941 resultados para Radio equipment.


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two studies were conducted to determine how well story grammar predicted recall of televised stories. In Experiment 1, preschoolers viewed a non-narrated televised story from "Sesame Street." In Experiment 2, preschoolers and adults were administered a narrative via television or radio. In both studies, subjects' retention reflected recall of nodal information, regardless of medium of input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the novel notion of offering a radio access network as a service. Its components may be instantiated on general purpose platforms with pooled resources (both radio and hardware ones) dimensioned on-demand, elastically and following the pay-per-use principle. A novel architecture is proposed that supports this concept. The architecture's success is in its modularity, well-defined functional elements and clean separation between operational and control functions. By moving much processing traditionally located in hardware for computation in the cloud, it allows the optimisation of hardware utilization and reduction of deployment and operation costs. It enables operators to upgrade their network as well as quickly deploy and adapt resources to demand. Also, new players may easily enter the market, permitting a virtual network operator to provide connectivity to its users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ende Mai 2014 wählt Europa ein neues Parlament. Klaus Armingeon kann mitwählen. Der Direktor des Instituts für Politikwissenschaft an der Universität Bern ist Schweizer, Deutscher und EU-Bürger und heute Gast von Susanne Brunner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The new ATS/ERS consensus report recommends in vitro validation of multiple-breath inert gas washout (MBW) equipment based on a lung model with simulated physiologic conditions. We aimed to assess accuracy of two MBW setups for infants and young children using this model, and to compare functional residual capacity (FRC) from helium MBW (FRCMBW ) with FRC from plethysmography (FRCpleth ) in vivo. METHODS The MBW setups were based on ultrasonic flow meter technology. Sulfur hexafluoride and helium were used as tracer gases. We measured FRC in vitro for specific model settings with and without carbon dioxide and calculated differences of measured to generated FRC. For in vivo evaluation, difference between FRCMBW and FRCpleth was calculated in 20 healthy children, median age 6.1 years. Coefficient of variation (CV) was calculated per FRC. RESULTS In the infant model (51 runs, FRC 80-300 ml), mean (SD) relative difference between generated and measured FRCs was 0.7 (4.7) %, median CV was 4.4% for measured FRCs. In the young child model, one setting (8 runs, FRC 400 ml) showed a relative difference of up to 13%. For the remaining FRCs (42 runs, FRC 600-1,400 ml), mean (SD) relative difference was -2.0 (3.4) %; median CV was 1.4% for measured FRCs. In vivo FRCpleth exceeded FRCMBW values by 37% on average. CONCLUSIONS Both setups measure lung volumes in the intended age group reliably and reproducibly. Characteristics of different techniques should be considered when measuring lung volumes in vivo. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.