976 resultados para Orthodontic mini-implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Empirical evidence has indicated that only a subsample of studies conducted reach full-text publication and this phenomenon has become known as publication bias. A form of publication bias is the selectively delayed full publication of conference abstracts. The objective of this article was to examine the publication status of oral abstracts and poster-presentation abstracts, included in the scientific program of the 82nd and 83rd European Orthodontic Society (EOS) congresses, held in 2006 and 2007, and to identify factors associated with full-length publication. METHODS A systematic search of PubMed and Google Scholar databases was performed in April 2013 using author names and keywords from the abstract title to locate abstract and full-article publications. Information regarding mode of presentation, type of affiliation, geographical origin, statistical results, and publication details were collected and analyzed using univariable and multivariable logistic regression. RESULTS Approximately 51 per cent of the EOS 2006 and 55 per cent of the EOS 2007 abstracts appeared in print more than 5 years post congress. A mean period of 1.32 years elapsed between conference and publication date. Mode of presentation (oral or poster), use of statistical analysis, and research subject area were significant predictors for publication success. LIMITATIONS Inherent discrepancies of abstract reporting, mainly related to presentation of preliminary results and incomplete description of methods, may be considered in analogous studies. CONCLUSIONS On average 52.2 per cent of the abstracts presented at the two EOS conferences reached full publication. Abstracts presented orally, including statistical analysis, were more likely to get published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic reviews of well-designed trials constitute a high level of scientific evidence and are important for medical decision making. Meta-analysis facilitates integration of the evidence using a transparent and systematic approach, leading to a broader interpretation of treatment effectiveness and safety than can be attained from individual studies. Traditional meta-analyses are limited to comparing just 2 interventions concurrently and cannot combine evidence concerning multiple treatments. A relatively recent extension of the traditional meta-analytical approach is network meta-analysis, which allows, under certain assumptions, the quantitative synthesis of all evidence under a unified framework and across a network of all eligible trials. Network meta-analysis combines evidence from direct and indirect information via common comparators; interventions can therefore be ranked in terms of the analyzed outcome. In this article, the network meta-analysis approach is introduced in a nontechnical manner using a worked example on the treatment effectiveness of conventional and self-ligating appliances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To identify the timing of significant arch dimensional increases during orthodontic alignment involving round and rectangular nickel-titanium (NiTi) wires and rectangular stainless steel (SS). A secondary aim was to compare the timing of changes occurring with conventional and self-ligating fixed appliance systems. METHODS In this non-primary publication, additional data from a multicenter randomised trial initially involving 96 patients, aged 16 years and above, were analysed. The main pre-specified outcome measures were the magnitude and timing of maxillary intercanine, interpremolar, and intermolar dimensions. Each participant underwent alignment with a standard Damon (Ormco, Orange, CA) wire sequence for a minimum of 34 weeks. Blinding of clinicians and patients was not possible; however, outcome assessors and data analysts were kept blind to the appliance type during data analysis. RESULTS Complete data were obtained from 71 subjects. Significant arch dimensional changes were observed relatively early in treatment. In particular, changes in maxillary inter-first and second premolar dimensions occurred after alignment with an 0.014in. NiTi wire (P<0.05). No statistical differences in transverse dimensions were found between rectangular NiTi and working SS wires for each transverse dimension (P>0.05). Bracket type had no significant effect on the timing of the transverse dimensional changes. CONCLUSIONS Arch dimensional changes were found to occur relatively early in treatment, irrespective of the appliance type. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed. CLINICAL SIGNIFICANCE On the basis of this research orthodontic expansion may occur relatively early in treatment. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the types of articles and authorship characteristics of three orthodontic journals--American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), The Angle Orthodontist (AO), and European Journal of Orthodontics (EJO)--published between 2008 and 2012 and to assess the differences in content within this period and an earlier period of 1998 to 2002. MATERIALS AND METHODS Each journal's content was accessed through the web edition. From each article, the following parameters were recorded: article type, number of authors, number of affiliations, source of article (referring to the first author's affiliation), and geographic origin. Descriptive statistics were performed and selected parameters were analyzed with the Pearson chi-square or Fisher exact test for independence at the .05 level of significance. RESULTS Review of differences between the two periods showed that the number of publications was almost double. The percentages of multi-authored articles increased. Fewer studies derived from the United States/Canada and European Union countries. Increases for articles from non-European Union countries, Asia, and other countries were found. Characteristics of the second period showed that the EJO and AO published more research articles, whereas the AJODO regularly published case reports and other articles. Approximately 75% of all studies derived from orthodontic departments. CONCLUSIONS The publications from 1998-2002 and 2008-2012 were significantly different both in terms of numbers and characteristics. Within 2008-2012 there were notable differences between the three journals concerning the type and origin of the publications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sample size calculations are advocated by the Consolidated Standards of Reporting Trials (CONSORT) group to justify sample sizes in randomized controlled trials (RCTs). This study aimed to analyse the reporting of sample size calculations in trials published as RCTs in orthodontic speciality journals. The performance of sample size calculations was assessed and calculations verified where possible. Related aspects, including number of authors; parallel, split-mouth, or other design; single- or multi-centre study; region of publication; type of data analysis (intention-to-treat or per-protocol basis); and number of participants recruited and lost to follow-up, were considered. Of 139 RCTs identified, complete sample size calculations were reported in 41 studies (29.5 per cent). Parallel designs were typically adopted (n = 113; 81 per cent), with 80 per cent (n = 111) involving two arms and 16 per cent having three arms. Data analysis was conducted on an intention-to-treat (ITT) basis in a small minority of studies (n = 18; 13 per cent). According to the calculations presented, overall, a median of 46 participants were required to demonstrate sufficient power to highlight meaningful differences (typically at a power of 80 per cent). The median number of participants recruited was 60, with a median of 4 participants being lost to follow-up. Our finding indicates good agreement between projected numbers required and those verified (median discrepancy: 5.3 per cent), although only a minority of trials (29.5 per cent) could be examined. Although sample size calculations are often reported in trials published as RCTs in orthodontic speciality journals, presentation is suboptimal and in need of significant improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. MATERIAL AND METHODS This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. RESULTS AND CONCLUSIONS The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM The aim of this prospective, randomized, controlled multicenter study was to determine the 3-year efficacy and stability of the soft and hard tissues at implants with a different geometry that were placed in fresh extraction sockets. MATERIAL AND METHODS Implants with two different configurations, cylindrical (Group A) or conical/cylindrical (Group B) were installed, and healing abutments were attached. Sixteen weeks after implant placement, subjects returned for a re-entry procedure. Prosthetic restorations were delivered 22 weeks after implant placement. Each subject was placed in a 3-year follow-up program, including examinations at yearly visits including various soft tissue and bone level parameters. RESULTS The percentage of sites that were considered inflamed during the follow-up period was stable and varied between 8.8% and 10.2%. The radiographic examinations documented improved bone levels at the final examination and the mean improvement from baseline (placement of permanent restoration; PR) amounted to 0.17 ± 0.67 mm. More than 70% (54 of 76) of the implants monitored in this study suffered no bone loss during the maintenance period. Moreover, there was an obvious "gain" of interproximal soft tissue volume and at the 3-year examination around 25% of all embrasure gaps were completely filled with "papillae". CONCLUSIONS Both conical/cylindrical and cylindrical implants placed in fresh extraction sockets allowed proper soft and hard tissue healing to occur. At both types of implants, mucosal inflammation was infrequent, marginal bone levels were maintained, and soft tissue volume increased gradually after the placement of the permanent restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Limited data exist on the longitudinal crestal bone changes around teeth compared with implants in partially edentulous patients. This study sought to compare the 10-year radiographic crestal bone changes (bone level [BL]) around teeth and implants in periodontally compromised (PCPs) and periodontally healthy (PHPs) patients. METHODS A total of 120 patients were evaluated for the radiographic crestal BL around dental implants and adjacent teeth at time of implant crown insertion and at the 10-year follow-up. Sixty patients had a previous history of periodontitis (PCPs), and the remaining 60 were PHPs. In each category (PCP and PHP), two different implant systems were used. The mean BL change at the implant and at the adjacent tooth at the interproximal area was calculated by subtracting the radiographic crestal BL at the time of crown cementation from the radiographic crestal BL at the 10-year follow-up. RESULTS At 10 years after therapy, the survival rate ranged from 80% to 95% for subgroups for implants, whereas it was 100% for the adjacent teeth. In all eight different patient categories evaluated, teeth demonstrated a significantly more stable radiographic BL compared with adjacent dental implants (teeth BL, 0.44 ± 0.23 mm; implant BL, 2.28 ± 0.72 mm; P <0.05). Radiographic BL changes around teeth seemed not to be influenced by the presence or absence of advanced bone loss (≥3 mm) at the adjacent implants. CONCLUSIONS Natural teeth yielded better long-term results with respect to survival rate and marginal BL changes compared with dental implants. Moreover, these findings also extend to teeth with an initial reduced periodontal attachment level, provided adequate periodontal treatment and maintenance are performed. As a consequence, the decision of tooth extraction attributable to periodontal reasons in favor of a dental implant should be carefully considered in partially edentulous patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To evaluate technical complications and failures of zirconia-based fixed prostheses supported by implants. MATERIALS AND METHODS Consecutive patients received zirconia-based single crowns (SCs) and fixed dental prostheses (FDPs) on implants in a private clinical setting between 2005 and 2010. One dentist performed all surgical and prosthetic procedures, and one master technician performed and coordinated all laboratory procedures. One-piece computer-aided design/ computer-assisted manufacture technology was used to fabricate abutments and frameworks, which were directly connected at the implant level, where possible. All patients were involved in a recall maintenance program and were finally reviewed in 2012. Data on framework fractures, chipping of veneering ceramics, and other technical complications were recorded. The primary endpoint was failure of the prostheses, ie, the need for a complete remake. A life table analysis was calculated. RESULTS A total of 289 implants supported 193 zirconia-based prostheses (120 SCs and 73 FDPs) in 127 patients (51 men, 76 women; average age: 62.5 ± 13.4 years) who were reviewed in 2012. Twenty-five (13%) prostheses were cemented on 44 zirconia abutments and 168 (87%) prostheses were screw-retained directly at the implant level. Fracture of 3 frameworks (1 SC, 2 FDPs) was recorded, and significant chipping resulted in the remake of 3 prostheses (1 SC, 2 FDPs). The 7-year cumulative survival rate was 96.4% ± 1.99%. Minor complications comprised 5 loose screws (these were retightened), small chips associated with 3 prostheses (these were polished), and dislodgement of 3 prostheses (these were recemented). Overall, 176 prostheses remained free of technical problems. CONCLUSIONS Zirconia-based prostheses screwed directly to implants are clinically successful in the short and medium term.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIM So far there is little evidence from randomised clinical trials (RCT) or systematic reviews on the preferred or best number of implants to be used for the support of a fixed prosthesis in the edentulous maxilla or mandible, and no consensus has been reached. Therefore, we reviewed articles published in the past 30 years that reported on treatment outcomes for implant-supported fixed prostheses, including survival of implants and survival of prostheses after a minimum observation period of 1 year. MATERIAL AND METHODS MEDLINE and EMBASE were searched to identify eligible studies. Short and long-term clinical studies were included with prospective and retrospective study designs to see if relevant information could be obtained on the number of implants related to the prosthetic technique. Articles reporting on implant placement combined with advanced surgical techniques such as sinus floor elevation (SFE) or extensive grafting were excluded. Two reviewers extracted the data independently. RESULTS A primary search was broken down to 222 articles. Out of these, 29 studies comprising 26 datasets fulfilled the inclusion criteria. From all studies, the number of planned and placed implants was available. With two exceptions, no RCTs were found, and these two studies did not compare different numbers of implants per prosthesis. Eight studies were retrospective; all the others were prospective. Fourteen studies calculated cumulative survival rates for 5 and more years. From these data, the average survival rate was between 90% and 100%. The analysis of the selected articles revealed a clear tendency to plan 4 to 6 implants per prosthesis. For supporting a cross-arch fixed prosthesis in the maxilla, the variation is slightly greater. CONCLUSIONS In spite of a dispersion of results, similar outcomes are reported with regard to survival and number of implants per jaw. Since the 1990s, it was proven that there is no need to install as many implants as possible in the available jawbone. The overwhelming majority of articles dealing with standard surgical procedures to rehabilitate edentulous jaws uses 4 to 6 implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The generation of learning goals (LGs) that are aligned with learning needs (LNs) is one of the main purposes of formative workplace-based assessment. In this study, we aimed to analyse how often trainer–student pairs identified corresponding LNs in mini-clinical evaluation exercise (mini-CEX) encounters and to what degree these LNs aligned with recorded LGs, taking into account the social environment (e.g. clinic size) in which the mini-CEX was conducted. METHODS Retrospective analyses of adapted mini-CEX forms (trainers’ and students’ assessments) completed by all Year 4 medical students during clerkships were performed. Learning needs were defined by the lowest score(s) assigned to one or more of the mini-CEX domains. Learning goals were categorised qualitatively according to their correspondence with the six mini-CEX domains (e.g. history taking, professionalism). Following descriptive analyses of LNs and LGs, multi-level logistic regression models were used to predict LGs by identified LNs and social context variables. RESULTS A total of 512 trainers and 165 students conducted 1783 mini-CEXs (98% completion rate). Concordantly, trainer–student pairs most often identified LNs in the domains of ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation/efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710). Of the 446 LGs noted in total, the most frequently noted were ‘physical examination’ (49%) and ‘history taking’ (21%). Corresponding LNs as well as social context factors (e.g. clinic size) were found to be predictors of these LGs. CONCLUSIONS Although trainer–student pairs often agreed in the LNs they identified, many assessments did not result in aligned LGs. The sparseness of LGs, their dependency on social context and their partial non-alignment with students’ LNs raise questions about how the full potential of the mini-CEX as not only a ‘diagnostic’ but also an ‘educational’ tool can be exploited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Defining learning goals (LG) in alignment with learning needs (LN) is one of the key purposes of formative workplace-based assessment, but studies about this topic are scarce. Summary of Work: We analysed quantitatively and qualitatively how often trainer-student pairs identified the same LN during Mini Clinical Evaluation Exercises (Mini-CEX) in clerkships and to what degree those LNs were in line with the recorded LGs. Multilevel logistic regression models were used to predict LGs by identified LNs, controlling for context variables. Summary of Results: 512 trainers and 165 students conducted 1783 Mini-CEX (98% completion rate). Concordantly, trainer-student pairs most often identified LNs in the domains ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation / efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710), with a total of 446 LGs. Of these, the most frequent LGs were ‘physical examination’ (49% of 446 LGs) and ‘history taking’ (21%); corresponding LNs as well as context variables (e.g. clinic size) were found to be predictors of these LGs. Discussion and Conclusions: Although trainer-student pairs often agreed in their identified LNs, many assessments did not result in an aligned LG or a LG at all. Interventions are needed to enhance the proportion of (aligned) LGs in Mini-CEX in order to tap into its full potential not only as a ‘diagnostic’ but also as an ‘educational tool’. Take-home messages: The sparseness of LGs, their dependency on context variables and their partial non-alignment with students’ LNs raise the question of how the effectiveness of Mini-CEX can be further enhanced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY BACKGROUND/OBJECTIVES Orthodontic management of maxillary canine impaction (MCI), including forced eruption, may result in significant root resorption; however, the association between MCI and orthodontically induced root resorption (OIRR) is not yet sufficiently established. The purpose of this retrospective cohort study was to comparatively evaluate the severity of OIRR of maxillary incisors in orthodontically treated patients with MCI. Additionally, impaction characteristics were associated with OIRR severity. SUBJECTS AND METHODS The sample comprised 48 patients undergoing fixed-appliance treatment-24 with unilateral/bilateral MCI and 24 matched controls without impaction. OIRR was calculated using pre- and post-operative panoramic tomograms. The orientation of eruption path, height, sector location, and follicle/tooth ratio of the impacted canine were also recorded. Mann-Whitney U-test and univariate and multivariate linear mixed models were used to test for the associations of interest. RESULTS Maxillary central left incisor underwent more OIRR in the impaction group (mean difference = 0.58mm, P = 0.04). Overall, the impaction group had 0.38mm more OIRR compared to the control (95% confidence interval, CI: 0.03, 0.74; P = 0.04). However, multivariate analysis demonstrated no difference in the amount of OIRR between impaction and non-impaction groups overall. A positive association between OIRR and initial root length was observed (95% CI: 0.08, 0.27; P < 0.001). The severity of canine impaction was not found to be a significant predictor of OIRR. LIMITATIONS This study was a retrospective study and used panoramic tomograms for OIRR measurements. CONCLUSIONS This study indicates that MCI is a weak OIRR predictor. Interpretation of the results needs caution due to the observational nature of the present study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose.This retrospective cohort study evaluated factors for peri-implant bone level changes (ΔIBL) associated with an implant type with inner-cone implant-abutment connection, rough neck surface, and platform switching (AT). Materials and Methods. All AT placed at the Department of Prosthodontics of the University of Bern between January 2004 and December 2005 were included in this study. All implants were examined by single radiographs using the parallel technique taken at surgery (T0) and obtained at least 6 months after surgery (T1). Possible influencing factors were analysed first using t-test (normal distribution) or the nonparametric Wilcoxon test (not normal distribution), and then a mixed model q variance analysis was performed. Results. 43 patients were treated with 109 implants. Five implants in 2 patients failed (survival rate: 95.4%).Mean ΔIBL in group 1 (T1: 6–12 months after surgery) was −0.65 ± 0.82mm and −0.69 ± 0.82mm in group 2 (T1: >12 months after surgery) (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction. METHODS Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy. RESULTS All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris. CONCLUSIONS This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases.