions as well as prolonged heat and biomass burning emissions. The measurement of total OH reactivity was compared with a comprehensive set of monitored individual species ambient concentration levels. A significant discrepancy between those individually measured OH sinks and the total OH reactivity was observed, which was characterized in detail by the comparison of within and above the forest canopy detected OH reactivity. Direct impact of biogenic emissions on total OH reactivity was examined on Kleiner Feldberg, Germany, 2011. Trans-seasonal measurements of an enclosed Norway spruce branch were conducted via PTR-MS, for individual compound's emission rates, and CRM, for total OH reactivity emission fluxes. Especially during summertime, the individually monitored OH sink terms could not account for the measured total OH reactivity. A controlled oxidation experiment in a low NOx environment was conducted in the EUPHORE reaction chamber (CHEERS, Spain 2011). The concentration levels of the reactant isoprene and its major products were monitored and compared to total OH reactivity measurements as well as to the results of two models. The individually measured compounds could account for the total OH reactivity during this experiment as well as the traditional model-degradation scheme for isoprene (MCM 3.2). Due to previous observations of high OH levels in the isoprene-rich environment of the tropics, a novel isoprene mechanism was recently suggested. In this mechanism (MIME v4) additional OH is generated during isoprene oxidation, which could not be verified in the conditions of the CHEERS experiment.
Resumo:
Der Fokus dieser Arbeit lag auf der Darstellung modifizierter Doxorubicin-Moleküle, um die mit der therapeutischen Anwendung verbundenen Hindernisse wie DNA-Bindungsaffinität, Tumorselektivität, Zell- sowie Nukleusakkumulation, Arzneistoffaufnahme und -resistenz zu überwinden. Für die Bewältigung dieser Limitierungen wurde das Anthrazyklin mit einem weiteren Arzneistoffmolekül sowie verschiedenen Peptiden und Proteinen funktionalisiert. Hierbei wurde zur Modifikation das aliphatische Keton des Arzneistoffs, unter Ausbildung von hydrolysestabilen Oximen, als Hauptstrukturelement verwendet. Wie Raymond B. Weiss bereits vor mehr als 20 Jahren erkannt hat, ist die Suche nach Anthrazyklinen mit besseren pharmakologischen Eigenschaften als die des Doxorubicin ein äußerst schwieriges Unterfangen. Die in dieser Arbeit dargestellten Doxorubicinderivate haben diverse Ansätze verfolgt, um dem „perfekten“ Anthrazyklin ein Stück näher zu kommen. Auch wenn dieses Ziel mit den bisher untersuchten Arzneistoffabkömmlingen noch nicht vollständig erreicht werden konnte, haben derartige Verbindungen ein außerordentlich großes Potential das sogenannte „bessere Doxorubicin“ in naher Zukunft ausfindig zu machen.
Resumo:
Addressing current limitations of state-of-the-art instrumentation in aerosol research, the aim of this work was to explore and assess the applicability of a novel soft ionization technique, namely flowing atmospheric-pressure afterglow (FAPA), for the mass spectrometric analysis of airborne particulate organic matter. Among other soft ionization methods, the FAPA ionization technique was developed in the last decade during the advent of ambient desorption/ionization mass spectrometry (ADI–MS). Based on a helium glow discharge plasma at atmospheric-pressure, excited helium species and primary reagent ions are generated which exit the discharge region through a capillary electrode, forming the so-called afterglow region where desorption and ionization of the analytes occurs. Commonly, fragmentation of the analytes during ionization is reported to occur only to a minimum extent, predominantly resulting in the formation of quasimolecular ions, i.e. [M+H]+ and [M–H]– in the positive and the negative ion mode, respectively. Thus, identification and detection of signals and their corresponding compounds is facilitated in the acquired mass spectra. The focus of the first part of this study lies on the application, characterization and assessment of FAPA–MS in the offline mode, i.e. desorption and ionization of the analytes from surfaces. Experiments in both positive and negative ion mode revealed ionization patterns for a variety of compound classes comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides, and alkaloids. Besides the always emphasized detection of quasimolecular ions, a broad range of signals for adducts and losses was found. Additionally, the capabilities and limitations of the technique were studied in three proof-of-principle applications. In general, the method showed to be best suited for polar analytes with high volatilities and low molecular weights, ideally containing nitrogen- and/or oxygen functionalities. However, for compounds with low vapor pressures, containing long carbon chains and/or high molecular weights, desorption and ionization is in direct competition with oxidation of the analytes, leading to the formation of adducts and oxidation products which impede a clear signal assignment in the acquired mass spectra. Nonetheless, FAPA–MS showed to be capable of detecting and identifying common limonene oxidation products in secondary OA (SOA) particles on a filter sample and, thus, is considered a suitable method for offline analysis of OA particles. In the second as well as the subsequent parts, FAPA–MS was applied online, i.e. for real time analysis of OA particles suspended in air. Therefore, the acronym AeroFAPA–MS (i.e. Aerosol FAPA–MS) was chosen to refer to this method. After optimization and characterization, the method was used to measure a range of model compounds and to evaluate typical ionization patterns in the positive and the negative ion mode. In addition, results from laboratory studies as well as from a field campaign in Central Europe (F–BEACh 2014) are presented and discussed. During the F–BEACh campaign AeroFAPA–MS was used in combination with complementary MS techniques, giving a comprehensive characterization of the sampled OA particles. For example, several common SOA marker compounds were identified in real time by MSn experiments, indicating that photochemically aged SOA particles were present during the campaign period. Moreover, AeroFAPA–MS was capable of detecting highly oxidized sulfur-containing compounds in the particle phase, presenting the first real-time measurements of this compound class. Further comparisons with data from other aerosol and gas-phase measurements suggest that both particulate sulfate as well as highly oxidized peroxyradicals in the gas phase might play a role during formation of these species. Besides applying AeroFAPA–MS for the analysis of aerosol particles, desorption processes of particles in the afterglow region were investigated in order to gain a more detailed understanding of the method. While during the previous measurements aerosol particles were pre-evaporated prior to AeroFAPA–MS analysis, in this part no external heat source was applied. Particle size distribution measurements before and after the AeroFAPA source revealed that only an interfacial layer of OA particles is desorbed and, thus, chemically characterized. For particles with initial diameters of 112 nm, desorption radii of 2.5–36.6 nm were found at discharge currents of 15–55 mA from these measurements. In addition, the method was applied for the analysis of laboratory-generated core-shell particles in a proof-of-principle study. As expected, predominantly compounds residing in the shell of the particles were desorbed and ionized with increasing probing depths, suggesting that AeroFAPA–MS might represent a promising technique for depth profiling of OA particles in future studies.
Resumo:
Due to the limited availability of natural oil and the harmful effects of its usage, the industry has focused in searching for sustainable types of raw materials for the production of chemicals. The bioethanol, obtained by fermentation of biomass, has gained particular importance in recent years both as a biofuel, and as a “building block” molecule because it can be considered as a starting reagent to obtain other added value chemical compounds, such as ethylene, acetaldehyde, butadiene and ethyl acetate. The goal of this research was the study of the interaction of ethanol with catalysts based on TiO2-CeOX. Since the electronic properties have implications on the catalytic activity, the idea was to understand if the TiO2-CeOX systems have different reactivity from that of ceria and rutile alone, or an intermediate between them. The study was focused on the characterization of the adsorbed species on the catalysts surface after ethanol adsorption through an in-situ spectroscopic technique (DRIFTS) that allowed us to extract information that could be helpful for the understanding of the processes at the molecular level. The mass spectrometry was used to monitor on-line the desorbed products. Furthermore, reactivity tests in a flow reactor were performed, in order to verify the catalytic behavior of the samples in conditions which are more similar to those applied at an industrial scale. The samples showed to behave in different way depending on the conditions used and the thermal treatment. The particular behavior of the mixed samples with respect to the single oxides is interpreted for each case according to the spectroscopic information collected.
Resumo:
OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.
Resumo:
Introduction: The aim of the present work was to verify whether calculating a ratio between clotting times obtained with the sensitive PTT-LA and a less sensitive activated partial thromboplastin time (aPTT)-reagent may represent a valuable aPTT-based screening strategy for lupus anticoagulants (LA). Methods: For the pilot study, plasma samples from normal subjects (n = 15) and from patients with LA (n = 10), therapeutic anticoagulation with vitamin K-antagonists (VKA) (n = 15) or unfractionated heparin (n = 15), coagulation factors deficiency (n = 16), and inhibitory antibodies against factor VIII or IX (n = 11) were studied. For the evaluation study, 1553 consecutive plasma samples from nonanticoagulated patients investigated for LA between January 2005 and December 2007 at our institution were studied. Following screening strategies were employed: Pathromtin-SL (aPTT-SL), PTT-LA (aPTT-LA), ratio aPTT-LA/aPTT-SL (aPTT-ratio), and Russell's viper venom (RVV) based LA-Check. LA positive samples were identified by mixing studies and diluted RVV confirmation test (LA-Check/LA-Sure). Results: Pilot study: All screening strategies had a 100% sensitivity, and the aPTT-ratio reached the highest specificity (82%; 95%CI: 74-90%). Within the evaluation study, following sensitivities for LA screening were observed: aPTT-SL 59.0% (95%CI: 57-61%), aPTT-LA 82.1% (95%CI: 80-84%), aPTT-ratio 92.3% (95%CI: 91-94), and LA-Check 83.3% (95%CI: 82-85%). Conclusion: Calculating a ratio between the LA-sensitive PTT-LA and the less sensitive Pathromtin-SL improves the performance of the PTT-LA itself and represents a simple and sensitive aPTT-based integrated strategy for LA screening.
Resumo:
In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.
Resumo:
NK cells express toll-like receptors (TLR) that recognize conserved pathogen or damage associated molecular patterns and play a fundamental role in innate immunity. Low molecular weight dextran sulfate (DXS), known to inhibit the complement system, has recently been reported by us to inhibit TLR4-induced maturation of human monocyte-derived dendritic cells (MoDC). In this study, we investigated the capability of DXS to interfere with human NK cell activation triggered directly by TLR2 agonists or indirectly by supernatants of TLR4-activated MoDC. Both TLR2 agonists and supernatants of TLR4-activated MoDC activated NK cells phenotypically, as demonstrated by the analysis of NK cell activation markers (CD56, CD25, CD69, NKp30, NKp44, NKp46, DNAM-1 and NKG2D), and functionally as shown by increased NK cell degranulation (CD107a surface expression) and IFN-gamma secretion. DXS prevented the up-regulation of NK cell activation markers triggered by TLR2 ligands or supernatants of TLR4-activated MoDC and dose-dependently abrogated NK cell degranulation and IFN-gamma secretion. In summary our results suggest that DXS may be a useful reagent to inhibit the direct and indirect TLR-mediated activation of NK cells.
Resumo:
Over the last decade, translational science has come into the focus of academic medicine, and significant intellectual and financial efforts have been made to initiate a multitude of bench-to-bedside projects. The quest for suitable biomarkers that will significantly change clinical practice has become one of the biggest challenges in translational medicine. Quantitative measurement of proteins is a critical step in biomarker discovery. Assessing a large number of potential protein biomarkers in a statistically significant number of samples and controls still constitutes a major technical hurdle. Multiplexed analysis offers significant advantages regarding time, reagent cost, sample requirements and the amount of data that can be generated. The two contemporary approaches in multiplexed and quantitative biomarker validation, antibody-based immunoassays and MS-based multiple (or selected) reaction monitoring, are based on different assay principles and instrument requirements. Both approaches have their own advantages and disadvantages and therefore have complementary roles in the multi-staged biomarker verification and validation process. In this review, we discuss quantitative immunoassay and multiple reaction monitoring/selected reaction monitoring assay principles and development. We also discuss choosing an appropriate platform, judging the performance of assays, obtaining reliable, quantitative results for translational research and clinical applications in the biomarker field.
Resumo:
Creatinine levels in blood serum are typically used to assess renal function. Clinical determination of creatinine is often based on the Jaffe reaction, in which creatinine in the serum reacts with sodium picrate, resulting in a spectrophotometrically quantifiable product. Previous work from our lab has introduced an electrophoretically mediated initiation of this reaction, in which nanoliter plugs of individual reagent solutions can be added to the capillary and then mixed and reacted. Following electrophoretic separation of the product from excess reactant(s), the product can be directly determined on column. This work aims to gain a detailed understanding of the in-capillary reagent mixing dynamics, in-line reaction yield, and product degradation during electrophoresis, with an overall goal of improving assay sensitivity. One set of experiments focuses on maximizing product formation through manipulation of various conditions such as pH, voltage applied, and timing of the applied voltage, in addition to manipulations in the identity, concentration, and pH of the background electrolyte. Through this work, it was determined that dramatic changes in local voltage fields within the various reagent zones lead to ineffective reagent overlapping. Use of the software simulation program Simul 5 enabled visualization of the reaction dynamics within the capillary, specifically the wide variance between the electric field intensities within the creatinine and picrate zones. Because of this simulation work, the experimental method was modified to increase the ionic strength of the creatinine reagent zone to lower the local voltage field, thus producing more predictable and effective overlap conditions for the reagents and allowing the formation of more Jaffe product. As second set of experiments focuses on controlling the post-reaction product degradation. In that vein, we have systematically explored the importance of the identity, concentration, and pH of the background electrolyte on the post-reaction degradation rate of the product. Although prior work with borate background electrolytes indicated that product degradation was probably a function of the ionic strength of the background electrolyte, this work with a glycine background electrolyte demonstrates that degradation is in fact not a function of ionic strength of the background electrolyte. As the concentration and pH of the glycine background increased, the rate of degradation of product did not change dramatically, whereas in borate-buffered systems, the rate of Jaffe product degradation increased linearly with background electrolyte concentration above 100.0 mM borate. Similarly, increasing pH of the glycine background electrolyte did not result in a corresponding increase in product degradation, as it had with the borate background electrolyte. Other general trends that were observed include: increasing background electrolyte concentration increases peak efficiency and higher pH favors product formation; thus, it appears that use of a background electrolyte other than borate, such as glycine, the rate of degradation of the Jaffe product can be slowed, increasing the sensitivity of this in-line assay.
Resumo:
Chlamydophila (C.) abortus is the most common infectious abortigenic agent in small domestic ruminants in Switzerland. In contrast, the knowledge about chlamydiae in wild ruminants is scarce. As interactions between livestock and Alpine ibex (Capra i. ibex) occur on alpine pastures, the question raises if wild ruminants could play a role as carriers of chlamydiae. Thus, we investigated the prevalence of chlamydiae in Alpine ibex in Switzerland. In total, 624 sera, 676 eye swabs, 84 organ samples and 51 faecal samples from 664 ibex were investigated. Serum samples were tested by two commercial ELISA kits specific for C. abortus. Eye swabs, organs and faecal samples were examined by a Chlamydiaceae-specific real-time polymerase chain reaction (PCR). Positive cases were further investigated by the ArrayTube (AT) microarray method for chlamydial species determination. Of 624 serum samples investigated, 612 animals were negative, whereas nine sera (1.5%) reacted positively in one of the two tests and three sera showed an inconclusive result. Eye swabs of seven out of 412 ibex (1.7%) were tested positive for Chlamydiaceae by real-time PCR. By AT microarray, Chlamydophila (C.) pecorum was identified in two animals, Chlamydophila (C.) pneumoniae was detected in one animal and a mixed infection with C. abortus and C. pecorum was found in four animals. Organs and faecal samples were all negative by real-time PCR analysis. In summary, we conclude that C. abortus is not a common infectious agent in the Swiss ibex population. To our knowledge, this is the first description of C. pneumoniae in ibex. Further studies are necessary to elucidate the situation in other species of wild ruminants as chamois (Rupicapra r. rupicapra), red deer (Cervus elaphus) and roe deer (Capreolus c. capreolus) in Switzerland.
Resumo:
Because interactions between livestock and chamois occur on Alpine pastures, transmission of infectious diseases is considered possible. Thus, the occurrence of Chlamydiaceae, Mycoplasma conjunctivae, and pestiviruses in Alpine chamois (Rupicapra r. rupicapra) of the Surselva region (eastern Swiss Alps) was investigated. In total, 71 sera, 158 eye swabs, 135 tissue samples, and 23 fecal samples from 85 chamois were analyzed. The sera were tested by 2 enzyme-linked immunosorbent assay (ELISA) kits specific for Chlamydophila abortus. Eye swabs, tissue, and fecal samples were examined by a Chlamydiaceae-specific real-time polymerase chain reaction (PCR). Positive cases were further investigated by microarray method. One serum sample (1.4%) was positive in 1 of the ELISAs. Eye swabs of 3 chamois (3.8%) were positive for Chlamydiaceae. The microarray method revealed the presence of Chlamydophila abortus, C pecorum, and C pneumoniae. All tissue and fecal samples were negative. With real-time PCR, 3.9% of the chamois tested positive for Mycoplasma conjunctivae. One chamois had a simultaneous infection with Al. conjunctivae and 2 chlamydial species (C abortus, C. pecorum). Skin and tongue tissue samples of 35 chamois were negative for pestivirus antigen by immunohistochemistry. It was concluded that in contrast to the findings in Pyrenean chamois (Capra p. pyrenaica) of Spain, the occurrence of Chlamydiaceae in Alpine chamois of the Surselva region is low, and the transmission between domestic and wild Caprinae seems not to be frequent. Comparably, persistent pestiviral infections do not seem to be common in chamois of the Surselva region.
Resumo:
In this work electrophoretically mediated micro-analysis (EMMA) is used in conjunction with short end injection to improve the in-capillary Jaffé assay for creatinine. Key advances over prior work include (i) using simulation to ensure intimate overlap of reagent plugs, (ii) using OH- to drive the reaction, (iii) using short-end injection to minimize analysis time and in-line product degradation. The potential-driven overlapping time with the EMMA approach, as well as the borate buffer background electrolyte (BGE) concentration and pH are optimized with the short end approach. The best conditions for short-end analyses would not have been predicted by the prior long end work, owing to a complex interplay of separation time and product degradation rates. Raw peak areas and flow-adjusted peak areas for the Jaffé reaction product (at 505 nm) are used to assess the sensitivity of the short-end EMMA approach. Optimal overlap conditions depend heavily on local conductivity differences within the reagent zone(s), as these differences cause dramatic voltage field differences, which effect reagent overlap dynamics. Simul 5.0, a dynamic simulation program for capillary electrophoresis (CE) systems, is used to understand the ionic boundaries and profiles that give rise to the experimentally obtained data for EMMA analysis. Overall, fast migration of hydroxide ions from the picrate zone makes difficult reagent overlap. In addition, the challenges associated with the simultaneous overlapping of three reagent zones are considered, and experimental results validate the predictions made by the simulation. With one set of “optimized” conditions including OH- (253 mM) as the third reagent zone the response was linear with creatinine concentration (R2 = 0.998) and reproducible over the clinically relevant range (0.08 to 0.1 mM) of standard creatinine concentrations. An LOD (S/N = 3) of 0.02 mM and LOQ (S/N=10) of 0.08 mM were determined. A significant improvement (43%) in assay sensitivity was obtained compared to prior work that considered only two reagents in the overlap.
Resumo:
During sepsis, liver dysfunction is common, and failure of mitochondria to effectively couple oxygen consumption with energy production has been described. In addition to sepsis, pharmacological agents used to treat septic patients may contribute to mitochondrial dysfunction. This study addressed the hypothesis that remifentanil interacts with hepatic mitochondrial oxygen consumption. The human hepatoma cell line HepG2 and their isolated mitochondria were exposed to remifentanil, with or without further exposure to tumor necrosis factor-α (TNF-α). Mitochondrial oxygen consumption was measured by high-resolution respirometry, Caspase-3 protein levels by Western blotting, and cytokine levels by ELISA. Inhibitory κBα (IκBα) phosphorylation, measurement of the cellular ATP content and mitochondrial membrane potential in intact cells were analysed using commercial ELISA kits. Maximal cellular respiration increased after one hour of incubation with remifentanil, and phosphorylation of IκBα occurred, denoting stimulation of nuclear factor κB (NF-κB). The effect on cellular respiration was not present at 2, 4, 8 or 16 hours of incubation. Remifentanil increased the isolated mitochondrial respiratory control ratio of complex-I-dependent respiration without interfering with maximal respiration. Preincubation with the opioid receptor antagonist naloxone prevented a remifentanil-induced increase in cellular respiration. Remifentanil at 10× higher concentrations than therapeutic reduced mitochondrial membrane potential and ATP content without uncoupling oxygen consumption and basal respiration levels. TNF-α exposure reduced respiration of complex-I, -II and -IV, an effect which was prevented by prior remifentanil incubation. Furthermore, prior remifentanil incubation prevented TNF-α-induced IL-6 release of HepG2 cells, and attenuated fragmentation of pro-caspase-3 into cleaved active caspase 3 (an early marker of apoptosis). Our data suggest that remifentanil increases cellular respiration of human hepatocytes and prevents TNF-α-induced mitochondrial dysfunction. The results were not explained by uncoupling of mitochondrial respiration.