939 resultados para Nitrogênio não-proteico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eutrophication has been listed as one of the main problems of water pollution on a global level. In the Brazilian semi-arid areas this problem takes even greater proportions due to characteristical water scarcity of the region. It is extremely important to the predictive eutrophication models development and to the reservoirs management in the semi-arid region, studies that promotes understanding of the mechanisms responsible for the expansion and control of algae blooms, essential for improving the water quality of these environments. The present study had as its main aims, evaluate the temporal pattern of trophic state, considering the influence of nutrients (N and P) and the light availability in the water column in the development of phytoplankton biomass, and perform the mathematical modelling of changes in phosphorus and chlorophyll a concentrations in the Cruzeta man-made lake located on Seridó, a typical semi-arid region of Rio Grande do Norte. To this, a fortnightly monitoring was performed in the reservoir in 05 stations over the months of March 2007 to May 2008. Were measured the concentrations of total phosphorus, total organic nitrogen, chlorophyll a, total, fixed and volatile suspended solids, as well as the measure of transparency (Secchi) and the profiles of photosynthetic active radiation (PAR), temperature, pH, dissolved oxygen and electrical conductivity in the water column. Measurements of vertical profiles have shown some periods of chemical and thermal stratification, especially in the rainy season, due to increased water column depth, however, the reservoir can be classified as warm polimitic. During the study period the reservoir was characterized as eutrophic considering the concentrations of phosphorus and most of the time as mesotrophic, based on the concentrations of chlorophyll a, according to the Thornton & Rast (1993) classification. The N:P relations suggest N limitation, conversely, significant linear relationship between the algae biomass and nutrients (N and P) were not observed in our study. However, a relevant event was the negative and significant correlation presented by Kt and chlorophyll a (r ² = 0.83) at the end of the drought of 2007 and the rainy season of 2008, and the algal biomass collapse observed at the end of the drought season (Dec/07). The equation used to simulate the change in the total phosphorus was not satisfactory, being necessary inclusion of parameters able to increase the power of the model prediction. The chlorophyll a simulation presented a good adjustment trend, however there is a need to check the calibrated model parameters and subsequent equation validation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates a new treatment system of wastewater by anaerobic and aerobic biological filters for nitrogen modification. The main objective of this study was evaluate, on a pilot scale, quantitatively and qualitatively the bacterian nitrifying community in a experimental sewage treatment system made by aerobics biological filters in series, in search of figure out the dynamic of nitrogen modification process. It was collected and laboratorial analysed microbiologically, regarding NMP of Nitrosomonas e Nitrobacter, and physical-chemically considering nitrogen sequence. We conclude that: the association in aerobic biological filters under nutrition controlled conditions and oxygen level allows the appearance of bacterian community responsible for the nitrogen modification; the method used, despite its limitations, provided the selection of autotrophic nitrifying microorganisms, allowing the identification of Nitrosomonas and Nitrobacter; the flow direction tested in the experimental unit did not affect the nitrifying bacterial community, certainly because they were kept drowned and did not occur flow speed that could breake the formed biomass; the nitrification process happened in aerated biological filters in all phases of the research, comproved by microbiological tests; in the third phase of the research the increase of the oxygen rate was significant for the nitrificant bacterian community in the aerate biological filters, allowing its growth, occurring relation between the efficiency of nitrification system and the quantity of organisms responsible for this process; the conduit used in aerated biological filters showed satisfactory performance support material to the nitrifying bacteria development

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the influence of the molar ratio, the phosphorus initial concentration, the mixture gradient, mixing time, pH and the secondary nucleation on struvite s crystallization in synthetic water in batch reactors. The study was divided into two stages. The first investigated struvite s crystallization at different Mg:N:P molar ratios and at different initial concentrations of magnesium, nitrogen and phosphorus. It was also evaluated the importance of secondary nucleation on the struvite s crystallization. In the second, five parameters were tested to evaluate their influence on the struvite s crystallization, which were: Mg:N:P molar ratio, initial concentration of phosphate, mixing time, mixture gradient and pH. The best conditions for struvite s crystallization were: Mg:N:P = 1,3:1:1 molar ratio; mixture gradient = 60 rpm, pH = 10.0, mixing time = 5 minutes and high initial concentrations of the constituent ions of struvite. Furthermore, the use of struvite crystals as seed influenced positively on the struvite s crystallization

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The struvite precipitation in wastewater treatments plants offer advantages to obtaining a economically viable product, containing phosphorus, nitrogen and magnesium, in a bioavailable conditions to plants. The precipitation process requires ideal conditions, but all of these aspects are difficult to obtain and may result in resistance to collect crystals during the sedimentation process. Therefore, instead find the best conditions for precipitation, we propose the dissolved air flotation as another method to retrieve the crystals. The application of dissolved air flotation method to promote separation of struvite crystals from sewage supernatant, was evaluated in a precipitation-flotation reactor (flotatest) and were compared with the precipitation-sedimentation assays (jar test). Finally, were observed that the dissolved air flotation process was as feasible as sedimentation to promote struvite crystals separation, and the pH are the most influencer factor for an efficient separation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sludge generated in stabilization ponds can be designed for various purposes, among them we mention agricultural use, recovery of degraded areas and civil construction. The choice of these alternatives should be made based on qualitative and quantitative characteristics of the sludge. In this context, this study characterized the digested sludge from an anaerobic lagoon in Cidade do Natal/RN, which deals exclusively with residues of depleted septic tanks and pits. The sludge showed levels of macro and micronutrients that confirm its potential for agriculture, with 139.49 g.kg -1 organic matter, 15.40 g.kg-1 nitrogen and metal concentrations below those required by Resolution No. 375/06 of CONAMA, besides the absence of fecal coliform and less than 0.15 viable helminthes eggs/g, on average. The particle size distribution showed that most of the particles have a diameter similar to the sand, allowing the replacement of this input, for example. Analysis of the leachate and of the sludge solubilized classified as non-inert and non-hazardous according to NBR 10.004/04. The volume produced in three years of operation by the pond was 1903.50m³, equivalent to approximately 400 kg of dry sludge. Overall, the concentrations of the parameters were similar to literature, although none of them addresses sludge anaerobic pond treating sewer from septic tanks and pits.The sludgepresents technical feasibility to various types of use, however the cost of dewatering and especially with transport can derail it. It needs to be made a more thorough study of the costs to prove its economic viability

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The phytoplankton growth is dependent of several abiotic (nutrients, temperature) and biotic (predation by zooplankton) variables. In this work, a mathematical model was developed in Stella software to understand the planktonic dynamics of Extremoz Lagoon (RN) and to simulate scenarios of different environmental conditions. Data were collected monthly at two points of the lagoon. The state variables are phytoplankton and zooplankton and forcing variables are nitrogen, phosphorus and temperature. The results show that: a) the model are well coupled, especially when some constants assume different values; b) simulated nutrient concentrations reduction decreases phytoplankton biomass, but the increase of nutrients does not stimulate the growth; c) changes in the temperature does not change the phytoplankton biomass; d) changes in zooplankton biomass affect directly and reduces the phytoplankton, indicating a topdown control mechanism; e) changes in the nutrient concentration modified the biomass of zooplankton suggesting a rapid flow of energy between nutrients, phytoplankton and zooplankton and a ecosystem likely arranged in an inverted pyramid (higher concentration of zooplankton than phytoplankton)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A região semiárida sofre escassez hídrica. A fim de regularizar a disponibilidade hídrica nos períodos de estiagem, são construídas barragens. No entanto, a qualidade da água armazenada tem sofrido os efeitos do descarte irregular de resíduos no meio ambiente e das atividades antrópicas exercidas nas bacias hidrográficas. A degradação hídrica pode ser constatada a partir do monitoramento dos parâmetros de qualidade da água. Estes dados podem ser analisados através de métodos estatísticos tais como a Análise de Componentes Principais e a análise de agrupamento, que seleciona indivíduos com características semelhantes. O objetivo deste trabalho é realizar oagrupamento dos reservatórios do Rio Grande do Norte, com base nos parâmetros de qualidade da água, para a identificação de grupos homogêneos de reservatórios em termos de fontes de poluição. Serão objeto desse estudo as bacias Piranhas-Açu, Apodi-Mossoró, Trairí, Potengi e Ceará-Mirim. Os parâmetros mercúrio, chumbo, cromo, fósforo total, nitrogênio total e zinco contribuíram para a formação da primeira componente principal, que pode indicar poluição por metais pesados; sólidos totais, DBO, OD e cobre, para a segunda componente, que pode ser indicativo de poluição por matéria orgânica e atividades antrópicas; e clorofila a , cádmio e níquel, para a terceira componente, que pode indicar eutrofização e poluição por metais pesados. De posse das componentes principais se procedeu o agrupamento dos reservatórios, formando-se quatro grupos distintos. Os grupos 1 e 2 são constituídos por reservatórios da Bacia Piranhas-Açu, que apresentou maiores valores de metais pesados. O grupo 3, constituído por reservatórios das bacias Ceará-Mirim, Potengi e Trairí, apresentou maiores valores de DBO e sólidostotais e o grupo 4 é formado por reservatórios da Bacia Apodi-Mossoró. Nas Bacias do Trarí e Piranhas-Açu deve ser coibido o lançamento desordenado de efluentes e fontes de poluição difusas, e implantado um sistema de coleta de esgoto para minimizar a poluição por matéria orgânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)