907 resultados para Portable device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explored the potential of a carbon nanotube (CNT) coating working in conjunction with a recently developed localized surface plasmon (LSP) device (based upon a nanostructured thin film consisting of of nano-wires of platinum) with ultra-high sensitivity to changes in the surrounding index. The uncoated LSP sensor’s transmission resonances exhibited a refractive index sensitivity of Δλ/Δn ~ -6200nm/RIU and ΔΙ/Δn ~5900dB/RIU, which is the highest reported spectral sensitivity of a fiber optic sensor to bulk index changes within the gas regime. The complete device provides the first demonstration of the chemically specific gas sensing capabilities of CNTs utilizing their optical characteristics. This is proven by investigating the spectral response of the sensor before and after the adhesion of CNTs to alkane gases along with carbon dioxide. The device shows a distinctive spectral response in the presence of gaseous CO2 over and above what is expected from general changes in the bulk refractive index. This fiber device yielded a limit of detection of 150ppm for CO2 at a pressure of one atmosphere. Additionally the adhered CNTs actually reduce sensitivity of the device to changes in bulk refractive index of the surrounding medium. The polarization properties of the LSP sensor resonances are also investigated and it is shown that there is a reduction in the overall azimuthal polarization after the CNTs are applied. These optical devices offer a way of exploiting optically the chemical selectivity of carbon nanotubes, thus providing the potential for real-world applications in gas sensing in many inflammable and explosive environments. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interorganizational team research is a growing body of literature and research has started toexamine team related factors such as interorganizational trust (i.e. Stock, 2006) in theinterorganizational setting. This research applies insights from the intraorganizational teamfield into the interorganizational team setting in order to determine the team related factorspertaining to effective collaboration in medical device innovation projects.Interorganizational collaboration has been a persistent feature within the interorganizationalrelations literature, due to the added benefits that can come with working collaborativelytowards a common goal (Berg-Weger & Schnieder, 1998). While much research has exploredthe structures and performance outcomes of engaging in this cross-boundary working, theliterature is sparse with respect to interpersonal relationships, practices and processes leadingto effective collaboration (Bergenholtz & Waldstrom, 2011; Majchrzak, Jarvenpaa & Bargherz,2015). An interpretivist perspective has informed an exploratory mixed methods approach to datacollection, with contextual insights informing each phase of data collection. Three exploratoryphases of data collection have provided (1) qualitative ethnography data, (1i) qualitativeinterview data and (2) quantitative survey data. The NHS has recently set out agendas to increase innovative procurement (Department ofHealth, 2008), work more closely with industry and SMEs (Innovation and Procurement Plan:Department of Health, 2009) and to increase innovative practice (IHW: NHS, 2011). SMEsdeveloping novel medical devices require input from the NHS to ensure that their devices areclinically applicable and therefore will be adopted by the NHS. These contextual insightsprovide the backdrop for Studies 1i and 2. The findings suggest that the intraorganizational team literature can be extended into theinterorganizational collaboration literature, whilst also explaining the factors relating toeffectiveness and success of interorganizational team innovation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A szerzők tanulmányukban az információbiztonság egy merőben új, minőségi változást hozó találmányával, a kvantumkulcscserével (QKD-vel – quantum key distribution) foglalkoznak. Céljuk az, hogy az újdonságra mint informatikai biztonsági termékre tekintsenek, és megvizsgálják a bevezetéséről szóló vállalati döntés során felmerülő érveket, ellenérveket. Munkájuk egyaránt műszaki és üzleti szemléletű. Előbb elkülönítik a kvantumkulcscsere hagyományos eljárásokkal szembeni használatának motiváló tényezőit, és megállapítják, milyen körülmények között szükséges a napi működésben alkalmazni. Ezt követően a forgalomban is kapható QKD-termékek tulajdonságait és gyártóit szemügyre véve megfogalmazzák a termék széles körű elterjedésének korlátait. Végül a kvantumkulcscsere-termék bevezetéséről szóló vállalati döntéshozás különböző aspektusait tekintik át. Információbiztonsági és üzleti szempontból összehasonlítják az új, valamint a hagyományosan használt kulcscsereeszközöket. Javaslatot tesznek a védendő információ értékének becslésére, amely a használatbavétel költség-haszon elemzését támaszthatja alá. Ebből levezetve megállapítják, hogy mely szervezetek alkotják a QKD lehetséges célcsoportját. Utolsó lépésként pedig arra keresik a választ, melyik időpont lehet ideális a termék bevezetésére. _____ This study aims to illuminate Quantum Key Distribution (QKD), a new invention that has the potential to bring sweeping changes to information security. The authors’ goal is to present QKD as a product in the field of IT security, and to examine several pro and con arguments regarding the installation of this product. Their work demonstrates both the technical and the business perspectives of applying QKD. First they identify motivational factors of using Quantum Key Distribution over traditional methods. Then the authors assess under which circumstances QKD could be necessary to be used in daily business. Furthermore, to evaluate the limitations of its broad spread, they introduce the vendors and explore the properties of their commercially available QKD products. Bearing all this in mind, they come out with numerous factors that can influence corporate decision making regarding the installation of QKD. The authors compare the traditional and the new tools of key distribution from an IT security and business perspective. They also take efforts to estimate the value of the pieces of information to be protected. This could be useful for a subsequent cost–benefit analysis. Their findings try to provide support for determining the target audience of QKD in the IT security market. Finally the authors attempt to find an ideal moment for an organization to invest in Quantum Key Distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation is about the research carried on developing an MPS (Multipurpose Portable System) which consists of an instrument and many accessories. The instrument is portable, hand-held, and rechargeable battery operated, and it measures temperature, absorbance, and concentration of samples by using optical principles. The system also performs auxiliary functions like incubation and mixing. This system can be used in environmental, industrial, and medical applications. ^ Research emphasis is on system modularity, easy configuration, accuracy of measurements, power management schemes, reliability, low cost, computer interface, and networking. The instrument can send the data to a computer for data analysis and presentation, or to a printer. ^ This dissertation includes the presentation of a full working system. This involved integration of hardware and firmware for the micro-controller in assembly language, software in C and other application modules. ^ The instrument contains the Optics, Transimpedance Amplifiers, Voltage-to-Frequency Converters, LCD display, Lamp Driver, Battery Charger, Battery Manager, Timer, Interface Port, and Micro-controller. ^ The accessories are a Printer, Data Acquisition Adapter (to transfer the measurements to a computer via the Printer Port and expand the Analog/Digital conversion capability), Car Plug Adapter, and AC Transformer. This system has been fully evaluated for fault tolerance and the schemes will also be presented. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence-enhanced optical imaging is an emerging non-invasive and non-ionizing modality towards breast cancer diagnosis. Various optical imaging systems are currently available, although most of them are limited by bulky instrumentation, or their inability to flexibly image different tissue volumes and shapes. Hand-held based optical imaging systems are a recent development for its improved portability, but are currently limited only to surface mapping. Herein, a novel optical imager, consisting primarily of a hand-held probe and a gain-modulated intensified charge coupled device (ICCD) detector, is developed towards both surface and tomographic breast imaging. The unique features of this hand-held probe based optical imager are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) reduce overall imaging time using a unique measurement geometry, and (iii) perform tomographic imaging for tumor three-dimensional (3-D) localization. Frequency-domain based experimental phantom studies have been performed on slab geometries (650 ml) under different target depths (1-2.5 cm), target volumes (0.45, 0.23 and 0.10 cc), fluorescence absorption contrast ratios (1:0, 1000:1 to 5:1), and number of targets (up to 3), using Indocyanine Green (ICG) as fluorescence contrast agents. An approximate extended Kalman filter based inverse algorithm has been adapted towards 3-D tomographic reconstructions. Single fluorescence target(s) was reconstructed when located: (i) up to 2.5 cm deep (at 1:0 contrast ratio) and 1.5 cm deep (up to 10:1 contrast ratio) for 0.45 cc-target; and (ii) 1.5 cm deep for target as small as 0.10 cc at 1:0 contrast ratio. In the case of multiple targets, two targets as close as 0.7 cm were tomographically resolved when located 1.5 cm deep. It was observed that performing multi-projection (here dual) based tomographic imaging using a priori target information from surface images, improved the target depth recovery over using single projection based imaging. From a total of 98 experimental phantom studies, the sensitivity and specificity of the imager was estimated as 81-86% and 43-50%, respectively. With 3-D tomographic imaging successfully demonstrated for the first time using a hand-held based optical imager, the clinical translation of this technology is promising upon further experimental validation from in-vitro and in-vivo studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are situations in which it is very important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. The goal of this project was to develop an ultra fast, direct PCR method for forensic genotyping of oral swabs. The procedure developed eliminates the need for cellular digestion and extraction of the sample by performing those steps in the PCR tube itself. Then, special high-speed polymerases are added which are capable of amplifying a newly developed 7 loci multiplex in under 16 minutes. Following the amplification, a postage stamp sized microfluidic device equipped with specially designed entangled polymer separation matrix, yields a complete genotype in 80 seconds. The entire process is rapid and reliable, reducing the time from sample to genotype from 1-2 days to under 20 minutes. Operation requires minimal equipment and can be easily performed with a small high-speed thermal-cycler, reagents, and a microfluidic device with a laptop. The system was optimized and validated using a number of test parameters and a small test population. The overall precision was better than 0.17 bp and provided a power of discrimination greater than 1 in 106. The small footprint, and ease of use will permit this system to be an effective tool to quickly screen and identify individuals detained at ports of entry, police stations and remote locations. The system is robust, portable and demonstrates to the forensic community a simple solution to the problem of rapid determination of genetic identity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a low-energy glow-discharge process using reactive ion etching system that enables non-circular device patterns, such as squares or hexagons, to be formed from a precursor array of uniform circular openings in polymethyl methacrylate, PMMA, defined by electron beam lithography. This technique is of a particular interest for bit-patterned magnetic recording medium fabrication, where close packed square magnetic bits may improve its recording performance. The process and results of generating close packed square patterns by self-limiting low-energy glow-discharge are investigated. Dense magnetic arrays formed by electrochemical deposition of nickel over self-limiting formed molds are demonstrated.