980 resultados para Optical Flow Tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most hybrid zones have existed for hundreds or thousands of years but have generally been observed for only a short time period. Studies extending over periods long enough to track evolutionary changes in the zones or assess the ultimate outcome of hybridization are scarce. Here, we describe the evolution over time of the level of genetic isolation between two karyotypically different species of shrews (Sorex araneus and Sorex antinorii) at a hybrid zone located in the Swiss Alps. We first evaluated hybrid zone movement by contrasting patterns of gene flow and changes in cline parameters (centre and width) using 24 microsatellite loci, between two periods separated by 10 years apart. Additionally, we tested the role of chromosomal rearrangements on gene flow by analysing microsatellite loci located on both rearranged and common chromosomes to both species. We did not detect any movement of the hybrid zone during the period analysed, suggesting that the zone is a typical tension zone. However, the gene flow was significantly lower among the rearranged than the common chromosomes for the second period, whereas the difference was only marginally significant for the first period. This further supports the role of chromosomal rearrangements on gene flow between these taxa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY Regional drug delivery is an approach designed to improve the selectivity of anticancer chemotherapy. The advantage of regional treatments lies in increasing the drug concentration in the affected organ, while the rest of the organism is spared, thus improving efficacy and limiting treatment toxicity. The goal of this thesis was to assess the distribution throughout the body and the disposition (pharmacokinetics) of two anticancer agents, doxorubicin and gemcitabine, administered by two different regional administration modalities: isolated lung perfusion (ILP) for pulmonary metastases from soft tissue sarcomas and abdominal stop-flow hypoxic perfusion for advanced pancreatic cancers, respectively. For this purpose, two high-performance liquid chromatography methods were developed and validated. The first enabled the determination of doxorubicin in four different biological matrices: serum, reconstituted effluent, tissues with low levels of doxorubicin and tissues with high levels of doxorubicin. The second allows the analysis of gemcitabine and its principal metabolite dFdU in plasma. The administration of doxorubicin by ILP was studied in three preclinical studies (one on pigs and two on rats). It was first shown that, regardless of the administration mode, doxorubicin was not homogeneously distributed throughout the lung and that some regions remained out of reach. Secondly, it was demonstrated that doxorubicin did not adequately reach the tumours despite very high levels found in the lung. Finally, an attempt to enhance the doxorubicin tumoural uptake by pharmacologic modulation using two P-glycoprotein inhibitors, cyclosporin and valspodar, was unsuccessful. The last part of this work involves the administration of gemcitabine by abdominal stop-flow as a part of a phase I clinical trial in patients with advanced pancreatic disease or resistant malignant ascites. The study has demonstrated that the regional exposure to gemcitabine was increased while the exposure of the entire organism was similar to standard intravenous administrations. From a toxicological perspective, the procedure was rather well tolerated. However, even if no clinical response is expected from a phase I study, no hints of clinical responses were unfortunately observed. In conclusion, even if loco-regional therapies may afford the pharmacological advantage of increasing anticancer drug levels at the tumour site, further studies of these investigational treatment modalities are warranted to ascertain whether they can provide a significant improvement of the cancer therapy for patients, in terms of treatment tolerability, improved responses and survival rates. RÉSUMÉ L'administration locorégionale d'agents anticancéreux est une approche destinée à augmenter la sélectivité du traitement. L'avantage des traitements régionaux repose sur le fait que la concentration du médicament cytostatique est augmentée dans l'organe où est localisée la tumeur, alors que le reste de l'organisme est épargné, améliorant ainsi en théorie l'efficacité du traitement et en limitant sa toxicité. Le but de ce travail de thèse avait pour objectif de préciser, la pharmacocinétique au sein de l'organisme de deux agents anticancéreux, la doxorubicine et la gemcitabine, administrés par deux types de perfusions loco-régionales: la perfusion isolée du poumon (ILP) pour les métastases pulmonaires de sarcomes des tissus mous, et la perfusion hypoxique (stop-flow) abdominale pour les cancers avancés du pancréas. Dans cette optique, deux méthodes de chromatographie liquide à haute performance ont été développées et validées. La première permet le dosage de la doxorubicine dans quatre milieux biologiques: le sérum, l'effluent reconstitué, ainsi que des tissus contenant des concentrations faibles et élevées en doxorubicine. La seconde méthode permet le dosage dans le plasma de la gemcitabine et de son principal métabolite, le dFdU. L'administration de doxorubicine par ILP a été étudiée dans trois études précliniques (une chez le porc et deux chez le rat). Il a été montré, dans un premier temps, que la doxorubicine n'était pas distribuée de façon homogène au sein du poumon, quel que soit son mode d'administration. Dans un deuxième temps, il a été démontré que le médicament n'atteignait pas les tumeurs de façon adéquate, malgré des concentrations très élevées au sein du tissu pulmonaire. Finalement, une tentative d'augmenter la pénétration tumorale de la doxorubicine par une modulation pharmacologique de la P-glycoprotéine en utilisant la cyclosporine et le valspodar n'a pas abouti. La dernière partie de ce travail concernait l'administration de gemcitabine par stop-flow abdominal dans le cadre d'une étude clinique de phase I menée auprès de patients atteints de cancers avancés du pancréas ou d'ascites malignes réfractaires. Cette étude a démontré que l'exposition régionale à la gemcitabine était augmentée, alors que l'exposition de l'organisme était similaire à une administration de dose standard par voie intraveineuse. D'un point de vue toxicologique la procédure fut relativement bien tolérée. Cependant, même s'il n'est pas attendu de réponses cliniques dans une étude de phase I, aucun signe de réponse au traitement n'a pu être malheureusement observé. En conclusion, même si les thérapies loco-régionales présentent -en théorie- l'avantage pharmacologique d'augmenter les taux du médicaments anticancéreux sur le site de la tumeur, d'autres études précliniques et cliniques sont nécessaires pour démontrer que ces nouvelles modalités de traitement, de nature investigationelle à présent, apportent une réelle amélioration pour la prise en charge des patients cancéreux, en terme de tolérance au traitement et de l'augmentation des taux de réponses et de survie.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamically polarized membrane proteins define different cell boundaries and have an important role in intercellular communication-a vital feature of multicellular development. Efflux carriers for the signalling molecule auxin from the PIN family are landmarks of cell polarity in plants and have a crucial involvement in auxin distribution-dependent development including embryo patterning, organogenesis and tropisms. Polar PIN localization determines the direction of intercellular auxin flow, yet the mechanisms generating PIN polarity remain unclear. Here we identify an endocytosis-dependent mechanism of PIN polarity generation and analyse its developmental implications. Real-time PIN tracking showed that after synthesis, PINs are initially delivered to the plasma membrane in a non-polar manner and their polarity is established by subsequent endocytic recycling. Interference with PIN endocytosis either by auxin or by manipulation of the Arabidopsis Rab5 GTPase pathway prevents PIN polarization. Failure of PIN polarization transiently alters asymmetric auxin distribution during embryogenesis and increases the local auxin response in apical embryo regions. This results in ectopic expression of auxin pathway-associated root-forming master regulators in embryonic leaves and promotes homeotic transformation of leaves to roots. Our results indicate a two-step mechanism for the generation of PIN polar localization and the essential role of endocytosis in this process. It also highlights the link between endocytosis-dependent polarity of individual cells and auxin distribution-dependent cell fate establishment for multicellular patterning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cerebral autoregulation (CA) is a protective mechanism which maintains the steadiness of the cerebral blood flow (CBF) through a broad range of systemic blood pressure (BP). Acute hypertension has been shown to reduce the cerebrovascular adaptation to BP variations. However, it is still unknown whether CA is impaired in chronic hypertension. This study evaluated whether a strict control of BP affects the CA in patients with chronic hypertension, and compared a valsartan-based regimen to a regimen not inhibiting the renin-angiotensin-aldosterone system (non-RAAS). Methods: Eighty untreated patients with isolated systolic hypertension were randomized to valsartan 320 mg or to a non-RAAS regimen during 6 months. The medication was upgraded to obtain BP <140/90 mm Hg. Continuous recordings of arterial BP and CBF velocity (transcranial Doppler) were performed during periods of 5 minutes, at rest, and at different levels of alveolar CO(2) pressure provided by respiratory maneuvers. The dominant frequency of CBF oscillations was determined for each patient. Dynamic CA was measured as the mean phase shift between BP and CBF by cross-spectral analysis in the medium frequency and in the dominant CBF frequency. Results: Mean ambulatory 24-hour BP fell from 144/87 to 127/79 mm Hg in the valsartan group and from 144/87 to 134/81 mm Hg in the non-RAAS group (p = 0.13). Both groups had a similar reduction in the central BP and in the carotido-femoral pulse wave velocity. The average phase shift between BP fluctuations and CBF response at rest was normal at randomization (1.82 ± 0.08 s), which is considered a preserved autoregulation and increased to 1.91 ± 0.12 s at the end of study (p = 0.45). The comparison of both treatments showed no significant difference (-0.01 ± 0.17 s vs. 0.16 ± 0.16 s, p = 0.45) for valsartan versus non-RAAS groups. The plasmatic level of glycosylated hemoglobin decreased in the valsartan arm compared to the non-RAAS arm (-0.23 ± 0.06 vs. -0.08 ± 0.07%, p = 0.07). Conclusions: In elderly hypertensive men with isolated chronic systolic hypertension, CA seems efficient at baseline and is not significantly affected by 6 months of BP-lowering treatment. This suggests that the preventive effects of BP medication against stroke are not mediated through a restoration of the CA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La peau est sujette à un vieillissement intrinsèque (processus naturel et chronologique) et extrinsèque (processus induit par l'environnement et notamment les rayons UV). Plusieurs études ont montré que le vieillissement cutané s'accompagne d'une réduction de la densité capillaire au sein du derme et d'une dégradation de plusieurs protéines de la matrice extracellulaire. Cette atteinte morphologique est associée à une diminution de la capacité vasodilatatrice maximale de la microcirculation dermique et en particulier, de la réponse maximale du flux sanguin cutané à un échauffement local de la surface cutanée à des températures avoisinant les 43-44°C. Cette réponse, appelée hyperémie locale induite par la chaleur (local thermal hyperemia), est facilement mesurable par des investigations non invasives, telles que le laser Doppler. Nous avons entrepris cette étude afin d'investiguer les effets de l'âge sur la réactivité de la microcirculation dermique dans des zones cutanées exposées différemment aux rayons UV. Pour ce faire, nous avons étudié, chez des patients jeunes (18 à 30 ans, n=13) et des patients âgés (> 60 ans, n=13), la vasodilatation cutanée induite par réchauffement local de la peau, au niveau de 3 sites anatomiques différents (la cuisse, l'avant- bras et le front). Les mesures ont été effectuées au moyen d'un laser Doppler. Pour chaque sujet et chaque site, la température cutanée fut tout d'abord amenée à 34°C par 2 corps de chauffe (A et B), disposés de manière adjacente sur la peau. La température fut ensuite augmentée à 39°C (corps de chauffe A) et à 41°C (corps de chauffe B) pour une durée de 30 minutes, dans l'optique d'induire une vasodilatation sous- maximale. Ensuite, la température fut augmentée à 43 °C (corps de chauffe A et B) pour 15 minutes supplémentaires. Enfin, la vasodilatation maximale a été induite par un échauffement local à 44°C pour 15 minutes supplémentaires (corps de chauffe A et B). L'enregistrement séquentiel du flux sanguin cutané, effectué chaque minute par laser Doppler imager, donne des images sur lesquelles peut être calculé le flux sanguin cutané (unités de perfusion, PU). Par la suite, nous avons calculé les conductances vasculaires cutanées (CVC), en divisant le flux sanguin (PU) par la tension artérielle moyenne (mmHg), afin de permettre une normalisation entre les différents sujets. Les CVC, évaluées au temps de départ (température 34°C) et après vasodilatation maximale (température 44°C), étaient plus hautes au niveau du front qu'au niveau des 2 autres sites anatomiques. Sur les 3 sites, la CVC maximale (température 44°C) diminuait avec l'âge mais de façon moins importante au niveau du front, en comparaison avec les 2 autres sites. La réponse aux températures sous-maximales (température 39 et 41°C), exprimée en pourcentage de la CVC maximale, ne variait pas avec l'âge ni en fonction du site anatomique étudié. En conclusion, cette étude est la première à étudier simultanément l'hyperémie locale induite par la chaleur sur 3 sites ayant une exposition différente aux rayons UV. Le processus utilisé (laser Doppler imager) est également unique dans la littérature concernant les altérations de la microcirculation cutanée en lien avec l'âge. Cette étude confirme ainsi que le vieillissement cutané intrinsèque et/ou extrinsèque réduit la capacité vasodilatatrice maximale de la microcirculation dermique. Par contre, la réactivité à réchauffement local à des températures moindres ne semble pas être affectée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Giardia duodenalis (syn. lamblia; syn. intestinalis) susceptibility testing is not routinely performed because the classical culture methods are very time-consuming and laborious. We developed a novel flow cytometry (FC) assay to evaluate the susceptibility of G. duodenalis trophozoites to metronidazole (MTZ). Different concentrations of MTZ were added to cultures of trophozoites (10 5 /mL) and the cultures were incubated for different periods. The 50% inhibitory concentration was calculated and propidium iodide (PI) was used to quantify the number of dead cells. After treatment, PI-positive trophozoites increased with increasing drug concentration and exposure time. An excellent correlation was found between FC and the classical method. A novel, accurate and reliable method is now available to evaluate G. duodenalis viability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence cystoscopy enhances detection of early bladder cancer. Water used to inflate the bladder during the procedure rapidly contains urine, which may contain fluorochromes. This frequently degradesfluorescence images. Samples of bladder washout fluid (BWF) or urine were collected (15 subjects). We studiedtheir fluorescence properties and assessed changes induced by pH (4 to 9) and temperature (15°C to 41°C).A typical fluorescence spectrum of BWF features a main peak (excitation/emission: 320∕420 nm, FWHM =50∕100 nm) and a weaker (5% to 20% of main peak intensity), secondary peak (excitation/emission: 455∕525 nm, FWHM = 80∕50 nm). Interpatient fluctuations of fluorescence intensity are observed. Fluorescence intensity decreases when temperature increases (max 30%) or pH values vary (max 25%). Neither approach is compatible with clinical settings. Fluorescence lifetime measurements suggest that 4-pyridoxic acid/riboflavin is the most likely molecule responsible for urine's main/secondary fluorescence peak. Our measurements give an insight into the spectroscopy of the detrimental background fluorescence. This should be included in the optical design of fluorescence cystoscopes. We estimate that restricting the excitation range from 370-430 nm to 395-415 nm would reduce the BWF background by a factor 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we perform a societal and economic risk assessment for debris flows at the regional scale, for lower Valtellina, Northern Italy. We apply a simple empirical debris-flow model, FLOW-R, which couples a probabilistic flow routing algorithm with an energy line approach, providing the relative probability of transit, and the maximum kinetic energy, for each cell. By assessing a vulnerability to people and to other exposed elements (buildings, public facilities, crops, woods, communication lines), and their economic value, we calculated the expected annual losses both in terms of lives (societal risk) and goods (direct economic risk). For societal risk assessment, we distinguish for the day and night scenarios. The distribution of people at different moments of the day was considered, accounting for the occupational and recreational activities, to provide a more realistic assessment of risk. Market studies were performed in order to assess a realistic economic value to goods, structures, and lifelines. As terrain unit, a 20 m x 20 m cell was used, in accordance with data availability and the spatial resolution requested for a risk assessment at this scale. Societal risk the whole area amounts to 1.98 and 4.22 deaths/year for the day and the night scenarios, respectively, with a maximum of 0.013 deaths/year/cell. Economic risk for goods amounts to 1,760,291 ?/year, with a maximum of 13,814 ?/year/cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Next Generation Access Networks (NGAN) are the new step forward to deliver broadband services and to facilitate the integration of different technologies. It is plausible to assume that, from a technological standpoint, the Future Internet will be composed of long-range high-speed optical networks; a number of wireless networks at the edge; and, in between, several access technologies, among which, the Passive Optical Networks (xPON) are very likely to succeed, due to their simplicity, low-cost, and increased bandwidth. Among the different PON technologies, the Ethernet-PON (EPON) is the most promising alternative to satisfy operator and user needs, due to its cost, flexibility and interoperability with other technologies. One of the most interesting challenges in such technologies relates to the scheduling and allocation of resources in the upstream (shared) channel. The aim of this research project is to study and evaluate current contributions and propose new efficient solutions to address the resource allocation issues in Next Generation EPON (NG-EPON). Key issues in this context are future end-user needs, integrated quality of service (QoS) support and optimized service provisioning for real time and elastic flows. This project will unveil research opportunities, issue recommendations and propose novel mechanisms associated with the convergence within heterogeneous access networks and will thus serve as a basis for long-term research projects in this direction. The project has served as a platform for the generation of new concepts and solutions that were published in national and international conferences, scientific journals and also in book chapter. We expect some more research publications in addition to the ones mentioned to be generated in a few months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miralls deformables més i més grans, amb cada cop més actuadors estan sent utilitzats actualment en aplicacions d'òptica adaptativa. El control dels miralls amb centenars d'actuadors és un tema de gran interès, ja que les tècniques de control clàssiques basades en la seudoinversa de la matriu de control del sistema es tornen massa lentes quan es tracta de matrius de dimensions tan grans. En aquesta tesi doctoral es proposa un mètode per l'acceleració i la paral.lelitzacó dels algoritmes de control d'aquests miralls, a través de l'aplicació d'una tècnica de control basada en la reducció a zero del components més petits de la matriu de control (sparsification), seguida de l'optimització de l'ordenació dels accionadors de comandament atenent d'acord a la forma de la matriu, i finalment de la seva posterior divisió en petits blocs tridiagonals. Aquests blocs són molt més petits i més fàcils de fer servir en els càlculs, el que permet velocitats de càlcul molt superiors per l'eliminació dels components nuls en la matriu de control. A més, aquest enfocament permet la paral.lelització del càlcul, donant una com0onent de velocitat addicional al sistema. Fins i tot sense paral. lelització, s'ha obtingut un augment de gairebé un 40% de la velocitat de convergència dels miralls amb només 37 actuadors, mitjançant la tècnica proposada. Per validar això, s'ha implementat un muntatge experimental nou complet , que inclou un modulador de fase programable per a la generació de turbulència mitjançant pantalles de fase, i s'ha desenvolupat un model complert del bucle de control per investigar el rendiment de l'algorisme proposat. Els resultats, tant en la simulació com experimentalment, mostren l'equivalència total en els valors de desviació després de la compensació dels diferents tipus d'aberracions per als diferents algoritmes utilitzats, encara que el mètode proposat aquí permet una càrrega computacional molt menor. El procediment s'espera que sigui molt exitós quan s'aplica a miralls molt grans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rb-82cardiac PET has been used to non-invasively assess myocardial blood flow (MBF)and myocardial flow reserve (MFR). The impact of MBF and MFR for predictingmajor adverse cardiovascular events (MACE) has not been investigated in aprospective study, which was our aim. MATERIAL AND METHODS: In total, 280patients (65±10y, 36% women) with known or suspected CAD were prospectivelyenrolled. They all underwent both a rest and adenosine stress Rb-82 cardiacPET/CT. Dynamic acquisitions were processed with the FlowQuant 2.1.3 softwareand analyzed semi-quantitatively (SSS, SDS) and quantitatively (MBF, MFR) andreported using the 17-segment AHA model. Patients were stratified based on SDS,stress MBF and MFR and allocated into tertiles. For each group, annualizedevent rates were computed by dividing the number of annualized MACE (cardiacdeath, myocardial infarction, revascularisation or hospitalisation forcardiac-related event) by the sum of individual follow-up periods in years.Outcome were analysed for each group using Kaplan-Meier event-free survivalcurves and compared using the log-rank test. Multivariate analysis wasperformed in a stepwise fashion using Cox proportional hazards regressionmodels (p<0.05 for model inclusion). RESULTS: In a median follow-up of 256days (range 168-440d), 44 MACE were observed. Ischemia (SDS≥2) was observed in95 patients who had higher annualized MACE rate as compared to those without(55% vs. 9.8%, p<0.0001). The group with the lowest MFR tertile (MFR<1.76)had higher MACE rate than the two highest tertiles (51% vs. 9% and 14%,p<0.0001). Similarly, the group with the lowest stress MBF tertile(MBF<1.78mL/min/g) had the highest annualized MACE rate (41% vs. 26% and 6%,p=0.0002). On multivariate analysis, the addition of MFR or stress MBF to SDSsignificantly increased the global χ2 (from 56 to 60, p=0.04; and from56 to 63, p=0.01). The best prognostic power was obtained in a model combiningSDS (p<0.001) and stress MBF (p=0.01). Interestingly, the integration ofstress MBF enhanced risk stratification even in absence of ischemia.CONCLUSIONS: Quantification of MBF or MFR in Rb-82 cardiac PET/CT providesindependent and incremental prognostic information over semi-quantitativeassessment with SDS and is of value for risk stratification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A first assessment of debris flow susceptibility at a large scale was performed along the National Road N7, Argentina. Numerous catchments are prone to debris flows and likely to endanger the road-users. A 1:50,000 susceptibility map was created. The use of a DEM (grid 30 m) associated to three complementary criteria (slope, contributing area, curvature) allowed the identification of potential source areas. The debris flow spreading was estimated using a process- and GISbased model (Flow-R) based on basic probabilistic and energy calculations. The best-fit values for the coefficient of friction and the mass-to-drag ratio of the PCM model were found to be ? = 0.02 and M/D = 180 and the resulting propagation on one of the calibration site was validated using the Coulomb friction model. The results are realistic and will be useful to determine which areas need to be prioritized for detailed studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sparsely spaced highly permeable fractures of the granitic rock aquifer at Stang-er-Brune (Brittany, France) form a well-connected fracture network of high permeability but unknown geometry. Previous work based on optical and acoustic logging together with single-hole and cross-hole flowmeter data acquired in 3 neighbouring boreholes (70-100 m deep) has identified the most important permeable fractures crossing the boreholes and their hydraulic connections. To constrain possible flow paths by estimating the geometries of known and previously unknown fractures, we have acquired, processed and interpreted multifold, single- and cross-hole GPR data using 100 and 250 MHz antennas. The GPR data processing scheme consisting of timezero corrections, scaling, bandpass filtering and F-X deconvolution, eigenvector filtering, muting, pre-stack Kirchhoff depth migration and stacking was used to differentiate fluid-filled fracture reflections from source generated noise. The final stacked and pre-stack depth-migrated GPR sections provide high-resolution images of individual fractures (dipping 30-90°) in the surroundings (2-20 m for the 100 MHz antennas; 2-12 m for the 250 MHz antennas) of each borehole in a 2D plane projection that are of superior quality to those obtained from single-offset sections. Most fractures previously identified from hydraulic testing can be correlated to reflections in the single-hole data. Several previously unknown major near vertical fractures have also been identified away from the boreholes.